Transfer switch OT III open or delayed transition, non-automatic

Similar documents
Transfer switch OTEC open or delayed transition

OTEC Transfer switch open transition

Transfer switch OTEC and OTECSE open transition

OTPC-SE Service entrance transfer switch open transition

Transfer switch OHPC open or delayed transition

CHPC Transfer switch closed transition

Transfer switch OTPC open, closed, or delayed transition

BTPC Bypass isolation transfer switch open or closed transition

Transfer switch GTEC open or delayed transition

OTPC Transfer switch open and closed transition

GTEC Transfer switch open transition

GTEC Transfer switch Open transition

Diesel generator set C17D5T series

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

OHPC/CHPC Transfer Switches

Model KCS/KCP/KCC. Automatic Transfer Switches Standard Any Breaker Rated. Transfer Switch Standard Features. Standard-Transition Models (KCS)

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Model KCS/KCP/KCC. Automatic Transfer Switches Standard Any Breaker Rated. Transfer Switch Standard Features. Standard-Transition Models (KCS)

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Zenith ZTX. GE Energy Digital Energy. Automatic Transfer Switch

Quick Start Guide TS 910

A. Submit manufacturer's literature and technical data before starting work.

Quick Start Guide TS 910 & TS 920

AT30 SERIES BATTERY CHARGER

SECTION MOTOR CONTROL

Zenith ZBTS/ ZBTSD/ZBTSCT

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

EBMC Combination Line Starters and Enclosures

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

ASCO Low Voltage Automatic Transfer Switch Systems

Paralleling Equipment

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Circuit Breaker Enclosures Section 7 NEMA Type 1

F-Series. Circuit Breaker

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

F-Series. Circuit Breaker

Horizontal Circuit Switchers

TS880 AUTOMATIC TRANSFER SWITCHES

The Total Source for Enclosures and Control Products. Gulf Coast Modification Center

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

University of Houston Master Construction Specifications Insert Project Name

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

Circuit Breaker Enclosures. Section 4.

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set QSX15 series engine

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Florham Park, NJ USA Call (ASCO) for sales or service

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Vintage Westinghouse panelboards

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Horizontal Circuit Switchers

Medium Voltage Metal-Enclosed Switches

3. Coils shall be of molded construction

Diesel generator set QSX15 series engine

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

Florham Park, NJ USA Call (ASCO) for sales or service

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

BUSWAY Low Voltage (Pow-R-Flex)

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Medium Voltage Metal-Enclosed Switches

PB-Series. GFCI/ELCI & Panel Seal

Section 4: Circuit Breaker Enclosures

Spark-ignited generator set

Vigilant Automatic Transfer Switches

IN2 Enclosed Switches and Circuit Breakers

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Section 3. Molded Case Circuit Breakers.

Diesel generator set QSK23 series engine

Design Standard. Purpose: Design Standard:

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

Diesel generator set QSK60 series engine

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Spark-ignited generator set

Molded Case Circuit Breakers Industrial Circuit Breakers A Thermal Magnetic Trip. Section 3. BuyLog Catalog 3-29

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

RXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Available Models. Automatic Transfer Switch Amps

Diesel generator set QSK23 series engine

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bypass/Isolation Switches RTS-03 SERIES

Transcription:

Specification sheet Transfer switch OT III open or delayed transition, non-automatic 40 1000 amp Description The Cummins OTIII non-automatic transfer switch offers flexibility when remote controlled or manual transfer or retransfer of load is required. Non-automatic transfer switches are used in conjunction with an automatic transfer switch which monitors the normal power source and remotely signals the nonautomatic transfer switches to transfer and retransfer load. With a non-automatic transfer switch, an operator or control device initiates transfer of a portion of the peak load from the utility to an energized Standby power source. Load shed from the Standby power source is standard. The non-automatic transfer switch allows an operator to manually transfer from a utility or Prime Power source to a Standby power source in the case of a power failure or when there is maintenance or exercising requirement. Features Assembly features - Plug connections between switch and control to facilitate service. Door mounted controls - Provide easy access for adjustments and service. Ample space for field power and control connections. Terminal markings compatible with generator set. Positive interlocking - Mechanical and electrical contactor interlocking prevents sourceto-source connection through power or control wiring. Local/remote operation modes - Can be operated locally with a door-mounted keyswitch or remotely via input signals from an automatic transfer switch or other control device. Main contacts - Heavy-duty silver allow contacts and multi-leaf arc chutes are rated for total system transfer. Warranty and service - Backed by a comprehensive warranty and worldwide distributor network. All switches are UL 1008 Listed with UL Type Rated cabinets and UL Listed CU-AL terminals. All switches are certified to CSA 282 Emergency Electrical Power Supply for Buildings, up to 600 VAC. All switches comply with NEMA ICS 10. This transfer switch is designed and manufactured in facilities certified to ISO9001

Transfer switch mechanism A bi-directional linear motor actuator powers OT III Transfer Switches. This design provides virtually friction-free, constant force, straight-line transfer switch action with no complex gears or linkages. Independent break-before-make action is used for both 3-pole and 4- pole/switched neutral switches. On 3-pole/switched neutral switches, this action also prevents the objectionable ground currents and nuisance ground fault tripping that can result from overlapping designs. A mechanical interlock prevents simultaneous closing of normal and emergency contacts. Electrical interlocks prevent simultaneous closing signals to normal and emergency contacts and interconnection of normal and emergency sources through the control wiring. Long-life, high pressure, silver alloy contacts resist burning and pitting. Separate arcing surfaces further protect the main contacts. Contacts are mechanically held in both normal and emergency positions for reliable, quiet operation. Superior arc interruption is accomplished through multiple leaf arc chutes that cool and quench the arcs. Barriers separate the phases and prevent inter-phase flashover. Specifications Operating temperature Storage temperature Humidity Altitude Surge withstand ratings Total transfer time (source to-source) -40 F (-40 C) to 122 F (50 C) -40 F (-40 C) to 140 F (60 C) Up to 95% relative, non-condensing. Up to 10,000 ft (3,000 m) without de-rating. Performance tested per IEEE-587-1980 procedure. Will not exceed 6 cycles at 60 Hz with nominal voltage applied to the actuator and without programmed transition installed. Certifications All switches are UL 1008 Listed with UL Type Rated cabinets and UL Listed CU-AL terminals. All switches are certified to CSA 282 Emergency Electrical Power Supply for Buildings, up to 600 VAC. All switches comply with NEMA ICS 10. This transfer switch is designed and manufactured in facilities certified to ISO9001.

UL withstand and closing ratings The transfer switches listed below must be protected by circuit breakers or fuses. Referenced drawings include detailed listings of specific breakers or fuse types that must be used with the respective transfer switches. Consult with your distributor/dealer to obtain the necessary drawings. Withstand and Closing Ratings (WCR) are stated in symmetrical RMS amperes. Transfer switch ampere WCR @ volts max with specific manufacturers MCCBs 40, 70, 125 14,000 @ 480 V 14,000 @ 600 V 150, 225, 260 30,000 @ 480 V 30,000 @ 600 V 300, 400, 600 65,000 @ 480 V 65,000 @ 600 V 800, 1000 65,000 @ 480 V 50,000 @ 600 V Max MCCB ratings Molded case circuit breaker manufacturer 225 A GE Westinghouse 400 A GE Westinghouse 1200 A GE Westinghouse 1400 A GE Westinghouse Molded case circuit breaker type TBC,THFK, TFK, TFJ, THED, TED HMA, MA, JB, KB, FB, EHB, FDB, FD, HFD, FDC, JDB, JD, HJD, JDC, LA, LAL, LAB, LH, LHL, LHB, KAL, KHL, HJ, KM, HEB, FJ TJJ, THFK, TFJ, TFK, HLA, LB, HLB, KDB, KD, HKD, KDC, JDB, JD, JDC, LA, LH, LAB, LHL, LHB, HJ, HM, CJ, HN, JJ TKM, THKM, TJC, TB8, TKHSS, TKSH, TJSS, TJS, TBC, NB, HLC, LC, HLA, LA, HNB, PB, LAB, MA, RD, MA, MHL, PHF, PAL, PHL, PAF, LA, LH, JL, HJ, HL, LL, KM, HK, HN, HP TPR, THR, TPRR, THRR, TPSS, THSS, TPMM, THMM, TKMA, THKMA, PB,NB, HNB, MA, HMA, RD, PA, PAL, MA, MAL, MH, MHL, PAF, PHF, PHL, NHF, NHL, PCF,NX, HP, CP, HR, KM, HN, KP, KK, CR, SKP, SKM, SHK, SHP, HM, CM Fuse protection Transfer switch ampere WCR @ volts AC maximum with current limiting fuse Max. fuse, size and type 40, 70, 125 200,000 @ 600 200 A class RK1, RK5 400 A class J 150, 225, 260 200,000 @ 600 600 A class J, RK1, RK5 1200 A class L 300, 400, 600 200,000 @ 600 1200 A class L 800, 1000 200,000 @ 600 2000 A class L

Enclosures The transfer switch and control are mounted in a key-locking enclosure. Wire bend space complies with 2008 NEC. Dimensions - transfer switch in UL type 1 enclosure Depth Amp rating Height Width Door closed Door open Weight Outline drawing in mm in mm in mm in mm lb kg 40, 70, 125 27 660 20.5 520 12 305 31.5 800 82 37 0310-0544 150, 225 35.5 900 26 660 16 405 41 1042 165 75 0310-0414 260 43.5 1105 28.5 725 16 405 43 1093 170 77 0310-0540 300, 400, 600 54 1370 25.5 650 16.5 420 40.5 1029 225 102 0310-0416 800, 1000 68 1730 30 760 19.5 495 48.5 1232 360 163 0310-0417 Dimensions - transfer switch in UL type 3R, 12 or 4 enclosure Depth Amp rating Height Width Door closed Door open Weight Cabinet type Outline drawing in mm in mm in mm in mm lb kg 40, 70, 125 34 865 26.5 675 12.5 320 36.5 927 125 57 150, 225 42.5 1080 30.5 775 16.0 406 44 1118 215 97 260 46 1170 32 815 16.0 406 46 1168 255 102 300, 400, 600 59 1500 27.5 700 16.5 420 41.5 1054 275 125 800, 1000 73.5 1865 32.5 825 19.5 495 49.5 1257 410 186 3R, 12 0310-0453 4 0310-0445 3R, 12 0310-0454 4 0310-0446 3R, 12 0310-0455 4 0310-0447 3R, 12 0310-0456 4 0310-0448 3R, 12 0310-0457 4 0310-0449 Dimensions 3- and 4-pole open transfer switch* Depth Amp rating Height Width Door closed Door open Weight 3-pole 4-pole in mm in mm in mm in mm lb kg 40, 70, 125 16.5 419 12 305 NA NA 8 205 20 9 0310-0692 NA 150, 225,260 22.5 570 19 485 19 485 12 305 50 23 0310-0692 0310-0693 300, 400, 600 28 710 19 485 19 485 15 380 80 37 0310-0692 0310-0693 800, 1000 37.5 955 22.5 570 22.5 570 17 430 150 68 0310-0692 0310-0693 * - Approximate dimensions only. For exact construction details, obtain outline drawing listed in table from your distributor. ** - Approximate weight only.

Transfer switch lug capacities All lugs accept copper or aluminum wire unless indicated otherwise. Amp rating Cables per phase Size 40, 70, 125 1 #12 AWG-2/0 150, 225 1 #6 AWG-300 MCM 260 1 #6 AWG-400 MCM 300, 400 1 3/0-600 MCM or #4 AWG-250 MCM 600 2 250-500 MCM 800, 1000 4 250-500 MCM 40, 70, 125 1 #12 AWG-2/0

Submittal detail - options Amperage ratings: 40 70 125 150 225 260 300 400 600 800 1000 Voltage ratings: R020 120* R038 190 R021 208 R022 220 R023 240 R024 380 R025 416 R035 440 R026 480 R027 600 * Line to neutral voltage (not available on 800-1000 amp switches) Pole configuration: A028 Poles - 3 (solid neutral) A029 Poles - 4 (switched neutral) (not available from 40-125 amp) Frequency: A044 60 Hertz A045 50 Hertz Application: A038 Non automatic/remote System options: A041 Single phase, 2-wire or 3-wire (not available 800-1000 amps) A042 Three phase, 3-wire or 4-wire Enclosure B001 Type 1: general purpose indoor (similar to IEC type IP30) B002 Type 3R: intended for outdoor use (dustproof and rainproof) Available 40-1000 amps only - similar to IEC type IP34). B003 Type 4: indoor or outdoor use (watertight). (Available 40-1000 amps only - similar to IEC type IP65) B004 Open Construction: no enclosure - includes automatic transfer switch and controls. Also supplied are source connected/available lamps and selector switch to be wired by customer. Meters not available with this package. B010 Type 12: indoor use, dust-tight and drip-tight (similar to IEC type IP65). Standards A046 UL 1008/CSA A080 Seismic certification Delayed (programmed) transition Slows switch operation, for an adjustable delay period, to provide an open period during transfer (and retransfer) J021 Program transition, 1-7.5 sec. J022 Program transition, 1-60 sec. Meters D001 None D002 Door mounted (not available open construction) Voltmeter - 2.5 (63.5 mm), 2% accuracy. Ammeter - 2.5 (63.5 mm), 2% accuracy. Frequency meter - 2.5 (63.5 mm), pointer type. Phase selector switch - phase-to-phase voltage sensing on both normal and emergency sources Auxiliary relays - Relays are UL-Listed and factory installed. All relays provide (2) normally open and (2) normally closed isolated contacts rated 10A @ 600 VAC. Relay terminals accept (1) 18 gauge to (2) 12 gauge wires per terminal. L001 24 VAC coil - installed, not wired (for customer use). L002 Emergency position - relay energized when ATS in Source 2 (emergency) position. L003 24 VDC coil - normal position - relay energized when ATS in source 1 (normal) position L004 24 VDC coil - emergency source - relay energized when source 2 (emergency) available. L005 24 VDC coil - normal source - relay energized when source 1 (normal) available. Miscellaneous options M007 Load shed - from emergency (standard on non-automatic) - drives OTIII to neutral position when remote signal contact closes M008 Module - alarm - provides visual and audible indication whenever emergency power is available. N005 Terminal block - source 1/2 remote signal. N009 Power connect - bus stabs (open construction only; available on 150-1000 amps). Warranty G002 One year basic G004 Two year comprehensive G006 Five year basic G007 Five year comprehensive G008 Ten year major components Shipping A051 Packing - export box For more information contact your local Cummins distributor or visit 2017 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks of Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. S-1548 (10/17)