Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

Similar documents
ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

Model LA 4300 Time Delay OFF Controller

Model LA 4100 Time Delay OFF Controller

Model LA 4400 Time Delay OFF Controller

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Propeller Hooded Roof Fans

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

HBC-20 - LED HIGH BAY

INSTALLATION GUIDE AND USER MANUAL

Air Curtain. Installation, Operating and Maintenance Instructions

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Electric Vehicle Charging Station

Disconnect Combiner Box Installation Manual

OPERATING MANUAL. aeration fans. models: sa sa sa SAFETY PRACTICES

PSX-240 Enclosed Autotransformer Installation Manual

INSTALLATION GUIDE AND USER MANUAL

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Model (Circuit Tester) Model (GFCI Tester)

ISIMET Laboratory Service Panel Solenoid Enclosure

ELECTRO-MECH SCOREBOARD CO.

BMRX Series ROTARY LEVEL CONTROL

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

Manual Transfer Switch

Installation Manual & Warranty

Contactor Combiner Box Installation Manual

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

CSA CERTIFIED Conforms to UL 507

INSTALL GUIDE Dodge/RAM 5.7L HEMI

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Anchorage SS Center Model AN3050. Installation, Maintenance, and Operation Manual

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Instruction Manual For Baldor Buffers

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

ISIMET S Series Enclosure Installation, Maintenance, and Operation Instructions

Operating Instructions

BUSWAY Low Voltage (Pow-R-Flex)

5DDU-EC Series Direct Drive Upblast Roof Ventilator

poollux Power plx-pw60 & plx-pw100

BRAVO Inverter/Battery Charger. Table of Contents

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

HOG SLAT. Pit Scraper System. Installation Instructions. Take special note of any warnings or safety decals on the equipment and in this manual.

User s Manual and Operating Instructions

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

SOLAR BOLT CHARGING SYSTEM INSTALLATION GUIDE

SPC-PANEL Simplex, Single Phase Pump Control Panel

INSTALLATION MANUAL.

Power Inverter 400 MW Owner s Manual

30100 Module Installation Guide L

SECTION HVAC POWER VENTILATORS

3V SERIES SOLENOID VALVE

LEV/Wn Building A Connected World

END USER TERMS OF USE

Letter to the Customer

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

SPECIAL SPECIFICATION 6894 Communication Cabinet

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

15100 Module Installation Guide Mercedes EPA07 w/dpf

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

Kit # NM, # Installation instructions: Note: do not tighten any clamps or nuts until the last step!!

SECTION WIRING DEVICES

4V130P-430P SERIES AIR PILOT VALVE

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

MN907 No. 285B Replaces 285A LB7012

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)

FLO Home TM G5 Model. Installation guide

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Air Lift. Kit Honda Prelude ( ) PERFORMANCE INSTALLATION GUIDE

MIL-24/2600Q MIL-24/3200DQ

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Combiner Box Installation Manual

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

Illumifalls Patio Pond

Part # Instructions: Page 1

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

SECTION WELDING FUME EXHAUST SYSTEM

Instruction Manual For Baldor Tool Grinders

INSTALLATION INSTRUCTIONS

Transcription:

MAPA Products MPD-XX / Pedestal Disconnect 30, 60, 100 amp February 2014 Pedestal Disconnect Installation Instructions Parts List MAPA Products Fusible Rainproof Pedestal Mounted Safety Switch provides local disconnect of the electrical service at roof mounted equipment. The Stainless Shroud with integrally welded deck flange enables a positive weather-tight flash of the unit to the roof membrane without the need for additional flashing or pitch-pan. Features: The Standard Stainless Steel Shroud extends above roof line thirty-six inches with an additional twelve inches beneath roofline so as to permit the unit to be securely fastened to the roof structural member by securing the under-deck mounting flange to a welded deck flange. Pedestals are furnished completely assembled with Safety Switch and wiring leads. Electrical service wire cable leads for termination at the equipment are protected by Liquid-Tight Steel Core Flexible Conduit. Leads for connection to the power source below the roofline are shielded in Metal Conduit. Wiring service for the GFCI is provided in a separate flexible conduit. Wiring and Conduit sizes are according to industry standards and NEC. All connections exposed to weather are made liquid tight. Optional termination cables are available in five (5) or ten (10) foot lengths. We recommend using support devices such as MAPA Strut Supports when a distance between the Pedestal and the service equipment exceeds three feet. All safety switch disconnects are furnished with NEMA 3R Rainproof enclosure. The switch is provided with handle suitable for padlocking in the OFF position. Defeat-able front accessible door prevents opening of switch when in ON position or turning the switch ON when the door is open. Series and Model Specifics: Model Description Vac. Max rating Pedestal Only: MPX4:36/12 36 Utility Pedestal W/O Disconnect General Duty Series: Model MPD-30:36/12 General Duty Utility Pedestal - Unit utilizes Square D Model # D221NRB Safety Switch.2 wire (2 Blades and Fuse holders, 1 Neutral) 120-240 Vac. Max rating 30 amps. - UL Listed, File E2875. Designed for light to medium duty applications such as roof mounted air conditioning units and exhaust fans. MPD-30:36/12 2 Blades / 2 Fuse holders / 2 wire 240 Vac 30 amp Heavy Duty Series: Heavy Duty Series utilizes the Square D Class 3110. Switches are provided without fuses. Other configurations are available, including non-fused for heavy duty series, to meet specific design criteria. MPD-30-2X:42/12 2 Blades / 2 Fuse holders / 2 wire 240 Vac 30 amp MPD-60-2X:48/12 2 Blades / 2 Fuse holders / 2 wire 240 Vac 60 amp MPD-100-2X:48/12 2 Blades / 2 Fuse holders / 2 wire 240 Vac 100 amp MPD-30-3Z:42/12 3 Blades / 3 Fuse holders / 3wire 600 Vac 30 amp MPD-60-3Z:48/12 3 Blades / 3 Fuse holders / 3 wire 600 Vac 60 amp MPD-100-3Z:48/12 3 Blades / 3 Fuse holders / 3 wire 600 Vac 100 amp 2X= 240 VAC W/ O neutral 3Z= 600 VAC W/O neutral (3X and 4X includes Neutral Bar) Pedestals are custom fabricated for specific project requirements; these units may require a (10) day lead time for quotation and typically require a four (4) week lead time after product submittal approval. 1

Component Specifics: Pedestal 4" X 4" 304 Stainless Square Tubing, Total length indicated by suffix xx/yy Wiring Conduit Specifications: Standard Sizes AWG Amp Solid welded stainless cap tops off the Shroud. Roof Flange 304 Stainless sheet continuous welded seam at Pedestal. Under Deck Flange Welded sheet metal black painted w/ anchor bolts and trim to secure Pedestal to roof structure. Optional Features available: G GFCI-Commercial grade receptacle housed in die-cast aluminum single gang weatherproof outlet box with A Lightning Surge Arrestor- Arrestor is mounted to side of Safety Switch / 240 Single Phase or 480 Three Phase P Control Port * Suffix:xx/yy Extended shroud for above or below roofline. (Specify in model number-6" increments. ie., -54/12) Option: An upper deck cap may be specified; Fit for standard 12 x12 x10 curb (Field provided) Standard below flange di- * D 5C 5 Termination cable / Liquid-Tight Steel Core Flexible Conduit. (3 Wire W/ Ground) 10C 10 Termination cable / Liquid-Tight Steel Core Flexible Conduit. (3 Wire W/ Ground) NF Non-Fused Disconnect Only available as 600 VAC 2X to 3X 3Z to 4Z Add Neutral Assembly Available on all Disconnects * Options available for the MPX4:36/12 Conductors AWG GND Conduit Rating AWG Size 30 3 10 12 1 60 3 6 10 1 1/4 100 3 2 6 1-1/4 Unpacking the Pedestal: Parts Included: Disconnect Assembly Under-deck flange Assembly Hardware Installation Instructions Assembly Hardware is located in a plastic bag that is attached to the underside of the under-deck flange. Parts: 2 ¼ X 1 set screws 4 ¼ X 1 ½ set screws 1 weather-tight connector (only when unit is provided with termination cable.) Verify that all assembly parts are present. Recommended Installation Procedures: Support Framing: We strongly recommend that prior to the installation of this Roof mounted Pedestal Disconnect that a welded angle frame be installed at the bottom surface of the roof decking. This framing should be of sufficient size to permit the provided under-deck flange to slide freely yet firmly into the frame and rest firmly against its top. The framing should be of sufficient strength to prevent any dislodging of the Pedestal during normal operation. 2

Installation Sequencing: We recommend that the Pedestal Disconnect not be installed until the roof decking and all roof insulation is in place. A square hole should be cut in the roof insulation and deck to permit the Pedestal to pass from the roof surface through this hole to below roofline with the base resting squarely on the insulation. We do not recommend making final wiring connections to the Pedestal until all roof work associated with making the Pedestal base watertight to the roof is completed and then not until the under-deck clamp has been installed. Installation of the Pedestal: A hole approximately five inches (5 ) square should be cut in the roof decking. The hole should be centered on a angle frame welded to the roof structure below the decking. Once roof insulation is in place, cut through the insulation and place the Pedestal base squarely onto the roof surface. Square the Pedestal, pointing the safety switch in the desired direction. Refer to Figure 2 of the Instructions. Caution should be taken to assure that the Pedestal is vertically level above the roof. We do not recommend installing the Pedestal within four feet of the edge of the roof or within three feet of other roof top equipment or on any sloping surfaces of the roof. Installation of the Under-deck Flange: Once roofing work at the Pedestal has been completed, the under-deck flange should be installed. Slide the under-deck flange from below, over the lower portion of the Pedestal s shroud. Snug the flange securely to the deck and angle framing. Using the four (4) ¼ X 1 ½ set screws, secure the flange to the angle framing. Care should be taken to insure that the under-deck flange is firm against the bottom of the roof deck while tightening these set screws. See Figure 3. Next, using the two (2) ¼ X 1 set screws, securely fasten the under-deck flange to the stainless flange Refer to Figure 3 of the Instructions. Figure 3 3

Additional structural bracing should be utilized where vertical sway is detected. Attachment points are provided on the pedestal for these connections. An available accessory package MAPA Products model number M- PSA2 provides the necessary hardware to attach the pedestal to the roof structure, utilizing a ridged strut design. Figure 4 Side View. Figure 4 Weather Proofing the Pedestal: This Pedestal should be flashed and made water-tight to the adjoining roof membrane according to industry standards and project specific requirements. This work should only be performed by those skilled in the roofing trade. Installation of the Electrical Service: Only qualified electricians licensed to perform electrical work in the jurisdiction where the Pedestal is to be installed should make wiring connections or perform service to this unit. Make connections to the service wire leads using a field provided industry standard junction box. This box should be installed per industry standards and per local governing codes. It is recommended that this junction box be secured to a structural member. Where a GFCI is included in this assembly, and unless specifically approved by local jurisdiction, then the wiring connections should be housed in a separate junction box. Connections to the Electrical Power Source: We recommend that a field provided junction box be installed at the wiring termination point below the roof serving the Pedestal. If a GFCI and/or Control is included in the assembly, it is recommended that separate junction boxes be used for each circuit s termination. CAUTION: Pedestals should never be used as a means to secure safety harness attachments. CAUTION: All local electrical codes should be followed when installing this Pedestal and connecting wiring to the unit. Verify that electrical supply is disconnected prior to connection of termination or service wiring or before performing service to the unit. Electrical Service Test:. It is recommended that a thorough test and inspection of the wiring services be performed on the completed assembly prior to placing it into service. Terminations at the Device: Wiring terminations and conduit connections to the electrical device served by the Pedestal Disconnect should be made per local governing codes. Fuse Selection: Fuses are not provided with this unit. Only install fuses that comply with the specific requirements of the safety switch manufacturer. Fuse size and ratings should conform to the requirements specified for the electrical device serviced by the Pedestal. Control Port: Where the unit is provided with a control port, a pull string will extend from the port mounted on the face of the shroud, through a ½ conduit and terminate to a point below the roof line. Control cable can be routed through this conduit for field termination to the electrical device serviced by the Pedestal. This control cable should not be routed within conduit where line voltage is present. Cable and termination should be installed by a qualified building automation technician. Maintenance: A periodic test and examination of the Pedestal should be performed to assure that no damage has occurred to the unit. Immediately disconnect service to the unit and contact a factory agent if the Pedestal appears damaged or fails to operate as intended. 4

Limited Warranty: MAPA will repair or replace any defective parts or workmanship of this product for a period of one year from date of delivery. Damage caused by incorrect installation, alteration or improper usage is not warranted. Recovery rights shall be limited to the total sum of the amounts paid for the product by the purchaser. DISCLAIMER OF IMPLIED WARRANTY: THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION HEREIN. SELLER DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OF THE GOODS OR OF THE FITNESS OF THE GOODS FOR ANY PURPOSE, AND BUYER AGREES THAT THE GOODS ARE SOLD AS IS. 5