Series Split Coupled Vertical In-Line Pumps. File no.: 43.10in Date: august 14, 2013 Supersedes: 43.10in Date:

Similar documents
Series Split Coupled Vertical In-Line Pumps

Series 40MF. End Suction Fire Pumps & Packaged Systems

Series SG & FTV. Suction Guides & Flo-Trex Valves

Suction Guide & Flo-Trex Valve Series

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

High Temperature Air-Cooled Hot Oil Pumps

Goulds Small Capacity Double Suction Pump

High Temperature Air-Cooled Hot Oil Pumps

Discharge diameters 1.5", 2", 3", 4", 5", 6", 8", 10", 12" & 14" HP 1 to 500. Split Coupled Vertical In-Line Pumps BVL

Series 4600F. HSC Fire Pumps & Packaged Systems

KS / SKS Vertical Split Coupled Inline Pumps

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

Centrifugal End Suction Fire Pumps

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

CE Close-Coupled End Suction Pumps. Leading The Flow. TACO.

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

GROOVED END FLO-TREX COMBINATION VALVE

4500C Series Vortex Pumps

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

SUGGESTED SPECIFICATIONS

KV / SKV Vertical Inline Pumps

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

FE Frame-Mounted End Suction Pumps. Leading The Flow. TACO.

Suction Guides. Installation and operating instructions

CRANE-DEMING VERTICAL IN-LINE INDUSTRIAL BULLETIN 3180 SECTION 38

Horizontal Split Case Fire Pump Series 4600f 60 Hz

CLOSED COUPLED CENTRIFUGAL PUMPS

PROCESS PUMPS MODEL V200 ANSI B73.2

FIRE PUMPS & PACKAGED

CLOSED COUPLED CENTRIFUGAL PUMPS

EN. 850 Filtrate Pumps. Technical Specification Pages

PWA-LF LOW FLOW ANSI PROCESS PUMP

Fire Protection. FP-XA End Suction

FI / SFI Frame-Mounted End Suction Pumps

Goulds 3181 High-temperature/Pressure Paper Stock/ Process Pumps

VSC /VSCS Pumps Technical Brochure

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PWA-IL B73.2 IN-LINE

HORIZONTAL SPLIT CASE SINGLE STAGE DOUBLE SUCTION Type AE CHECKING LIST

High Temperature Chemical Process Inline Pumps

Elite. KSB Australia Pty Ltd. Centrifugal Pump

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

Goulds 3186 High-temperature/Pressure Paper Stock/ Process Pumps

High-Temperature and Pressure Paper Stock / Process Pump

PROJ. NO SECTION HYDRONIC PUMPS

Performance curves. Performance dare To compare

PWH API 610 SINGLE STAGE OH2

Installation and operating instructions. Commercial pumps Series 4300, 4360 and 4380 Vertical In-Line pumps

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date:

Basic Hydraulic Features. Basic Mechanical Features

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

1. Wiring Diagrams: Power, signal, and control wiring.

griswold 811 performance curves

CASING COVER PLATE LUBRICATION GASKETS PRESSURE RELIFE VALVE SEAL OPTIONAL EQUIPMENT

HORIZONTAL SPLIT CASING PUMPS TYPE : UP / UPL / UPH

PWA-LF LOW FLOW ANSI PROCESS PUMP

Regenerative Turbine Pumps

PWH API 610 SINGLE STAGE OH2

Series HSC-S Pumps Technical Brochure

Series 1510 Centrifugal Pumps

ANSI DIME. Engineered for EXTREME Reliability in Chemical Processes

Goulds LF 3196 i-frame. Low Flow ANSI Process Pump with i-alert Patented Intelligent Monitoring

340 Series Double Suction Split Case Pumps

CBV Series. Circuit Balancing Valves

MULTISTAGE PUMPS TYPE RKB

LUBE OIL PUMPS. Critical Lubrication Service for: Bearings Seals Gearboxes. on... Gas & Steam Turbines Compressors Engines Starting Packages

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

AURORA 3500 SERIES MODEL 3550 ASME/ANSI B73.1 INDUSTRIAL PROCESS PUMPS

Model 3550 ASME/ANSI B73.1M Industrial Process Pumps

AURORA Series MODEL 3560 ASME/ANSI B73.1M INDUSTRIAL PROCESS PUMPS

Bulletin C Dean Pump Division. ANSI/ASME B73.1 Horizontal Process. ph2140 Telescoping Guard. ph2140 C-Face Adapter

OHV and OHVL Vertical Inline Pumps ISO (API 610)

1SV (e-sv) 60 Hz 3500 RPM

Contents. Identification

ASME END SUCTION PUMPS Catalogue K-90

Index - Section 14 End Suction Pump Semi-Open Impeller

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Axial geteilte Spiral-gehӓusepumpen Axial split case pumps ASE ( ) PUMPS I MOTORS I SYSTEMS I SERVICES

F-Series Fire Fighting Pumps

Wilo IL Vertical Inline Pumps. Engineering Specification

VCMVerticalInlineProcessPump

RS Multi-Stage, Ring Section Pumps

1SV (e-sv) 50 Hz 2900 RPM

UNIVERSAL PRODUCT LINE: CAST IRON NON-JACKETED PUMPS SERIES DESCRIPTION TABLE OF CONTENTS RELATED PRODUCTS OPERATING RANGE:

D51 D61 D71 D91 Series

NB /193 A-F2-A-BAQE

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

PWA ANSI / ASME B73.1 PROCESS PUMP

TPE /2-S-A-F-A-BAQE 3X400 50HZ

KIRLOSKAR ROMAK PUMP - RMK ISO 2858 / DIN EN / ISO 5199

Hydro MPC-E 2CRIE L GNL

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

Dolan Mechanical, Inc. 638 Johnson Road, PO Box 326 Sicklerville, NJ (856) FAX (856) NO EXCEPTION TAKEN

TPED /4-S-A-F-A-BAQE 3X400 50HZ

CENTRIFUGAL PROCESS PUMPS MODEL A100 ANSI B73.1

Goulds High-Pressure Multi-Stage Pumps

320 Series Vertical Sump Pumps

M Series. ASTM F 998 Marine Duty Pumps For Flows to 5,000 GPM

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Transcription:

Series 00 Split Coupled Vertical In-Line Pumps File no.:.0in Date: august, 0 Supersedes:.0in Date: february 0, 0

Series 00 Best commercial hvac pump design available since 99 Life cycle value at every turn: Installation Vertical In-Line pumps, being integral components of the pipework, eliminate need for inertia bases, inertia base springs, flexible pipe connectors, field grouting and alignment. Pipe hangers sized for the weight of pump, piping and fittings are the only supports required. Pipe stools, with vibration isolating pads, may be installed under each pipe leg. Space saving Greatest floor space savings result when Vertical In-Line pumps are installed with Armstrong Suction Guides and Flo- Trex valves shown on the inlet and outlet of the pump above. Equivalent base mounted, horizontal split case pumps may take three times more floor space. Maintenance The mechanical seal is the critical service item in any pump. Removal of the Series 00 split spacer coupling allows all mechanical seal components to be withdrawn for servicing, through the resulting space between pump and motor shafts, without disturbing other pump components or motor connection. Re-installing the rigid coupling brings the unit rotating assembly back to factory alignment specifications. Reliability Dynamically balanced impeller and shaft assembly rotating vertically on the Series 00 centerline translate to a quiet, long-lasting pump with minimum vibration, as static shaft deflection is eliminated. There are no pump bearings to service in the Vertical In-Line design. Series 00 is a reliable, time-proven unit with less down time. Flexibility Small footprint, low installation costs, reliable and easy to maintain. These features, combined with flow range in excess of 00 m³/hr, affirms the Series 00 as the most flexible pump design available.

Design features Single Suction Split coupled Industry standard motor designed for Vertical In-Line operation. Heavy cylindrical bracket with 0 register on each flange provides a rigid union of pump and motor. Motor shaft run-out limited to 0.0 mm (0.00") tir (Total Indicator Reading). Axially split, spacer type rigid coupling permits seal maintenance without disturbing pump or motor. Lightweight high tensile aluminum, precision bored and designed to reduce bearing load. Shaft deflection at mechanical seal limited to 0.0 mm (0.00") tir. 9 Mechanical seal, accessible and easily replaceable outside multi-spring balanced mechanical seal illustrated, see page for mechanical seal options). Gland plate with flush connection ensures liquid at seal faces and positive venting of seal chamber. 0 Dynamically balanced impeller assures smooth vibrationfree operation. 9 Radially split volute with equal suction and discharge flange sizes. Separate drilled and tapped openings for gauge, flush and drain connections. 0 Liberal inlet passageways and straightening vanes provide optimum suction performance and quiet operation. Double Suction 00-0 ( illustrated) Ribs cast integral with volute. Machined surface to accept floor support when specified. Confined casing gasket to meet stringent industrial temperature and pressure applications. osha coupling guard fully encloses access openings (not shown). 9 0 Enwave District Cooling Facility, Toronto, Canada. District Cooling Project, Phoenix, U.S.A.

Split Coupled Vertical In-Line Pumps Materials of construction pump series ansi flange rating psig construction volute gasket impeller capscrew washer acorn nut adapter cover adapter bracket stuffing box cover pump shaft coupling gland plate 00 pn bf ci f bz s ss- br- ci ci ci ss- al ss- pn ai ci f ci s ss- s ci ci ci ss- al ss- pn ab bz f bz ss- ss- br- bz ci bz ss- al ss- pn di di f ci s ss- s di di di ss- al ss- pn dbf di f bz s ss- br- di di di ss- al ss- bf - Iron body, Bronze fitted ai - All iron ab - All bronze di - Ductile iron dbf - Ductile iron, Bronze fitted al - High tensile aluminum bar bz - Cast bronze astm b grade c00 material construction code ci - Cast iron astm a class 0 di - Cast ductile iron astm a grade -- f - Fiber s - Steel br- - Brass bar astm b ss- - Stainless steel astm a type 0 ss- - Stainless steel astm a type ss- - Stainless steel astm a type Pressure/temperature parameters* Cast iron - pn flanges Pressure up to bar ( psi) Temperature upto 9 c (00 f) Ductile iron - pn flanges Pressure up to bar ( psi) Temperature upto 9 c (00 f) Design and testing standards Performance testing: hi/ansi:. gr - " & smaller, en/iso: iso 990 gr - " & smaller Flange rating: ansi b., bs/en 09- Impeller balancing: hi/ansi/en/iso 90/ Vibration/noise level: hi/ansi 9.. Pump design: hi/ansi 9. Mechanical seal: hi/ansi... Nozzle load: hi 9.., iso 99, en 99 *Please view aceonline or submittal data for full details Dr. Arnaldo Hospital for women, Sao Paulo, Brazil. Canary Wharf Tower Building, London, England.

Split coupled The axially split, spacer type rigid coupling permits seal maintenance without disturbing the pump or motor connections. The mechanical seal is accessible and easily replaced. (Outside multi-spring balanced mechanical seal is illustrated). ) Split coupling with outside seal. Axially split coupling shown with coupling guard removed. Coupling bolts are still in place. Rotating element of seal is seen below the coupling, above gland plate. ) Remove the coupling bolts. The coupling halves (with drive and annular positioning keys) are taken from motor and pump shafts. Loosen set screws on seal rotating element and slide from pump shaft. (For inside seal see step ) ) Disconnect seal flush line and remove gland plate bolts. The gland plate and seal seat may then be taken out between the space in the shafts. With inside seal the complete seal is removed following the gland plate. ) New Seal may now be installed. Reverse the procedure: Install new seal, replace gland plate, replace coupling and restart pump. Rigid coupling retains factory alignment. Sealing arrangements Armstrong series 00 split coupled Vertical In-Line pumps are available with two mechanical seal arrangements. Both can be removed easily and quickly for servicing without costly removal of the motor or pump from the piping. The high performance outside type mechanical seal combines the advantages of a multi-spring balanced seal with premium quality and is the easiest to remove. The inside type mechanical seal provides an economical alternative. Outside Balanced Mechanical Seal Arrangement Pump shaft Rotating hardware Spring(s) Secondary seal Rotating face Stationary seat Gland plate Inside Unbalanced Mechanical Seal Arrangement Throttle bushing

Typical specifications Provide Vertical In-Line (vil) pumps, single stage, single or double suction type, with pump characteristics which provide rising heads to shut off. Refer to pump schedule for pump flows and heads and motor speed, enclosure, efficiency and power requirements and other system conditions. Provide Armstrong Series 00 split-coupled type vil units, with rigid spacer type coupling. Pump construction: Pump casing - Cast iron with pn flanges for working pressure below bar ( psi) and Ductile iron with pn flanges for working pressures to bar ( psi). Suction and discharge connections shall be flanged and the same size and shall be drilled and tapped for seal flush and gauge connections. Impeller - Bronze, fully enclosed type. Dynamically balanced. Two-plane balancing is required where installed impeller diameter is less than six times the impeller width. Shaft - Provide stainless steel pump shaft. Coupling - Rigid spacer type of high tensile aluminum alloy. Coupling to be designed to be easily removed on site to reveal a space between the pump and motor shafts sufficient to remove all mechanical seal components for servicing and to be replaced without disturbing the pump or motor. Mechanical seals - Shall be stainless steel multi-spring outside balanced type with viton secondary seal, carbon rotating face and silicon carbide stationary seat. Provide stainless steel gland plate. Provide factory installed flush line with manual vent. All split coupled pumps shall be provided with a lower seal chamber throttle bushing to ensure seals maintain positively cooling and lubrication. Seal flush line accessories, if required to improve seal chamber cleanliness: Supply in the flush line to the mechanical seal a 0 micron cartridge filter and sight flow indicator, to suit the working pressure encountered. If pressures exceed m/0 ft/0 psig/00 kpa, a maintenance-free sediment separator, with sight flow indicator can be used. 9 Motor power requirements shown on the pump schedule are the minimum acceptable and have been sized for continuous operation without exceeding the full load name plate rating over the entire pump curve, exclusive of service factor. Other Armstrong products For even greater space savings, ease of installation and flexibility of use: Specify Armstrong dualarm Vertical In-Line pump. Armstrong Model SG Suction Guide Strainer Armstrong FTV-A Flo-Trex Combination Valve Two () Armstrong time proven Vertical In-Line pumps in one () casing. Eliminates a complete set of piping and fittings. Stand-by or two pump parallel operation with no loss of single pump efficiency. Remove one pump for repair while the second pump continues to operate. Armstrong dualarm Vertical In-Line Pump toronto Bertrand Avenue Toronto, Ontario Canada, ml p t + 9 f + 9 90 manchester Wenlock Way Manchester United Kingdom, m jl t + (0) f + (0) bangalore #9, First floor rd Main, Margosa road, Malleswaram, Bangalore India, 0 00 t +9 (0) 90 f +9 (0) armstrong fluid technology 0 For Armstrong Fluid Technology locations worldwide, please visit www.armstrongfluidtechnology.com