QuickSpecs. HP 480/277 Volt Solutions. Overview

Similar documents
QuickSpecs. HP Basic Power Distribution Units. Overview

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

Battery Pack Options - Choose up to two Battery Packs per UPS (must be the same)

QuickSpecs. HP Parallel 3 Phase Uninterruptible Power Systems Overview

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

1-Phase Intelligent ATS

HP Server Mount Kit AB292A for 19 in. 2-Post Rack Installation Instructions Manufacturing Part Number: AB April 2004

PowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

5067 Mini BDFB / BDCBB

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts V2. Overview. HP Managed and Unmanaged V2 Notebook Charging Carts

HP Modular Cooling System 200/100 Options Installation Guide

596 Rectifier Retrofit

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

CONSOLE MANAGEMENT CONTROLLER

ABB Services for Low Voltage equipment Your choice, your future

ABB life cycle services Uninterruptible power supplies

1 AMP CURRENT SOURCE

P90L-ISO6MB & ISO10MB

UL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected

E-Series and EF-Series Systems

Rack Mount Power Supplies

Power Distribution Units AP9560 & AP9561

Power and Cooling. Chassis Power System

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

How much oil are electric vehicles displacing?

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

Uninterruptible Power Systems

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

CCTV Rack Mount Power Supplies

Users Guide for Ac-sync

Back-UPS CS Back-UPS CS 350

Power Distribution Units

HP Adjustable Depth Fixed Rail Kit Installation

ClimateCab Cabinets and Accessories

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

Smart Sensor Technology in Condition Monitoring Low Voltage Motors

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

VERTIV XTE 401 SERIES. Ordering Guide

EZ SDI TM Booster Pump Assembly

3 Uninterruptible Power Systems

Electrical Installation

INTELEPOWER CX COMMUNICATIONS SYSTEMS

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

APPLICATION GUIDE. ACH580 Managing total cost of ownership of HVAC systems

ADI-125/750 ADI-125/1500 ADI-125/2500

Basic Charging Carts. Product Data Sheet VLC30SK-HD-HASP VLC36SK-HD-HASP. Overview. Features

Lighting Control Unit Installation Instructions

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Charging with AC (wall) Charger

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

POWER DISTRIBUTION UNITS (PDUs)

- 4 amp. - 4 amp. - Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected

ABB Drive Services Your choice, your future

TB-690 Conveyor/Stacker

Coleman Air ITS-240 Inverter Transfer Switch

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

36-Device ipad, Chromebook, Tablet, and Laptop Cart Steel Top, Fixed Shelves, and Hinged Doors

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

MAY 2018 Improving CAPEX and OPEX of PV power plants with high power string inverters Gianluca Pieralli (Regional Sales Manager Lat Am) / Gianluca

PDI PowerWave 2 Bus System

Features and Benefits

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

DC to AC Power Inverters

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

User Manual. Solar Charge Controller 3KW

DC to AC Power Inverters

Coleman Air ITS-240 Inverter Transfer Switch

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Date: Technical Overview of Power Requirements for Hot Runner Control Systems

CYCLONE PocketMax PP-1000 Compact Battery Pack for Portable Flashes. User Manual

SKF fan upgrade services. One source for a full range of solutions, from unique bearing systems to circulating oil lubrication systems

Liebert GXT4. Intelligent, Reliable UPS Protection 5kVA - 10kVA

OCTA FLUORESCENT 7 SOCKET FIXTURE

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Liebert. PSI & PSI-XR 750VA - 3kVA & 1kVA-3kVA High Performance Power Protection for Servers and Networking Equipment

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC

PowerValue 11/31 T kva

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Electrification Products United Kingdom. Buildings & Infrastructure Enhanced energy efficiency & performance

Electric Vehicle Charging Solutions

650mA Phase Dimmable LED Driver

EVlink. Empowering sustainable drivers around the world. Electric Vehicle Charging Stations. Make the most of your energy SM

PH21/27 POWERHOUSE Dual Generator Parallel Kit Operating Instructions

This technical bulletin applies to Spectralink 8020 and 8030 handsets and OEM derivatives. Battery Pack Technical Specifications

User Manual Breeze Revision 01.2 September 2018 Tempest Lighting, Inc.

Transcription:

Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute electricity through their facility. One such strategy in North America is to minimize the inefficient and costly transformers used to convert the high 480 volt AC power coming into the building to the lower 200-240 volt power needed for IT equipment. By bringing 480 volt power directly to the rack all transformers can be eliminated, improving efficiency by several percent. This can save hundreds of thousands of dollars in the construction or expansion of data centers while continuing to save even more in monthly operational costs. The problem is that neither today's IT equipment nor power distribution was designed to use the single phase 277 volts produced by 480 volt 3 phase distribution. The new HP 480/277 volt solutions provide the critical infrastructure at the rack to do just that. 480/277 Volt PDUs 1. Mounting buttons 3. Circuit breakers 2. LS-26 outlet receptacles 4. Inlet cord DA - 14575 North America Version 1 April 2, 2013 Page 1

Overview 800VA - 277V Input / 230V Output NA Rack Mount Transformer 1. LS-25 inlet connection 3. Input circuit breaker 2. Ground bonding screw 4. IEC320-C13 outlets 1200W Common Slot 277VA Power Supply 1. Power supply fan 2. LS-25 power connector DA - 14575 North America Version 1 April 2, 2013 Page 2

Models 480/277 Volt Basic Power Distribution Units HP Rack Mount Transformer HP Common Slot Power Supply HP 13.2kVA 480 Volt Three Phase 15 Outlet NA Basic Power Distribution HP 19.9kVA 480 Volt Three Phase 30 Outlet NA Basic Power Distribution HP 800VA - 277V Input / 230V Output NA Rack Mount Transformer HP 1200W Common Slot 277VAC Hot Plug Power Supply NOTE: www.hp.com/go/proliant/powersupply H3X07A H3X08A H3X09A 717359-B21 DA - 14575 North America Version 1 April 2, 2013 Page 3

Standard Features Key Features 13.2kVA and 19.9kVA PDU models 15 Outlet half height and 30 outlet full height models Industry standard button and keyhole mounting is compatible with HP Intelligent Series Racks and many third party racks. New LS-26 outlet receptacles specifically for 277 volt applications Outlets face the rear of the rack for easy access and improved maintenance zone clearance Waterproof IEC309 pin and sleeve input for safety 2U Rack mount transformer LS-25 inlet connection for use with HP 480/277 Volt PDUs Converts 277 volt to 230 volt for non- 277 volt compatible equipment in the same rack 800VA / 720W output is great for top of rack switches 2 transformers can be mounted back to back to save U space in the rack Uses 4 standard C13 outlets 277V Common Slot Power Supply Common Slot design for compatibility 1200W hot pluggable power supply 94% efficient Easy Installation and compatibility Standard button and keyhole mounting provides simple drop in installation in HP Intelligent Series Rack and many third party racks. Warranty Upgrade Options HP Basic PDUs are backed by a limited 3-year warranty. HP Basic PDUs automatically assume the Care Pack coverage level of any covered ProLiant server in the same rack. DA - 14575 North America Version 1 April 2, 2013 Page 4

Service and Support Service and Support HP Technology Services HP Technology Services offers you consultants and support experts to solve your most complex infrastructure problems. We help keep your business running, boost availability and avoid downtime. Protect your business beyond warranty with HP Care Pack Services When you buy HP Options, it's also a good time to think about what level of service you may need. HP Care Pack services provide total care and support expertise with committed response choices designed to meet your IT and business need. Recommended HP Care Pack Services for optimal satisfaction with your HP product Recommended Services 3-Year HP 24x7 4 hour Response, Hardware Support Onsite Service Provides you with rapid remote support and if required an HP authorized representative who will arrive on site any time and day of the year to begin hardware maintenance service within 4 hours of the service request being logged. http://h20195.www2.hp.com/v2/getpdf.aspx/5982-6547eee HP ProLiant Server Hardware Installation Provides for the basic hardware installation of HP branded servers, storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner http://h20195.www2.hp.com/v2/getpdf.aspx/5981-9356en Related HP Care Pack Services to enhance your HP product experience Related Services 3-Year HP 6 hour Hardware Support Onsite Call-to-Repair Service Provides an IT manager with a team of support specialists who will quickly begin troubleshooting the system to help return the hardware to operating condition within 6 hours of the initial service request to the HP Global Solution Center http://h20195.www2.hp.com/v2/getpdf.aspx/5982-6547en HP Proactive Select Service Provides a flexible way to purchase HP best-in-class consultancy and technical services. You can buy Proactive Select Service Credits when you purchase your hardware and then use the credits over the next 12 months. http://h20195.www2.hp.com/v2/getpdf.aspx/4aa2-3842enn Insight Remote Support Delivers secure remote monitoring and support for HP servers and storage, 24x7 at no additional cost. Available as part of HP Warranty, Care Pack and Service Contract offers. Parts and materials HP will provide HP-supported replacement parts and materials necessary to maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements. Supplies and consumable parts will not be provided as part of this service; standard warranty terms and conditions apply. Parts and components that have exceeded their maximum supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating manual or the technical product data sheet will not be provided, repaired or replaced as part of this service. DA - 14575 North America Version 1 April 2, 2013 Page 5

Service and Support Coverage For ProLiant servers and storage systems, this service covers HP-branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as external monitors up to 22" and tower UPS products; these items will be covered at the same service level and for the same coverage period as the server unless the maximum supported lifetime and/or the maximum usage limitation has been exceeded. Coverage of the UPS battery is not included; standard warranty terms and conditions apply. The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced by HP due to malfunction. It does not apply to any exchange of Disk or SSD/Flash Drives that have not failed. SSD/Flash Drives that are specified by HP as consumable parts and/or that have exceeded maximum supported lifetime and/or the maximum usage limit as set forth in the manufacturer's operating manual or the technical data sheet are not eligible for the defective media retention service feature option. For more information To learn more on services for HP ESSN Options, please contact your HP sales representative or HP Authorized Channel Partner. Or visit: http://www.hp.com/services/proliant or www.hp.com/services/bladesystem DA - 14575 North America Version 1 April 2, 2013 Page 6

Related Options 277 Volt jumper cords HP LS-26 to LS-25 277 Volt 15Amp AC 0.76m Jumper Cord TK801A HP LS-26 to LS-25 277 Volt 15Amp AC 1.37M Jumper Cord TK802A NOTE: 277 volt jumper cords can be used to connect the HP 800VA - 277V Input / 230V Output NA Rack Mount Transformer to HP 4800/277 Volt Basic PDUs. DA - 14575 North America Version 1 April 2, 2013 Page 7

Model Matrix 480/277 Volt Basic PDUs 13.2kVA 480/277V PDU 19.9kVA 480/277V PDU Part Number H3X07A H3X08A Input Voltage 480 volt, 30 amp, 3 phase, 5 wire (WYE) Input Connection 96 inches (243.8 cm) with attached IEC 530P7 96 inches (243.8 cm) with attached IEC 530P7 Facility power connection IEC 309 480 volt, 30 amp, 3 phase, 5 wire (IEC 530C7) IEC 309 480 volt, 30 amp, 3 phase, 5 wire (IEC 530C7) Output Receptacles 15 x Rong Feng 203-P-HP (LS-26) 15 x Rong Feng 203-P-HP (LS-26) Current (max) 27.72 amps across all three phases 41.57 amps across all three phases Frequency (Hertz) 50-60Hz 50-60Hz Load Capacity (VA) 13301 (@480V) 19952 (@480V) Output Circuit Breakers 3 X 20A 6 X 20A 277 Volt Rack Mount Transformer 800VA 277V / 230V Rack Mount Transformer Part Number H3X09A Input Voltage 277 volt line -neutral Input Connection Rong Feng 203-HP (LS-25) Facility power connection 230 volt single phase Output Receptacles 4 x IEC309-C13 Current (max) 800VA Frequency (Hertz) 720 watts Load Capacity (VA) 60Hz Output Circuit Breakers 1 X 4A 277 Volt Common Slot Power Supply 1200W Common Slot 277VAC Hot Plug Power Supply Part Number 703247-101 Input Voltage 200-277 volt line to neutral Frequency (Hertz) 50-60hz Input Connection Rong Feng 203-HP (LS-25) Output Wattage (max) 1200 watts Efficiency 94% at 50% load Power Factor.999 NOTE: For more information on all HP Common Slot power supplies got to www.hp.com/go/proliant/powersupply NOTE: Please refer to the Power Cord Matrix for more information on power cords/cable part numbers, input/output descriptions: http://www.hp.com/go/powercordmatrix. Disclaimer: HP makes no recommendations regarding power connector manufactures. The model numbers listed in the above tables are strictly for the purpose of providing examples. Please consult a licensed professional to determine the best connector or receptacle for your specific needs. DA - 14575 North America Version 1 April 2, 2013 Page 8

Technical Specifications 480/277 Volt Basic PDUs Operating Temperature 50 to 122 F (10 to 50 C) Operating Relative Humidity (%) 10% to 90% Operating Elevation 0 to 10,000 ft (0 to 3048 m) Storage Temperature -4 to 140 F (-20 to 60 C) Storage Relative Humidity (%) 5% to 95% Storage Elevation 0 to 30,000 ft (0 to 9144 m) Input Plug Length 96 inches (243.8 cm) Conformance Standards UL, CUL Mechanical Dimensions (WxHxD), 15 outlet model 1.98 x 32.4 x 3.15 in ( 5.03 x 82.3 x 8 cm) Unit Weight, 15 outlet model 20 lb (9.07 kg) Mechanical Dimensions (WxHxD), 30 outlet model 1.98 x 62.9 x 3.15 in ( 5.03 x 159.7 x 8 cm) Unit Weight, 30 outlet model 40 lb (18.14kg) 277 Volt Rack Mount Transformer Operating Temperature 32 to 131 F (0 to 55 C) Input connection Rong Feng 203-HP (LS-25) Conformance Standards UL, CUL Mechanical Dimensions (WxHx1D), 30 outlet model 17.3x 3.2 x 14.36 in ( 439.5 x 81.28 x 364.8cm) Unit Weight, 30 outlet model 66lb (27.22kg) Environment-friendly Products and Approach End-of-life Management and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. DA - 14575 North America Version 1 April 2, 2013 Page 9

Technical Specifications DA - 14575 North America Version 1 April 2, 2013 Page 10