VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Section 633 Page 633.1 Heavy-Duty, Foot-Mounted Internal Gear Pumps Offering Full Compliance with PI 676 Design Standards for rotary positive displacement pumps in petroleum, chemical, and gas industry services. Operating Range: HL4323X Steel Externals Series 4223X & 4323X Nominal Flow Pressure Range Temp. Range Viscosity Range (GPM) 15-1100 (M 3 /hr.) 3.4-250 (PSI) To 200 PSI (Bar) To 14 Bar ( o F ) 20 F to +400 F ( o C ) 29 C to +205 C (SSU) 28 SSU to 35,000 SSU (cst) 0.1 cst to 7,700 cst Note: Lower temperatures available with special materials. Higher pressures available with factory approval. Nominal Flow Rates: N4323X Pump Size Flow Rates GPM M 3 /hr HL 30 6.8 KK 100 23 LS 200 45 Q 300 68 QS 500 114 N 600 136 R 1100 250 Series Description The Universal XPD 676 Series Internal Gear pumps are designed and manufactured to comply fully with the current version of merican Petroleum Institute s design standard for positive displacement pumps, PI 676. pplications include oil and gas and petrochemical industries where exceptional reliability is required. VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
Section 633 Page 633.2 VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Features Required by PI 676 that are standard in XPD 676 series few of the key features that are required for full compliance include: PI 682 Seal. Viking s seal chamber will accept almost any customer-specified brands and types of PI 682-compliant Category 1, 2 or 3 cartridge mechanical seals, and can provide PI seal plans to meet application requirements. Standard seal is a category 2 single mechanical seal. Carbon vs. silicon carbide with PI Plan 13. 3mm corrosion allowance above Maximum llowable Working Pressure (MWP). The XPD 676 has an additional 3mm corrosion allowance built into all pressure containing components over and above our standard steel Universal Seal series pumps. 25,000 hour L-10 life on tapered roller bearings. Standard on all sizes at maximum speed and pressure. Steel castings to be normalized and tempered. Standard. High Strength Bolting. XPD 676 features high strength fasteners stamped with manufacturer s symbol and material codes, studs on some sizes. Threaded holes are drilled and tapped to minimum 1.5X stud diameter with minimum metal around the bottom of threaded holes at least 0.5X stud diameter plus 3mm corrosion allowance, per the specification. Casing drain and seal chamber vent. XPD 676 has cast-in casing drain with NSI Class 300 RF flange and seal chamber vent to completely drain the casing before maintenance. Mounting surfaces flat and parallel. The mounting feet of XPD 676 pumps are machined to 6.3µm Ra, with flatness tolerance of 25µm. The upper surface is machined parallel to the foot, and where the pump has both bracket and casing feet (N & R sizes), the feet are machined flat and parallel, in the same plane within 150 µm/m (0.002 in./ft) of distance between the mounting surfaces after the pump is assembled. Rectangular keyways. Viking cuts rectangular keyways with required fillets and includes the key with each pump. Tapered shaft extension on shafts larger than 2.5. Viking tapers the shaft extension on the R size for easy removal of the coupling half. Non-Destructive Evaluation of castings and post-weld evaluation of any necessary weld repairs using mag particle (MT) testing Certified hydrostatic testing to 1.5X MCP Certified performance testing in accordance with Section 3.6 of the Hydraulic Institute pump standards, at the specified viscosity (from 28 to 25,000 SSU), with data including speed, discharge pressure, suction pressure, power, and capacity. Packaging for long term storage, including corrosion inhibitor applied to exposed metal parts and metal port covers to protect internals from corrosion and contaminants Documentation to include, at a minimum: Certified dimensional outline drawing llowable flange loadings Cross-sectional drawing and bill of material Mechanical seal drawing and bill of material Performance curve Certified hydrostatic test data Material certifications (traceability) Weld procedure specification (WPS) Weld maps There are many more requirements of the PI 676 specification, and Viking has designed this pump to comply with all of them, as standard. dditional Features & Benefits Besides the features required by the PI 676 standard, Viking offers many additional features and benefits that our customers commonly request, including: Jacketing to melt ambient-temperature solids like bitumen before startup. The XPD 676 features jacketed bracket and casing as standard, with option for jacketed head. Opposite ports with reversible direction of flow are standard, for easy in-line piping and the ability to transfer product in either direction or strip a line of product. O-Ring seals on head and casing joints instead of gaskets for maximum sealing effectiveness. Optional labyrinth seals on bearing housing for longest bearing life by minimizing contamination (lip seals standard). Grease lubrication standard, enabling re-greasing of pump during operation, without the need for shutdown. End clearance is easily adjusted to compensate for wear over time or for higher temperatures or viscosities, by simply rotating the threaded bearing housing. 5 Non-destructive testing procedures Performance test procedures Performance test data Data sheets applicable to proposals, purchase and as-built Installation manual Operation and Maintenance manual Spare parts recommendations and price list List of drawings and submittals Shipping list Viking XPD 676 pumps carry a five year limited warranty. VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Section 633 Page 633.3 Pump Construction and Features 1. 2. 7. 4. 3. 5. 6. 9. 10. 8. 1. Large diameter threaded bearing housing allows easy removal of cartridge seals. 2. Seal chamber accepts most brands of cartridge seals conforming to PI 682. PI Seal Plan 13 provided as standard. Other plans available. 3. Tapered roller thrust bearings provide minimum 25,000 hour L-10 life at maximum flow, pressure and viscosity. 4. Class 300 Raised Face flanges standard. 5. One-piece cast bracket provides rigid foundation to maximize seal and bearing life. 6. Non-jacketed head standard. Optional Head Jacket available. 7. Seal chamber venting port for start-up and draining pump prior to maintenance. 8. High strength fasteners have material grade and manufacturer s identification symbols applied. 9. Mounting surfaces flat and parallel for superior alignment. 10. Casing drain cast-in with NSI Class 300 Raised Face Flange to completely drain casing before maintenance. VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
Section 633 Page 633.4 VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Model Number Key Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Field 7 Field 8 L S 4 2 2 3 X Size: HL QS KK N LS R Q Shaft Seal: 4 = Mechanical Seal Basic Series Configuration Material of Construction: 3 = Steel Externals Jacketing: 2 = Jacketed Bracket & Casing 3 = Foot Mount Casing with Jacketed Bracket & Casing Series designed to comply with PI 676 Materials of Construction Component Series: 4223X and 4323X Casing Steel STM 216, Grade WCC, normalized and tempered Head Steel STM 216, Grade WCC, normalized and tempered Optional plate for head jacket Steel STM 216, Grade WCC, normalized and tempered Bracket Steel STM 216, Grade WCC, normalized and tempered Idler 23 Cast Iron STM 48 Class 35B Rotor Standard 1 Cast Iron STM 48, Class 35B Steel Fitted 4 Steel STM 148, Grade 80-40 Rotor Shaft 6 Steel STM 108, Grade 1045 Idler Pin 5 Hardened Steel STM 108, Grade 1045 Idler Bushing 6 Carbon Graphite Bracket Bushing 6 Carbon Graphite 1 KK, LS, QS and N sizes have ductile iron rotor, STM 536 Grade 60-40-18. 2 Steel fitted Q and QS sizes have steel idler. 3 HL size has powdered metal idler, MPIF Std 35 FC-0208-50. 4 Material specifiction for HL steel rotor is ISI 8620, LS steel rotor is STM 148 80-50. 5 N & R size have hardened steel/ STM 322, Grade 8620 6 Numerous material options, coatings and treatments available to satisfy specific application needs. Bearing Housing PI 682 Seal Bracket Bracket Bushing Rotor Shaft Casing Rotor Idler Head Idler Bushing Idler Pin VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Section 633 Page 633.5 Specifications Jacketed Pumps U.S. Units: Model Number Standard Port Size Nominal Pump Rating (100 SSU) Max. Hydrostatic Pressure 1 Max. Discharge Pressure for 100 SSU Liquid at rated speed 2 Max. Recommended Temp. for Standard Pump Steel Fitted Recommended bove pproximate Shipping Weight Inches GPM RPM PSIG PSIG ( o F) SSU Pounds HL4223X 3 1 ½ 30 1750 400 200 350 7,500 170 KK4223X 3 2 100 780 400 200 350 25,000 215 LS4223X 3 3 200 640 400 200 350 75,000 360 Q4223X 3 4 300 520 400 200 350 7,500 640 QS4223X 3 6 500 520 400 200 350 75,000 700 N4323X 3 6 600 350 400 200 225 75,000 1015 R4323X 3 8 1100 280 400 200 225 25,000 2050 NOTE: H-N size pumps are standard with a jacketed bracket, jacketed casing and non jacketed head. R size pump is standard with a jacketed bracket, jacketed casing and jacketed head. 1 For maximum recommended discharge pressures at different viscosities, see performance curves, which can be electronically generated with the Viking Pump Selector Program, located on www.vikingpump.com. If suction pressure exceeds 50 PSIG, consult factory. Higher pressures possible with factory approval based on application details. 2 Higher temperatures can be handled with special construction and/or extra clearances, consult factory. Temperature based on Viton seal as standard. Lower temperature limits may be required when using other seal elastomers. 3 Ports are suitable for Class 300 NSI steel or stainless steel companion flanges or flanged fittings. Metric Units: Model Number 4 Standard Port Size Nominal Pump Rating (22 cst) Max. Hydrostatic Pressure 1 Max Discharge Pressure for 22 cst Liquid at rated speed 2 Max Recommended Temp. for Standard Pump Steel Fitted Recommended bove NOTE: H-N size pumps are standard with a jacketed bracket, jacketed casing and non jacketed head. R size pump is standard with a jacketed bracket, jacketed casing and jacketed head. pproximate Shipping Weight Inches M 3 /hr RPM BR BR ( o C) cst KG HL4223X 3 1 ½ 6.8 1450 28 14 180 1,650 77 KK4223X 3 2 23 780 28 14 180 5,500 98 LS4223X 3 3 45 640 28 14 180 16,500 163 Q4223X 3 4 68 520 28 14 180 1,650 290 QS4223X 3 6 113 520 28 14 180 16,500 318 N4323X 3 6 136 350 28 14 107 16,500 460 R4323X 3 8 248 280 28 14 107 5,500 930 1 For maximum recommended discharge pressures at different viscosities, see performance curves, which can be electronically generated with the Viking Pump Selector Program, located on www.vikingpump.com. If suction pressure exceeds 50 PSIG, consult factory. Higher pressures possible with factory approval based on application details. 2 Higher temperatures can be handled with special construction and/or extra clearances. Consult factory. Temperature based on Viton seal as standard. Lower temperature limits may be required when using other seal elastomers. 3 Ports are suitable for Class 300 NSI steel or stainless steel companion flanges or flanged fittings. 4 Port sizes are inch standard, not metric design or size. VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
Section 633 Page 633.6 VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Dimensions - HL4223X.99 4X 3/4" NPT BRCKET 5.95 3.75 DRIN: 1/2" RISED FCE FLNGE WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES.32 2.38 4.25.7500.7495 2.38 4.25.19 X.12 RECTNGULR KEYWY 3.75 4X.69 VIEW - 1.61 3X 1" NPT CSING 1.56 1.45 18.10 15.35 1.19 1.32 PORTS: 2X 1-1/2" RISED FCE FLNGES WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 3.90 5.95.79.94 6.00.62.94 9.73 8.38 8.63 3.83 2X.75 11.00 3.88 2X 1/2" NPT HED 3.62 Dimensions - KK4223X 4X 3/4" NPT BRCKET 6.02 1.42 3.62 4.38 5.63 2.41 4.38 1.1250 1.1245 2.41 4X.75 2.00 4X 1" NPT CSING 1/4 X 3/16 RECTNGULR KEY 3.50 VIEW - 2.25 1.94 20.33 16.33 1.75 1.68 PORTS: 2X 2" RISED FCE FLNGES WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 1.75 7.25 7.25 6.02 1.20.59 5.13 10.42 6.50 1.75 5.12 9.13 4.38 7.74 4.25 2.00 2X.75 11.00 DRIN: 1/2" RISED FCE FLNGE WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 2X 1" NPT HED 3.87 Note: ll dimensional drawings shown with optional jacketed head. VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Section 633 Page 633.7 Dimensions - LS4223X 4X 1" NPT BRCKET 8.18 2.55 4.25 2.75 4.00 1.4375 1.4370 3.50.38 X.25 RECTNGULR KEYWY 26.59 20.65 2.44 2.75 2.06 4.00 PORTS: 2X 3" RISED FCE FLNGES WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 8.00 8.00 4X.75 VIEW - 8.18 1.38 5X 1" NPT CSING 2.55 1.52 2.25 4.75 6.68 11.24 10.00 8.39 4.55 2X.62 2X 1" NPT 12.50 HED DRIN: 1/2" RISED FCE FLNGE WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 4.00 Dimensions - Q4223X 4X 1" NPT BRCKET 8.63 5X 1-1/2" NPT CSING 3.58 5.13 5.25 5.25 1.937 1.936 4X.88 2.08 1/2 X 3/8 RECTNGULR KEY 4.44 4.26 28.06 20.62 2.69 4.50 PORTS: 2X 4" RISED FCE FLNGES WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 10.25 10.25 8.50 2.03 VIEW - 8.63 9.50 2.00 8.00 14.87 4.50 10.52 5.35 8.25 2X.88 DRIN: 3/4" RISED FCE FLNGE WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 2X 1" NPT HED 5.75 Note: ll dimensional drawings shown with optional jacketed head. VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
Section 633 Page 633.8 VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Dimensions - QS4223X 4X 1" NPT BRCKET 9.13 5X 1-1/2" NPT CSING 3.58 5.13 5.25 1.937 1.936 5.25 1/2 X 3/8 RECTNGULR KEY 4X.88 2.03 4.44 29.56 21.12 4.00 2.69 PORTS: 2X 6" RISED FCE FLNGES WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 10.25 10.25 VIEW - 9.13 2.08 9.50 4.26 4.50 8.50 8.00 14.87 4.50 10.52 5.85 8.50 2X.88 DRIN: 3/4" RISED FCE FLNGE WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 2X 1" NPT HED 5.75 Dimensions - N4323X 3.62 2.4375 2.4365 6.00 4.60 4X 1" NPT BRCKET 11.50 6.00.62 X.44 RECTNGULR KEY 37.43 26.93 4.50 5X 1-1/2" NPT CSING 3.75 3.75 2.75 11.00 5.75 PORTS: 2X 6" RISED FCE FLNGES WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 12.00 12.00 10.25 5.50 14.00 23.61 5.50 10.25 4X.88 11.50 1.66 4X.88 17.26 VIEW - 1.43 2.61 9.50 6.88 15.44 6.37 29.64 9.49 4.31 5.75 8.75 8.75 4X 1.00 2X 1" NPT HED 6.62 5.75 DRIN: 3/4" RISED FCE FLNGE WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES Note: ll dimensional drawings shown with optional jacketed head. VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Section 633 Page 633.9 Dimensions - R4323X TPERED SHFT, 3/4" TPER PER 1 FOOT 3.4375 3.4355 4X 1-1/2" NPT BRCKET 12.38 5X 1-1/2" NPT CSING 9.00 9.00 7.75 19.00 7.75 4X 1.00 VIEW - 4X 1.00 1.90.88 X.62 RECTNGULR KEY PRLLEL TO TPER 6.50 1.68 30.35 6.62 44.44 29.02 8.80 5.62 PORTS: 2X 8" RISED FCE FLNGES WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES 14.25 14.25 DETIL Y SCLE 1 : 8 12.38 6.00.12 3.50 1.15 4.25 13.50 10.00 4.00 9.75 Y 20.50 18.25 7.16 30.01 10.00 5.50 5.50 10.44 10.44 4X 1.00 3X 1-1/2" NPT HED 8.63 8.25 DRIN: 1" RISED FCE FLNGE WITH STUDS ND NUTS (NOT SHOWN) SUITBLE FOR USE WITH CLSS 300 NSI FLNGES Note: ll dimensional drawings shown with optional jacketed head. VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015
Section 633 Page 633.10 VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Printed performance curves are not available. Performance Curve Notes Performance curves can be electronically generated with the Viking Pump Selector Program. This program can be located on www.vikingpump.com for the general public. For authorized distributors, this program can be found listed under the Products tab at www.idexconnect.com. Security passwords are required to access IDEXconnect. INLET CONDITIONS: The performance curves show Based on 10 (or 15) In.-Hg., which is the standard test condition. This is not the maximum vacuum capability of the pump. NPSH (Net Positive Suction Head): The NPSH R (Net Positive Suction Head Required by the pump) is given in the table below and applies for viscosities through 750 SSU. NPSH (Net Positive Suction Head vailable in the system) must be greater than the NPSH R. For a complete explanation of NPSH, see pplication Data Sheet D-19. FOR VISCOSITIES UP TO 750 SSU See NPSH R table below. FOR VISCOSITIES GRETER THN 750 SSU (NPSH R data not available): The performance curves are based on 10 or 15 In.-Hg. While vacuums up to 20 In.-Hg. will not generally result in any loss of capacity, it is recommended that the suction line size and possibly the pump port size be increased to hold the expected vacuum to 15 In-Hg. or less. Vacuum above 20 In.-Hg. should be avoided. Refer to General Catalog, Engineering Section 510 for information on determining line size. THIN LIQUIDS: pump capacity when handling 28 SSU liquids (solvents, etc.) is shown on the 38 SSU performance curve as a broken line. Pressure shown on broken line is maximum recommended for 28 SSU liquid. Horsepower for 28 SSU is same as 38 SSU at any given pressure. Carbon graphite bushings must be used handling 28 SSU liquids. MECHNICL EFFICIENCY: The Mechanical Efficiency (expressed in percent) can be calculated using the following formula: Mechanical Efficiency = (Differential Pressure, PSI) (Capacity, GPM) (100) (Horsepower, BHP) (1715) NPSH R FEET OF LIQUID (Specific Gravity 1.0), Viscosities up to 750 SSU Steel Externals Series 4223X and 4323X PUMP PUMPS SPEED, RPM SIZE 100 125 155 190 230 280 350 420 520 640 780 950 1150 1450 1750 HL - - - 1.7 1.8 1.9 2.1 2.4 2.8 3.4 4.5 6.2 9.5 13.5 KK - 1.7 1.8 1.9 2.1 2.3 2.8 3.3 4.4 6.3 9.1 - - - - LS 1.6 1.8 2.0 2.2 2.5 3.0 3.8 5.0 7.3 10.8 - - - - - Q, QS 1.9 2.1 2.3 2.7 3.3 4.2 6.1 8.4 12.7 - - - - - - N 2.1 2.3 3.5 4.5 6.3 9.5 15.0 - - - - - - - - R 2.7 3.2 4.2 5.8 8.2 11.9 - - - - - - - - - METRIC CONVERSION: The following table has been compiled for conversion to metric values. VCUUM PRESSURE CPCITY In.-Hg (inches KPa* kpa* GPM (US gal/ LPM (Liter/ PSI (lb./in of mercury) (Kilopascals) ) BR (Kilopascals) minute) Minute) M 3 /hr 1 3.4 1 6.9 0.07 1 3.8 0.23 5 17 25 172 1.7 0.26 1 0.06 10 34 50 345 3.4 4.4 16.7 1 15 51 100 690 6.9 20 68 150 1034 10.3 25 85 200 1379 13.8 250 1724 17.2 * 100 kpa = 1 bar VIKING PUMP Unit of IDEX Corporation Cedar Falls, I 2015