General section System Manual Part 1

Similar documents
Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

Analog input module. Brief description. Page 1/8. Data Sheet

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

J TS 7090 Thyristor power switch

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000

Pressure transmitter JUMO dtrans p02

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

SINAMICS GM150 IGCT version

Technical Documentation

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Electronic Circuit Breaker ESS20-0..

INTECH Micro 2300-RTD6

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Operation Instructions

1.1 Caution Statements

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Electronic Ballast EVG 2000-T

INSTALLATION INSTRUCTIONS

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Panel-mounting Thermostats EM Series. B Operating Instructions 11.06/

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Foreword

Fuse state indicator MEg72. User manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

LED Driver Linear / area fixed output

Welcome to the ABB Industrial Drives, ACS800 planning the installation training module. If you need help navigating this module, click the Help

Local Control Network - building controls in perfection

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Issue 2.0 December EPAS Midi User Manual EPAS35

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

SPEEDRIVE INSTRUCTIONS MANUAL

Switching DC Power Supply

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Pulsar EXtreme CLA 1500C

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Appendix: Safety and application notes for 19

EPAS Desktop Pro Software User Manual

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

DATA SHEET Genset Control Unit, GCU 100

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

Electronic Circuit Breaker ESS20

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

MIC4 IGNITION CONTROLLER

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

MGL Avionics EFIS G2 and iefis

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

User Manual Solar Charge Controller 3KW

Appendix: Safety and application notes for... 15

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

INDUSTRIAL POWER SUPPLIES SFL-SERIES

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

JUMO ecotrans Lf 01/02

Operating Instructions (Translation)

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

TECHNICAL DATA SHEET KVA UPS Systemss

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

MCD 200 Series Soft Starters

LR9 F OVERLOAD RELAYS

EDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

USERS MANUAL MCD REMOTE OPERATOR

SCXI Power Supply/Float Charger Installation Guide

Technical data sheets

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

The Battery is a client module in the Cabinet Control. It is a backup/ups module which

Transcription:

General section 70.4000 System Manual Part 1

Contents 1 Introduction 3 1.1 Foreword... 3 1.2 List of items supplied... 4 1.3 Accessories... 5 1.4 Typographical conventions... 6 2 The JUMO mtron automation system 9 2.1 JUMO mtron modules... 9 2.2 Project design software JUMO mtron-itool... 11 3 Mounting in position 13 3.1 Location and climatic conditions... 13 3.2 Dimensions... 13 3.3 Mounting the module on the rail... 15 3.4 Removing the module... 15 3.5 Fitting the operating unit in position... 16 3.6 Removing the operating unit... 17 4 Electrical connection 19 4.1 Installation notes... 20 4.2 Network connection... 22 4.3 LON termination resistance... 24 4.4 Suitable cable... 25 5 Module replacement 27 5.1 Plug & Play... 27 5.1.1 Operating unit... 27 5.1.2 Other modules... 30 6 Appendix 33 6.1 Technical Data... 33 6.2 Training facilities / seminars... 34 7 Index 35 3.00/System Manual JUMO mtron Part 1

Contents Part 1 3.00/System Manual JUMO mtron

1 Introduction 1.1 Foreword B H Trademarks The System Manual is addressed to the OEM (original equipment manufacturer) and to the user with appropriate technical know-how. It describes the specification of the JUMO mtron automation system with its modules and provides all the information required for system design and start-up. This part 1 of the System Manual summarises the information which applies to all the modules. This is supplemented by descriptions on the individual modules in other system manuals. Part 2 of the System Manual Project Design Software JUMO mtron-itool describes the project design in the mtron automation system. Keep this System Manual in a place which is accessible to all users. If any difficulties should arise during start-up you are asked not to carry out any manipulations which are not permitted. This could endanger your rights under the warranty. Please contact the nearest office or the main factory. LON and Neuron are registered trademarks of the Echelon Corporation. Microsoft and Windows are registered trademarks of the Microsoft Corporation. Please assist us to improve this System Manual where necessary. Your suggestions will be most welcome. Phone Germany (06 61) 60 03-7 27 abroad (int.+ 49) 661 60 03-0 Fax Germany (06 61) 60 03-5 08 abroad (int.+49) 661 60 03-500 3.00/System Manual JUMO mtron 1 3

1 Introduction 1.2 List of items supplied Check each shipment for completeness and damage. If anything is missing or damaged please contact the nearest JUMO office or the main factory. Module JUMO mtronitool Contents of the CD-ROM The equipment supplied consists of: - the module(s) - Installation Instructions - connector blocks with screw terminals and - mounting elements. The installation instructions are addressed to the personnel responsible for installation and electrical connection. It describes the module with its indications and controls, provides assistance in cabling, and contains the electrical connection diagram. The JUMO mtron-itool project design software consists of: - CD-ROM - System Manual JUMO mtron. The project design software JUMO mtron-itool and the installation program are stored on a CD-ROM. It is installed on a PC from the CD-ROM by means of the installation program. A set of diskettes of the project design software JUMO mtron-itool can be copied by means of the installation program. With the diskettes the project design software can also be installed on a PC without CD-ROM. 1 4 3.00/System Manual JUMO mtron

1 Introduction 1.3 Accessories PC interface A PC interface can be supplied for setting the module parameters. The cable, 2 m long, with TTL/RS232C converter links the module to a PC. Sales No. 70/00301315 JUMOmTRONiTOOL Using the JUMO mtron-itool project design software, JUMO mtron automation systems can be designed graphically on the PC. The program in its menu structure follows the arrangement of MDI programs under Windows. This means that several projects can be opened simultaneously, each of which is shown in its own project window. The user is able to link modules together via the network so that data can be interchanged. The settings of application-specific parameters is also possible. 3.00/System Manual JUMO mtron 1 5

1 Introduction 1.4 Typographical conventions Warnings V A E The signs for Danger and Warning are used in this Manual under the following conditions: Danger This symbol is used when there may be danger to personnel if the instruction is disregarded or not followed accurately. Warning This symbol is used when there may be damage to equipment or data if the instruction is disregarded or not followed accurately. Warning This symbol is used where special care is required when handling electrostatically sensitive components. Notes H v Note This symbol is used when your special attention is drawn to a remark. Reference This symbol refers to addtional information in other handbooks or sections. abc 1 Footnote Footnotes are notes which refer to certain points in the text. Footnotes consist of 2 parts: Markings in the text and the footnote text. The markings in the text are arranged as continuous raised numbers. The footnote text (in smaller typeface) is placed at the bottom of the page and starts with a number and a full stop. h Action This symbol indicates that an action is being described. The individual steps are indicated by this symbol, e.g.: h switch off the supply h pull connectors off the module 1 6 3.00/System Manual JUMO mtron

1 Introduction Scaling start [ScalStart] Representation on the operating unit The parameter texts are shown in abbreviated form on the operating unit. The abbreviations are given in square brackets. Presentation P o E Keys Keys are shown as boxes. Both symbols and text are possible. Where a key has multiple functions, the text shown is the one corresponding to the actual function discussed. P + r Key combinations Depiction of keys together with a plus sign means that the keys must be pressed simultaneously. Scaling start Screen texts Where this System Manual refers to concepts of the JUMO mtron-itool project design software these are shown in italics, if that is helpful (e. g. block structures). Edit instrument data... Menu items Where this System Manual refers to menu items of the JUMO mtron-itool project design software they are shown in italics. Menu name, menu item and submenu item are each separated by the symbol. 3.00/System Manual JUMO mtron 1 7

1 Introduction 1 8 3.00/System Manual JUMO mtron

2.1 JUMO mtron modules 2 The JUMO mtron automation system The JUMO mtron automation system consists of autonomous modules which have defined functions assigned to them. The module housing, size 91 x 85.5 x 73.5mm (W x H x D) is made from plastics and mounted on a standard rail. Connection to sensors and actors are made through plug connectors with screw terminals. Each unit incorporates a network connection for communication and for data exchange between the units. Numerous process and status signals can be exchanged with other units via the network. A screened twisted pair is used as transmission line. There is a setup interface for parameter setting and configuration of the units. Controller module Apart from logic inputs there are two analogue inputs for standard signals, Pt100 and thermocouples. The outputs consist of two logic outputs and one analogue output. Using the function blocks ramp, maths, controller and limit comperator it is possible to build up complex control structures. Two controller parameter sets are stored for four definable setpoints. A fully developed auto-tuning function automatically adapts the controller to the characteristics of the process. Relay module This module provides the functions limit comparator, pulse duration modulation and pulse frequency modulation through logic outputs. Switch-on and switch-off delays can be defined on the limit comparator. Integral drivers can be used for operating motorised actuators. 3.00/System Manual JUMO mtron 1 9

2 The JUMO mtron automation system Analogue input module The module has four analogue signal inputs which can be configured for all the usual sensor signals. Linearisation of the signals through a customized table is also available. The four signal inputs are arranged in two groups, with isolation between the groups. The module incorporates a maths function and a comparator through which linkages between the signals can be generated. The results are output to the network. Analogue output module The analogue output module has two isolated analogue outputs. The output signals correspond to the values at the network inputs, converted according to the set parameters (current 0 20 ma or 4 20 ma, voltage 0 10V or 2 10V). Using a logic input a process status can be captured and processed in subsequent modules. Communication module Logics module Operating unit The communcation module can be linked to a PC through an RS232C interface. Networking with other automation units is possible in the version with RS485/422 interface using the MODbus protocol. External alarm messages can be handled using a logic input. Logic network inputs for alarm processing are also available. Together with a modem the module provides a connection to the JUMO mtron modules via the public telephone system and permits remote operation of the installation. An internal 512kbyte store is available for storing process signals. The logics module has eight logic inputs and six logic outputs. With this module the user is able to define his own arithmetic and/or logic functionalities which can be used as required within the overall system. The input is made using the Structured Text user programming language. Logic, arithmetic, bit sequence, comparative, selection and instruction operations are available. A library contains function blocks for e.g. timing elements, counters, edge recognition, bistable functions and many more. The operating unit is mounted into the cabinet door and permits optimal and orderly insight into the process states and the system parameters of the JUMO mtron automation system. Using six keys the parameters of the JUMO mtron modules can be set via the network under menu guidance. In addition, user-defined process windows and alarm messages can be shown on the 2 x 20 place display. 1 10 3.00/System Manual JUMO mtron

2 The JUMO mtron automation system 2.2 Project design software JUMO mtron-itool JUMO mtron-itool is the design, start-up and installation tool for LON networks which are realised with the modules of M. K. JUCHHEIM GmbH & Co. A module library containing the individual modules as graphic objects can be called up at any time during project design. The modules required for the project are taken from the library using Drag & Drop and can be placed freely on the working area. Any names can be assigned to the modules to provide a direct relationship with the real installation. The object carries a module-dependent pictogram for quick visual recognition. Using JUMO mtron-itool the user is able to link modules of the JUMO mtron automation system, to set application-specific parameters with the aid of the embedded setup program, and to load the completed project in the JUMO mtron automation system. When the project design has been completed and the project is operating, values of network variables can be indicated online. This provides a direct check on the design of the real installation. v System Manual Part 2 Project Design Software JUMO mtron-itool 3.00/System Manual JUMO mtron 1 11

2 The JUMO mtron automation system 1 12 3.00/System Manual JUMO mtron

3 Mounting in position 3.1 Location and climatic conditions Modules Operating unit The modules are designed for mounting in cabinets on standard rails 35mm x 7.5mm to EN 50 022. Protection is IP20 to EN 60 529. The operating unit is suitable for fitting into control panels. Protection is IP65 on the front and IP20 at the back (EN 60 529). The ambient temperature at the location can be between 0 and 50 C at a relative humidity not exceeding 80% (EN 61 010) without condensation. v Section 6.1: Technical Data 3.2 Dimensions Modules 3.00/System Manual JUMO mtron 1 13

3 Mounting in position Operating unit 1 14 3.00/System Manual JUMO mtron

3 Mounting in position 3.3 Mounting the module on the rail h Hook the module on the rail from above h Swing it down until the housing clicks home 3.4 Removing the module V Switch off the power supply! h Pull off the screw terminal blocks I und II (1) h Insert a screwdriver into the release clip on the underside of the module and lever it upwards (2). The housing can be swung out forward (3). 3.00/System Manual JUMO mtron 1 15

3 Mounting in position 3.5 Fitting the operating unit in position h Insert the operating unit into the panel cut-out from the front (1) h Insert the mounting brackets into the recesses at the sides (2) h Tighten up the mounting brackets evenly against the back of the panel (3) 1 16 3.00/System Manual JUMO mtron

3 Mounting in position 3.6 Removing the operating unit V Switch off the power supply! h Pull off the setup plug (1) h Pull off the screw terminal blocks (2) h Release the mounting brackets using a screwdriver (3) and take them out of the recesses at the sides (4) h Pull the operating unit forward out of the panel (5) 3.00/System Manual JUMO mtron 1 17

3 Mounting in position 1 18 3.00/System Manual JUMO mtron

4 Electrical connection Connections The following connections are available: Module Operating unit Plug connector I with screw terminals Plug connector I with screw terminals Plug connector II with screw terminals V The electrical connection must only be made by a properly qualified electrician! Label The label is affixed to the housing and contains all the information on the condition as supplied. A The voltage of the supply must agree with the voltage stated on the label. 3.00/System Manual JUMO mtron 1 19

4 Electrical connection 4.1 Installation notes The choice of cable, the installation and the electrical connection of the module must conform to the requirements or the appropriate local regulations. Work on the modules must only be carried out to the extent described and, like the electrical connection, only be carried out by properly qualified personnel. If contact with live parts is possible when working on the module it has to be isolated on both poles from the supply. The external fuse of the supply should not be rated above 10 A (slow). The load circuit should be fused for the maximum relay current in order to prevent welding of the output relay contacts in case of an external short-circuit. Electromagnetic compatibility conforms to the standards and regulations listed under Technical Data. v Section 6.1 Technical Data The module is not suitable for installation in hazardous areas. Run input, output and supply lines separately and not parallel to each other. Sensor and interface lines should be arranged as twisted and screened cables. Do not run them close to current-carrying components or cables. On temperature probes earth the screen at one end at the module on terminal TE; on the LON interface at both ends (at each module). If the installation does not have a technical earth, connect the TE terminal on the module to the potential earth (PE) terminal. Do not loop earth lines, i.e. do not run them from one terminal to another, but run them singly e.g. to earth terminals on the rail (short leads!). Apart from faulty installation, there is a possibility of interference or damage to controlled processes due to incorrect settings on the module (setpoint, data of parameter and configuration levels). Safety devices independent of the module, such as overpressure valves or temperature limiters/monitors, should always be provided and should be capable of adjustment only by specialist personnel. Please refer to the appropriate safety regulations in this connection. 1 20 3.00/System Manual JUMO mtron

4 Electrical connection The signal inputs of the module must not exceed a maximum potential of 30 V AC or 50 V DC against TE. Setup interface and inputs are not isolated. Inputs carrying potentials should be potential-free before setup, using an earthed PC before setup, or the setup should be performed using a nonearthed PC or laptop. Plug connectors with screw terminals should only be unplugged when the circuits are de-energised. 3.00/System Manual JUMO mtron 1 21

4 Electrical connection 4.2 Network connection LON The JUMO mtron automation system is based on the fieldbus concept called LON (Local Operating Network). Each of the autonomous units of the JUMO mtron automation system incorporates a Neuron chip. The heart of each Neuron chip is formed by three integrated processors (CPUs) which have defined tasks assigned to them. LON technology provides all seven layers of the OSI layer model on the Neuron chip. This concept ensures with three processors a clear division of communication and application tasks. The JUMO mtron automation system employs as transmission line a screened twisted pair. Wiring layouts include line, ring, star or mixed structures (free topology). Line structure The physical ends are provided at both ends with a termination resistance of 100Ω which is activated by a switch on the module. v Section 4.3 LON termination resistance Ring structure With this wiring layout, the network remains functional even after a break. The termination resistance of any module in the ring has to be set to 50Ω. v Section 4.3 LON termination resistance 1 22 3.00/System Manual JUMO mtron

4 Electrical connection Star structure The termination resistances of any module in the star has to be set to 50Ω. v Section 4.3 LON termination resistance Mixed structure The termination resistances of any module has to be set to 50Ω. v Section 4.3 LON termination resistance 3.00/System Manual JUMO mtron 1 23

4 Electrical connection 4.3 LON termination resistance Modules Operating unit The switches for the termination resistance of the LON network are located on the module front, underneath the setup interface. h Using a screwdriver (width 3 mm max.), move both switches to the required position. Switches down: termination resistance active (1) Switches up: termination resistance inactive (2) The switches for the termination resistance of the LON network are located on the underside of the operating unit, left of the plug-in screw terminals. 1 24 3.00/System Manual JUMO mtron

4 Electrical connection 4.4 Suitable cable LON interface Screening A screened twisted pair is used as connecting cable as shown in the illustration. The screen should be protected against static charges by a resistor. Cable types Supplier Cross-section maximum cable length Line 1,4 mm 2 (AWG 16) 0,34mm 2 (AWG 22) Ring/Star/Mixed 1,3 mm 2 (AWG 16) 0,34mm 2 (AWG 22) 2700m 1400m 500m 400m Hersteller Typ Fa.Bekon, 14947 Felgentreu Bekonflex - Li 2 YCY Other connections Conventional stranded copper cable of 1.5 mm 2 cross-section is suitable for the connection of transducers, supply and logic inputs to screw terminals. 3.00/System Manual JUMO mtron 1 25

4 Electrical connection 1 26 3.00/System Manual JUMO mtron

5 Module replacement 5.1 Plug & Play The Plug & Play function provides simple and reliable operation of the LON network in case individual modules should fail, need servicing, or have to be repaired. This function ensures the proper functioning of the module after replacement, without requiring the JUMO mtron-itool project design software. H Creation and modification of an mtron network (addition or removal of modules) does, however, involve the use of the JUMO mtron-itool project design software. Each modules carries a memory card which contains the configuration data. When a module is replaced, this card only has to be fitted into the new module, which will then operate with the original configuration data. A If the memory card is not replaced, then the module parameters have to be reset via the JUMO mtron-itool. 5.1.1 Operating unit Dismantling the module E Avoid electrostatic charge when replacing the memory card. It is advisable to change the card on a workbench which is suitable for carrying out work on semiconductors (earthed worktop, antistatic shoes, etc.). h Disconnect the module from the supply by pulling off the connectors h Remove 4 crosspoint screws (1) and 1 nut (2) at the positions marked h Pull off the aluminimum housing 3.00/System Manual JUMO mtron 1 27

5 Module replacement h Push apart the guides on the sides (3) (card is held by the lugs) h Pull out card and fold it down (4) 1 28 3.00/System Manual JUMO mtron

5 Module replacement Changing the memory card h Pull out old card from the socket (5) and insert it in the same place in the new operating unit. A Only modules of the same type may be replaced (e. g. operating unit for operating unit). If the memory card is inserted into a module with another function, then the network will not recognize the operating unit. Furthermore, the data on the memory card will be deleted. Assembling the module h Assemble the operating unit in reverse order h Refit the connectors H If the memory card is not replaced, then the module parameters have to be reset through JUMO mtron- itool. 3.00/System Manual JUMO mtron 1 29

5 Module replacement 5.1.2 Other modules Dismantling the module E Avoid electrostatic charge when changing the memory card. h Disconnect the module from the supply by pulling off the connectors h Using a suitable tool, release the baseplate at the positions marked (1). 1 30 3.00/System Manual JUMO mtron

5 Module replacement h Pull out baseplate (1). Remove card downwards from housing (2). Replacing the memory card h Pull out old card from the socket (3) and insert in the same position in new module A Only modules of the same type may be replaced (e. g. controller module for controller module). If the memory card is inserted into a module with another function, then the network will not recognize the operating unit. Furthermore, the data on the memory card will be deleted. Assembling the module h Assemble the operating unit in reverse order h Refit the connectors H If the memory card is not replaced, then the module parameters have to be reset through JUMO mtron- itool. 3.00/System Manual JUMO mtron 1 31

5 Module replacement 1 32 3.00/System Manual JUMO mtron

6 Appendix 6.1 Technical Data General operating conditions Operating and ambient temperature 0 50 C (0 40 C according to EN 61 010 ) Storage temperature 40 to +70 C Relative humidity not exceeding 80 % (to EN 61 010) Pollution degree 2 (to EN 61 010) Overvoltage category 2 (to EN 61 010) Protection IP20 (to EN 60 529) Operating unit front: IP65 (to EN 60529) Mechanical stress through vibration and acceleration to EN 61 010 variable sinusoidal test: vibration frequency: 10 55 10Hz repetition rate: 1 octave per minute vibration displacement: 0.15 min. test duration: 30 minutes in each direction (x, y, z planes) EMC test to IEC 801 and NAMUR Electrostatic discharge contact discharge: 8kV, severity 4 air discharge: 15kV, severity 4 Electromagnetic field field strength: 10V/m, severity 3 Fast transient / burst on supply 4kV, severity 4 on I/O lines 2kV, severity 4 Surge symmetrical 1kV, severity 3 non-symmetrical 2kV, severity 3 Additional requirements to NAMUR recommendations Function maintained during supply interruptions up to 20msec at minimum supply voltage Inrush current limitation The peak inrush current at a 50 % width of at least 5 msec is less than 15 times the nominal peak value. EMC interference emission to postal regulation EN 55 022, Class B 3.00/System Manual JUMO mtron 1 33

6 Appendix 6.2 Training facilities / seminars Continued education has become essential in today s modern automation technology. As one of the leading manufacturers in measurement and control technology we shall in future increase our activities to pass on to customers and staff our specialised knowledge on products and general basic subject. For this purpose we have established in Fulda (Germany) a new training centre equipped with the latest technical aids. In addition to theoretical analysis it is the practical training in individual courses, with work on models and simulators, which forms an important part of the training. It is mainly in these practical sessions that the knowledge required for this work can be transmitted. A summary of the courses available can be found in our Training Calender. For each course there is a detailed description including interest groups, training targets and description of the course contents. Further information on training, the individual seminars and the application forms can be obtained from the local JUMO office or subsidiary. 1 34 3.00/System Manual JUMO mtron

7 Index A Acceleration 1-33 Accessories 1-5 Action 1-6 Additional requirements 1-33 Addresses in Germany and abroad 1-34 Analogue input module 1-10 Analogue output module 1-10 Appendix 1-33 B Bus structure 1-22 C Climatic conditions 1-13, 1-33 Communication module 1-10 Connections 1-19 Connector with screw terminals 1-19 Controller module 1-9 D Danger 1-6 Dimensions 1-13 E Electrical connection 1-19 EMC test to IEC 801 1-33 F Fitting operating unit into panel 1-13 Footnote 1-6 I Installation Instructions 1-4 Installation notes 1-20 Interface, PC 1-5 Items supplied, list of 1-4 J JUMO mtron modules 1-9 JUMO mtron-itool 1-5 3.00/System Manual JUMO mtron 1 35

7 Index K Keys 1-7 L Label 1-19 Location 1-13 Logics module 1-10 LON Local Operating Network 1-22 M Mechanical stress 1-33 Menu items 1-7 Module, mounting on rail 1-15 Module, removal 1-15 Mounting on standard rail 1-13 N Network connection 1-22 Note(s) 1-6 O Operating conditions, general 1-33 Operating unit 1-10 Operating unit, fitting in position 1-16 Operating unit, removal 1-17 P PC interface 1-5 Plug & Play function 1-27 Presentation 1-7 Project design software JUMO mtron-itool 1-11 R Reference 1-6 Relay module 1-9 Removing the module 1-15 Replacing faulty modules 1-27 S Screen texts 1-7 Seminars 1-34 Structure, mixed 1-23 1 36 3.00/System Manual JUMO mtron

7 Index Structure, ring 1-22 Structure, star 1-23 Structured text 1-10 T Termination resistance, switch for 1-24 Training facilities 1-34 Twisted pair 1-22 Typographical conventions 1-6 V Vibration 1-33 W Warning 1-6 Warnings 1-6 Warranty 1-3 Work on the modules 1-20 3.00/System Manual JUMO mtron 1 37

7 Index 1 38 3.00/System Manual JUMO mtron