USER S MANUAL. For Battery-Powered Fence Controllers. Part I: Fence Controller Installation. Part II: Electric Fencing Basics

Similar documents
USER S MANUAL. For Solar-Powered Fence Controllers. Part I: Fence Controller Installation. Part II: Electric Fencing Basics

Before You Start... p. 2 Fence Controller Installation... p. 4 Fence Controller Operation... p. 10 Model 8200 Installation/Operation... p.

Before You Start... Fence Energizer Installation... Fence Energizer Operation...

PW50S Solar PoWered electric Fence energizer

PORTABLE CORRAL KIT INSTALLATION INSTRUCTIONS

Safety Sentry Electronic Breakaway Switch

Mains Powered Energizer

Fencing Systems. Mark Kennedy NRCS State Grazinglands Specialist (Retired) Kennedy Grassland Services, LLC

Compressor Clutch Replacement Procedure

Utility Controller Hand Air Operated

WARNING. Instructions for Guidelights and Chargers. How SnapPower Products Work

Compressor Clutch Replacement Procedure

Model E600 Tarping System

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

Installation Instructions for Drapery System Drapery

INTELLIGENT FENCING FOR THE COUNTRY

12 Volt Utility Controller for 4, 6, or 8 Brakes No

User s Manual and Operating Instructions

FLEXIBLE 5 RAIL. Electric Hot Rail combines the high tensile safety of Centaur with the added security of an electric fence.

TB Series Brakes Tension Control System

Do-it-Yourself Electric Fence System Planning Guide

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Illumifalls Patio Pond

855-EBFENCE. Installation Manual. Safe, Secure, Simple. Permanent Electric Fencing ( ) Highly Visible Pure Copper & Polyester Braid

US Patent 0540, 400 Other Patents Pending. Read this manual completely before assembling and riding our PET PRO-FLEX 500. Always wear a Helmet!

Table of Contents. Technical Information Warning Statement

i n s t r u c t i o n m a n u a l

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

THUNDERBIRD Solar Electric Fence Energisers. S20 / S20B / S40 / S40B / S79 / S150

FADE Series Wall Axial Fans

Submersible Pond Pump with UV 800 Gallons Per Hour

INSTALLATION INSTRUCTIONS

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Electric Fence Energizer Installation, Operating and Warranty Instructions WARNING:

Electric Fence Energiser Manual

MGG Solar Powered Electric Fence Energisers Models S200 and S500

Warning Statement Read Before Riding

Electromagnetic Particle Brakes Model: PRB-H

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Warner Electric UNIBRAKE Motor Brakes

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

CRD610 Automatic Fitting Inserter

User s Manual. Complete Off-Grid Solar Kits (100 to 600 Watts) Complete Off-Grid Solar Kit Manual Revision 1.0

Submersible Waterfall Pump 1200 Gallons Per Hour

USER MANUAL. Delta Battery Energizer WARNING: READ ALL INSTRUCTIONS. speedrite ELECTRIC FENCING FOR THE SERIOUS FARMER

Electric Fence Design & Supply Guide. Place Store Label/Logo Here

INSTALLATION AND OPERATION MANUAL

Installation & Operations Manual

ELECTRIC FENCE PRODUCTS ENERGIZER INSTALLATION AND USER MANUAL

ESE Series Cast Iron Sewage Pumps

G500REC Manual Covering System for Containers

Motorized Stainless 2-Way Valves

Mechanical Filter Box Kit

Heavy-Duty Welding Fabrication Table

INSTALLATION INSTRUCTIONS

HALLMARK INDUSTRIES INC

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Installation Instructions

Deterring Bears with Electrified Fencing:

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

AT Clutch Major Service Sizes 25, 55, 115

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

MTB II Modular Tension Brakes

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Model RP310 Owner's Manual & Installation Instructions

Energizer Installation & Operation Instructions

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

StormPro BA Series Sump Pump

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

RANGE HOODS USER INSTRUCTIONS

II DISTRIBUTION & SUBSTATION TYPE C

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Installation Instructions

Installation Instructions

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

CRD600 Automatic Fitting Inserter

Installation Instructions GOOSENECK MOUNTING KIT Toyota Tundra

EASY CONNECT CRANE KIT Festoon Conductor Systems

INSP-3 Wiring Inspection Tester

Kompensator External Low Voltage Heating Cable System

ELECTRIC SAFETY COATED HIGH TENSILE WIRE

Premium Pond Pump 330 Gallons Per Hour

Mechanical Filter Pump Kit Up to 500 gallons

Installation Instructions

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

Pontoon and Tri-Toon Bunk Assembly Instructions

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Installation Instructions

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

Cast Iron WARNING CAUTION. CAUTION Some parts may contain sharp edges especially as noted in manual. Wear protective gloves if necessary.

SPECIFICATIONS GENERAL SAFETY RULES PERSONAL SAFETY. Save This Manual TOOL USE AND CARE WORK AREA

Electromagnetic Particle Clutches and Brakes Models: POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 P Performance Manual

Installation, Operating & Maintenance Manual 30P Planetary Winch

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Transcription:

USER S MANUAL For Battery-Powered Fence Controllers Part I: Fence Controller Installation Before You Start........................... p. 2 Fence Controller Installation..................... p. 4 Fence Controller Operation.................... p. 10 B10LI Installation......................... p. 11 B10LI Operation.......................... p. 18 Part II: Electric Fencing Basics Electric Fencing Basics................... p. 19 Electric Fence Components................ p. 20 Grounding System.................... p. 22 Fence Posts........................ p. 24 Insulators......................... p. 26 Fence Wire........................ p. 27 Gate Openings...................... p. 29 Lightning/Surge Protection................ p. 30 Electric Fence Design................... p. 32 Testing/Troubleshooting.................. p. 37 Fence Controller Warranty................. p. 40 SAVE THESE INSTRUCTIONS

Before You Start All Zareba brand pulse-type electric fence controllers meet Underwriters Laboratories (UL) standards for safety. WARNING: Read ALL these instructions. Only use electric fence controller products for the purpose intended as defined in this manual. WARNING: Never run more than one fence controller on the same fence line at one time. The pulse time between the fence controllers will be too close together and could be hazardous to animals and people. It could also damage your fence controllers. WARNING: Install fence lines powered by separate fence controllers far enough apart to prevent contact with both fence lines at the same time. Simultaneously touching two fences powered by separate energizers could be hazardous. WARNING: In brushfire-prone areas, turn the fencer off on extremely dry days. For backup, be sure others know how to disconnect the fence controller. Also, never disconnect wires or approach a fence during lightning storms. WARNING: Do not operate fence controllers near any combustible materials including gasoline, kerosene and cleaning fluids. WARNING: Never electrify barbed wire or similar fence types where an animal or human may become tangled in the fence or caught against the fence. WARNING: To reduce risk of electrical shock, do not remove the fence controller cover. Refer to service personnel. - 2 -

WARNING: Check local zoning laws for electric fencing guidelines in your area. Also check with local utilities before digging to identify any buried cables or natural gas lines. Tools Required Wire cutter/stripper (part no. FWC-1) Flathead and phillips screwdrivers Adjustable wrench Voltage tester (part no. DEFT-1 or RSVT8) Other Required Components Two lengths of 20 KV insulated hook-up wire (one long enough to connect fence controller to ground system and one long enough to connect fence controller to fence line) Fence line connector (part no. 07110-96 for steel or poly wire; PRS2 for poly rope; or PTCC1 for poly tape) 6- to 8-foot ground rod(s) (part no. GR8 or 07104-96) Ground rod clamps one per ground rod (part no. CGR1 or 07105-96) - 3 -

Fence Controller Installation NOTE: For model B10LI instructions, go to page 11. Overview of Installed Fence Controller Fence connection Ground connection 6- or 12-volt deep cycle marine battery - 4 -

STEP 1: Mount Fence Controller IMPORTANT: Mount inside or in a waterproof enclosure Inside installation Outdoor sheltered installation Single screw mounting Double screw mounting - 5 -

STEP 2: Connect Ground and Fence Terminals 1½ 20KV hook-up wire Your fence controller will have one of two types of terminals strip wire and connect as shown below or Connect hook-up wire to GROUND terminal Connect hook-up wire to FENCE terminal - 6 -

STEP 3: Connect to Ground System Ground rod clamp (part no.07105-96 or CGR1) Hook-up wire from fence controller Hook-up wire to other ground rods Ground rod (part no.07104-96 or GR8) NOTE: Connect additional ground rods with hook-up wire and ground rod clamps Check ground system reliability IMPROPER GROUNDING WILL AFFECT THE PERFORMANCE OF YOUR FENCE CONTROLLER! See page 22 for more information about proper grounding. Tip: The fence controller must be grounded sufficiently for the system to work effectively. Improper grounding can also cause interference on telephone lines, radios and television and could invalidate your warranty. - 7 -

STEP 4: Connect to Fence Line Aluminum/Steel/Poly wire connection Part no. 07110-96 Poly tape connection Part no. PTCC1 Poly rope connection Part no. PRS2 Check fence system reliability IMPROPER CONNECTION POINTS WILL AFFECT THE PERFORMANCE OF YOUR FENCE CONTROLLER! Make sure splices and insulators are sound and secure. - 8 -

STEP 5: Power Fence Controller WARNING: Never connect a battery powered fence controller to an AC power supply. 2 1 Red (+) Black ( ) 3 4 NOTE: Fence controller will be producing voltage at this point to avoid shock do not touch fence terminal or fence wire. 6- or 12-volt rechargeable deep cycle marine battery (low impedance models require 12-volt battery) - 9 -

Fence Controller Operation Fence OK light flashes when voltage is on fence line Ground terminal connect to ground rod Fence terminal connect to fence line - 10 -

B10LI Fence Controller Installation Overview of Installed Fence Controller Option 1: Connect to fence line via 20KV hook-up wire Fence connection 6- or 12-volt deep cycle marine battery, or four, D-Cell batteries Ground connection Option 2: Connect to fence line directly Fence connection Fence line 6- or 12-volt deep cycle marine battery, or four, D-Cell batteries Ground connection - 11 -

STEP 1: Connect to Battery WARNING: Never connect a battery powered fence controller to an AC power supply. NOTE: Ensure switch is in the OFF position. Option 1: Connect to 6- or 12-volt battery 1 2 Red (+) 3 Black ( ) 5 4 6- or 12-volt rechargeable deep cycle marine battery - 12 -

Option 2: Install four, 1.5-volt/D-Cell batteries 1 2 3-13 -

STEP 2: Mount Fence Controller/Connect Ground NOTE: B10LI does NOT need to mount in a waterproof enclosure 1½ Strip 20KV hook-up wire and connect as shown The B10LI can mount on a rod post or directly on a ground rod. If additional ground rods are needed, connect hook-up wire to GROUND terminal. Ground rod (part no.07104-96 or GR8) Ground rod clamp (part no.07105-96 or CGR1) To other ground rods Check ground system reliability IMPROPER GROUNDING WILL AFFECT THE PERFORMANCE OF YOUR FENCE CONTROLLER! See page 22 for more information about proper grounding. Tip: The fence controller must be grounded sufficiently for the system to work effectively. Improper grounding can also cause interference on telephone lines, radios and television and could invalidate your warranty. - 14 -

STEP 3: Connect Fence Terminal Option 1: Connect to fence line via 20KV hook-up wire 1½ Strip 20KV hook-up wire and connect as shown Connect hook-up wire to FENCE terminal To fence line - 15 -

Aluminum/Steel/Poly wire connection Part no. 07110-96 Poly tape connection Part no. PTCC1 Poly rope connection Part no. PRS2 Check fence system reliability IMPROPER CONNECTION POINTS WILL AFFECT THE PERFORMANCE OF YOUR FENCE CONTROLLER! Make sure splices and insulators are sound and secure. - 16 -

Option 2: Connect directly to fence line Ensure metal bar makes solid contact with fence line Fence line Check fence system reliability IMPROPER CONNECTION POINTS WILL AFFECT THE PERFORMANCE OF YOUR FENCE CONTROLLER! Make sure splices and insulators are sound and secure. - 17 -

B10LI Fence Controller Operation Fence terminal connect to fence line Fence OK light flashes when voltage is on fence line Ground terminal connect to additional ground rods ON2 Setting (low power) for short fences maximizes battery life ON1 Setting (high power) for longer fences or animal training will reduce battery life - 18 -

Electric Fencing Basics Electric fencing is an easy-to-install system for containing animals or keeping them out. A short, safe pulse of electricity creates a psychological barrier that trains animals to avoid the fence. In order for the animal to feel a shock, the voltage produced by the fence controller must penetrate the animal s hair, hide and hoof. How Electric Fencing Works The system works when an animal provides an electrical path by touching the fence wire and the earth simultaneously. The electricity then passes through the animal, into the soil and back to the ground rods, which are connected to the fence controller. At that point the circuit is complete and the animal instantly receives an electrical shock. Tip: For permanent, high tensile fence installation instructions, refer to Zareba s High Tensile Electric Fence Guide available at zarebasystems.com. - 19 -

Electric Fence Components 1 Fence controller (page 4) 6 Gate openings (page 29) 2 Ground system (pages 7, 14, and 22) 3 Fence posts (page 24) 7 Lightning/ surge protection (page 30) - 20 -

5 Fence wire (page 27) 4 Insulators (page 26) - 21 -

2 Grounding System Overview of Grounding System An effective ground system consists of: (3) 6 to 8 ground rods (part no. 07104-96 or GR8) (3) ground rod clamps (part no. 07105-96 or CGR1) 20 KV insulated hook-up wire (part no. UGC50, UGC250, 1404-92 or 7090-92) Fence Controller Electric Fence Controller 20 KV insulated hook-up wire Ground rod clamps First ground rod must be driven within 20 of fence controller. 6' 10 ' 10 ' Copper or galvanized metal ground rods driven 6 deep, spaced 10 apart. See page 7 for detail on connecting ground system. Tip: Watering or sprinkling the soil around the ground rods in dry weather will improve ground system performance. - 22 -

Grounding in Dry or Frozen Ground Fence controller Hot fence wire Ground return wire Hot fence wire Animal makes contact with BOTH hot and ground wire to recieve shock Standard ground system Additional ground rod every 1,300 In dry, sandy or frozen soil a typical grounding system is insufficient because electricity can not flow back to the fence controller. To compensate, create a ground wire return system with one fence wire carrying electricity back to the fence controller s ground terminal. Run the ground return wire between hot/electrified wires and drive a 6-foot galvanized steel or copper rod every 1,300 feet. Regardless of the soil conditions, when the animal contacts the hot and ground wires simultaneously, they will feel a shock. Tip: Because the animal must contact the hot and ground return wire SIMULTANEOUSLY, we recommend these two wires be spaced within two to three inches of each other. WARNING: Do not install ground rods within 50 feet of a utility ground rod, buried telephone line or buried metal water line, as they may pick up stray voltage. Ground Ground Installation Installation Around Around Buried Metal Buried Metal Fence Controller Utility ground Water tank 50 ' Ground rods Water pipeline (or other buried metal) - 23 -

3 Fence Posts Fence posts fall into two categories: corner/gate posts, which must withstand tension; and line posts, which simply support the fence line between corner/gate posts. Post material varies and should be selected by fence type. Electric fencing will usually use fewer posts than conventional barbed or woven-wire fencing, making it less expensive and easier to install. Most posts are spaced 12 20 feet apart depending on terrain and animal being controlled. Post Spacing on Hilly Terrain Posts should be perpendicular to the slope of the terrain Don t try to space posts evenly. In level terrain, posts can be spaced farther apart; for uneven terrain, a post should be placed at high and low points; and on hillsides, posts should be installed perpendicular to the slope. This keeps the wire at the proper height and prevents it from binding on insulators or clips. - 24 -

Post Selection Guide Post Type: Wood Post Plastic Step-in Post Steel T-post, U-post, Y-post Fiberglass T-post/ Rod Post Metal Rod Post Used for: Corner Posts X X (limited) Line Posts X X X X X Use With Fence Type: Portable X X X Semi- Permanent X X Equine X X X X X Permanent High Tensile X X - 25 -

4 Insulators Insulators isolate the electric fence wire(s) to prevent shorting and electric current leakage, while also keeping the wires properly spaced. Select your insulators to fit the type of post and fence wire you are using. We recommend Red Snap r plastic insulators designed for every type of post wood, T-posts, rod, corner, or chain link fencing. These insulators are available with various front ends to accommodate your selection of steel or poly wire, poly tape or poly rope. Tip: To prevent energy drain, routinely check to ensure insulators are clear of cobwebs and that electrified wires do not touch posts. Installation of Corner/End Post/Gate Insulators Corner insulator End post/ gate insulator Staple Electric fence wire Nonelectrified wire Staple Electric fence wire Nonelectrified wire - 26 -

5 Fence Wire Electric fence wire carries the electrical current from the fence controller around the perimeter of the fence. Galvanized steel and aluminum wire carry electricity best. Poly wire, tape and rope have strands of conductive wire twisted or woven into the fabric and are ideal for electric fencing because of its ease-of-use, light weight and visibility. Tip: For equine enthusiasts, we recommend using 1½ inch white poly tape or ¼ inch white poly rope. They are highly visible, easy to install and safer than steel wire for horses. The height and spacing of the wires will vary with the animal being contained (or kept out). Always position one electrified wire at the animal s shoulder height; the animal will hit the fence with its nose, making it back up. Proper spacing of the wires for the animal controlled is more important than overall fence height. Proper Wire Height and Spacing When installing fence wire, pull wire taut to maintain the same height and spacing between the posts. Tip: To prevent energy drain, keep electric fence wire clear of vegetation or objects touching the fence line. - 27 -

To maximize power on the fence, good electrical connections and splices are critical. Splicing Techniques Metal Wire Step 1 Step 2 Never use loose or single-wrap splices Poly Wire Tie any simple knot such as a square knot. Strip back and cut poly strands leaving two inches of conductive wires exposed. Twist or pigtail wires together. Poly Rope (using part no. PRS2) Stagger ends of poly rope and tightly secure using poly rope splicer. Poly Tape (using part no. SBS4 or SBL4) Step 1 Step 2 Step 3 Make one-foot loop. Insert poly tape through center of buckle and slip closed end over the upright flange. Pull poly tape tight and over flange. - 28 -

6 Gate Openings Gate openings can be installed a variety of ways. Typically the same fence wire is used across the opening. If a metal gate or spring gate is used, 20 KV insulated hook-up wire should be used to carry the electrical current under the gate opening. NOTE: Refer to page 8 for information on how to make fence line connections. Standard Gate Installation 20KV insulated hook-up wire Line clamps Spring Gate Installation + Hot + Hot Metal Gate Installation + Hot + Hot + Hot + Hot + Hot + Hot - 29 -

7 Lightning/Surge Protection Lightning is one of the main causes of fence controller failure. If a storm is forecast, disconnect your fence controller from the fence in advance, and unplug if it is an AC-powered unit. Using a Zareba Cut-Off Switch (part no. COS1) is a simple way to quickly disconnect your fence controller. If you are in an area with frequent electrical storms, be sure to keep a spare fence controller for backup. WARNING: Never disconnect a fence controller or approach an electric fence during a lightning storm. WARNING: Risk of electric shock! Do not connect an electric fence to any other device such as a cattle or poultry trainer, as lightning striking a fence will be conducted to other devices. Zareba offers several products designed to help minimize damage from lightning: Lightning Constrictor (part no. LC1) A combination lightning diverter and lightning choke that installs between the fence line and the fence controller. Lightning Arrestor/Lighting Diverter (part no. LA1/07106-96) Helps protect fence controller from lightning by diverting strike into the ground. - 30 -

Storm Guard (part no. 01667-92) Helps protect fence controllers rated at 1 joule of energy output or greater from lightning strikes. Spring Gate Kit (part no. SG1) Spring coil helps to dissipate lightning surges. AC Surge Suppressor (part no. 1549-96) Protects AC-powered fence controllers from power surges up to 6,000 volts. Tip: While lightning protection devices can reduce damage by up to 75%, no device provides 100% protection from lightning. - 31 -

Electric Fence Design Design Your Fence Now that you understand how each component works in your fence, sketch your fence layout to get a count of materials you ll need, including number of posts, wires, insulators, gate openings, etc. Tip: An electric fence line does not have to be constructed in a continuous loop; it also works effectively when dead-ended. Fence controller Corner posts Barn Pond Gate Line posts - 32 -

Estimate Your Electric Fence Supplies Use the chart below to get a rough idea of what you ll need for different size enclosures. Tip: Visit zarebasystems.com to use our online Fence Builder TM. It will recommend the correct products in the correct amounts for your electric fence. 5 Acres 10 Acres 330 528 Total = 1,980 660 Total = 2,706 825 For a SINGLE wire fence with ONE gate opening: Posts (15ft spacing) 133 182 Line Post Insulators (25/bag) Corner Post Insulators (10/bag) Poly wire, tape or rope (1,320ft spool) 6 bags 8 bags 1 bag 1 bag 2 spools 3 spools Gate handle kit 1 kit 1 kit For a THREE wire fence with ONE gate opening: Posts (15ft spacing) 133 182 Line Post Insulators (25/bag) Corner Post Insulators (10/bag) Poly wire, tape or rope (1,320ft spool) 16 bags 22 bags 2 bag 2 bag 5 spools 7 spools Gate handle kit 1 kit 1 kit - 33 -

Fence Configurations By Species Tip: Electric fence systems can be built in any configuration as needed by the end user. The following pages show recommended voltage levels and wire spacings to safely contain different species. Voltage for Cows: 2,000 3,000 v Voltage for Bulls: 3,000 4,000 v docile cattle require fewer strands; determined bulls require 4-wiremore voltage 3-wire 40" total 5-wire 52" total 6-wire 42" total 1-wire 8" 6" 32" 42 total 20" 12" 6" 6" 6" Boundary fences Feed lots Deter predators Portable/temporary fences Voltage: 2,000 3,000 v high visibility for safety; use white 1½ poly tape 3-wire 40" total 4-wire 46" total 5-wire 52" total 1-wire 20" 16" 12" 36" 48 total Geldings and mares Mares and colts Stallions Portable/temporary fences - 34 -

Voltage: 4,000 5,000 v thick coats/determined animals require more voltage; 4-wire may need to deter predators 6-wire 42" total 8" 6" 6" 6" 6" 7-wire 70" total 1-wire 18" 24 total Less space between wires deters predators Taller fence to deter goats jumping Portable/ temporary fences Voltage: 4,000 5,000 v determined animals looking for food need 4-wire higher voltage 6-wire 42" total 8" 6" 6" 6" 6" 7-wire 70" total Voltage: 1,000 2,000 v wires need to be low to 4-wire ground to deter rooting 3-wire 24" total 8" 6" Less space between wires deters predators Taller fence to deter jumping Boundary fences - 35 -

Voltage: 1,000 2,000 v smaller animals require closer wire spacing and 4-wire wire close to ground 5-wire 16" total 4" 3" 3" Voltage: 700 1,000 v use to contain/deter or prevent jumping or 4-wire digging 24" total 6" 6" 6" 3" 3" Height/number of wires depends on size of animal 6" Height/number of wires depends on size of animal Retrofit existing fence with wire at top/bottom Voltage: 4,000 5,000 v easily trained, but thick coats require 4-wire more voltage 4-wire 46" total 6-wire 42" total Voltage: 4,000 5,000 v higher voltage needed; fence needs to deter 4-wire jumping/reaching under 15-wire 72" total 8" spacing 16" 8" 6" 6" 6" 6" 4" spacing Boundary fence Deter predators Boundary fences - 36 -

1 Testing/Troubleshooting Test fence line voltage regularly at the furthest point on the fence from the fence controller to ensure voltage is adequate for the animal being controlled. Adequate voltage reading fence line OK 2 Inadequate voltage Ensure power supply is sufficient (battery/ac power) If power OK, disconnect FENCE and GROUND wires from fence controller, then check voltage output by touching metal part of terminals with tester. Replace/repair battery or AC power to fence controller 3 If output is less than 5,000 volts* there is a fence controller fault. Call Zareba for assistance. * (2,000 volts for models 10ACRE, 20 ACRE, ACC2, 33C, RS3 or SP3) If output is normal (over 5,000 volts*), reconnect FENCE/GROUND wires Test ground system it should read less than 400 volts on ground rod. If over 400 volts, add extra ground rods or make them deeper. Test again/add more ground rods until ground system reads under 400 volts. Remember grounding is affected by soil conditions. 4 If grounding is OK, test the hook-up wire that connects the fence controller to the fence line. Disconnect hook-up wire from fence line and test. 5 Under 4,500 volts* Hook-up wire is leaking to ground. Ensure you are using 20 KV insulated hook-up wire. Replace and recheck. Poor hook-up wire connections Poor jumpers between lines Poor fence line splices/ conductors Over 4,500 volts* Turn off fence controller and reconnect the hook-up wire to fence line. * (1,500 volts for models 10ACRE, 20 ACRE, ACC2, 33C, RS3 or SP3) Fence line short or leak to ground Check fence line Leaking hook-up wire under gateway Very heavy vegetation against the fence line Metal object touching fence line Bad or incorrect insulator Fence line touching a fence post Faulty connections at gate openings If you cannot resolve the problem please call Zareba Systems at 800-800-1819. - 37 -

Regular testing and maintenance of your electric fence system is important to assure performance. We recommend Zareba voltage testers DEFT-1 or RSVT8 for this purpose. Tip: Testing voltage by touching the fence line with your hand or a weed is not recommended. In addition, if you do this wearing rubber-soled shoes you will NOT feel a shock. STEP 1: Test the Fence Line Check for adequate voltage at the furthest end of the fence line from the fence controller. STEP 2: Test Fence Controller Remove fence controller power source (unplug or disconnect from battery) and disconnect fence and ground wires. Power fence controller and touch metal bolts of ground and fence terminals with ground and fence prongs of tester. Electric Fence Controller If output is less than 5,000 volts*, there is a fence controller problem please call Zareba Customer Service at 800-800-1819. (*2,000 volts for models 10ACRE, 20ACRE, ACC2, 33C, RS3, SP3 or LIS3) - 38 -

STEP 3: Test Ground System 100 yards To fence controller (FENCE terminal) Short the fence using a metal bar or wire Push probe into ground To fence controller (GROUND terminal) Touch ground rod with tester. If reading is over 400 volts, grounding is inadequate. Add additional ground rods 6 feet apart connected by hook-up wire until reading is under 400 volts. STEP 4: Test Hook-Up Wire Remove fence controller power source (unplug or disconnect from battery) and disconnect hook-up wire from fence line. Power fence controller and then check hook-up wire as shown. Touch tester contacts to hook-up wire. To FENCE terminal STEP 5: Check Fence Components Walk your fence line and inspect all components. Insulators should be clean and not cracked. Fence wire should be properly spliced, not touching fence posts and properly connected at all points. Verify weeds, branches or other debris are not touching the fence line. STEP 6: If you are still getting inadequate voltage readings visit ZarebaSystems.com for further tips or call Zareba Systems customer service at 800-800-1819. - 39 -

Fence Controller Warranty 30-DAY FULL WARRANTY Zareba Systems guarantees your satisfaction. You can return product with its receipt to the place of purchase within 30 days for a full refund. Proof of purchase is required for a full refund. LIMITED WARRANTY This fence controller is warranted for one year from the date of sale to be free from defects of material and workmanship and from damage caused by lightning. Fencers that are equipped with the Storm Guard lightning protection module are warranted only when the Storm Guard is properly installed on the fence controller. Proof of purchase is required for warranty consideration, and may be returned to Zareba Systems or any of the Zareba Authorized Repair Centers for warranty repair. If no sales receipt has been returned, the date of manufacture will be used to determine the warranty period. Neither the full or limited warranty applies to any defect in the product caused by improper installation, misuse, tampering, neglect, moisture or any other reason not related to defects in material or workmanship of the product. The full and limited warranties are not assignable or transferable. It is for the benefit of and given only to the first consumer purchaser of the product, and shall not be for the benefit of nor given to any subsequent owners or any other user or to any person. The obligation of Zareba Systems under the limited warranty is only to repairing or replacing, at its option, any part of the product that is defective and is covered by the terms of this warranty. If any covered defect occurs during the warranty, return the product for replacement or repair, with freight prepaid, to any Authorized Repair Center or directly to Zareba Systems, 69 N. Locust Street, Lititz, PA 17543. There will be no further cost to you if it is a result of defects, failures or malfunction of the product. (Note: The following fence controller models can only be returned to the factory for warranty consideration: 601, 8574, A5, WD56, 30, 10 ACRE, 20 ACRE, 415, 410, 4444, 4612, 4465, 4309, 8565, 8555, 8612, 77, 98, S12, S100, 980, 57, S12, TCC2, ACC2 and 33B. Any model of fence controller not listed can be sent to any Authorized Repair Center or to the factory). UPON EXPIRATION OF THE FULL 30-DAY WARRANTY, ZAREBA SYSTEMS MAKES NO OTHER EXPRESSED OR IMPLIED WARRANTIES OF FITNESS OR MERCHANTABILITY OR ANY OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED; ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXCEEDS THE FOREGOING WARRANTY, IS HEREBY DISCLAIMED BY ZAREBA SYSTEMS. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. In no case shall Zareba Systems be liable for incidental, consequential, special or indirect damages of any kind. Any action for breach of warranty must be started within one year after the cause of action shall occur, and no such action shall be maintained which is not commenced within such a period. Some states, however, do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. If you have any questions about how to exercise your rights under the terms of either the full or limited warranty, you may call Zareba at 800-800-1819, email to info@zarebasystems.com or write to Zareba Systems, 69 N. Locust Street, Lititz, PA 17543-40 -

LIMITATION OF DAMAGES The directions for use of this product should be followed carefully. It is impossible to eliminate all risk inherently associated with use of the product. The effectiveness of Zareba Systems brands of fence controllers may depend on the effectiveness of connections, interruption of power source, accidental grounding of wires, weather conditions, or the manner of use or application, all of which are beyond the control of Zareba Systems or the seller. All such risks shall be assumed by the buyer. Zareba Systems warrants that this product is reasonably fit for the purposes referred to in the directions for use, subject to the inherent risks referred to above. Zareba Systems makes no other expressed or implied warranty of fitness or merchantability or any other expressed or implied warranty. IN NO CASE SHALL ZAREBA SYSTEMS OR THE SELLER BE LIABLE FOR CONSEQUENTIAL, SPECIAL OR INDIRECT DAMAGES RESULTING FROM THE USE OR HANDLING OF THIS PRODUCT. ZAREBA SYSTEMS AND THE SELLER OFFER THIS PRODUCT AND THE BUYER AND USER ACCEPT IT, SUBJECT TO THE FOREGOING CONDITIONS OF SALE AND WARRANTY WHICH MAY BE VARIED ONLY BY AGREEMENT IN WRITING SIGNED BY AN OFFICER OF ZAREBA SYSTEMS. Some states, however, do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. - 41 -

Notes - 42 -

Notes - 43 -

Woodstream Corp. 69 N. Locust Street Lititz, PA 17543 Contact us: ZarebaSystems.com info@zarebasystems.com 800-800-1819 Part # 0077368-002 Rev1