CSP Circuit Breaker Three Phase

Similar documents
Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

Figure 1. Two and Three-phase MagneX.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Horizontal Circuit Switchers

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

Medium Voltage Metal-Enclosed Switches

Horizontal Circuit Switchers

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

A. Submit manufacturer's literature and technical data before starting work.

SF 6 Gas Insulated Load Break Switch

Recommended Procedures

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

SURE TRIP RETRO KITS

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Medium Voltage Metal-Enclosed Switches

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Thermal-magnetic Miniature Circuit Breaker 4230-T...

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Design Standard. Purpose: Design Standard:

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4

Selective Coordination

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

IN2 Enclosed Switches and Circuit Breakers

University of Houston Master Construction Specifications Insert Project Name

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

LA Motor Protection. A South African Company to be Proud of

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

SURE-TRIP OEM RELACEMENT TRIP UNIT

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Copper Double Break Switch

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

18-I73E CAT REF.

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

MAGNETIC MOTOR STARTERS

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

15-I73E CAT REF.

MV Metalclad Switchgear 4760V-15000V 20KA-63KA. AC Power Circuit Breaker Rating Structure. Test Procedures for Power Circuit Breakers

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

CR193 Vacuum Limitamp* Contactors

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

A 1.2 kv class externally removable secondary bushing

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

SWITCHGEAR DIVISION PRODUCT PROFILES

14-I73E CAT REF.

Chapter 6 Generator-Voltage System

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

MINIATURE CIRCUIT BREAKER

3.2. Current Limiting Fuses. Contents

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Industrial Contactors CTX 3 3P 185A - 800A

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Effective March 2015 Supersedes S August 2012

Submersible Vacuum Fault Interrupters

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Extensible Unit - VCE2a

CONTROLLERS & MODULES EMERGENCY STOP & STOP CONTROL SAFETY LIGHT SCREENS

Transcription:

General Information : LR Breaker SQR Breaker LQR Breaker, HQR Breaker Wall-Mounting Type CSP Circuit Breaker Three Phase Three Phase CSP Circuit Breaker For Distribution Transformers General Information For Selection of Breaker Type ` Wall-Mounted R Breaker (Front View) Wall-Mounted R Breaker ( Side View) Wall-Mounted R Breaker (Back View) Wall-Mounted R Breaker (Isometric Side View) Designed & Licensed By ABB Power T&D Company P&A Power Products Inc. ISO 9001 March, 2000

Introduction Three phase CSP type distribution transformers require an internal three phase "CSP" breaker for proper operation. P&A manufactures a full line of three phase breakers; these are designated as the "R" series (LR, SQR, LQR and HQR) All have been designed for service under oil within the distribution transformer. The circuit breakers can handle continuous loads up to 1000 amperes and 480Y/277 volts. Technical Detail The CSP breaker is connected to the transformer between the low voltage winding and the secondary bushing's internal terminals (please refer to the schematic diagram shown in Figure 1). The connections are made so that the secondary load current flows through both the breaker bimetal and contact. This is necessary to properly monitor the secondary transformer current and load levels. The breaker is available with two auxiliary features: a signal light contact and an emergency control setting. The signal light contact is connected into the signal light circuit and is used to provide an early warning of transformer overload. The signal light operates on approximately 4 to 6 volts (14 volts optional), picked up by an auxiliary winding of consisting of one or two turns through the core. (The signal light contact is an optional feature of the circuit breaker and should be specified, if desired). The emergency control mechanism is a mechanical linkage inside the breaker which moves the breaker to a higher calibration of the temperature setting when placed into the emergency position. (This is also an optional feature and should be specified, if desired) Preliminary Breaker Selection In order to determine which basic breaker design is appropriate for the transformer, the transformer`s rated current is calculated and compared to the circuit breaker`s minal Current Rating (shown in table1); the minal Current Rating of the breaker, in most cases. should be equal to or greater than the transformer`s rated secondary current. The minal Current Rating is only used as a guide for the preliminary breaker selection. The breaker's current carrying parts are designed to accommodate significant transformer overload current above the minal Current Rating as predicted by ANSI standards. It should be noted that adjustments to this table may be appropriate for transformers not designed to ANSI standard. Once the preliminary selection is complete, calculations must be made to determine the specific technical details necessary to completely specify the breaker. All of the major technical and application parameters of the breakers are presented in Table 1. The R-series breaker is constructed using the unit pole concept. This construction method allows each pole of the breaker to operate independently. The advantage of this method of construction is that it allows the breaker designer to minimize the amount of mechanical work that must be done by the bimetal because the bimetal only has to work against one pole of the latching system. The R- series of breaker also features a low force latching and tripping mechanism, which further reduces the required bimetal mechanical work. Because of its intended application range, the LQR and HQR breaker always contains a magnetic trip element in addition to the thermal trip provided by the bimetal. General dimensional and mounting informations for the R-series of breakers are contained in Dimension Sheet series 44-882. Construction Details Each pole of the breaker is contained completely by a rugged glass reinforced molded thermoset polyester housing. The housing accurately locates all of the critical linkage and alignment points as well as provides the mechanical protection for all of the working parts of the breaker. The design of the R-series breaker isolates the bimetal from the contact toggle forces. This reduces the required bimetal force and increases the precision and repeatability of the breaker. Each pole of the breaker is mechanically linked through the trip arm pin and interlock bar to the other pole of the breaker. This mechanical linkage ensures that all poles of the breaker will open simultaneously regardless of which pole is the trip initiating pole. The breaker is manually opened, closed, and set via linkage which connects the external operating mechanism to the breakers operating handle. Contact Structure The breaker contacts are refractory type (coppertungsten or silver-tungsten) in order to withstand the high current arcing which occurs during fault current interruption. The contacts are silver plated to ensure reliable low resistance contact under all conditions.

Emergency Control Feature When the Emergency Control linkage is activated, the linkage rotates the calibration screw in the direction of increasing trip temperature setting. Thereby, in effect, recalibrating the breaker to a higher trip temperature. The amount of trip temperature increase is presented in Table 1. Add this value to the breaker's calibration temperature for the EC increased trip temperature. Frame Mounting The R-series breaker is mounted in an upright position; traditionally, on top of the core/coil superstructure. Sufficient electrical clearance must be provided; information concerning electrical clearances is given in dimension sheet series #44-882. The breaker operating lever, attached to the breaker, can be supplied on either the left hand side or the right hand si- de of the breaker. The hand side of the Breaker must be specified at the time of ordering. The hand side is determined by viewing the breaker from the lead end. The breaker is also available in a center operated version. Figure 1: Schematic Diagram-CSP Transformer Frame Mount Signal Light The signal lamp is a nominal 6 volt bulb (14 volts optional) with a screw base. The electrical circuit for the bulb passes through the center contact of the bulb into a crimp termination for attachment to the signal circuit on the inside of the transformer. The other side of the bulb's electric circuit passes through the bulb's threads into the lock nut and washer. The signal circuit depends on a reliable connection between the mounting boss and the tank ground circuit. CAUTION: Mounting The SQR, LQR and HQR breaker can only be mounted in the upright position because their internal magnet trip relies on the force of gravity to provide the reset action. Wall-Mounted Breaker The R-series breaker can be supplied in a unitized wall mount configuration. The breaker is preassembled to the external operating mechanism and all mechanical connections, including the opening and closing mechanism and emergency control linkage (if specified), are assembled at the factory. Installation to the transformer only requires that the wall mount assembly be passed through the transformer tank mounting hole and secured in place with its mounting nut. other mechanical assembly is required. The standard electrical connection between the winding and the breaker leads and between the low voltage bushings and the breaker leads are made to complete the basic installation into the transformer. When the signal light function is desired, the auxiliary winding connections between the signal light terminal and between the auxiliary winding and the breakers signal contact terminal must be made. Wall Mounted Mounting Boss The mounting boss is a zinc die casting with a yellow chromate seal coating. The mounting boss contains the main operating handle, the emergency control operating lever and the signal light. The mounting boss passes through the tank mounting hole (Approximately 2.25 inches or 57.2 mm ) from the inside and is secured to the tank with a rugged conduit type nut. The mounting nut is also a coated die-casting. The entire external portion of the mechanism has been designed for superior corrosion resistance and shows negligible effect after 1,500 hours of salt spray testing.

R Series Breaker Frame Mounting Main Operating Handle The main operating handle is fabricated from steel with a yellow chromate sealer over zinc plating for corrosion resistance. It is sealed into the mounting boss with a high temperature elastomeric gasket. The exterior portion of the operating handle formed into an operating eye with a one inch inside diameter. Emergency Control Operating Lever This lever is fabricated from the strength, corrosion resistant aluminum. It is also sealed into the mounting boss with a high temperature elastomeric gasket. Wall Mounted Breaker External Boss Assembly Sealing System As mentioned above, all shaft seals are high temperature elastomeric gaskets. The cylindrical seal within the signal light housing is also made form this material. The gasket, which seals the mounting boss to the tank, is fabricated from nitrile. CAUTION : Transformer Processing If the breaker is to be fixed to the transformer and then processed along with the winding, P&A should be consulted for recommendations. In general, it is acceptable for the breaker to be subjected to processing temperatures in the range of 125. After processing, the contacts should be cleaned to remove any oil residue. If a wallmounted breaker is to be processed, the signal light lens and gasket and the tank-mounting gasket should be removed prior to processing. These gaskets should not be subjected to the heat of processing. All internal seals are constructed of high temperature elastomers and may be processed. CAUTION : Large motor Loads Wall Mount Signal Light The signal lamp is a nominal 6 volt bulb (14 volt optional) with a screw base. The electrical circuit for the bulb passes through the center contact of the bulb into a crimp termination for attachment to the signal circuit on the inside of the transformer. The other side of the bulbs electric passes through the bulb's threads into the mounting boss. When the CSP transformer is connected to a large, dedicated motor load, special considerations must be observed. If the motor horsepower is equal to or greater than 50 percent of the transformer rated KVA, a special breaker must be used to prevent unnecessary breaker trips. Please consult P&A for further details.

3 Pole Wall-Mounted Breaker R Series Breaker Bimetal Temperature The equation governing the temperature rise in the bimetal due to the flow of load current through it is given by: LR/SQR/LQR/HQR breakers :Θ b = JI 2 Where: Θ b = Bimetal temperature rise due to current in J = Bimetal Ampere Response Factor in /A 2 I = Current Flow through the Bimetal The total temperature of the bimetal (Tb) is given by the following equation: Tb = To + Θ b Application Data Application information is contained in the dimension sheets, which are supplied as part of this technical information. These dimension sheets should be carefully studied for details regarding mounting, electrical clearances, and linkage setups. P&A should be consuled whenever additional in formation is required. Thermal application of the circuit breaker to the transformer is done in accordance with the principles outlined in ANSI/IEEE Standard #C57.91-1981, Guide for Loading Mineral-Oil-Immersed Overhead and Pad-Mounted Distribution Transformer. Where: To = Temperature of the oil in the vicinity of the bimetal in When Tb reaches the trip temperature setting of the breaker (TB), the breaker trips. The J constants for the various bimetal are given in Table 2. Short time performances of the circuit breakers are described by various curve sets listed in Table 2.

The following tables present the suggested P&A CSP breaker selection for proper coordination in self-protected transformers. Table 1 : Circuit Breaker Rating & Application Data Parameter LR Breaker SQR Breaker LQR Breaker HQR Breaker Bimetal ID 042 063 104 156 208 313 417 577 722 909 minal Current Rating 45A 65A 110A 160A 210A 350A 450A 620A 780A 970A Interrupting Current Rating : 2 shots (rms symmetrical) 6,000A 12,000A 25,000A 30,000A Volts per Pole 240V 240V 240V 240V Power Frequency Withstand Voltage 10KV 10KV 10KV 10KV Impulse Voltage Withstand 30KV 30KV 30KV 30KV Minimum Trip Temperature 100 100 100 100 Maximum Trip Temperature 160 160 160 160 Trip Temperature Increment 10 10 10 10 Tolerance on Trip Temperature(Trip & sig) Signal Circuit Trip Temperature(minal) (degrees less than breaker trip temperature) Emergency Control Trip Temperature(minal) (degrees greater than breaker trip temperature) ±10% ±10% ±10% ±10% 15 25 30 30 30 30 15 15 15 25 25 25 Table 2 : Breaker Application Constants Breaker Type Bimetal ID J Shot Time Curve LR 042 0.00200 #735702-A LR 063 0.00120 #735702-A LR 104 0.00070 #735702-A SQR 156 0.00020 #735702-A SQR 208 0.00014 #735702-A LQR 313 0.00009 #735702-A LQR 417 0.00007 #735702-A HQR 577 0.000045 #735702-B HQR 722 0.000033 #735702-B HQR 909 0.000023 #735702-B

Table 3 : Ordering Information for Frame Mounted Breaker 3-Phase Breaker in Standard Configuration Trip Bimetal ID Transformer kva 420V 400V Signal Circuit Emergency Handle Orientation Style Number 3LAi04MAxx 3LAi04MBxx Thermal 042 30 30 3LAi04RAxx 3LAi04RBxx 3LAi04EAxx 3LAi04EBxx 3LAi06MAxx 3LAi06MBxx Thermal 063 45 45 3LAi06RAxx 3LAi06RBxx 3LAi06EAxx 3LAi06EBxx 3QAi10MAxx 3QAi10MBxx Thermal 104 75 75 3QAi10RAxx 3QAi10RBxx 3QAi10EAxx 3QAi10EBxx 3QAi16MAxx 3QAi16MBxx Thermal/Magnetic 156 112.5 100 3QAi16RAxx 3QAi16RBxx 3QAi16EAxx 3QAi16EBxx 3QAi21MAxx 3QAi21MBxx Thermal/Magnetic 208 150 150 3QAi21RAxx 3QAi21RBxx 3QAi21EAxx 3QAi21EBxx 1. te : When ordering, substitute the breaker trip temperature minus 100 for the values of "xx" in the above table (i.e. 3LAi10MA50 has a trip temperature of 150 ) 2. Frame mounted LR, SQR, LQR and HQR breaker may be ordered in accordance with table 3, above. For special designs, not covered by the standard styles, please refer to P&A.

Table 3 : Ordering Information for Frame Mounted Breaker 3-Phase Breaker in Standard Configuration Trip Bimetal ID Transformer kva 420V 400V Signal Circuit Emergency Handle Orientation Style Number 3QAi31MAxx 3QAi31MBxx Thermal/Magnetic 313 225 200 3QAi31RAxx 3QAi31RBxx 3QAi31EAxx 3QAi31EBxx 3QAi42MAxx 3QAi42MBxx Thermal/Magnetic 417 300 300 3QAi42RAxx 3QAi42RBxx 3QAi42EAxx 3QAi42EBxx 3QAi58MAxx 3QAi58MBxx Thermal/Magnetic 577 450 400 3QAi58RAxx 3QAi58RBxx 3QAi58EAxx 3QAi58EBxx 3QAi72MAxx 3QAi72MBxx Thermal/Magnetic 722 500 500 3QAi72RAxx 3QAi72RBxx 3QAi72EAxx 3QAi72EBxx 3QAi91MAxx 3QAi91MBxx Thermal/Magnetic 909 630 630 3QAi91RAxx 3QAi91RBxx 3QAi91EAxx 3QAi91EBxx 1. te : When ordering, substitute the breaker trip temperature minus 100 for the values of "xx" in the above table (i.e. 3LAi10MA50 has a trip temperature of 150 ) 2. Frame mounted LR, SQR, LQR and HQR breaker may be ordered in accordance with table 3, above. For special designs, not covered by the standard styles, please refer to P&A.

Table 4 : Ordering Information for Wall Mounted Breaker 3-Phase Breaker in Standard Configuration Trip Bimetal ID Transformer kva 420V 400V Thermal 042 30 30 Thermal 063 45 45 Thermal 104 75 75 Thermal/Magnetic 104 75 75 Thermal/Magnetic 156 112.5 100 Thermal/Magnetic 208 150 150 Thermal/Magnetic 313 225 200 Thermal/Magnetic 417 300 300 Thermal/Magnetic 577 450 400 Thermal/Magnetic 722 500 500 Thermal/Magnetic 909 630 630 Signal Circuit Emergency Handle Orientation Style Number Standard 3LAi04MDxx Standard 3LAi04RDxx Standard 3LAi04EDxx Standard 3LAi06MDxx Standard 3LAi06RDxx Standard 3LAi06EDxx Standard 3LAi10MDxx Standard 3LAi10RDxx Standard 3LAi10EDxx Standard 3QAi10MDxx Standard 3QAi10RDxx Standard 3QAi10EDxx Standard 3QAi10MDxx Standard 3QAi16RDxx Standard 3QAi16EDxx Standard 3QAi21MDxx Standard 3QAi21RDxx Standard 3QAi21EDxx Standard 3QAi31MDxx Standard 3QAi31RDxx Standard 3QAi31EDxx Standard 3QAi42MDxx Standard 3QAi42RDxx Standard 3QAi42EDxx Standard 3QAi58MDxx Standard 3QAi58RDxx Standard 3QAi58EDxx Standard 3QAi72MDxx Standard 3QAi72RDxx Standard 3QAi72EDxx Standard 3QAi91MDxx Standard 3QAi91RDxx Standard 3QAi91EDxx 1. te : When ordering, substitute the breaker trip temperature minus 100 for the values of "xx" in the above table (i.e. 3LAi10MD50 has a trip temperature of 150 ) 2. Wall Mounted breakers may be ordered in accordance with Table 4, above. For special designs, not covered by the standard style, please refer to P&A.