Appendix. Clearance. Skewed profiles. Application Schematics

Similar documents
From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Insertion Flow Meters. Municipal Market Customer Presentation

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

ISTEC MAGNETIC METERS

Full Profile Insertion

Rosemount 8750WB Magnetic Flowmeter System

Low Profile Insertion Vortex

Hot Tap Insertion Vortex

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Electromagnetic Flowmeters. Product Overview.

Model Q45H/ Residual Chlorine Monitor...

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

2100 Turbine Flow Sensor

VORTEX IN-LINE FLOW METERS

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Marsh McBirney Flo-Dar

PMG MAGNETIC FLOWMETER

F-2700 SERIES INSERTION VORTEX FLOW METER

SIGNET 7002 Vortex Flow Sensor ENGLISH

Vortex In Line Flow Meter

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Model 1000 Vortex Meter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Vortex In Line Flow Meter

Operating Manual Model- P282 Digiflow Controller

Signet Temperature Transmitter

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Model FVP General Specification. Flanged Vortex Plate. Product Features

F-2700 SERIES INSERTION VORTEX FLOW METER

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Vortex Plate. Model VP General Specification. Product Features

Time Delta S Fixed Transit-Time Flow Meter System

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Signet Pressure Transmitter

RCM - Direct Reading Flowmeters

Ultra Mag SUBMITTAL PACKAGE

UTM10 Series Ultrasonic Transit-time Flowmeters

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

F-1500 SERIES INSERTION TURBINE FLOW METER

Signet Pressure Transmitter

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

SIGNET Temperature Transmitter

Warnings and Cautions. Precision Flow Insertion Mass Flow Meter. Instruction Manual BULLETIN F-41-PFS FR# R

Model 5000 Vortex Meter

Signet 2551 Magmeter Flow Sensor

Field IT Electro-Magnetic Flowmeters Sensors

Octave Water Meter Installation Manual

Electromagnetic Flow Monitor magphant

Paddle-wheel flow controller for On/Off control

Range of Ultrasonic Flowmeters.

F-2600 SERIES INLINE VORTEX FLOW METER

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

SeaMetrics Flow Meters and Flow Computers

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Dissolved Oxygen Measurement System with Air Blast Cleaner

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

F-2500 SERIES VORTEX METER

Electromagnetic flowmeter. Descriptions. Specifications

LTX RF LEVEL SENSOR. Instruction Manual

Electromagnetic flowmeter EMKO E

mass flowmeter for compressed air

Model 282L Single Point Insertion Electromagnetic Flow Meter 1 and 2 Sensors

Armstrong In-Line and Insertion Vortex Flow Meters

Hydro-Flow Model 3100


EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

Paddle-wheel flow controller for On/Off control

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

INSERTION flowmeter with paddle wheel, ELEMENT design

Vortex Eggs Delta Flowmeter

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

M SERIES Multi-Jet Cold Water Meter

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Quick Start Guide. Tek-Flux 1400A. 796 Tek Drive, Crystal Lake, IL USA

Hydro-Flow Model 2300 Installation and Operation Guide B

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

MagFlux Q 8200 Series

Magnetic-inductive flow meter for hazardous areas

유량계전문제조업체. Electro Magnetic FLOWMETER

NC State University Design and Construction Guidelines Division 23 Energy Management

Instruction manual. Smart Thermal Mass Flow Meter. TYPE : 3000S Series. ientek Co., Ltd.

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

VLM20 In-line Vortex Flowmeter

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

imag 4700 SERIES FLANGED MAGMETER

BI-DIRECTIONAL INSERTION METER

Transcription:

Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will protrude from the pipe when installed, a clearance length should be allowed. See Obstruction Diagram below and Sensor Specification Sheet on page 50. Skewed profiles The sensor may not operate within specifications in a location where the profile is skewed These locations are indicated by an ESTIMATED ERROR notation in the application schematics. Errors are estimated for flow at +/-10 ft/sec (±3 m/sec). If the velocity is less than ±10 ft/sec, the error will be less. To avoid velocity "hot" or "cold" spots, choose an insertion angle that is away from the hot spot. Distance H must be at least the total sensor length plus the distance from the outer pipe wall to the top of the valve plus 9 (distance H). See sensor specification sheet. H NO YES Velocity Hot Spot OBSTRUCTION Installation and Operation: Multi-Mag Model 285 43

Appendix, Application Schematics OPERATION WITHIN SPECIFIED ACCURACIES GREATER THAN 5 PIPE DIAMETERS ESTIMATED ERROR 1% TO 4% 2-5 PIPE DIAMETERS ESTIMATED ERROR 4% TO 10% 2 PIPE DIAMETERS The best locations are greater than 5 diameters upstream or 10 diameters downstream from the elbow. 90º Elbow (errors are estimated for flow at 10 ft/sec) (3 m/sec) 44 Marsh-McBirney, Inc.

Appendix, Application Schematics ESTIMATED ERROR 1% TO 4% ESTIMATED ERROR 4% TO 10% ESTIMATED ERROR 10% TO 4% ESTIMATED ERROR 4% TO 1% 2-5 PIPE DIAMETERS 2 PIPE DIAMETERS 2 PIPE DIAMETERS 2-5 PIPE DIAMETERS The best locations are greater than 5 diameters upstream or 10 diameters downstream from the junction. T-Junction (errors are estimated for flow at 10 ft/sec) (3 m/sec) Installation and Operation: Multi-Mag Model 285 45

Appendix, Application Schematics The best locations are greater than 5 diameters upstream or 10 diameters downstream from the junction. Y-Junction (errors are estimated for flow at 10 ft/sec) (3 m/sec) 46 Marsh-McBirney, Inc.

Appendix, Application Schematics NO YES Recommended insertion angle for active valves. The purpose of an active valve is to vary the flow. An active valve will produce a distorted profile that changes as the flow changes. As a result, the sensor should be installed at least 10 diameters upstream or 25 diameters downstream from an active valve to obtain 1% accuracy. The upstream side is the preferred location. Active Valves (errors are estimated for flow at 10 ft/sec) Installation and Operation: Multi-Mag Model 285 47

Appendix, Application Schematics The best locations are greater than 10 diameters downstream or 1 diameter upstream from the junction. Small-Large Pipe Junction (errors are estimated for flow at 10 ft/sec) 48 Marsh-McBirney, Inc.

Appendix, Application Schematics There may not be enough room in some pump stations to allow for the sensor to be installed an appropriate distance downstream from the last pump. If this is the case, the sensor will have to be installed in a manhole outside the pump station. Check with MMI for instruments that are best suited for pump station applications. Pump Station (errors are estimated for flow at 10 ft/sec) Installation and Operation: Multi-Mag Model 285 49

1/28/99 Multi-Mag Mounting Hardware CAUTION 1-7/8 (48 mm) clearance must be maintained through valve and the pipe wall to allow sensor insertion. MULTI-MAG SENSOR SPECIFICATION SHEET Note: Production cannot proceed without this information. AVAILABLE FROM MARSH-McBIRNEY AS ACCESSORIES 9 PVC valve\pvc nipple 43057\43058 Bronze valve\stainless nipple 43055\43060 Stainless Steel valve\nipple 43059\43060 Bronze corporation stop AWWA/CC Inlet 2 NPT Outlet 438000401 2" 2 1 2 " 1 6 " VALVE HEIGHT 8 6 1 " 8 6" 2 1 2 " NIPPLE HEIGHT NIPPLE HEIGHT (customer supplied dimension) Pipe Material Schedule Number Total Cable Length Company Name Site Tag/ID Customer Contact Date Received Sales Order Coordinator 2" CLEARANCE REQUIRED A 2" COMPRESSION SEAL HEIGHT B 2 1 2" IMPORTANT Customer Supplied Fitting Must Be 2" NPT Female VALVE HEIGHT CUSTOMER SUPPLIED DIMENSION NIPPLE HEIGHT C D PIPE THICKNESS E CUSTOM STACK HEIGHT ADD A-E S CHECK HERE TO USE STANDARD STACK HEIGHT (15 ). C+D+E MUST BE LESS THAN 10.5 INSIDE DIAMETER OF PIPE ID Installation and Operation: Multi-Mag Model 285 50

Specifications Measurement Volumetric flow in filled flow conduits 4" (101.6 mm) to 60" (1.5 m) utilizing insertable electromagnetic averaging sensor. Flow indication in English Std. or Metric units. Contact factory for larger pipe sizes. Flow Measurement Method: Electromagnetic Zero Stability: ±0.03 ft/s (±.009 m/s) Range: +20 ft/s (+6 m/s) Pipe sizes under 24" (600 mm) +10 ft/s (+3 m/s) Pipe sizes 24" to 42" (600 mm to 1m) +7.5 ft/s (+2.3 m/s) Pipe sizes 43" to 60" (1m to 1.5m) Contact factory for pipe sizes >60".(1.5m) Accuracy: ±1% of reading from 0 to +20 ft/s + zero stability Has reverse flow indication. Linearity: 0.3% of range Repeatability: 0.20% of range Materials Sensor: Fiberglass Cable: Polyurethane outer jacket Insertion Hardware: 316 stainless steel exposed to flow Compression Seal: Silicone rubber Sensor Electrodes: Carbon 4 to 5 probes (92 mm to 144 mm) have 2 electrode pairs 6" to 11" probes (145 mm to 299 mm) have 3 electrode pairs 12" to 60" probes (300 mm to 1.5m) have 5 electrode pairs Transmitter Enclosure NEMA 4X/IP65. Separate termination and electronics compartments. Glass filled polypropylene with clear polycarbonate cover. Dimensions: 8.4"H x 6.4"W x 2.8"D (214 mm x 163 mm x 70 mm) Weight: 3.2 lbs. (1.5 kg) Potable Water Applications Suitable for use in contact with potable water. Water Byelaws Scheme (WBS) Approved Product. Meets BS6920 Cert. #9706516. Configuration and Set-Up Programming can be easily done on site using the keypad. Two levels of user defined password protection are provided. Outputs Analog: Galvanically isolated and fully programmable for zero and full scale. Output capability <16V (800 ohm, 4-20 ma). Secondary range enabled by external input or programmed alarm condition as a percent of full scale. Pulse/Frequency: One frequency/pulse output for flow rate or for external totalizer. Isolated protected transistor switch capable of sinking <250 ma @ <35V. Dual Alarms (2 separate outputs): Isolated protected transistor switch capable of sinking <250 ma @ <35V. Note: Not isolated from frequency output. Fully programmable for high/low flow rates. % of range, empty-pipe, fault conditions, forward/reverse, polarity (normally open/close), analog over-range, pulse overrange, pulse cutoff, etc. Environmental Pressure/temperature limits: Sensor: Flow temperature range Standard: 32 to 110 F (0 to 44 C) @ 250 psi Optional: 32 to 175 F (0 to 80 C) @ 250 psi Electronics: Temperature limits: Operating: -14 to 140 F (-20 to 60 C) Storage: 5 to 167 F (-15 to 75 C) Electrical Connections 0.5 inch NPT with gasket seal Keypad and Display Can be used to access and change all setup parameters using four membrane keys and 3-line display. 3-line, 16 character, backlit LCD display with large 1/2" numerals for flow rate and two lines for engineering units, totalizers, alarm status, velocity and percent of range. Isolation Galvanic separation to 50VDC between analog, pulse/alarm, and earth/ground. Electrical Safety Meets ANSI/ISA-S82.10-1988 and S82.03-1988. Power Supply Universal switch mode. AC: 85 to 265V 45 to 400 Hz at 20VA max. or DC: 11 to 40V at 20VA max. AC or DC must be specified at time of ordering. Vibration Specification Meets BS2011: Part 2.1Fc: 1983 Internal Totalizer 9-digit totalizer. Can be programmed to reset via external input or the keypad. Reset from keypad can be password protected. Test Mode and Output Circuit Loop Verification After transmitter has been programmed, operation of the test mode will drive all outputs to programmed value, providing a total system test. Ordering Information Multi-Mag flowmeter includes modified NEMA 4X/IP65 (separate termination and electronics compartment) glass filled polypropylene electronics enclosure with polycarbonate window, electromagnetic velocity sensor with 20' cable, 4 membrane keys for configuring the transmitter, 3-line LCD backlit display with one line of 5-1/2" numerals for flow rate indication and 2 lines containing 16 characters for viewing engineering units, velocity, totalizer, alarm status and flow rate expressed as a percent of full scale, one flow proportional contact closure or frequency output, one 4-20mA output of flow rate and one instruction manual. Options include high temperature sensor, extended sensor cable (maximum length 500'), pole mounting kit, insertion tool, sun shield, and additional instruction manuals. Contact factory for sensor mounting hardware ordering information. Installation and Operation: Multi-Mag Flowmeter, Model 285 51

Model 285 Ordering Information Model 285 Ordering Information The standard Model 285 includes: NEMA 4X (IP65) enclosure 4-key keypad 3-line backlit LCD display One flow-proportional frequency output One 4-20 ma flow output Two alarm outputs Multi-Mag Sensor 20-foot sensor cable Installation and Operation Manual Options Extended sensor cable (maximum length 300') Pole mounting kit Sensor insertion tool High temperature sensor (175 F/80 C) Sun shield Additional Installation and Operation manuals Power option The standard features and options required are designated by the ordering number (285-X40X_). 90 to 265 VAC 45 to 400 Hz 1 11 to 40 VDC @ 20VA max 3 Sensor length range (S, N or L depending on pipe ID) Cable length (0 for Std. Cable or 1 for additional sensor cable) NOTE A Sensor Specification Sheet (page 5) should be completed and submitted with all orders. 52 Marsh-McBirney, Inc.

Model 285 Ordering Information Spare parts list Part Number F1-AC, 500mm fuse for AC unit... 180002101 F1-DC, 3.15A fuse for DC unit... 180002102 Option parts list Part Number Installation and Operation Manual... 105004101 Sensor insertion tool... 75031 Additional 1/2" NPT cable glands (.187/.250 O.D.)... 92125 Sun shield...0624b339001 Pole mounting kit... 245000801 Sensor cable (specify length up to 300')... 36001 High temperature sensor... SPECIAL Installation and Operation: Multi-Mag Model 285 53

Model 285 Ordering Information Returning a unit for repair If the unit needs to be returned to the factory for repair, please do the following: Prior to calling the MMI Service Department, determine the model number (285), serial number (located inside the front panel), and reason for return. Call the MMI Customer Service Department (1-800-368-2723) and ask for a Return Materials Authorization (RMA) number (FAX 1-301-874-2172). Ship the meter in the original packaging, if possible. Do not ship manuals, power cords, or other parts with your unit unless required for repair. Please make sure the meter is free from foreign debris prior to shipping. Write the RMA number on the outside of the shipping box. All return shipments should be insured. Address all shipments to: Marsh-McBirney, Inc. RMA #XXXXXX 4539 Metropolitan Court Frederick, MD 21704-9452 54 Marsh-McBirney, Inc.