In-Wall Slide-out COMPONENT ASSEMBLY MANUAL

Similar documents
SlimRack Slide-out COMPONENTS ASSEMBLY MANUAL. Rev: Page 1 SlimRack Components Assembly Manual

Standalone Smart Jack OEM INSTALL MANUAL. Rev: Page 1 Standalone Smart Jack OEM Install Manual

SCHWINTEK TV LIFT (AUSTRALIA) INSTALLATION MANUAL

F.A.S.T. Ramp Rear Door SERVICE MANUAL

Equa-Flex Tandem and Triple OEM INSTALLATION MANUAL

Lexington L-Shaped Expandable Lounge OWNER'S MANUAL

In-Wall Slide-Out (Winnebago)

Hitch Receiver OEM INSTALLATION MANUAL

Flip Automatic Jack Foot

PSX2 (Power Stabilizing System) OEM INSTALLATION MANUAL

Self-Deploying Rail Kit OEM INSTALLATION MANUAL

Ground Control 3.0 Landing Gear

Ground Control 3.0 Landing Gear OEM INSTALLATION MANUAL

Ice House Axle OEM INSTALLATION MANUAL

Patriot Jack Systems OEM INSTALLATION MANUAL

Tire Linc OEM INSTALLATION MANUAL

Ice House Axle OEM INSTALLATION MANUAL

In-Wall Slide-Out REPAIR KIT MANUAL. Rev: Page 1 In-Wall Repair Kits Manual

EuroLoft Bed Lift OWNER'S MANUAL

SlimRack Bed Lift System OEM INSTALLATION MANUAL

Ground Control 3.0 Landing Gear OWNER'S MANUAL

Road Armor Triple Axle Equalizer by Trailair

F.A.S.T. Track Flush Floor Slide-out. (Fast Assembly Self Tensioning) OWNER'S MANUAL

In-Wall Slide-Out (Winnebago Version) OWNER'S MANUAL

Easy Approach OEM INSTALLATION MANUAL (FOREST RIVER)

Solera Power Awning TROUBLESHOOTING AND SERVICE MANUAL

SlimRack Bed Lift System OWNER'S MANUAL

Patriot Jack Systems OWNER'S MANUAL

PSX2 (Power Stabilizing System) OWNER'S MANUAL

Level-Up LCD 5th Wheel TROUBLESHOOTING GUIDE

Electric Stabilizer Jack

In-Wall Slide-Out OWNER'S MANUAL. Rev: Page 1 In-Wall Slide-out Owner's Manual

Schwintek Bunk Lift INSTALLATION MANUAL. Rev: Page 1 Schwintek Bunk Lift OEM Installation Manual

X-Ramp Hydraulic Lowering System OEM INSTALLATION MANUAL

IMGL and 9510 Control Replacement Kit #214 INSTALLATION MANUAL

OEM INSTALLATION MANUAL

Sway Command Tow Control System

Trailer Axle Beam Replacement SERVICE MANUAL

Triple Play Ramp Door OEM INSTALLATION MANUAL

Ground Control TT Leveling System OWNER'S MANUAL

Kwikee IMGL Step Control Testing Procedure #82-ST0500

Coachstep OWNER'S MANUAL

Sway Command Tow Control System (For Travel Trailer) OEM INSTALL MANUAL. Rev: Page 1 Sway Command OEM Install Manual

Level-Up Motorhome Leveling

Compact Triple Electric Step OWNERS MANUAL

Above Floor Slide-out OEM INSTALLATION MANUAL

Bauer NE Lock OWNER'S MANUAL

Intelli-view Tank Monitor

Ground Control 3.0 (5th Wheel) 4 Point and 6 Point

Sway Command Tow Control System OWNER'S MANUAL

Power Tongue Jack OWNER'S MANUAL

Turning Point Pin Box. by Trailair OWNER'S MANUAL

OEM INSTALLATION MANUAL

Embedded Rack Slide-out System

Waste Master OWNER'S MANUAL. Rev: Page 1 Waste Master Owner's Manual

OEM INSTALLATION MANUAL

EuroLoft Bed Lift OWNER'S MANUAL

SLIMRACK SLIDE-OUT MOTOR AND DRIVE BLOCK REPLACEMENT

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

KWIKEE #888 ELECTRIC STEP. Owner's Manual ( )

Hydro-Sync Slide-Out System

Kwikee # Series Step OWNER'S MANUAL ( )

Kwikee Platinum Series OWNER'S MANUAL

Kwikee Revolution Step Series

Ground Control 3.0 (5th Wheel) 4 Point and 6 Point OneControl Touch Panel OWNER'S MANUAL

Level-Up (Towable) System

KWIKEE DOOR SWITCH STEP ACTIVATION INSTALLATION GUIDE ( )

Ground Control TT Leveling with LCD Touch Pad

Level-Up With OneControl Touch Panel OWNER'S MANUAL

SOLERA AWNING GAS STRUT REPLACEMENT

LCI4A3LCD Hydraulic Leveling

Hydraulic Through Frame Slide-out SERVICE MANUAL

LCI Motorized Leveling - Unidirectional (2009-Present)

Correct Track. Correct Track Installation and Owner s Manual. Installation and Owner s Manual (For Aftermarket Applications)

Ground Control and 6 Point OneControl Touch Panel

ULTRA LEVEL MOTORIZED LEVELING

Aftermarket Manual. Aftermarket Manual. Table Of Contents. Rota-Flex Pin Box

TRAILER AXLE MAINTENANCE

Electric Through Frame Slide-Out

DISC AND ELECTRIC BRAKE MAINTENANCE

Trailer Axle Hub Replacement SERVICE MANUAL

LCI Motorized Leveling ( )

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Rev: Flow Max 115V AC Fluid Pump

G C G III. OE Installation Manual

Triple Play Ramp Door OWNER'S MANUAL

LCI Level-Up Motorhome Leveling (2013-Present) OWNER'S MANUAL. Rev: Page 1 LCILevel-Up MotorhomeLeveling (2013-Present)OwnersManual

Correct Track Suspension Alignment System

Class C Hydraulic Leveling System OEM INSTALLATION MANUAL

Owner s Manual Dual Planetary Gearmotor Auto Programming Slim Rack Slide Out System

Electric Brakes OWNER'S AND SERVICE MANUAL. Electric Brake Owners and Service Manual

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

LCI4A3LCD Hydraulic Leveling (Sprinter Bolt- On Mounting Bracket) OEM INSTALLATION MANUAL

Class C Hydraulic Leveling System OEM INSTALLATION MANUAL

HYDRAULIC LANDING GEAR REPLACEMENT

Aftermarket Manual. Aftermarket Manual. Table Of Contents. Ground Control 3.0

RAMP DOOR INFINITE HINGE INSTALLATION

GENUINE PARTS INSTALLATION INSTRUCTIONS

Jeep Wrangler Heavy Duty Drag Link Installation Instructions

Assembly Instructions

Transcription:

In-Wall Slide-out COMPONENT SSEMLY MNUL

TLE OF CONTENTS System Information 2 Safety Information 2 Resources Required 2 Motor Removal 2 Timing Procedure 3 Installing Shipping ngles 4 Notes 5 System Information The Lippert Components, Inc. In-Wall Slide-out System can now be shipped disassembled at the large components level. This means that some assembly will be required prior to the installation of the In-Wall Slide-out System onto the slide-out room. The following instructions are supplied as a guide to the proper assembly of the shipped components for the best possible functioning and operation of the In-Wall Slide-out System. This manual is to be used in conjunction with the In-Wall Slide-out OEM Installation Manual. Safety Information Resources Required Moving parts can pinch, crush or cut. Keep clear and use caution during assembly. Cordless or electric drill or screw gun ppropriate drive bits Motor Removal Note: LCI recommends that the assembly be done on a clear workbench to prevent damage to the system. 1. In order to install the gear racks, the motor needs to be removed. The motor is held in place by a retention screw (Fig. 1). It is typically located on the exterior side of the column, near the motor ventilation holes (Fig. 1). Removal of the retention screw will allow the motor to easily slide out of the column. 2. Set the motor and screw aside for later re-assembly. Fig. 1 Rev: 11.28.2017 Page 2 In-Wall Slide-out Component and ssembly Manual

Timing Procedure The top and bottom gear racks on each side of the In-Wall Slide-out System are connected by a torque shaft that runs from the upper bearing block to the lower bearing block. The bearing blocks and torque shaft are mounted inside of the column. The column is fastened to the side wall opening of the unit. The timing of the system from top to bottom is considered to be adjustment free, as it is essentially locked in correct time. In the instance that the system is not timed properly, either the top or the bottom will extend farther than its opposite. The following procedure will help to set system timing. 1. Place the wider side of the H-column flat on a level surface. 2. Closest to the motor end, slide the notched side of the gear rack (Fig. 2) onto the shoe of the upper bearing block (Fig. 2) until the spur gear is engaged. 3. For the lower gear rack, slide the notched side of the gear rack (Fig. 3) onto the shoe of the lower bearing block (Fig. 3) until the spur gear is engaged. Note: The lower gear rack will have the angle shape to allow for the gear rack to be butted up to the bottom of the slide room during installation. 4. Hand turn the torque shaft (Fig. 4) until both gear racks move up and both gear racks are located at the initial stage on the spur gear. 5. pply downward pressure to one of the gear racks. This will cause both gear racks to move simultaneously on their respective spur gear. t this point, the gear racks will be synchronized. 6. Move the gear racks on the H-column to an approximate center location. Make sure the H-column is not covering any screw holes of the gear rack. 7. Re-install the motor and retention screw into the H-column. 8. Once both gear racks are engaged, use a tape measure and measure from the column to the end of each gear rack. The measurements must be the same to ensure that the slide room will be timed correctly. 9. Repeat steps 1-8 for the other In-Wall Slide-out assembly. Fig. 2 Fig. 3 Fig. 4 Rev: 11.28.2017 Page 3 In-Wall Slide-out Component and ssembly Manual

Installing Shipping ngles 1. 2. 3. On the exterior side of the H-column, place a shipping angle (Fig. 5) at both ends of the upper and lower gear racks (Fig. 5). See Fig. 5 details for orientation of the shipping angles on the gear racks. lign the pre-drilled holes in the shipping angle with the pre-drilled hole on the face of the notched end and the extruded hole on the end of the non-notched end. Secure the shipping angles to the gear racks with provided screws. Fig. 5 Exterior Rev: 11.28.2017 Page 4 In-Wall Slide-out Component and ssembly Manual

Notes Rev: 11.28.2017 Page 5 In-Wall Slide-out Component and ssembly Manual

The contents of this manual are proprietary and copyright protected by Lippert Components, Inc. ( LCI ). LCI prohibits the copying or dissemination of portions of this manual unless prior written consent from an authorized LCI representative has been provided. ny unauthorized use shall void any applicable warranty. The information contained in this manual is subject to change without notice and at the sole discretion of LCI. Revised editions are available for free download from lci1.com. Please recycle all obsolete materials. For all concerns or questions, please contact Lippert Components, Inc. Ph: (574) 537-8900 Web: lci1.com Email: customerservice@lci1.com