Compressed Air System Leaks

Similar documents
CAGI Data Sheets. Blower Performance Comparison. Stephen Horne, Blowers Product Manager Kaeser Compressors, Inc.

Working through the electric motor replacement maze

ROTARY VANE AIR COMPRESSORS: THE FUTURE IS NOW. Why are rotary vane compressors the leading solution for today s automotive service industry?

DID YOU KNOW THIS HOLE COULD BE COSTING YOUR COMPANY MORE THAN $12,000 ANNUALLY?

ASK THE EXPERTS: The Characteristics and Applications of the Ultrasonic Sensor (Part 2 Engines)

4 fuel-efficient driving

A prime example of a shoddy solar installation, and why you should never go for the cheapest quote! So, what s wrong with this installation?

Screw Compressors DSD SERIES. Capacities from: 424 to 1024 cfm Pressures from: 80 to 217 psig

Sigma Frequency Control

7 FAQs ebook SOLAR POWER. 7 FAQs ebook

CHASSIS DYNAMICS TABLE OF CONTENTS A. DRIVER / CREW CHIEF COMMUNICATION I. CREW CHIEF COMMUNICATION RESPONSIBILITIES

Troubleshooting of the LubeTech Grease System

Electric vs. Hydraulic Cylinders A Comparison of Technologies

A softstarter beyond the ordinary

ML SERIES RECIPROCATING AIR COMPRESSORS MASTERLINE PRESSURE LUBRICATED AIR COMPRESSORS 5 30HP

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS

YMC 2 Chiller: The new standard in chiller technology

Is Uncorrected Power Factor Costing You Money?

Energy Saving: Pneumatic Systems

ABB life cycle services Uninterruptible power supplies

Optimization of Total Operating Costs Using Electric Linear Drives

PREVOST AIR SYSTEMS WHAT THEY DO AND HOW THEY DO IT

MOTOR SURVEY. Solutions for Industry

Deister Machine Company, Inc. Heavy Duty System Saver Operating Instructions

RS SERIES ROTARY SCREW AIR COMPRESSORS FIXED SPEED ROTARY SCREW AIR COMPRESSORS HP

Your Brakes. Fundamentals of Braking

Rotary screw AIR compressors

Troubleshooting Guide for Limoss Systems

Horsepower to Drive a Pump

SIZE, SAFETY & KNOWLEDGE NINO NIZIC MANAGING DIRECTOR SOLARWATT AUSTRALIA

Contact-Cooled Rotary Screw Air Compressors. Nirvana kw ( hp)

GS Series. Rotary screw compressors. Variable Speed Drive HP

2015 Carbon footprint JTP. Date of issue: 14 th March 2016


Feed in Tariffs. What is the feed-in tariff? Guaranteed for 25 years - by the UK Government. How do I claim the feed-in tariff?

APPLICATION GUIDE. ACH580 Managing total cost of ownership of HVAC systems

Purging Air From Divider Block Lubrication Systems

The Driver s Guide to

NX SERIES DIRECT SPEED ROTARY SCREW AIR COMPRESSORS KW

Natural Gas Pipeline Safety

Optimizing Airflow on Dust, Mist and Fume Collection Systems

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks

So how does a turbocharger get more air into the engine? Let us first look at the schematic below:

Executive Summary. Solid Waste Management Program Analysis and Recommendations for Silver City, New Mexico

CCHMP Comments on ConocoPhillips Incident Report For 10/22/10 Flaring Event

Go Solar Go Green. Save the Planet, Go Green & Save Green Let us be part of your effort

Shops Enter Repair and Failure Information for Plants

How to provide a better charging performance while saving costs with Ensto Advanced Load Management

Industrial machinery and heavy equipment. Hatz Diesel. Developing a water-cooled industrial engine with the help of Siemens PLM Software

Secrets of Renewable Energy: The Real Truth. Robert B. Baker Freeman Mathis & Gary, LLP

Summer Inspections, Maintenance And Repair

Long-Term Costs and Savings of Properly Rewound Motors

Nirvana hp Variable Speed Drive Rotary Screw Compressors. The Next Generation of Compressed Air

Turbo Tech 101 ( Basic )

SILICONES GLOBAL SOLUTIONS

CRYPTOCURRENCY MORATORIUM SMALL MINER RATE IMPACT. September 4, 2018

HOW TO SAVE THOUSANDS ON FUEL WHAT YOU CAN DO TO KEEP YOUR TANK AND YOUR WALLET FULL

WHAT YOU DON T KNOW COULD BURN YOU! How To Avoid The Unknown Dangers Of Handling Fuel In Your Shop

Know your energy display. See where you could save energy and money

Presented in a Let s Discuss Public Presentation on June 5, 2018 For Residential Customers

of car-wash technology: a friction-style system that relies on 1960 s-era hydraulics to operate its many wash, polish and dry components.

But it need not be like this. Belt up or get cut up

Hydraulic Scroll Drive based on Rotodiff Technology vs. Gearbox Box Drive

Hydraulic Scroll Drive based on Rotodiff Technology vs. Gearbox Box Drive

1 Faculty advisor: Roland Geyer

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

No Nonsense Advice on Improving Your Waterborne Spray Application

INDUSTRIAL EQUIPMENT INCENTIVES FOR OREGON BUSINESS CUSTOMERS

USER MANUAL. Keep this User Manual in the vehicle on which Halos are installed.

Robot upkeep. by Terry Tupper, senior engineer, material joining segment, Fanuc America Inc. Maintenance tips for a robotic arc welding cell

Auto Glass Inspection Services. Deductible Waiver & Windshield Safety

NIGHT DRIVING SAFETY FOR SCHOOL BUS DRIVERS

Audit Follow-up. Fleet Fuel Operations (Report #0801, Issued October 18, 2007) As of March 31, Summary. Report #0811 June 20, 2008

Refrigerant air dryers FX 1-22

Reliable Temperature Compensation is Critical to CNG Vehicle Safety

REFRIGERANT AIR DRYERS FX 1-22

How To Start Your Own Trucking Company

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

TECHNICAL REFERENCE CLEANING POWER GUIDELINES TANKJET TANK CLEANER OVERVIEW BY TANK DIAMETER OPTIMIZING TANK CLEANING OPERATIONS

Rotary Lobe Blowers. Omega Series Blower Blocks Flows to 5650 cfm Pressures up to: 15 psig Vacuum down to: 15 Hg. kaeser.com

COMPRESSOR SYSTEMS MADE IN GERMANY COMBI SCREW COMPRESSORS

Plug Valve Solutions for the Upstream Exploration and Production Pipelines Production manifolds, test manifolds and other dirty services

A LIFETIME APPROACH TO ENGINE COSTS IN THE MARINE SECTOR

Waste reduction yields numerous environmental and economic benefits

ingersoll rand air compressors nirvana R kw

Crane modernization raises production, reduces liability

OBSERVATIONS ABOUT ROTATING AND RECIPROCATING EQUIPMENT

6 Things to Consider when Selecting a Weigh Station Bypass System

What makes a squirt gun squirt?

15-37 kw Rotary Screw Compressors

ALZ Electrical Solar Consumer Guide

AR No. # Low Pressure Irrigation

Take a fresh look at solar things you should consider when purchasing a solar system

WHITE PAPER. Preventing Collisions and Reducing Fleet Costs While Using the Zendrive Dashboard

Renewable Energy. Presented by Sean Flanagan

Troubleshooting Guide for Okin Systems

Managing Particle Contamination with Chevron ISOCLEAN Certified Lubricants

KOMPRESSOREN MOBILAIR M 43/M 50. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min ( cfm)

High Effective Availability Decentralized UPS HEAD-UPS (c) 3.0 High Effective Availability Decentralized UPS-HEAD-UPS(c)

Colorado oil and gas companies have conducted thousands of site inspections over the past year as required under Colorado s Regulation 7.

Transcription:

Compressed Air System Leaks The Cost, Common Culprits, Detection, and Repair Matt McCorkle, Manager of Branch Operations Kaeser Compressors, Inc.

Imagine leaving your doors and windows open during the coldest winter days. Your furnace would run nonstop to try and heat your house. Your energy bill would skyrocket. Your home would still be chilly, you d scramble to find other ways to keep warm, and your furnace would wear out more quickly. Now think of the equivalent scenario in a compressed air system. You should be thinking of the costs associated with compressed air leaks. In this paper, we ll discuss how many companies are losing thousands of dollars each year to compressed air system leaks. We will address where leaks commonly occur, leak detection methods, and practical advice for an audit and repair plan. We ll explain why an ongoing leak detection and repair program can be one of the most cost-effective measures a company can use to benefit its bottom line. The Cost of Compressed Air System Leaks Compressed air systems are in nearly every industrial facility in the United States, and the undeniable fact about those systems is: they all have leaks. The U.S. Department of Energy, supported by countless system audits, estimates the average leakage rate is 25 percent. In fact, some plants lose as much as 80 percent of their compressed air to leaks. So, if compressed air systems account for an estimated $5 billion per year in energy costs, that equates to a large amount of energy needlessly wasted and millions (if not billions) of dollars spent on lost air. In addition to added energy consumption, leaks also cost compressed air users by impacting productivity and equipment life. Let s take a closer look at how leaks can translate to large amounts of energy and money being wasted on a daily basis. Wasted Electricity Compressed air leaks are simply demands for air that create no value. Further, they consume flow needed by other productive uses. This often results in significantly decreased pressure at the points of use. To compensate, some users will then turn up the pressure at the compressor, which only makes things worse since a leak will waste more air at higher pressure. We can calculate the annual energy cost for each individual leak with the following formula: Annual cost of a leak = Leakage rate (cfm) x kw/ cfm x operating hours x $/kwh The following examples assume a typical compressor efficiency of 18 kw/100 cfm (0.18 kw/cfm), an electric rate of $0.10 per kwh, 100 psig, and nearly continuous operation: 1/16 leak at 100 psig: 6.5 cfm x.18 kw/cfm x 8,000 hours x $0.10 per kwh = $936 per year 1/8 leak at 100 psig: 26 cfm x.18 kw/cfm x 8,000 hours x $0.10 per kwh = $3,744 per year 1/4 leak at 100 psig: 104 cfm x.18 kw/cfm x 8,000 hours x $0.10 per kwh = $14,976 per year Notes: The cfm flow through a leak varies with the air pressure and the size and shape of the orifice. Compressor efficiency for a particular compressor can be found on the CAGI data sheet for that model. The average electrical cost per kw in the US is approximately $0.11/kW. Again, the above examples are the cost per leak. It s easy to see how the total annual cost of all system leaks quickly adds up. In the real world example on the following page (Figure 1), a soft drink bottling 2 Kaeser Compressors, Inc. 877-586-2691 www.us.kaeser.com

plant had leaks that made up approximately half of the average compressed air consumption. With a local industrial electricity rate of $0.13/kWh, the constant demand cost as much as $34,000 per year in electricity. It is not unusual for estimated annual savings to range from $1,500 in smaller systems to $175,000 in larger systems. Reduced Productivity Excessive leaks can also cause system pressure to fluctuate, which can cause air-operated equipment to not perform as intended. High scrap rates and automatic equipment shutdown are common symptoms of this problem. A leaky system is also illprepared to take on additional capacity when surges in production and growth occur, since the system is already working harder than necessary to meet existing production demands. Increased Service Costs Maintaining pressure in a leaky compressed air system requires the compressor to run more. More run time means more frequent maintenance and possibly reduced equipment life. The more you have to repair a compressor, the more (often unscheduled) downtime that compressor will have, further reducing productivity. Ultimately, you may end up replacing the compressor sooner because it s continually working harder than necessary, thus reducing the overall service life of the system. FIGURE 1: A soft drink bottling plant lost 200 cfm to leaks which resulted in $34,000/yr in wasted energy costs. Kaeser Compressors, Inc. 877-586-2691 www.us.kaeser.com 3

Common Culprits: The Dirty 30 and Other Frequent Problem Areas Leaks are found from the compressor all the way to the points of use. The more fittings and hoses you have, the more leaks you are likely to have. They may occur in poorly installed fittings or in joints that have loosened or degraded over time. Leakage points are often located in what Tom Taranto, a wellknown compressed air specialist, refers to as the dirty 30 the last 30 feet of piping to the point of use. This is generally the smallest piping and hose size, and gets the most vibration and stress from the point of use. Problem areas include: Condensate traps Shut-off valves Fittings and pipe joints Filters, regulators, and lubricators Disconnects Hoses End-use equipment Bag houses Cylinder rod packing Worn packing, missed welds, missing O-rings, and other issues can also be the source of costly leaks. Leak Detection Methods Too many users simply accept leaks as an unavoidable aspect of compressed air, just a cost of doing business. While it may not be practical to eliminate all leaks, it is not difficult to greatly reduce them. First, you must find them. There are three common methods of leak detection: listening and feeling, the soapy water technique, and ultrasonic leak detection. Listen and Feel A simple way to detect leaks is by listening for and then feeling leaks. This is only effective for large leaks that you can get close enough to touch. Plus you must be able to hear them above the noise of plant equipment. This technique will not work for most leaks. Soapy Water Another leak detection method is the soapy water method. Soapy water is applied with a brush to areas where a leak is suspected. If a leak is present, soap bubbles will form. Although reliable, it is time consuming, and requires direct physical access to the entire piping system. Leaks in overhead piping or in hard-to-access areas may not be detected. Further, this method does not provide information on the relative volume of each leak, leaving the user illinformed about which leaks are wasting the most air. Ultrasonic The industry standard and best practice is to use ultrasonic leak detection. This is the most versatile form of leak detection and it can detect leaks as small as a pinhole. It s both fast and accurate. Plus, it does not require plant downtime to conduct a leak detection audit, because background noise does not 4 Kaeser Compressors, Inc. 877-586-2691 www.us.kaeser.com

interfere with its results. Unlike the first two methods, it can be done without physical contact with the leaks. This method works because when compressed air is released into the atmosphere, the turbulence creates ultrasonic noise inaudible to the human ear but detectable with the right equipment. Ultrasonic leak detection equipment typically consists of directional microphones, amplifiers, and audio filters, and usually has either visual indicators or earphones to help the auditor identify the leaks. Figure 2 illustrates an example of ultrasonic leak detection equipment. Since ultrasonic is a high frequency signal, the sound from a compressed air leak is both directional and localized to the source. This allows the ultrasonic detector to sense the leak in loud, noisy environments and locate the source of the leak. Some ultrasonic leak detection devices are also able to estimate and record the volume of leakage based on the decibel level of the leak. FIGURE 2: Ultrasonic leak detection is versatile, fast, and accurate and it does not require plant downtime. Kaeser Compressors, Inc. 877-586-2691 www.us.kaeser.com 5

Expectations of an Ultrasonic Leak Audit Once the leaks are found, a smart practice is to tag each leak with a bright, durable tag to make finding the leaks easy when it comes time for repairs. Information on each uniquely identified leak should then be documented on a spreadsheet or other document that allows you to calculate leak costs and prioritize follow-up action. Some vendors even offer spreadsheet tools with this capability. Once the cost of each leak is determined, it should be easy to prioritize the most important leaks to fix first. A good leak detection audit should: Clearly identify each leak with an easily recognized tag that includes the date and a unique identifying code/number. Provide a list of leaks with their locations, unique identifier, and severity. Estimate the cost/potential savings of each leak and enable you to sort the list by leak severity. Annual Operating Hours Detailed List of Compressed Air System Leaks Prepared for: ACME Packaging Report Prepared By: Kaeser Sales Office Assumptions for Calculation Cost and Energy Avoidance Electricity Cost Cost per 1000 cubic feet Identified cfm kwh CO 2 8,760 $ 0.10 $ 0.33 $12,506.46 72 - - Tag Number Location Name Pressure at Leak (psi) db Reading Problem Description Repaired (Y/N) Work Order Identified Leaks Cost Avoidance Size of Leak (cfm) Energy Avoidance (kwh) CO 2 Avoidance (lb) 935 Compressor Room 1 125 51 Leak at fitting $671.20 3.9 N/A N/A 936 Compressor Room 1 125 54 Leak at fitting $724.63 4.2 N/A N/A 937 Compressor Room 1 125 70 Leak at fitting $1,025.95 5.9 N/A N/A 938 Compressor Room 1 125 70 Quick Coupler Leak $1,025.95 5.9 N/A N/A 939 Compressor Room 1 125 60 Valve Leak $834.50 4.8 N/A N/A 940 Compressor Room 1 125 67 Quick Coupler Leak $967.47 5.6 N/A N/A 941 Compressor Room 1 125 65 Auto drain leaking $928.97 5.4 N/A N/A 942 Compressor Room 2 125 42 Quick Coupler Leak $517.46 3.0 N/A N/A 943 Compressor Room 2 125 42 Leak inside machine $517.46 3.0 N/A N/A 944 Compressor Room 2 125 68 Quick Coupler Leak $986.87 5.7 N/A N/A 945 Compressor Room 2 125 65 Quick Coupler Leak $928.97 5.4 N/A N/A 531 Compressor Room 2 125 30 Quick Coupler Leak $329.67 1.9 N/A N/A 532 Compressor Room 2 125 50 Blow Gun Leaking $653.63 3.8 N/A N/A 533 Compressor Room 2 125 62 Bad connection $871.98 5.0 N/A N/A 530 Compressor Room 2 125 55 Bad Valve $742.67 4.3 N/A N/A 514 Compressor Room 2 125 57 Bad Valve $779.07 4.5 N/A N/A 6 Kaeser Compressors, Inc. 877-586-2691 www.us.kaeser.com

Fix the Leaks The leak detection audit creates your action plan, but it is the repairs that will actually create the cost savings. This may seem obvious; however, all too often plants conduct or pay for a leak study and do little with it. Without the follow-up, the leak detection is just another cost. Your goal is to reduce total leakage to less than 10 percent of your total compressed air production. The good news is that the Pareto Principle (80 20 rule) applies: even just fixing the top 20 percent of the leaks can reduce the total compressed air leakage by 80 percent or more. Start with the big leaks first. Repair main-system leaks during scheduled downtime. If an area can be bypassed during a repair, downtime isn t necessary. Develop an Ongoing Program It s important to recognize that leak detection and repair is an ongoing program. It will never be one and done. As a system ages or is changed, new leaks can occur in areas throughout the system, or previously repaired leaks may need further attention. Having a leak detection audit performed every 6 to 12 months as part of your ongoing efforts will keep you focused on the biggest leaks. Work with whoever performs your leak detection audit to determine the best frequency of future audits for your plant. He or she can help you establish a program that continues to maximize plant productivity and profits through leak detection and repair. Plant employees also play an important role in your leak detection and repair program. In many cases, even when the audit is contracted out, the repairs are assigned to plant staff. But even if an outside party handles the repairs, employees at all levels should be educated and encouraged to report leaks as they detect them. Oftentimes employees may be aware of leaks but do not realize the financial impact of the leaks. Overall profitability should be everyone s concern, so underscoring the benefits of eliminating leaks and dedicating resources to the task is critical. Conclusion Like a furnace heating a well-insulated home, a compressed air system with a minimum amount of leaks is more energy efficient and more effective. Leak reduction is one of the most cost-effective steps a plant can take to immediately reduce energy costs and improve profitability. Leak reduction also directly supports your company s goal to reduce its carbon footprint. An ongoing leak detection audit and repair program will quickly pay for itself through energy savings (and may even be subsidized by local utility incentive programs). Equally important, you will likely see benefits from reduced downtime and better running production equipment. All of these contribute to a stronger bottom line. About the Author Matt McCorkle lives in Fredericksburg, VA where he works as the Manager of Branch Operations for Kaeser Compressors. He holds a Bachelor s degree in Mechanical Engineering from the US Air Force Academy and a Master s of Engineering in Industrial and Systems Engineering from the University of Florida. Matt has worked as a licensed Professional Engineer and has been a certified energy manager through the Association of Energy Engineers. He was instrumental in establishing Kaeser s nationwide leak auditing program. Kaeser Compressors, Inc. 877-586-2691 www.us.kaeser.com 7

Subhead Technology Meets Tradition Occusam aut doluptat harum earum et la volest magnist rumquidus et et aut volupti isciandene se rndnis aliquo magnis dem autem nos commolor re de est, Our compressed air heritage is built on vellia ped mo te imperae a century of manufacturing experience. Generations of quality craftsmanship guide our engineering principles of efficiency, reliability, and serviceability. This tradition of excellence also drives new technology development. Advances in airend design, controls, and system design ensure our customers can meet the daily challenges of their manufacturing operations. Each Kaeser product is designed with the future in mind, but we never lose sight of our roots. Technology needs may change from year to year, but the need for quality and reliability will always remain. About the Author Matt McCorkle lives in Fredericksburg, VA where he works as the Manager of Branch Operations for Kaeser Compressors. He holds a Bachelor s degree in Mechanical Engineering from the US Air Force Academy and a Master s of Engineering in Industrial and Systems Engineering from the University of Florida. Matt has worked as a licensed Professional Engineer and has been a certified energy manager through the Association of Energy Engineers. He was instrumental in establishing Kaeser s nationwide leak auditing program. Kaeser Compressors, Inc. 511 Sigma Drive Fredericksburg, VA 22408 USA Telephone: 540-898-5500 Toll Free: 800-777-7873 www.kaeser.com info.usa@kaeser.com 2018 Kaeser Compressors, Inc. All rights reserved. 01/18 USWPLEAKS