Similar documents
3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

Polycarbonate manholes

483 mm (19 ) Server Cabinet Unique Series. Abstract. Features. 1.5 mm strong steel sheet. Load capacity up to 1000 kg. Standard colors grey and black

Small cases... the perfect shell for valuable electronics

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs

Traffic Guidance Signs Type TGS and Retrofit-Kit

10 Enclosures. Table of Contents 10 Enclosures. 10 Enclosures... Page xx. 10 SOHO... Page xx. SOHO-Accessories... Page xx

Pixus Technologies Catalog

483 mm (19 ) Wall Mounting Cabinets IP55 (Outdoor), 600 mm width mm, 600 mm depth

GTK 80. Technical data

Product Data For FARNELL

ELECTRO HYDRAULIC THRUSTERS

Door available front and rear

Distribution Boards AT/U Series

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

483 mm (19 ) Network Cabinet Dynamic Basic Series, 600, 800 mm width - 600, 800 mm depth

KP35 series VARIABLE INNER DISTRIBUTION QUICK AND EASY TO OPEN ROBUST ALL-ROUNDER

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table

YOUR WISH IS OUR COMMAND. Junction boxes. Catalogue-Junction boxes

Application Guide EH1, EH2, EH3, EH6. PolySafe. Mersen Canada Toronto Inc.

IVS Distribution System. IVS - Table of Contents

Rondelec Armoire de trottoir

Quadro Outdoor T2 S/D

Explosion protected terminal boxes type, GHG 72.

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

ROWEKO LOAD-SECURING EQUIPMENT

Above ground hydrants Modifi cation rights reserved

Heavy-Duty Suspension System CS-2000 System 80

Dental Art presents Alchemist

Consumer units. Index. Pages. Consumer units UK500 series 1-3 Product features 1-12 Ordering information 1-18 Technical information

Light/Energy. Halogen floodlight. Fire Brigade 500 W halogen floodlight. Fire brigade 1000 W halogen floodlight. Quality since 1903

Pro-Line II Filing Frame

Installation instructions and maintenance for the Graf MINIMAX -Filter internal and external

ABS lifting station Synconta

Empty enclosures IEC 62208

CONV-B2000 Conversion Frame Installation / Inspection Manual Approved Under Dispenser SCCS (Spill Containment & Control System)

MUNICIPAL WATER PRODUCTS OVERVIEW

Gemini switchboards for all applications

Your Source for Automation & Control Components. PREVENTS CONDENSATION with optional air ventilation element

Statik und Holzverbindung TWINLOC Statics and connector TWINLOC

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

KDL cable entry system

Söll GlideLoc Aluminium Ladders

Technical Data Sheet VENUS FLA SCM

Pumps. Everything flows quickly and efficiently. The pump program from Wacker Neuson.

Product Data For FARNELL

Outdoor system solutions

Original operating instructions. Transit silo. Model. Transit silo

Polyester enclosures CP series

Mini amateur football ground goals, street hockey goals, mobile, fully welded

MEILLER Roll-Off Tipper

Enclosure. 10 Enclosure SOHO-2A./GL/ZS. Technical Specifications. Dimensions (mm) Scope of Delivery

GETO Megaport II Flush rear doors

Isolating transformer ES710

Cable Glands & Accessories

Wedge clamps

SCHÄFER IT-Systems The specialists for IT infrastructure

Pro-Line II Filing Frame

19 floor rack with steel door

Then all roads lead to LACONT!

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CONDUFIX Cable protection system. Protective conduits Connection fittings Connection manifold 90 -flange System holder Cable assemblies

siemens.com/mobility Avenio a rapid ride as tram or light railway Details about vehicle and technology. Avenio fits your city.

The Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation

ABOUT KJN ALUMINIUM PROFILES

Installation and maintenance instructions for the GRAF Universal External and internal Filter 3

Die changing technique

Hoses for the Agricultural Industry. Hoses & Connection Systems for demanding applications in the Agricultural Industry


XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

Gree Genuine Accessories

Product card User manual. KP Strong Safe

EASYBOX Series. Weather-proof enclosures

Always a little more flexible: häwa enclosures. Industrie 4.0

TECHNICAL APPLICATIONS. Metalpak Sb200

E2/000 Series

BOXES, ENCLOSURES, SHELTERS & KIOSKS FOR SOLAR APPLICATIONS

Dynamic Elements Linear Slides Mechanical Drive Elements Accessories for Mechanical Drive Elements

Voice Boxes, Cabinets

01 Product overview KT series order picking trolleys MultiPick trolley Pick and Pack Order picking container

Singular and rows of racks in steel and stainless steel, PC racks. Server and distribution rack systems, enclosures and housings

EN. Cupboard Trolleys. Versatile Innovative Excellent.

Designed to... ENDURE. IP65 LED luminaire

Wall-mounting steel enclosures suitable for any CRN and CRNG application

Selection BASIC LINE BASIC LINEPLUS

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

ENYSTAR Load Centers up to 250 A

SIMOTICS GP Frame sizes 80 and 90

Telecommunication rack systems Harju Elekter Teletehnika

Table of Contents COOLMANT. 2.0 Table of Contents

GENERAL CHARACTERISTICS

I-BRICK. High quality LED from Samsung. Curve shaped design. Vandal proof protective cover. Visual comfort. Available in 2 sizes.

SCHÄFER IT-Systems The specialists for IT infrastructure

Drive technology for the chemical industry. chemical INDUSTRY

PALAZZO Royal The premier class

Differential-Pressure Flow Meter

SINAMICS S120 Cabinet Modules Application Shaft Generator Drive

31-SDMS-02 REV. 01 SPECIFICATIONS FOR

Kaedra Weatherproof DIN Type Enclosures

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Transcription:

siemens.com/mobility Cabinets and lightweight bases for signal controllers of the Cxx family

N-series plastic cabinets N as in new! The new controller cabinets made by Siemens are simply called N-series The new cabinets of the N-series are made from high-quality plastics and are suitable for all signal controllers of the Cxx family. They are available in two sizes: Size 1 (Type 1N) and size 2 (Type 2N). The controllers of the Cxx family fit perfectly into the N-series cabinets! For each type, several variants can be configured by combining the cabinet with different control unit provisions and lock systems (see below). A special installation kit allows the coupling of two cabinets to form a single unit (for instance 3N = 2N + 1N). Depending on the type and actual distance of the existing bases, spacer plates of different thicknesses may be necessary. The older M-series controllers (MR, MF, MSF, MSK, MSL, MS-Plus 1 and MS-Plus 2) all require L-series cabinets (the corresponding brochure is available under the order number A24705-X-A497-*-04). With control unit compartment, as required The N-series cabinet types TG, TL and TR come equipped with a compartment for a control and display unit integrated in the door. The control unit door is also fitted with a cylinder lock. Four different variants of the N-series cabinets are available: Without compartment for the control and display unit 1N/2N With door-mounted compartment for the command and display unit (G door) 1N TG/2N TG With the control unit compartment integrated in the left side panel 1N TL/2N TL With the control unit compartment integrated in the right side panel 1N TR/2N TR Locks, keys and locking systems N-series cabinets are available with single (ES) or double (DS) locking systems for the doors. ES variants can be equipped with only one half-profile cylinder lock, DS variants can accommodate two such locks. A cabinet with a double lock can have two separate security locking systems installed. As a standard, every cabinet comes with one respectively two halfprofile cylinder(s) installed in the locking system(s) and one key for each lock. It is also possible to order the product without cylinders and keys. A double lock is equipped with an ad ditional dummy cylinder, which the customers can replace on site with their own half-profile cylinder, if desired. G lock: For the controller door of 2N cabinets comes with matching G key E lock: For the power utility door (E door) of 2N cabinets, comes with matching E key E/G locks: For door of 1N cabinets, comes with matching E and G keys P lock: For control unit doors (if applicable), comes with matching P key As an option we can also provide a universal key (X key) that fits all lock types. Please order separately. Weatherproof, low-maintenance and environment-friendly! Our N-series cabinets are made from glassfiber-reinforced (GFR) polyester and are completely recyclable, i.e. the materials can be reused in the production process. The external surface is extraordinarily weatherproof, requiring little maintenance. The central locking system possesses a three-point sliding-bolt mechanism to give the doors sufficient contact pressure against the cabinet walls. 2

Type 1N cabinets The locks are securely covered by a flushmounted, swiveling protection plate. The handle can only be pulled out when the lock is unlocked. The cabinets can be mounted on all bases compliant with the dimensions specified in DIN 43629, Part 1. This allows for the direct replacement of old M-series controllers installed in L-series cabinets with CxxV controllers mounted in N-series cabinets, without any construction work. When the cabinets are to be installed right next to each other, certain adaptations on the cabinet or the base may be necessary, depending on the base type and the formerly used cabinet type. Coated foam seals fastened all around the cabinet edges protect the interior against the intrusion of dust and splash water, in compliance with IP 54. On request, we can also provide cabinets meeting IP 55 requirements. An internal sealing layer integrated between the cabinet floor and the base seals the cabinet interior off against rising damp from the soil. The cabinet roof ensures adequate dust proofing while leveling out changes in atmospheric conditions, preventing condensation on the installed controller components. 180 Sturdy workmanship, perfected mechanism A catch mounted inside the cabinet permits the user to prop the G door open, if required. 270 110 0 A large pouch fastened on the inside of the G door can accommodate the manual and other equipment documents. The roof panel of the N-series cabinets does not jut out over the side panels, allowing the side-by-side installation of several cabinets on a combination lightweight base. 806 Dimensions in mm 3

Type 2N cabinets An easy-to-mount plastics floor panel with pre-molded cable entries forms the floor of the cabinet. On the left side there is an entry for the mains supply cable (Ø 30 to 50 mm). The collective inlets in the center of the panel can accommodate about 40 five-core ground cables. Each cable entry is sealed with a rubber cover, in which an opening of the required size can be cut with a suitable cutter. We recommend the use of a commercially available sealing compound to seal the opening after the introduction of the cables. 160 180 110 0 270 250 145 250 300 1136 380 Dimensions in mm 4

Type 3N cabinets Various cabinet combinations (e.g. 1N + 2N or 1N + 1N etc.) are available on request to accommodate additional customer-specific equipment, for instance special distribution panels or specific electric utility compartments. Attention! Some dimensions have been changed The drawing below indicates the dimensions of the base for a 3N cabinet. The most important aspect is the exact distance between the screws used to secure the two cabinets to the base. For the new 3N cabinets, this distance is 124 mm. In case the cabinets are to be installed on existing bases that are very close together, it may be necessary to create elongated screw holes and offset the cabinets accordingly during installation. It may be necessary to install spacer plates between the cabinets. * 8 1136 806 110 0 1020 690 124 10 10 Mitras base, size 2 Mitras base, size 1 1116 786 Top view of the cabinet floor installed on a Mitras base 380 160 Standard side panels without elongated holes 160 * Note: Please use spacer plates between adjacent cabinets. 58 Fixation width of size 2 cabinet 1020 Fixation width of size 1 cabinet 690 58 Dimensions in mm 5

Mounting the controller How to install a CxxV controller in a 2N cabinet 1. Unfasten and remove the fixing screws a. e 2. To center the floor plate c, screw in the setscrews b (usually DIN 551 M12 60, but for 3N cabinets, M12 80 screws have to be used because of the spacer plate). 3. Place the floor plate c on the base d. Make sure it is aligned. 4. Place the cabinet with the mounted CxxV controller e on the base. f 5. Remove the setscrews b on the left side and fasten the cabinet to the base with screws a. 6. Remove the fixing screws f, lift the CxxV controller slightly and move it approximately 50 mm to the left. 7. Remove the setscrews b on the right side and fasten the cabinet to the base with screws a. c 8. Move the CxxV controller back to its original position and fasten it with the fixing screws f. b a d 6

Technical data and components Properties Sealing Type 1N ES Type 1N DS Type 2N ES Type 2N DS Protection class The standard versions comply with IP 54 (protection against the intrusion of dust and splash water) according to EN 60529 IP 55-protected cabinets are available on request Materials Cabinet material Color Mechanical und electrical properties Fiberglass-reinforced polyester, Type 833.5 acc. to EN 14598 (DIN 16913), self-extinguishing Light grey, RAL 7035 Fully meets all mechanical and electrical requirements specified in EN 60439-1 (DIN/VDE 0660, Part 500) and EN 60439-5 (DIN/VDE 0660, Part 503) Design Base dimensions Variant Locking system (all doors pre-configured for the installation of a half-profile cylinder) Dimensions (h w d) in mm Weight (kp) Applicable standard Base size 1 Single door 1N ES: Single-lock E/G door 1N ES TG, -TR, -TL: Single-lock E/G door, control unit door 1N DS: Double-lock E/G door plus dummy cylinder 1N DS TG, -TR, -TL: Double-lock E/G door plus dummy cylinder, control unit door 1110 806 380 approx. 32 DIN 43629 Base size 2 Double doors 2NO ES, -TG, -TR, -TL: Single-lock G door, double-lock E door, incl. locks and keys 2N DS, -TG, -TR, -TL: Double-lock G door, double-lock E door, incl. locks and keys 1110 1136 380 approx. 43 DIN 43629 Cabinet components* 1N cabinet (GFR polyester) 2N cabinet (GFR polyester) Order number Metal rear panel Yes Yes C24734-A16-C125 Mounting plate for electric utility compartment Yes Yes C24734-A16-C59 *Other special parts on request. 7

Lightweight base C24324-Z5-C2/-C4/-C9 A range of different lightweight bases from various manufacturers are available for the installation of signal controllers. As the bases must provide a solid foundation for the GFR polyester cabinets, the following aspects have to be considered when selecting the appropriate base: The stability of the base depends on the size of its anchors and its height. The specific soil characteristics as well as the local frost line and the height of the base all are factors influencing on the reliability of the foundation. In Central Europe the frost line to be expected requires the installation of bases with a minimum height of 1200 mm. For these reasons, the lightweight bases described below are the most suitable for the installation of controller cabinets. As the footprint width of the N-series cabinets corresponds exactly to the width of the bases, the installation of combination cabinets (3N, 4N, etc.) requires the corresponding bases to be installed directly adjacent to each other. For this purpose, the pedestals of the base can be omitted. 1200 Base C24324-Z5 for cabinet type Weight Variant 75 275 430 75 430 -C2 -C4 -C9 1N 2N 2N + 1N 33 kg (approx.) 35 kg (approx.) 70 kg (approx.) Self supporting; screwed; material: foamed polycarbonate 270 160 540 (124) 1020 690 1120 79 0 1934 Base dimensions (approx. values) Size of base for cabinet type Base height above ground Height Width Depth 1 2 2 + 1 1N 2N 2N + 1N approx. 330 approx. 330 approx. 330 1200 1050 540 1200 1380 540 1200 2210 540 8 Combination lightweight base C24324-Z5-C9 for 3N cabinet (2N + 1N), dimensions in mm Delivered as unassembled set

Lightweight base C24324-Z6-C3/-C4/-C5 N-series cabinets fit on all common lightweight bases. The new cabinets can be installed on all hitherto available bases of all sizes, so the replacement of an old L-series cabinet does not require any construction work. Note: When using a spacer plate, please choose M12 80 screws! Base C24324-Z6 -C3 -C4 -C5 for cabinet type Weight Variant 1N 2N 2N + 1N Base dimensions (approx. values) 33 kg (approx.) 35 kg (approx.) 70 kg (approx.) Self supporting; screwed; material: Polyester, 25% glass fiber, color: light grey, comparable to RAL 7038 408 260 240 160 1258 1020 124 690 Size of base for cabinet type Base height above ground Height Width Depth 1 2 2 + 1 1N 2N 2N + 1N approx. 330 approx. 330 approx. 330 1260 940 450 1260 1270 450 1260 2090 450 1116 786 2027 Delivered as unassembled set Combination lightweight base C24324-Z6-C5 for 3N cabinet (2N + 1N), dimensions in mm 9

Installation of lightweight bases Cabinet For the installation of the base, please refer to the instruction leaflet supplied with the base. Here we provide a short overview for clarity s sake. Height D Ground level 1. Excavate an installation pit suitable for the size of the base. 2. Level the bottom of the pit. For heavy soil types, prepare a bed of compacted gravel or sand. For light soil types, prepare a bed of lean-mix concrete. 3. Lower the base into the pit and align it vertically and horizontally (base protrusion D above ground level). 4. Install the cables (in cable conduits, if necessary). Provide strain-relief clamps for the cables. Gravel/sand or lean-mix concrete bed 5. Replace soil from alternating sides and compact it inwards and outwards at intervals. 6. As the last step, fill the cavity of the base with sand. Assembly jig Strain-relief clamp Profile rail Sand layer Ground level Attention! When installing a cabinet in a wall recess or close to other solid building elements (for instance a garden wall), make sure to factor in the front and rear overhang of the cabinet over the sides of the base (generally 25 mm). Gravel/sand or lean-mix concrete bed D = Protrusion of the base above ground level (The lower edge of the removable front panel must be 30 to 50 mm above ground level) 10

Mounting the N-series cabinet onto its base e.g. 2N cabinet Power utility compartment Controller compartment Floor plate Protrusion D of the base (the lower edge of the removable front panel must be 30 to 50 mm above ground level) ~30 50 ~30 50 Cabinet overhang Profile rail (part of the base) Strain-relief clamp for cable Insert the two support rods enclosed in the package before compacting the soil Connection to grounding strap ~30 50 Provision for mounting an equipotential busbar Sand filling as top layer inside the base Commercially available plastic conduit elbow NW 110 for cable Compacted soil The number of conduit elbows depends on the number of signal control cables to be installed Example: Installation of a 2N cabinet on a size 2 lightweight base (dimensions in mm) Use only lightweight bases with a two-part, removable front panel and integrated profile rail. 11

Siemens AG Infrastructure & Cities Sector Mobility and Logistics Division Road and City Mobility Hofmannstrasse 51 81379 Munich Germany Siemens AG 2012 All rights reserved Printed in Germany DEI 73/45897 313686 PA 12123. Dispo No. 22300 K-No. 7599 Order-No. A19100-V350-B102-V1-7600 The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in every individual case at the time of closing the contract. www.siemens.com