VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

Similar documents
4.30 [109] 5.43 [138] FCI FlexMASSter ST98 Series: The Best Value in a 8.00 [203] High Performance. Flange. Mounting Hole. Positioning to Split Flow

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

flow measurement solutions RIM10 series rotor insertion flowmeters

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Full Profile Insertion

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

Fluid Flow Conditioning

Air Flow Measurement Technologies

Introducing NJK Precision Airflow Measuring Stations

VERIS FLOW MEASUREMENT GROUP

NJK Precision Product NJK-02 Sensor Installation Guide

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

F-2600 SERIES INLINE VORTEX FLOW METER

KB Series self averaging pitot flowmeter for gas, liquids and steam flows

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Propeller. Flowmeter. Technology. For the Real World.

KRAL Volumeter - Turbine Fuel and Water Injection Measurement

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves

For Applications Demanding Precision and Efficiency, FloMax Nozzles Outperform All Others

Rosemount 285 Annubar Primary Element Series

Fundamental Training. Flow Con t


Silver Series Thermal Dispersion Airflow Measurement Technology

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes

Experiment No.3: Flow through orifice meter. Background and Theory

Armstrong In-Line and Insertion Vortex Flow Meters

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 2900 MIXER TO BE USED BY CNRL FOR BITUMEN VISCOSITY CONTROL Report R0. By Kimbal A.

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

Propeller Meters. Flow measurement solutions for water and wastewater

F-2500 SERIES VORTEX METER

FOR USE IN SOLUTION AIR HANDLING UNITS

F-2600 SERIES INLINE VORTEX FLOW METER

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Design and Application Details

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

LUBE OIL PUMPS. Critical Lubrication Service for: Bearings Seals Gearboxes. on... Gas & Steam Turbines Compressors Engines Starting Packages

Hydro-Flow Model 2200 Installation and Operation Guide B

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter

COUNTER CLOCKWISE FOR CLARITY (SEE MANUAL FOR SPECIFIC WATER & DUST TIGHT AP LOCAL ELEMENT ENCLOSURE ROTA FLAT PARALLEL TO FLOW.

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

Right Angle Nozzle Assembly

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

F-1500 SERIES INSERTION TURBINE FLOW METER

Fundamentals of Turbine Meters. Paul Honchar Sensus Metering Systems

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

ISO 9001 : Dual Plate Wafer Check Valves. API 594 Design API 598 Tested. Maximizing the Flow

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 APRIL 2004

Hydro-Flow Model 3100

Rosemount Orifice Series Differential Pressure Flow

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

SIGNET 7002 Vortex Flow Sensor ENGLISH

Double door, spring loaded, wafer check valve designed to protect your gas or liquid piping systems.

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Hoffer Engineering Guide for Liquids

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

INSTRUMENTATION & CONTROL TECHNOLOGIES (I&CT)

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

Process Industry. Diaphragm Seal Solutions

Model 5000 Vortex Meter

FE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT

Model 8800C Vortex Installation Effects English Rev. CA

DIGIFLO ELECTRONIC FLOWMETER

Model 1000 Vortex Meter

Technical Datasheet. HM AC Series. Turbine Flow Meters. for High Pressure Applications up to 1,400 bar

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

APCO ASU COMBINATION AIR VALVE

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

MODEL 1100 TURBINE FLOW METER

To ensure proper installation, digital pictures with contact information to before startup.

FUNDAMENTALS OF GAS TURBINE METERS Paul Honchar Sr. Product Manager Sensus 805 Liberty Boulevard DuBois, PA, USA 15801

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 SEPTEMBER 2001

Rosemount 8800 Vortex Installation Effects

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Ultra-Matic Air Valve System

LIQUID MEASUREMENT STATION DESIGN Class No

CONTROL VALVES QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Innovative Solutions

TURBINE FLOW METER SELECTION GUIDE

Model 1100 Turbine Flow Meter

Technical Datasheet. HM U Series. Turbine Flow Meters. for lubricating liquids

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Technical Data Sheet , Rev HB October Rosemount 8800 Vortex Installation Effects

Gold Series Thermal Dispersion Airflow Measurement Technology. Advantage. Installation, Operation and Maintenance Technical Manual GF1

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

200 Series Flow Meters

FCI ST75 Series Flow Meters

Transcription:

VORTAB FLOW CONDITIONERS For Flow Meters, Pumps and Other Flow Profile Critical Equipment Reduce flow meter straight-run requirements into just a few diameters Balance pump inlet flow to eliminate premature wear and cavitation Install after elbows, valves, pipe expanders or reducers and other flow disturbances Very low pressure drop technology

Flow Conditioners and Flow Straighteners Reducing straight-run requirements for flow meters, pumps and flow profile critical process equipment Straight-run is required in flow meter and pump installations to overcome the swirl, asymmetrical flow profiles and otherwise un-repeatable flow that is created by elbows, pipe expanders or reducers, valves, dampeners and other disrupters in the process pipe. In process piping systems, finding or adding a suitable amount of straight-run to accommodate the flow meters, pumps and other critical components is often impractical or un-feasible, either technically, economically or both. Flow conditioners, sometimes referred to as flow straighteners, are a practical and cost effective engineering solution to overcome this lack of available straight-run. Vortab Flow Conditioners Vortab flow conditioners were the first and original tab-type flow conditioners patented. They were immediately recognized by the flow engineering community for their unique ability to eliminate both swirl and flow profile distortions, all with a minimum amount of pressure loss (see table, P Equations, on page 4). The Vortab product line includes an extensive selection of configurations, and installation options ensure a Vortab solution matched to your application needs. Swirl Reduction & Profile Conditioning Tabs Swirl reduction is achieved by generating small vortices (swirls) opposite the main swirl resulting in swirl degradation. Profile conditioning tabs produce vigorous cross-stream mixing, which rapidly mixes faster velocity regions with slower regions. This mixing quickly produces a homogenous (i.e. conditioned) velocity profile. Combining anti-swirl with profile correction mechanisms also benefit equal distribution of particulates and temperature gradients. Static mixing is another side benefit of all Vortab products. Models VIS / VMR Model VIP Model VEL Profile Correction Tabs Swirl Reduction Tabs Profile Correction Tabs Combination Swirl Reduction/ Profile Correction Tabs Swirl Reduction Tabs Vortab flow conditioners eliminate swirl and cross-mix the flow stream to achieve a symmetrical, distortion-free, repeatable flow profile in just three (3) pipe diameters. For installation ease and application optimization, traditional Vortab flow conditioners are available in a complete spool piece pipe section (Models VMR and VSR), an insertion sleeve (Model VIS), or as a weld-in-place kit (Model VFK). Also available, and particularly well suited for pump and compressor applications, is Vortab s exclusive elbow section (Model VEL). With all models, in addition to their low pressure loss, the open tab design is non-fouling and will not trap dirt or be clogged by debris in the flow stream. Traditional Vortab models are for use in air, gas and liquid applications. Vortab VIP combines the science of tab-type flow conditioning with the installation ease and cost savings of an insertion panel type design. This new, patent pending design achieves Vortab performance in a simple flange mount or weld-in-place plate. Standard VIPs are available for pipe sizes 2 inch to 40 inch [51 mm to 1000 mm], and larger with special order. Today, VIP is only available for use in air/gas flow applications. Optimum performance is achieved when VIP is installed 3 d downstream of the disturbance and the flow meter installed 3 d downsteam of the VIP; however, VIP has been successfully installed with less than 3 d between the disturbance and the VIP, depending on the type of disturbance and flow rates. The Vortab Company has performed extensive tests at various disturbance-to-vip distances and can assist you with data and placement tradeoffs in your application.

For flow meters For flow meters to operate accurately and with repeatability, the flow profile at the flow meter must be uniform and repeatable. For many flow meter technologies the specified amount of upstream straight-run required can range from 15 to 40 pipe diameters. Additionally, flow meters with extreme low flow sensing and/or wide turndowns may experience natural changes to flow profile in the "transitional" flow between laminar and turbulent flow. 1 Vortab flow conditioner products are specified for use and successfully applied with flow meter technologies that include ultrasonic, vortex shedding, turbine, thermal dispersion 2, magnetic tubes, pitot tubes and more. Whenever the amount of pipe straight-run specified for the flow meter exceeds the processes technical and/or economic limits, or will experience transitional flow profile changes, Vortab flow conditioners can provide a solution. Vortab products can be shipped directly to a job site or flow meter supplier for them to perform a potentially necessary matched system calibration. To comply with these straight-run requirements, flow conditioners provide a technical solution that produce a uniform and repeatable flow profile in much fewer pipe diameters. While there are several flow conditioner technologies and designs which can be considered, engineering must then consider trade-offs in installation ease and cost, straight-run still required by the flow conditioner, ability of the flow meter to be calibration matched to the flow profile created, clean or dirty fluid, ability of the flow conditioner to overcome the specific type of flow disturbance(s) (e.g. swirl, velocity profile distortion) and very important, the amount of pressure drop created. Excessive pressure loss can create unexpected and undesired process re-engineering and, most certainly a proportional increase in energy costs to overcome. Unconditioned, distorted and swirling flow Unconditioned, distorted and swirling flow Without flow conditioning 15d to 40 d may be required Flow Meter Flow Meter 1 For more information please consult Vortab technical article/white paper Transitional Flow Effects on Flow Meter Measuring Accuracy, available to download at www.vortab.com 2 Fluid Components International (FCI) is Vortab Company s exclusive partner for use with thermal dispersion technology flow meters; FCI flow meters have been optimally designed for use with Vortab flow conditioners and FCI calibration laboratory will precision match the flow meter calibration to Vortab and Vortab VIP

For pumps, compressors and other flow profile critical equipment An unequal, imbalanced fluid flow force on the inlet of pumps and other critical process components can result in premature, unexpected and expensive failures. Like flow meters, pump and component manufacturers often require a specified straight-run to achieve a uniform and balanced flow entering the inlet of the pump and system, frequently as condition of their warranty. Pressure loss consideration All flow conditioning technologies will create some presure drop. Higher pressure drop creates additional engineering issues in the process' design and equipment sizing, and directly results in increased energy cost to overcome it. With Vortab flow conditioners, engineers are assured of the lowest pressure loss solution available. Unconditioned, distorted and swirling flow Uneven flow into pump inlet Pump P Equations Conditioned with Vortab VEL Symmetric, even flow into pump outlet Pump For Air at Standard Conditions (60 F, 0 psig) P = A x Q2 or B x m2 D 4 D 4 For Water P = C x Q2 or D x m2 or E x G2 D 4 D 4 D 4 P = pounds per square inch (psi) Q = volumetric flow rate in cubic feet per minute (cfm) M = mass flow rate in pounds per hour (lb m/hr) G = flow rate in gallons per minute (gpm) D = inside pipe diameter in inches Model Variable VIP VIS, VMR, VSR, VFK VEL A 1.06E-04 1.24E-04 1.86E-04 B 6.06E-06 6.11E-06 9.16E-06 C 9.45E-02 0.142 D 6.75E-09 1.01E-08 E 1.69E-03 2.54E-03 Vortab VEL installation at pump inlet

Vortab Model Summary Model VIP VIS VMR VSR VEL VFK Style Insertion Plate Insertion Sleeve Meter Run Short Meter Run 90 Elbow Field Kit Liquids Air/Gas Pipe Sizes Available 2 ʺ to 40 ʺ [50 mm to 1000 mm] 1 ʺ to 48 ʺ [25 mm to 1220 mm] 2 ʺ to 24 ʺ [50 mm to 610 mm] 2 ʺ to 24 ʺ [50 mm to 610 mm] 1 ʺ to 36 ʺ 36 ʺ to 96 ʺ [25 mm to 915 mm] [915 mm to 2440 mm] Round Pipes Materials of Construction Carbon Steel 316L Stainless Steel Hastelloy C-276 * * * * Installation/Mounting Between flanges or weld-in-place Between flanges or weld-in-place NPT(M), flanged, butt weld prep NPT(M), flanged, butt weld prep NPT(M), flanged, butt weld prep Weld-in-field * Special order VIP Insertion Plate Low cost, lightweight, easy to transport and easy to install insertion panel/ plate. The panel contains conditioning tabs and strategically engineered cross members. The VIP plate is designed for installation between flanges or weld-in-place. VIP is currently available only for use in air/gas applications. VIS Insertion Sleeve A 3 d long sleeve Vortab flow conditioner designed for inserting within an existing pipe. The sleeve is either tack welded in place or bolted between flanges with optional retaining wafer. Settling distance of 3 d is required after the VIS and prior to the flow sensor. Actual inside pipe ID is required upon ordering to ensure correct sizing. VMR Meter Run A fully integrated 7 d long spool piece section containing 3 d of flow conditioners, 3 d settling chamber, the optional flow meter tap point and 1 d downstream settling distance. Process connection options include flanges, NPT or butt weld prep. The flow element tap options include 3/4 inch NPT(F), 1 inch NPT(F), 1 1/4 inch NPT(F), 1 1/4 inch NPT(M),and 1 1/2 inch flanges. Other process and flow element connections can be provided by special order. VSR Short Run A 3 d long spool piece section containing just the flow conditioning elements. VSR is used when the installation location has the 3 d of settling distance before the flow element. VSR is ideally suited for retrofits and upgrade situations where an installed flow meter is not performing due to a lack of straight-run. Process connection options include flanges, NPT or butt weld prep. Other process connections can be provided by special order. VEL Elbow The only true isolating 90 elbow flow conditioner. Can be applied with flow meters and is ideal for use in tight installations with pumps, compressor and other critical process equipment requiring a stable flow profile and applications where an elbow inlet is typical. Process connection options include flanges, NPT or butt weld prep. Other process connections can be provided by special order. VFK Field Kit Kit containing Vortab flow conditioning and anti-swirl tabs aligned for on-site fabrication. VFKs are most often specified for use in large existing pipes and ducts at the installation site where a complete Vortab spool piece assembly is too large to transport and handle. VFK is supplied with detailed installation and welding instructions for on-site installers. VFK is available in straight or elbow configurations for pipe or duct sizes 36 inch to 96 inch [915 mm to 2440 mm].

Vortab World Class Calibration and R&D Laboratory The Vortab Company operates a world class flow calibration laboratory to verify and validate product performance and quality. This laboratory is home to more than 18 NIST traceable flow stands and is certified to meet the stringent standards such as MIL-STD 45662A and ANSI/NCSL Z-540. These flow stands are outfitted with high-speed, precision data acquisition systems and capable of flowing a broad range of fluids over wide flow ranges at various temperature and pressure conditions. Vortab R&D engineers utilize state of the art fluid dynamics and modeling tools such as SolidWorks Flow Simulation to thoroughly tests and prove designs, and assure flow conditioner performance. When Vortab products are ordered for use with Fluid Components International (FCI) flow meters, these same calibration stands are used to deliver a Vortab+FCI matched precision calibration. More than 18 precision flow stands to match NIST traceable fluids, process conditions, flow rates and line sizes specified in your application. Vortab VMR with flow element installed in optional tap Local Vortab Representative Visit Vortab Online: www.vortab.com 1755 La Costa Meadows Drive San Marcos, California 92078 Phone: 760-736-6114 800-854-9959 Fax: 760-736-6250 Vortab is ISO 9001 and AS9100 certified Copyright 2013 by Vortab Company. All rights reserved. Information subject to change without notice. 0113 3K Doc. No. 02MK011435 F