Eaton Contamination Control Products FT1455-L3 Hand held launcher operating instructions

Similar documents
FT1455-L3 Hand Launcher Operating Instructions

Eaton Contamination Control Products FT1455-L2 Hand Held Launcher Operating Instructions

FT1455-L2 Hand Launcher Operating Instructions

Eaton Contamination Control Products FT1455-L4 Bench mount launcher operating instructions

Eaton Contamination Control Products

MG7000 Operating Instructions & Parts Manual

XCEL80 Steering Control Units

Eaton Hydraulic Motor. Repair Information. 30 Series. July, 1996

Weatherhead ET4020 & ET4040 Crimp Machines. New Crimp Machines Now Available!

Char-Lynn Steering Control Unit. Repair Information

Eaton Hydraulic Motor. Repair Information. 45 Series. July, 1996

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions

Char-Lynn Power Steering. Parts Information. 217 Series and 227 Series OUT OUT. November, Series (Gerotor Unit) 227 Series (Geroler Unit)

A better solution for your toughest light-duty motor challenges.

Superior performance and reliability. Eaton Xcel Series Low-Speed High-Torque Motors

UC-AL AutoLoader System

Eaton Weatherhead ET4001 Crimp Machine Operator's Manual

Mobile Valves Proportional - Load Sensing

Char-Lynn Power Steering. Parts Information. 110, 230, and 450 Series. July, 1999

MDG Mobile Directional Valve Build Kit. MDG for Mobile Equipment Flows to 60 I/min (15.8 US gpm)

Eaton EC inch 6-spiral hose

Eaton Hydraulic Motor. Repair Information. Series VIS 45. January, 2000

Eaton ET5050 Crimp Machine

Eaton Inline Self-Level Valve

How to Identify Fluid Ports and Connectors

Eaton LifeSense Wired System Quick Setup Guide

Pressure Gauge Kit and Test Couplings

Char-Lynn T-Series General Purpose Geroler Motor

Char-Lynn Hydraulic Motor. Parts Information. R Series General Purpose Geroler Motor January, 1995

ET1187 Crimp Machine. Operator s Manual. Portable Variable Crimp Machine

Eaton Hydraulic Motor. Repair Information. VIS 45 Series Two Speed Bearingless -001

220 Piston pump Service manual AEC 028

Char-Lynn Hydraulic Motor. Repair Information Series. April, 1997

Series 1 shaft seal installation instructions

VIS Standard and Wheel Motors 45 Series Parts and Repair Information -005

Keep it Running. Proportional Valve Service and Repair Program North America. Vickers Proportional Valves Factory Service Program

Fixed Displacement Swing Drive Motor. JMF Axial Piston Motor Peak Pressure: 385 bar Displacement 29~250 cc/r

620 Mobile open circuit Piston pump service manual ADY074 ADY098

Eaton ET3000 Portable Crimper

Eaton Oil & Gas. Count on reliable power to protect your people and the environment

Eaton Hydrostatic Transaxle. Parts Information. Transaxle Series 751. May, 1999

Please carefully follow ALL safety procedures and recommendations contained in this handbook.

Sepehr Hydraulic Asia

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Char-Lynn HP 30 Motor

Eaton Heavy Duty Hydrostatic Transmissions

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

CMA200 Advanced Subject Independent-Metering title Mobile Valve. 200LPM 440 bar CAN Bus

MACHINES AND ACCESSORIES - hose assembly production

Eaton Gromelle Flat Face Quick Disconnect Couplings

Eaton FLOCS TM Fast Lube Oil Change System Catalog

Solenoid Operated Directional Valve

STAUFF. Local Solutions for Individual Customers Worldwide. Stauff Tube Clean System. Pipe, Tube & Hose Cleaning System

High Pressure, High Performance Double Vane Pumps Parts Data VMQ24525S Series 32 Design

High Pressure, High Performance Double Vane Pumps Parts Data VMQ24535S Series 32 Design

Standard Package Systems Product Focus. Now, More Choices In Vickers Power Unit Offerings. Whatever the Industry. Whatever the Application.

Ultronics ZTS16 Twin Spool Valve

Solutions. ydraulics. Manufacture. H y d r a u l i c s. Eaton Hydrostatic Transaxles. h y d r a u l i c s

CMA90 Advanced Independent-Metering Mobile Valve

RH160E. Rivet Nut setting Tool (Spin /Pull) Instructions & Parts List

Global Gear Products. Brochure. SAE A-Aluminum (Group 2)

VIS 40 Series Brake Motors Parts and Repair Manual -004

VALV-POWR VALUE-LINE DOUBLE-OPPOSED PISTON ACTUATORS MODEL A. Installation, Maintenance and Operating Instructions

How to Identify Fluid Ports and Connectors

Automatic Lubrication

3500 PSI Fixed Displacement Mobile Vane Pumps VQH Series (Supplement to Catalog 353)

420 Mobile piston pump Service manual

Vickers. Service Data. Vane Pumps. Thru Drive Vane Type Pump (F3) 25VT*(M) **A(M)2 ** * 22 * I-3154-S. Rev. 2/98

QRV 9100 Airflex Quick release valve Installation, operation and maintenance of Airflex Quick release valve

100R5. Features 100R5-style crimp fittings from Eaton complement the company s industryrecognized, reusable fitting line.

Aeroquip ProCrimp 1370 Crimp Machine Operator s Manual

Field-Mate Series Agricultural Cylinders. ASAE Interchangeable HYDRO-LINE

Eaton Hydrostatic Variable Motors. Repair Information

INTERNAL PIPE CLEANING TOOL

Eaton Medium Duty Piston Pump. Repair Information. Model Variable Displacement Piston Pump

Eaton Medium Duty Piston Pump. Repair Information. Model Variable Displacement Piston Pump

Horizontal, Angle, & Vertical Grinders

SB20G. Large Pressurized Abrasive Blaster Assembly & Operating Instructions

s Eaton Light Duty Hydrostatic h y Hydrostatic Transmissions Models 6, 7, and 11 Ball Piston Pumps Models 7 and 11 We Manufacture Solutions

SINGLE ACTING METRIC RANGE

Bulk Liquid Filtration

GBP784B INSTALLATION TOOL

Aeroquip BRUISER FC735 FC736 FC839B FC273B FC849B FC606B. Abrasion-Resistant Polymer-Covered Hose

Vickers. Service Data. Vane Pumps. High Pressure, High Performance Double Vane Pump. 4525VPF Series -21 Design /EN/0396/S

INSTRUCTION AND MAINTENANCE MANUAL GFH45 PRESSURE REGULATOR

LIQUID MEDIA BLASTER INSTRUCTIONS

DOUBLE ACTING METRIC RANGE

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

Eaton ET4020 & ET4040 Crimp Machines

Vickers. Overhaul Manual. Transmissions. Adjustable Speed Hydraulic Drives. TR3, PTR3 and MTR3 Series -20 Design

type 122a three-way Switching Valve

Eclipser 2500/2800 OPERATING MANUAL. and Continuous Coil (CC) Clipping System. ENCORE (EA) ECLIPSER 2500 and 2800 SERIES

Tidland Internal Element Shaft

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

AIR DRIVEN TUBE CLEANER

Alligator Staple Gold Class Plus

Industrial Welded Cylinders

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

AIR PAINT SHAKER OWNER'S MANUAL

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

Transcription:

Eaton Contamination Control Products FT1455-L3 Hand held launcher operating instructions

Table of Content General information 3 Safety instructions 3 installation 3 Maintenance 3 Preparation 3 Operation 5 Nozzle and selection chart 6 Tube sizing chart - nominal inch 7 Recommended sizing chart - metric tubing 8 Pipe sizing chart 9 Contact Information 10 Nozzle Trigger Pneumatic Connection Figure 1 Capabilities Cleaning size range: 1/8 through 3-1/4. (Can clean hoses larger than 3-1/4 upto 4-1/2 with optional 4-1/2 nozzle) Specifications Weight: 3.3 pounds. (1.496kg). Pneumatic requirements: 1/2 NPT air line. 80 PSI - 110 PSI. (5.5-7.5 Bar) maximum. Clean, dry, filtered air or inert gas source is required. 5 micron filter and regulator with gauge are recommended. 2 EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E November 2015

General Information The Eaton FT1455-L3 Hand Held Launcher was designed to shoot a through hose and tube assemblies to strip out internal contamination such as rubber dust and metal particles from cutting processes, metal flash from crimping operations, and contaminated oil from hoses and tubes in hydraulic systems. Eaton Hose Cleaning Systems reduce downtime, extends filter life and reduces the risk of failure and premature wear due to contamination. The purpose of this manual is to present the basic operating and safety information for the Eaton FT1455-L3 Hand Held Projectile Launcher. Preparation Step 1: Nozzle and selection Select nozzle and from nozzle and selection charts on pages 6, 7, 8 and 9. Step 2: Nozzle installation Remove the locking ring from the firing head by rotating ring clockwise. (See Figure 2 & 3) Safety Instructions Read and understand the operator s manual before attempting to operate this unit. Failure to follow operating instructions could result in personal injury or property damage. Prevent Unauthorized Operation: Do not permit anyone to operate this unit unless they have read and thoroughly understand this manual. Wear Safety Glasses: Risk of eye injury! Eye protection is required at all times during the installation and operation of this unit. Failure to wear safety glasses could result in personal injury. Figure 2 Keep work area clean. Cluttered areas and benches invite accidents. Never point or fire the unit in the direction of any person. Do not attempt to dislodge a from the Hand Held Launcher when air supply is connected to the launcher. Do not place any objects into the launching nozzle other than Eaton Projectiles. Figure 3 Launcher and s are only to be used for cleaning hose and tubes rated for at least 110 PSI. Installation When installing the hand held launcher make sure you have a filtered and regulated air or inert gas source. Note: Never Use Oxygen. A 1/2 NPT regulator with gauge and a 5 micron air filter should be installed in the supply line to ensure clean dry air. Maintenance Visually inspect Hand Launcher for accumulation of particulate and oil from inlet air source. Clean as needed. Keep the hose assembly area clean to reduce recontamination of hose, tube and pipe assemblies. EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E November 2015 3

Step 3: Projectile Installation Install the required nozzle and adapter ring for application. The adapter ring if needed, snaps into the face plate first. (See Figure 4) Insert into the nozzle, and reattach locking ring to the firinghead by rotating ring counterclockwise. (See Figure 5 & 6) Note: Failure to secure locking ring may cause serious injury to the operator and or damage to the launcher. Figure 4 Figure 6 Step 4: Nozzle installation Connect a 1/2 I.D. air hose using the supplied full flow Quick Connect Coupling to the back of the launchers 5 micron air filter as shown. (See Figure 7). Figure 5 Figure 7 4 EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E November 2015

Step 5: Operation Place the hose, tube or pipe against the nozzle to insure a good air seal. Depress the trigger until the exits the opposite end of the hose, tube or pipe you are cleaning. (See Figure 8). Step 6: Inspection Inspect for contamination after firing through hose, tubing or pipe. Several s may need to be fired to thoroughly remove contaminates. (See Figure 9). Figure 8 Figure 9 EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E November 2015 5

Nozzle and selection chart Recommnedation for Hoses Nominal diameter Inches mm Nozzle Cleaning 3/16 05 FT1455-N-H06 FT1355-H-06 ¼ 06 FT1455-N-H06 FT1355-H-10 or FT1355-H-12 5/16 08 FT1455-N-H08 FT1355-H-12 or FT1355-H-14 3/8 10 FT1455-N-H10 FT1355-H-14 or FT1355-H-16 ½ 13 FT1455-N-H13 FT1355-H-18 or FT1355-H-20 5/8 16 FT1455-N-H16 FT1355-H-22 ¾ 19 FT1455-N-H19 FT1355-H-26 1 25 FT1455-N-H25 FT1355-H-33 or FT1355-H-36 1-1/4 32 FT1455-N-H32 FT1355-H-40 or FT1355-H-45 1-1/2 38 FT1455-N-H38 FT1355-H-50 or FT1355-H-55 2 50 FT1455-N-H50 FT1355-H-60 or FT1355-H-65 2-1/2 63 FT1455-N-U55 FT1355-H-75 3 76 FT1455-N-U55 FT1355-H-85 3-1/2 89 FT1455-N-U55 FT1355-H-100 4 102 FT1455-N-45 4-1/2 114 FT1455-N-45 Recommendations for hose assemblies with ORS fittings ORS fitting dash size Nozzle Cleaning -4 FT1455-4FFORX FT1355-H-06 OR FT1355-H-07-6 FT1455-N-H06 FT1355-H-12-8 FT1455-N-H10 FT1355-H-16-10 FT1455-N-H13 FT1355-H-22-12 FT1455-N-H16 FT1355-H-26-16 FT1455-N-H19 FT1355-H-33-20 FT1455-N-H25 FT1355-H-40 Figure 12 Figure 10 Recommendations for hose assemblies with code 61 or 62 flanges Code 61 or 62 flange dash size Nozzle -8 FT1455-N-H10 FT1355-H-16-10 FT1455-N-H13 FT1355-H-22-12 FT1455-N-H16 FT1355-H-26-16 FT1455-N-H19 FT1355-H-33-20 FT1455-N-H25 FT1355-H-40-24 FT1455-N-H32 FT1355-H-50-32 FT1455-N-H38 FT1355-H-60 Figure 11 Cleaning **Use larger recommended Eaton Projectiles when cutting hose with an abrasive wheel. The above sizes are recommendations. Due to different types of fittings, and the amount ofcontamination in the line, the size may need to be adjusted. Recommendations for s for hose assemblies with JIC Fittings JIC fitting dash size Nozzle Cleaning -4 FT1455-J-06 FT1355-H-06 OR FT1355-H-07-6 FT1455-J-10 FT1355-H-12-8 FT1455-J-13 FT1355-H-16-10 FT1455-J-16 FT1355-H-22-12 FT1455-J-19 FT1355-H-26-16 FT1455-J-25 FT1355-H-33-20 FT1455-J-32 FT1355-H40-24 FT1455-J-38 FT1355-H-50-32 FT1455-J-50 FT1355-H-60 Figure 13 6 EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E November 2015

Tube sizing chart - nominal inch Recommended nozzles and cleaning s for tubes (inch) Outside diameter x wall thickness Figure 14 Nozzle Cleaning Tubing must be deburred prior to firing s. Depending on the type of contamination present in the tube, abrasive s may be used to remove rust and scale. Always use an Eaton after the use of an abrasive. Tube s should be used to remove mandrel lubricants, grease and oil. Abrasive Tube 1/8" X.030" FT1455-NT-03 - - - ¼" X.035" FT1455-NT-06 FT1355-H-10 FT1355-A-07 FT1355-T-06 ¼" X.049" FT1455-NT-06 FT1355-H-08 FT1355-A-07 FT1355-T-06 ¼" X.065" FT1455-NT-06 FT1355-H-07 - FT1355-T-06 5/16" X.035" FT1455-NT-08 FT1355-H-12 FT1355-A-10 FT1355-T-07 3/8" X.035"-.049" FT1455-NT-10 FT1355-H-14 FT1355-A-12 FT1355-T-10 3/8" X.065" FT1455-NT-10 FT1355-H-12 FT1355-A-10 FT1355-T-10 ½" X.035" FT1455-J-13 FT1355-H-16 FT1355-A-16 FT1355-T-14 ½" X.049" FT1455-J-13 FT1355-H-16 FT1355-A-16 FT1355-T-12 ½" X.065" FT1455-J-13 FT1355-H-16 FT1355-A-14 FT1355-T-12 ½" X.083" FT1455-J-13 FT1355-H-14 FT1355-A-12 FT1355-T-12 5/8" X.049" FT1455-J-16 FT1355-H-22 FT1355-A-20 FT1355-T-16 5/8" X.065" FT1455-J-16 FT1355-H-20 FT1355-A-18 FT1355-T-16 5/8" X.083" FT1455-J-16 FT1355-H-20 FT1355-A-18 FT1355-T-14 ¾" X.049"-.065" FT1455-J-19 FT1355-H-26 FT1355-A-24 FT1355-T-20 ¾" X.095" FT1455-J-19 FT1355-H-22 FT1355-A-20 FT1355-T-18 7/8" X.049" FT1455-J-25 FT1355-H-33 FT1355-A-30 FT1355-T-26 7/8" X.065" FT1455-J-25 FT1355-H-30 FT1355-A-28 FT1355-T-22 7/8" X.095" FT1455-N-H16 FT1355-H-28 FT1355-A-26 FT1355-T-22 1" X.065" FT1455-J-32 FT1355-H-33 FT1355-A-30 FT1355-T-28 1" X.083"-.095" FT1455-J-32 FT1355-H-33 FT1355-A-30 FT1355-T-26 1" X.120" FT1455-J-32 FT1355-H-30 FT1355-A-28 FT1355-T-26 1-1/4" X.065" FT1455-NT-32 FT1355-H-40 FT1355-A-40 FT1355-T-33 1-1/4" X.083" FT1455-NT-32 FT1355-H-40 FT1355-A-36 FT1355-T-33 1-1/4" X.095" FT1455-NT-32 FT1355-H-40 FT1355-A-36 FT1355-T-33 1-1/4" X.109" FT1455-NT-32 FT1355-H-36 FT1355-A-36 FT1355-T-33 1-1/4" X.120" FT1455-NT-32 FT1355-H-36 FT1355-A-33 FT1355-T-33 1-1/2" X.065"-.120" FT1455-J-38 FT1355-H-50 FT1355-A-45 FT1355-T-40 1-1/2" X.134"-.148" FT1455-J-38 FT1355-H-45 FT1355-A-40 FT1355-T-40 2" X.065"-.120" FT1455-J-50 FT1355-H-60 FT1355-A-55 FT1355-T-50 2" X.134"-.188" FT1455-J-50 FT1355-H-55 FT1355-A-50 FT1355-T-50 1-1/2" X.134"-.148" FT1455-J-38 FT1355-H-45 FT1355-A-40 FT1355-T-40 2" X.065"-.120" FT1455-J-50 FT1355-H-60 FT1355-A-55 FT1355-T-50 2" X.134"-.188" FT1455-J-50 FT1355-H-55 FT1355-A-50 FT1355-T-50 EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E November 2015 7

Recommended sizing chart - metric tubing Outside diameter x Wall thickness Nozzle Cleaning Abrasive Tube 6 X 1.0 FT1455-NT-06x1.5 FT1355-H-07 FT1355-A-06 FT1355-T-06 6 X 1.5 FT1455-NT-06x1.5 FT1355-H-07 FT1355-A-06 #N/A 8 X 1.0 FT1455-NT-08x1.5 FT1355-H-10 FT1355-A-07 FT1355-T-07 8 X 1.5 FT1455-NT-08x1.5 FT1355-H-10 FT1355-A-07 FT1355-T-07 10 X 1.0 FT1455-NT-10x1.5 FT1355-H-14 FT1355-A-12 FT1355-T-12 10 X 1.5 FT1455-NT-10x1.5 FT1355-H-14 FT1355-A-12 FT1355-T-12 12 X 1.0 FT1455-NT-12x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 12 X 1.5 FT1455-NT-12x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 12 X 2.0 FT1455-NT-12x2.0 FT1355-H-14 FT1355-A-12 FT1355-T-12 14 X 1.0 FT1455-NT-14x2.0 FT1355-H-18 FT1355-A-16 FT1355-T-16 14 X 1.5 FT1455-NT-14x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 14 X 2.0 FT1455-NT-14x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 15 X 1.0 FT1455-NT-15x2.0 FT1355-H-20 FT1355-A-18 FT1355-T-16 15 X 1.5 FT1455-NT-15x2.0 FT1355-H-18 FT1355-A-16 FT1355-T-16 15 X 2.0 FT1455-NT-15x2.0 FT1355-H-16 FT1355-A-14 FT1355-T-14 16 X 1.0 FT1455-NT-16x2.5 FT1355-H-22 FT1355-A-20 FT1355-T-18 16 X 1.5 FT1455-NT-16x2.5 FT1355-H-20 FT1355-A-18 FT1355-T-16 16 X 2.0 FT1455-NT-16x2.5 FT1355-H-18 FT1355-A-16 FT1355-T-16 16 X 2.5 FT1455-NT-16x2.5 FT1355-H-16 FT1355-A-14 FT1355-T-14 18 X 1.0 FT1455-NT-18x2.5 FT1355-H-24 FT1355-A-22 FT1355-T-20 18 X 1.5 FT1455-NT-18x2.5 FT1355-H-24 FT1355-A-20 FT1355-T-18 18 X 2.0 FT1455-NT-18x2.5 FT1355-H-22 FT1355-A-20 FT1355-T-18 18 X 2.5 FT1455-NT-18x2.5 FT1355-H-20 FT1355-A-18 FT1355-T-16 20 X 1.5 FT1455-NT-20x3.0 FT1355-H-26 FT1355-A-24 FT1355-T-22 20 X 2.0 FT1455-NT-20x3.0 FT1355-H-24 FT1355-A-22 FT1355-T-20 20 X2.5 FT1455-NT-20x3.0 FT1355-H-24 FT1355-A-20 FT1355-T-18 Outside diameter x Wall thickness Nozzle Cleaning Abrasive Tube 20 X3 FT1455-NT-20x3.0 FT1355-H-22 FT1355-A-20 FT1355-T-18 22 X1 FT1455-NT-22x2.0 FT1355-H-30 FT1355-A-28 FT1355-T-26 22 X1.5 FT1455-NT-22x2.0 FT1355-H-30 FT1355-A-28 FT1355-T-26 22 X2 FT1455-NT-22x2.0 FT1355-H-30 FT1355-A-28 FT1355-T-26 25 X2 FT1455-NT-25x3.0 FT1355-H-33 FT1355-A-30 FT1355-T-28 25 X2.5 FT1455-NT-25x3.0 FT1355-H-30 FT1355-A-28 FT1355-T-26 25 X3 FT1455-NT-25x3.0 FT1355-H-30 FT1355-A-28 FT1355-T-26 28 X2 FT1455-NT-28x2.5 FT1355-H-36 FT1355-A-33 FT1355-T-33 28 X2.5 FT1455-NT-28x2.5 FT1355-H-36 FT1355-A-33 FT1355-T-30 30 X2 FT1455-NT-30x4.0 FT1355-H-36 FT1355-A-33 FT1355-T-33 30 X2.5 FT1455-NT-30x4.0 FT1355-H-36 FT1355-A-33 FT1355-T-30 30 X3 FT1455-NT-30x4.0 FT1355-H-36 FT1355-A-33 FT1355-T-30 30 X4 FT1455-NT-30x4.0 FT1355-H-36 FT1355-A-33 FT1355-T-30 35 X2 FT1455-NT-35x3.0 FT1355-H-45 FT1355-A-40 FT1355-T-40 35 X3 FT1455-NT-35x3.0 FT1355-H-40 FT1355-A-36 FT1355-T-36 35 X4 FT1455-N-H25 FT1355-H-40 FT1355-A-36 FT1355-T-33 35 X5 FT1455-N-H25 FT1355-H-36 FT1355-A-33 FT1355-T-30 38 X2.5 FT1455-NT-38x5.0 FT1355-H-50 FT1355-A-45 FT1355-T-40 38 X3 FT1455-NT-38x5.0 FT1355-H-50 FT1355-A-45 FT1355-T-40 38 X4 FT1455-NT-38x5.0 FT1355-H-45 FT1355-A-40 FT1355-T-40 38 X5 FT1455-NT-38x5.0 FT1355-H-40 FT1355-A-36 FT1355-T-36 42 X2 FT1455-NT-42x3.0 FT1355-H-55 FT1355-A-50 FT1355-T-50 42 X3 FT1455-NT-42x3.0 FT1355-H-50 FT1355-A-50 FT1355-T-45 50 X3 FT1455-NT-50x5.0 FT1355-H-60 FT1355-A-55 FT1355-T-55 50 X5 FT1455-NT-50x5.0 FT1355-H-55 FT1355-A-55 FT1355-T-50 50 X6 FT1455-NT-50x5.0 FT1355-H-55 FT1355-A-50 FT1355-T-50 Figure 15 Tubing must be deburred prior to firing s. Depending on the type of contamination present in the tube, abrasive s may be used to remove rust and scale. Always use an Eaton after the use of an abrasive. 8 EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E November 2015

Pipe sizing chart Recommended nozzles and cleaning s for pipes (inch) SCH 40 Nozzle Cleaning Abrasive 1/4" FT1455-N-H08 FT1355-H-14 FT1355-A-12 3/8" FT1455-N-H13 FT1355-H-18 FT1355-A-16 1/2" FT1455-N-H16 FT1355-H-20 FT1355-A-18 3/4" FT1455-N-H19 FT1355-H-30 FT1355-A-26 1" FT1455-N-H25 FT1355-H-36 FT1355-A-33 1-1/4" FT1455-N-H32 FT1355-H-45 FT1355-A-40 1-1/2" FT1455-N-H38 FT1355-H-55 FT1355-A-50 2" FT1455-N-H50 FT1355-H-65-2-1/2" FT1455-N-U55 FT1355-H-75-3" FT1455-N-U55 FT1355-H-85-3-1/2" FT1455-N-U55 FT1355-H-100 - SCH 80 Nozzle Cleaning Abrasive 1/4" FT1455-N-H06 FT1355-H-12 FT1355-A-10 3/8" FT1455-N-H10 FT1355-H-16 FT1355-A-14 1/2" FT1455-N-H13 FT1355-H-20 FT1355-A-16 or FT1355-A-18 3/4" FT1455-N-H19 FT1355-H-26 FT1355-A-22 1" FT1455-N-H25 FT1355-H-36 FT1355-A-30 1-1/4" FT1455-N-H32 FT1355-H-45 FT1355-A-40 1-1/2" FT1455-N-H38 FT1355-H-50 FT1355-A-45 2" FT1455-N-H38 FT1355-H-60 FT1355-A-55 2-1/2" FT1455-N-H50 FT1355-H-70-3" FT1455-N-U55 FT1355-H-85-3-1/2" FT1455-N-U55/90 FT1355-H-110 FT1355-A-110 4" FT1455-N-4.5LN FT1355-H-115 FT1355-A-110 SCH 160 Nozzle Cleaning Abrasive 1/2" FT1455-N-H10 FT1355-H-16 FT1355-A-14 3/4" FT1455-N-H16 FT1355-H-20 FT1355-A-18 1" FT1455-N-H19 FT1355-H-30 FT1355-A-26 1-1/4" FT1455-N-H25 FT1355-H-36 FT1355-A-33 1-1/2" FT1455-N-H32 FT1355-H-45 FT1355-A-40 2" FT1455-N-H38 FT1355-H-55 FT1355-A-45 or FT1355-A-50 2-1/2" FT1455-N-H50 FT1355-H-65 FT1355-A-60 3" FT1455-N-U55 FT1355-H-75 4" FT1455-N-U55 FT1355-H-100 Figure 16 Abrasive s may be used when there is a build-up of contamination, surface rust or scale. For pipe applications where there is a greater build-up of contamination, surface rust or scale, use a grinding. Pipe must be straight for this. NOTE: To ensure cleanliness, an Eaton must be used after abrasive. Please call if you need help in sizing your application for the correct nozzles and s. EATON FT1455-L3 Hand Launcher Operating Instructions E-HOAI-CC003-E November 2015 9

Eaton Hydraulics Business USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Hydraulics Business Europe Route de la Longeraie 7 1110 Morges Switzerland Tel: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Hydraulics Group Asia Pacific Eaton Building No.7 Lane 280 Linhong Road Changning District, Shanghai 200335 China Tel: (+86 21) 5200 0099 Fax: (+86 21) 2230 7240 2015 Eaton All Rights Reserved Printed in USA Document No. E-HOAI-CC003-E November 2015 Assembly Equipment Technical Support Service Spare Parts www.eatoncrimpersupport.com (1-888-285-6627) (517-563-8800)