Problem Statement. Focal Point: Potential for multiple fatalities/injuries, loss of station

Similar documents
Problem Statement. Unique Timing After oversized truck passed through outer lane of Interstate 5.

Problem Statement. After losing hydraulic systems when engine #1 detached during takeoff.

Problem Statement. Focal Point: 36 Fatalities, dozens of injuries, loss of Hindenburg airship

Root Cause Analysis Report

Environmental Health and Safety Office

Emergency Services Guidance for Competition Electric Vehicles

Golf Cart Safety Procedures

Discover the power of seven! 5. Enjoy 24/7 U.S.-based customer service. 6. Use at 11,000+ Exxon- or Mobil-branded stations

MOUNT KIT. Ford Super Duty F-250/350/450/550. Installation Instructions CAUTION. Read this document before installing the snowplow.

MOUNT KIT. Polaris Ranger Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Powered Industrial Trucks

50 Gordon Drive, Rockland, Maine sherplows.com MOUNT KIT. Installation Instructions CAUTION

RUTGERS UNIVERSITY POWERED INDUSTRIAL TRUCK PROGRAM

50 Gordon Drive, Rockland, Maine sherplows.com MOUNT KIT. Ford Super Duty F-250/350/450/550. Installation Instructions CAUTION

MOTOR VEHICLE ORIENTED BUSINESSES.

MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

ASSEMBLY 39TH SESSION

Golf cart safety. Don t Let A Golf Cart Accident ruin Your Game! Clip Art Courtesy of:

MOUNT KIT PERSONAL PLOW. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

MOUNT KIT. John Deere HPX Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

DynoTune Wideband Gauge

This defines the lower and upper threshold if applicable to incorporate cases in the database

EPS Fleet Safety Manual

MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

INSTALLATION GUIDE FUELTEC- FUEL POLISHING SYSTEM

MODEL 1324ST ST HYDRAULIC TRENCHER OPERATOR S MANUAL

MODEL 912RM/912HM HYDRAULIC TRENCHER OPERATOR S MANUAL

IMPORTANT INFORMATION

ETHANOL 1100 FIREPLACE OWNER S MANUAL

75918 Heavy Duty 3-Point Mount

Intended Users This document is intended for Gasboy-certified Authorized Service Contractors (ASCs) and Customer Specified Contractors (CSCs).

DynoTune Wideband Gauge

Western Products, PO Box , Milwaukee, WI MOUNT KIT. Dodge 4500/ Sterling Bullet 45/

Sector 213 Newsletter

Western Products, PO Box , Milwaukee, WI MOUNT KIT. Installation Instructions CAUTION

MOUNT KIT. Arctic Cat 700 HDX Exmark 500S, 700S Toro 500 EFI, 700 EFI Installation Instructions CAUTION

ONLY TRAINED AND AUTHORIZED EMPLOYEES TRAINING CAN BE GOOD FOR UP TO 3 YEARS BUT THE TRAINER WILL DETERMINE THE DURATION BASED ON SKILL EVALUATION

TESTER ISOLATION MODULE LIGHT SYSTEM. Operating Instructions. CAUTION Read this document before testing any snowplows.

Model: HT9605H HT0165B. Hurricane Plus OPERATION SERVICE PARTS CARE. Revised 9/04

IMAGINE IOT PROTOTYPE CHALLENGE IMPROVING WASTE DISPOSAL

Inspecting Airport Fueling Systems

Safer and Easier with Conductive Piping. Making Fuel Flow Safely.

UNDERCARRIAGE KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Summary of Hanover College Vehicle and Parking Regulations

Discussing the Ratepayer Benefits of EVs On the Electrical Grid

Mount Kit. Chevy/GMC 1500HD/2500/3500 4X Chevy/GMC Suburban 2500 Yukon XL Installation Instructions CAUTION

MOUNT KIT. Kubota RTV 900, 1140 Kubota RTV X-Series. Installation Instructions CAUTION. Read this document before installing the snowplow.

MOUNT KIT. Ford Bronco, F-150 4X Ford F-250/350/Super Duty Installation Instructions CAUTION

LABORATORY SAFETY SERIES: Electrical Safety

50 Gordon Drive, Rockland, Maine MOUNT KIT

Safe Driving Standards & Procedures

1533 TRUCK MOUNT. Installation Instructions for Personal Plow. Chevrolet Trailblazer GMC Envoy

50 Gordon Drive, Rockland, Maine sherplows.com MOUNT KIT

VIRGINIA RAILWAY EXPRESS MANASSAS PARK STATION PARKING EXPANSION. Site Evaluation & Recommendation. October 18, 2016

Systems Repair Worksheet Chapter 6 Pages Working Safely in the Shop 52 Points. Be Certain to Read the Summary

MOUNT KIT PERSONAL PLOW

Vista Municipal Code

OWNER S / OPERATOR S MANUAL

Paid Parking at Park & Ride Lots: Framing the Issues. Capital Programs Committee May 2014

Module 4: Fire Fighting Foam Principles and Biodiesel Fuel

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

MOUNT KIT PERSONAL PLOW

Visitors Health, Safety Security & Environmental Guide

MOUNT KIT. Polaris General 1000 Polaris RZR 900, Installation Instructions CAUTION. Read this document before installing the snowplow.

Summary of Hanover College Vehicle and Parking Regulations

MOUNT KIT PERSONAL PLOW. GM K1500 Silv/Sierra. Installation Instructions CAUTION. Read this document before installing the snowplow.

MOUNT KIT. Dodge 4500/ Sterling Bullet 45/ Installation Instructions CAUTION

MOUNT KIT. Kawasaki Mule Installation Instructions CAUTION. Read this document before installing the snowplow.

Parking Rules and Regulations

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures IVN Authority: Effective Date: Page 1 of WETHERINGTON/HODGE 4/01/02 5

WHAT YOU DON T KNOW COULD BURN YOU! How To Avoid The Unknown Dangers Of Handling Fuel In Your Shop

USC Upstate Policy For The Safe Operation of Golf Carts, Accessibility Carts, Low Speed and Utility Vehicles on Campus

Blizzard, PO Box , Milwaukee, WI B Undercarriage Kit. John Deere Gator XUV/HPX

33220 MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

City of Grand Island

Frequently Asked Questions Rideshare Program

MOUNT KIT PERSONAL PLOW. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

MOUNT KIT GM K2500 w/8600 GVW GM K GM K2500 Suburban w/8600 GVW

B32207 UNDERCARRIAGE KIT. Parts List and Installation Instructions CAUTION. Read this document before installing the snowplow.

On-Demand Mobile Fueling

FAQs for the Draeger Interlock 7000

MOUNT KIT PERSONAL PLOW

Replacing the Carburetor

MOUNT KIT. GM K1500 Silv/Sierra. Installation Instructions CAUTION. Read this document before installing the snowplow.

50 Gordon Drive, Rockland, Maine sherplows.com MOUNT KIT. Dodge 4500/ Sterling Bullet 45/

MOUNT KIT PERSONAL PLOW

Insta-Act Hydraulic Unit Installation Instructions

Propane torch. Model Assembly And Operation Instructions

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

50 Gordon Drive, Rockland, Maine MOUNT KIT. Jeep Wrangler Installation Instructions

GEN 5.0 Generator Service Manual

Name Date. True-False. Multiple Choice

IMPORTANT INFORMATION

MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

2.1 Faculty: Employees of the University defined by PS 10.A Staff: benefits-eligible employees of the University, excluding Faculty.

Western Products, PO Box , Milwaukee, WI MOUNT KIT

DISCUSSION For the purpose of this General Order, the following definitions shall apply:

MOUNT KIT. Dodge Ram 2500/ Installation Instructions CAUTION. Read this document before installing the snowplow.

"ELECTRICAL SAFETY IN THE LABORATORY"

Transcription:

ear Miss - Risk of Explosion Problem Statement Report umber Sologic Video Example 3 RCA Owner Brian Hughes Report Date 12/10/2015 RCA Facilitator Brian Hughes Focal Point: Potential for multiple fatalities/injuries, loss of station When Start Date: 12/10/2015 End Date: 12/10/2015 Start ime: 7:15 AM Unique iming Where Site Location Actual Impact End ime: 7:15 AM While gas station store area was under construction. 76 Station - E 124th Street, Kirkland WA USA Within 10 feet of gas pump, outside the front door of the store Safety one $0.00 Frequency Frequency ote Potential Impact Unknown Actual Impact otal: $0.00 Safety Potential multiple fatalities and injuries $0.00 Safety Potential fire and explosion $0.00 Environmental Potential for large release of fuel $500,000.00 Revenue Potential loss of all revenue from the site for months $500,000.00 Cost Potential loss of facility $1,000,000.00 Reputation (External) Potential community impact $0.00 Potential Impact otal: $2,000,000.00 Created with Causelink Page 1 of 5

ear Miss - Risk of Explosion Cause and Effect Summary Report Summaries On 10-December, 2015 at 7:15AM a high-risk event occurred involving a person smoking near an operational gas pump. o actual adverse impact was experienced as a result of this event. A customer at a gas station observed a construction worker smoking a cigarette within 5 feet of the pump. he convenience store building was in the process of being remodeled at the time. A group of 3 workers was working on the project. he project area had been fenced in with temporary chain link fencing. he workers were inside the temporary fence. he fenced area included the fueling bays directly adjacent to the store. However, three other fueling bays remained open to self-service customers. he high-risk was determined based on the potential for gasoline vapors to ignite while people were in close proximity. Potential ignition sources include the burning cigarette as well as the means of lighting the cigarette (match or lighter). Potential fuel sources include flammable vapors released during the fueling process or vapors from a potential gasoline spill. At the time of the event, three workers were present along with three customers. Other customers were coming and going at the time. he station is near a major thoroughfare with pedestrians periodically walking by. It is unknown why the worker was smoking near the fueling area. It is possible there was no designated smoking area. It is also possible that the worker simply chose to smoke away from the designated smoking area. -- ED OF SUMMARY -- Created with Causelink Page 2 of 5

ear Miss - Risk of Explosion SO-0001 Solution Close the pumps during construction ote Gas pumps remained open during construction his would be expensive in the form of lost revenue, but also best at reducing risk of fire and explosion for any reason. Compare to the cost of an actual fire/explosion. Criteria ot Checked Due Status Validated erm short Cost $180,000.00 SO-0002 Solution Close the inside bank of pumps during construction. ote Gas pumps remained open during construction his would be a less extreme version of above. wo pumps would remain open, but the safety buffer between the construction and the pumps would be larger. Cory Boisoneau; Criteria ot Checked Due 1/18/2016 Status Approved erm Cost $60,000.00 SO-0003 Solution Set up designated smoking area ote o designated smoking area? Make sure it's well away from the construction site and the fuel pumps behind the store. here is an outdoor area in the southwest corner of the lot. Include a pop-up tent, table, and chairs. Also include a fire extinguisher. Criteria ot Checked erm short Cost $250.00 SO-0004 Solution Don't allow smoking on the site. ote Worker chose to smoke outside of designated smoking area? he problem with this is it will be difficult to enforce 100% of the time. Criteria ot Checked erm SO-0005 Solution Discipline the worker Created with Causelink Page 3 of 5 Cost

ote Worker chose to smoke outside of designated smoking area? his would only be appropriate if he was violating an in-place policy and if he was a multiple offender. Criteria ot Checked erm SO-0006 Solution Add smoking to all safety meetings. When is it appropriate, where should smoking take place, etc. ote Cost Worker chose to smoke outside of designated smoking area? his should happen at all worksites. Criteria ot Checked erm Cost Created with Causelink Page 4 of 5

ear Miss - Risk of Explosion Facillitator Brian Hughes brian.hughes@sologic.com Participants Jon Boisoneau jon.boisoneau@sologic.com eam Owner Brian Hughes brian.hughes@sologic.com Chris Eckert chris.eckert@sologic.com Created with Causelink Page 5 of 5

Gas pumps remained open during construction Wanted to keep making money while the store was shut down ED Desired State O2: Outside environment ED Close the pumps during construction Criteria Status Validated his would be expensive in the form of lost revenue, but also best at reducing risk of fire and explosion for any reason. Compare to the cost of an actual fire/explosion. Fuel vapors from filling process at pump? Close the inside bank of pumps during construction. Criteria Status Approved his would be a less extreme version of above. wo pumps would remain open, but the safety buffer between the construction and the pumps would be larger. Potential for multiple fatalities/injuries, loss of station Potential Fire and Explosion - Gas Station Fuel: Gasoline vapors Potential ignition sources OR AD OR Fuel vapors from spilled fuel? People need fuel ED? Potential ignition Worker smoking within 5 source: Cigarette feet of fuel pump a Connects o: Potential ignition source: Lighter/match a Worker smoking within 5 feet of fuel pump OR Desired State Store area under construction Smoking habit by at least one worker o designated smoking area? Set up designated smoking area Make sure it's well away from the construction site and the fuel pumps behind the store. here is an outdoor area in the southwest corner of the lot. Include a pop-up tent, table, and chairs. Also include a fire extinguisher. ED ED Desired State? Workers ED Worker chose to smoke outside of designated smoking area?? People are in proximity 24 hours/day Customers ED Don't allow smoking on the site. he problem with this is it will be difficult to enforce 100% of the time. Discipline the worker his would only be appropriate if he was violating an in-place policy and if he was a multiple offender. Passers-by ED Add smoking to all safety meetings. When is it appropriate, where should smoking take place, etc. his should happen at all worksites.