Water Level Meter + Temperature

Similar documents
ETL Water Level Meter

(450 m-925 m) ET/MDPE Tape Water Level Meter (with optional electric rewind)

Geotech Interface Meter

Product Recovery Canister

SDS Specific. Pump. Installation and Operation Manual. Depth Sampler. Rev. 06/04/12 Part #

Geotech Filter Holders

Geotech VFD for Redi-Flo2

Product Recovery Canister

Geotech Hand Pump. Installation Guide. Rev. 2 6/18/02 Part #

Geopump Peristaltic Pump

Geotech Hand Pump. Installation and Operation Manual. Rev 1/25/2017 Part #

Geopump Peristaltic Pump Installation and Operation Manual

Geotech Geopump Peristaltic Pump

Geopump Peristaltic Pump Installation and Operation Manual

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

362 Clamp Meter. Users Manual

SLA Battery Capacity Analyzer

OPERATING INSTRUCTIONS

i3000s/i2000 Flex AC Current Probe

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

CONTACT WATERRA. WS-2 REELCASE WATER LEVEL TAPE

Users Manual. Phase Rotation Indicator

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Go to to register your product and find more information.

Product Manual. Table of Contents. Innoquest Item # Safety Information Introduction Meter Diagram Features.

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

Model 1693, 1694 Switching DC Power Supply

LED-6200T 144 LED VARIABLE COLOR ON-CAMERA LIGHT USER MANUAL

92831 TEL: (714) FAX:

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Instruction Manual Part No

Defender 3000 Series Base Instruction Manual

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

Model 1672, 1673 Triple Output Power Supply

PLS SLD. Laser Detector PACIFIC LASER SYSTEMS. For use with your PLS pulsed laser alignment tool. The Professional Standard

i400s Calibration Information Introduction

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

OWNER S MANUAL PRODUCT CODE: BOD1907

TECHNICAL MANUAL. FOR BLAST 2 (Bright Light Aiming System Tactical 2) For Rifles and Pistols Equipped with MIL-SPEC-1913 and Picatinny Rails

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

1000FLT. Users Manual. Fluorescent Light Tester

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Megohmmeter Test Probe

362 Clamp Meter. Users Manual

Model 1900, 1901, 1902 Switching DC Power Supply

SeekTech Inductive Clamp

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables


IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Cable Length Meter INSTRUCTION MANUAL

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

Where to Find Us. Pressure Washer. Model Number Revision Serial Number. Date Purchased

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

This manual covers the following model:

233 True-rms Remote Display Digital Multimeter Safety Information

60 Watt Industrial LED Low Bay Light

2-DOOR LAUNDRY CABINET KIT

Air-Operated Waste Oil Drainer

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Instruction Manual IVT-10 / IVT-20 Voltage Tester

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Infrared Thermocouple Probe

Model P772 Conductivity Meter. User Manual

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Spotlight 1,000,000 Power Series Cordless Rechargeable

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

CONGRATULATIONS. on your purchase of a Viridian Grip Laser, the most advanced sighting device available.

1 AMP CURRENT SOURCE

USER S GUIDE HIGH INTENSITY ULTRASONIC PROCESSOR

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Thermocouple Thermometer Models

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

KMP Insulation-Continuity Tester. Users Manual

2-in-1 Air Operated Waste Oil Drainer

FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Transcription:

Water Level Meter + Temperature Installation and Operation Manual Rev 05/23/2017 Part # 12050744

Table of Contents SECTION 1: SYSTEM DESCRIPTION... 3 SECTION 2: SYSTEM INSTALLATION... 6 SECTION 3: SYSTEM OPERATION... 7 SECTION 4: SYSTEM MAINTENANCE... 8 SECTION 5: SYSTEM TROUBLESHOOTING... 9 SECTION 6: SYSTEM SPECIFICATIONS... 10 SECTION 7: SYSTEM SCHEMATIC... 12 SECTION 8: REPLACEMENT PARTS LIST... 13 EC DECLARATION OF CONFORMITY... 15 THE WARRANTY... 17 1

DOCUMENTATION CONVENTIONS This uses the following conventions to present information: WARNING An exclamation point icon indicates a WARNING of a situation or condition that could lead to personal injury or death. You should not proceed until you read and thoroughly understand the WARNING message. CAUTION A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equipment malfunction or damage. You should not proceed until you read and thoroughly understand the CAUTION message. A note icon indicates NOTE information. Notes provide additional or supplementary information about an activity or concept. NOTE Notice for consumers in Europe: This symbol indicates that this product is to be collected separately. The following applies only to users in European countries: This product is designated for separate collection at an appropriate collection point. Do not dispose of as household waste. For more information, contact the seller or the local authorities in charge of waste management. 2

Section 1: System Description Function and Theory The Geotech ETL Water Level Meter +Temperature (ETL WLM+T) is a portable instrument used to accurately measure water levels and temperature in monitoring wells and bore holes. The sensor consists of a stainless steel and PTFE probe attached to a reel-mounted, PVDF-coated engineer s tape. The engineer's tape comes in standard or metric graduations, and is accurate to 1/100th of a foot, or 1 millimeter. The sensor relies on fluid conductivity to determine the presence of water. An audible signal and visible blue LED activate when the probe contacts water, and there is a mute button to silent the signal while probing for temperature. The reel features adjustable conductivity sensitivity to prevent false triggering. The ETL WLM+T is intended for use as a depth to water measuring device and temperature sampling. Using the ETL WLM+T for any other purpose may compromise safety of the operator and/or void manufacturer s warranty. To avoid damage to tape and strain relief, do not over tighten reel with probe in storage position. System Components Figure 1-1: ETL WLM + T Front View 3

Figure 1-2: ETL WLM + T Side View Figure 1-3: ETL WLM + T User Interface 4

Figure 1-4: ETL WLM + T Probe 5

Section 2: System Installation Place the reel next to the well casing and carefully lower the probe into the well using the tape leader guard to prevent damage to the tape. Do not use the tape leader guard in wells larger than 4 (10cm), as it may fall down the well. The optional tape weight helps sink probe into a deep or crooked well. An optional Tape Guide, to prevent the edge of the well casing from damaging the tape, is also available from Geotech. Figure 2-1 is an example of the two parts. Figure 2-1: Tape Guide (optional), Tape Weight (optional), Tape Leader Guard Optional Tape Weight Installation Attach tape weight to tape near probe end being lowered into well. 1) Loosen the screws using and Allen wrench. 2) Slide the weight onto the tape (Figure 2-2). 3) Tighten the screws (Figure 2-3). Figure 2-2: Fitting (Optional) Tape Weight Figure 2-3: Tightening (Optional) Tape Weight 6

Section 3: System Operation Turn ON the ETL WLM+T with the ON/SENSITIVITY knob. If the buzzer makes a loud double-signal and the LCD turns ON, the battery is adequate for normal operation. Lower the probe down the well to the water surface. The blue light and buzzer will activate when it make contact with the conductive fluid. With the probe still in contact with the water, adjust the ON/SENSITIVITY knob clockwise until the light and buzzer barely activate. In this setting, the probe will detect the water level and avoid false triggering. Water level and temperature measurements can now be taken from the top of the casing or any reference point. There is a Mute button on the control faceplate that silences the signal while probing for temperature. The blue LED will stay illuminated while the probe is in water. The ETL WLM+T should be stored with the ON/SENSITIVITY switch in the OFF position. To turn the unit off, rotate the switch fully counter-clockwise until the switch clicks. If the ETL WLM+T is not used and is stored for longer than three (3) months, remove the battery to prevent battery leakage, which can cause internal damage. To avoid damage to the tape and strain relief, do not over tighten the reel with the probe in storage position. This unit is not rated for use with hydrocarbons or flammable liquids. If measuring depth to fluid of wells containing hydrocarbons, use Geotech s line of interface probe products. 7

Section 4: System Maintenance Battery Replacement Replace the battery when the audible and visible signals become weak or the unit does not operate. 1. Gently remove the battery tray. 2. Remove the old battery and replace it with a new one. Be aware of the polarity (+, -) of the battery when placing the new battery in the tray. Use a 9V alkaline battery only. Cleaning The ETL WLM+T can be cleaned with mild detergents such as trisodium phosphate (TSP). If other detergents are used, take care to select detergents that are compatible with PTFE, PVDF, and stainless steel. The reel should not be submerged in any liquid, but may be cleaned with a damp cloth. Cleaning the Conductivity/Temperature Contact The conductivity contact of the probe should be periodically cleaned with a nonabrasive cleaner such as isopropyl alcohol, xylene, methanol, or phosphate free type cleaner. To clean the conductivity contact, place a small amount of the cleaner on a cotton swab; rub the conductivity contact to remove all foreign matter. Repeat this process until all foreign matter has been removed. 8

Section 5: System Troubleshooting Problem: No signal (audible or visible) when unit is turned on. Solutions: The battery is discharged. Check or change battery (Section 4: System Maintenance). The circuit is malfunctioning. Contact Geotech Service. Problem: No indication of water. Solutions: The conductive contact is dirty. Clean the contact (Section 4: System Maintenance). There is an open connection in the tape. Replace tape and/or probe. The circuit is malfunctioning. Contact Geotech Service. Problem: The signal (audible or visible) is intermittent. Solutions: There is an open connection in the tape. Replace tape and/or probe. There is a loose connection in the circuit or the probe. Repair the connection. Problem: The signal (audible or visible) is continuous when not in water. Solutions: The conductive contact is dirty (causing bridging). Clean the contact (Section 4: System Maintenance). There is a short in the tape and/or probe. Replace tape and/or probe. The circuit is malfunctioning. Contact Geotech Service. For technical assistance, call Geotech Environmental Equipment at 1-303-320-4764 or 1-800-833-7958 9

Section 6: System Specifications 5/8 Probe Material: Stainless steel, PTFE, Viton Weight: 4.7 oz (133 g) Diameter: Length: 0.625 (1.59 cm) 6.125 (19.7 cm) Minimum Conductivity Threshold (detects water at): 10µS Operating temperature range: Temperature accuracy: Max immersion temperature: 32 158 F (0 70 C) +/- 1 F (0.5 C) 302 F (150 C) Tape Material: Accuracy: PVDF coated steel tape w/ stainless steel conductors 100th of a foot/100 (3 mm/30.5 meters) Per Federal Specification: GGG-T-106E Reel/Frame (100 500 frame) Material: Steel & aluminum Size: 15 H x 11.5 W x 10.5 D (38 cm H x 29 cm W x 27 cm D) (750 1000 frame) Material: Steel & aluminum Size: 15 H x 11.5 W x 14.5 D (38 cm H x 29 cm W x 37 cm D) Reel + Tape Length: Weight: 100 (30m) 14 lbs. (6.4 kg) 200 (60m) 16 lbs (7.3 kg) 300 (100m) 18 lbs. (18.2 kg) 500 (150m) 20 lbs. (9.1 kg) 750 (225m) 24 lbs. (10.9 kg) 1000 (300m) 28 lbs. (12.7 kg) 10

Unit Battery: Max power: Max sound pressure output: 9 volt, Alkaline < 1 Watt 75 db @ 30 cm Insulation rating: Insulation rating is considered double as there are no hazardous voltages or power circuits to pose a threat to the operator. Battery life: Output tone: Operating temperature range: Storage temperature range: Response time: Operating environment: Continuously detecting: 6 hours On but not detecting: >1 year 5 khz 32 158 F (0 70 C) -40 158 F (-40 70 C) <10 milliseconds Rated for outdoor use. Humidity: 0-100% Elevation: Tape Weight (Optional) -328 13,124 (-100 4000 meters) 1 (2.54cm) OD, 4 (10.16cm) Long, 12.74oz (361g) 11

Section 7: System Schematic Figure 7-1: ETL Water Level Meter + Temperature (front view) Figure 7-2: ETL Water Level Meter + Temperature (side view) 12

Section 8: Replacement Parts List Parts List on next page 13

Item # Parts Description Part # 1 ASSY,REEL,300-500FT,GEOWLM 52050021 ASSY,REEL,750-1000FT,GEOWLM 52050043 2 PROBE HOLDER, 5/8", ETL 52050220 3 REPAIR,TAPE,WLM+T,100',PVDF TAPE 52050286 REPAIR,TAPE,WLM+T,200',PVDF TAPE 52050287 REPAIR,TAPE,WLM+T,300',PVDF TAPE 52050288 REPAIR,TAPE,WLM+T,500',PVDF TAPE 52050289 REPAIR,TAPE,WLM+T,750',PVDF TAPE 52050290 REPAIR,TAPE,WLM+T,1000',PVDF TAPE 52050291 REPAIR,TAPE,WLM+T,30M,PVDF TAPE 52050292 REPAIR,TAPE,WLM+T,60M,PVDF TAPE 52050293 REPAIR,TAPE,WLM+T,100M,PVDF TAPE 52050294 REPAIR,TAPE,WLM+T,150M,PVDF TAPE 52050295 REPAIR,TAPE,WLM+T,225M,PVDF TAPE 52050296 REPAIR,TAPE,WLM+T,300M,PVDF TAPE 52050297 4 ASSY,CONTROL,GEOWLM+T 52050299 5 ASSY,PROBE,GEOWLM+T 52050298 6 BRAKE,CAM LEVER DRAG,ETL 11400070 7 HANDLE,MANUAL CRANK,W/HDWR 12050624 8 O-RING, VITON,.480 x.039, BROWN 17500202 9 WASHER, WAVE 12050255 10 KNOB, INDICATING, 1/4, RND 12050090 Not shown: GUARD,LEADER,PROPAMIDE,NATURAL 12050060 GUIDE,TAPE,PVC 22050601 ASSY,WEIGHT,TAPE,SS,1"X4.1",0.75LBS (360 GRAMS) 52050277 BAG, WLM/IP, 500-1000 12050113 BUZZER,3-24VDC,PIEZO 12050118 MANUAL, INSTRUCTION, GEOWLM+T 12050744 14

EC Declaration of Conformity Manufacturer: Geotech Environmental Equipment, Inc. 2650 E 40th Avenue Denver, CO 80205 Declares that the following products, Product Name: Model(s): Water Level Meter + Temperature, manual rewind only ETL Water Level Meter + Temperature, all tape lengths Year of manufacture: 2017 Conform to the principle safety objectives of 2006/95/EC Low Voltage Directive by application of the following standards: EN 61010-1: 2010 EN 809-1 + A1:2010 Year of affixation of the CE Marking: 2017 Conform to the protection requirements of 2004/108/EC Electromagnetic Compatibility (EMC) by application of the following standards: EN 61000-6-1: 2007 EN 61000-6-3: 2012 EN 61326-1: 2013 EMC conformity established 5/24/2017 Production control follows the ISO 9001:2008 regulations and includes required safety routine tests. This declaration issued under the sole responsibility of Geotech Environmental Equipment, Inc. Joe Leonard Product Development Serial number 5/24/2017 15

DOCUMENT REVISIONS EDCF# DESCRIPTION REV/DATE Project # 1470 Release, SB 5/15/2017 16

The Warranty For a period of one (1) year from date of first sale, product is warranted to be free from defects in materials and workmanship. Geotech agrees to repair or replace, at Geotech s option, the portion proving defective, or at our option to refund the purchase price thereof. Geotech will have no warranty obligation if the product is subjected to abnormal operating conditions, accident, abuse, misuse, unauthorized modification, alteration, repair, or replacement of wear parts. User assumes all other risk, if any, including the risk of injury, loss, or damage, direct or consequential, arising out of the use, misuse, or inability to use this product. User agrees to use, maintain and install product in accordance with recommendations and instructions. User is responsible for transportation charges connected to the repair or replacement of product under this warranty. Equipment Return Policy A Return Material Authorization number (RMA #) is required prior to return of any equipment to our facilities, please call our 800 number for appropriate location. An RMA # will be issued upon receipt of your request to return equipment, which should include reasons for the return. Your return shipment to us must have this RMA # clearly marked on the outside of the package. Proof of date of purchase is required for processing of all warranty requests. This policy applies to both equipment sales and repair orders. FOR A RETURN MATERIAL AUTHORIZATION, PLEASE CALL OUR SERVICE DEPARTMENT AT 1-800-833-7958. Model Number: Serial Number: Date of Purchase: Equipment Decontamination Prior to return, all equipment must be thoroughly cleaned and decontaminated. Please make note on RMA form, the use of equipment, contaminants equipment was exposed to, and decontamination solutions/methods used. Geotech reserves the right to refuse any equipment not properly decontaminated. Geotech may also choose to decontaminate the equipment for a fee, which will be applied to the repair order invoice. 17

Geotech Environmental Equipment, Inc 2650 East 40th Avenue Denver, Colorado 80205 (303) 320-4764 (800) 833-7958 FAX (303) 322-7242 email: sales@geotechenv.com website: www.geotechenv.com