Low Level Indicator. Part E, Section 1. This section covers the following unit configurations. 3500V 3700V 3800V 3900V E2EN 03 [3V LLI] 4

Similar documents
Series 3000V Low Level Indicator

Installation Instructions for Series 3100V Low Level Indicator

Installing the Low Level Indicator (P/N or P/N )

Installing an H-200 Integral Right-Angle Module

Series 3900/M Pump Retrofit Kit

E-200 Module Service Kit

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Maintenance. Part A, Section 5. This section covers the following unit configurations.

E-200 O-rings Service Kit

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

A CAUTION: The kit should not be fitted on Series 3800 or 3900

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N

Rhino SD2/XD2 Electric Container Level Sensors for 125-mm Frames

Preventive Maintenance for Pail Melters

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

5000 Gerotor Pump Service Instructions

Blow Off Valve Retrofit Kit

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

SP30 10:1 Piston Pump

Nordson/Drexelbrook Material Level Control Kit

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

Solenoid Valve Installation Kit

Swivel I/O Manifold. 3. Operation After intallation, no further attention to the swivel manifold is required. Foam AG-900 Swivel I/O Manifold 1

Sure Coat 90 Degree Spray Extension

Installing the Integral Platen Blow Off Valve

Prodigy HDLV Manual System Installation Instructions

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6

SPRAY RUN-UP CONTROL KIT ( 4-20 ma Version)

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA

Miniature Soft Seat Fluid Pressure Regulator

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2012 Supersedes

Operation & Maintenance Manual

Two Component Meter Cylinder Assembly Replacement

B Manifold K or O Assembly Parts List. Parts

TCU Flushing Manifold and RTD Installation

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

Pro-Swirl Manifold Air Heater

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

CHEVROLET/GMC K10 - K20 - K BLAZER/JIMMY/SUBURBAN/CREWCAB CAB CHASSIS 4X ATTACHMENT KIT

KENT/Euroclean MODELS: (2)

Dealer Instructions for SETUP and PRE-DELIVERY SERVICE HS928K1 HS1332 SNOWBLOWERS

Circulation Kits for CP Pumps

Upgrading the Sure Coat Modular Gun Control System

Inverted High Pressure Fluid Filters

Rear Quick Attach System Kit For Groundsmaster 7200/7210 Series Mower

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

Mobile Powder Spray System Dolly with Hopper

MASTERsine Inverter PXA Series Installation Guide

PARTS MANUAL. American Dish Service ADS CONVERTIBLE DISHWASHER MODELS: AF3D / AFC3D EFFECTIVE: APRIL 1, 2002

THANK YOU FOR CHOOSING KÜRYAKYN! -cont.-

Fuel supply system, servicing (vehicles with front wheel drive and 1.8 ltr. turbo or 2.8 ltr. engine)

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

CHEVROLET/GMC K K K3500 4X BLAZER/JIMMY 4X ATTACHMENT KIT

- GF TELE JIB - INSTRUCTION MANUAL - JULY Tel.: +49 (0)

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit

2007 Dodge Nitro R/T

Lube Level Maintainer

Prodigy to Encore HD Manual Powder Spray System Upgrade Kit

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit

Operating and Assembly Manual

Operating and Assembly Manual

Description. Repair. Rhinor XD2 Type-H Low Level Drum Proximity Sensor. Replacing the Proximity Sensor

Colormax Powder Coating System Color Change Process

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

B Manifold L or P Assembly Parts List. Parts

Operating and Assembly Manual

JARVIS. Model 30CL-1 AND 30CL-3 Hock Cutter and Dehorner. 30CL-1 Hock Cutter

ATS-9600/9700 TABBER/LABELER

Spray Pressure Control Manifold

FORD F150 / BRONCO 4X4

Fluidizing Pickup Tube Kits

GENERAL NOTES. This guide has been edited for the CONSUMER according to directive CE89/392 and its ensuing amendments.

Prodigy HDLV Generation II Manual System Installation Instructions

Installation and Service Instructions for Self Adjust Brakes 81,000 Series

TOYOTA RAV TRAILER WIRE HARNESS Section I Installation Preparation

Model 452-DIC/DH. Operating and Assembly Manual

ELITE HEAVY-DUTY BACK

Air Spray Proportioning Valve

Mandatory X Information Recommended Change. Series/Parts Affected: LS40D, LS40TD, LS50TD and LS60TD Concrete Pumps

Electric Vibratory Box Feeder Retrofit Kit

One-Gun Add-On Kit For Smart-Coat Controllers

Transcription:

Part E, Section 1 This section covers the following unit configurations. Model 3400V 3500V 3700V 3800V 3900V Voltage All Pump All Manifold All Control All

E 1-0

E 1-1 Section E 1 WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 1. Introduction The low level indicator sends a signal to an external device when the adhesive level in the applicator s tank is low. The external device can be a Nordson vacuum hopper feeder that automatically adds more adhesive, or a customer-supplied light that warns operators when the adhesive level is low. The low level indicator consists of a float, counterweight, lever rod, mercury switch and terminal block. The float is balanced by the counterweight to ride half in and half out of the hot melt material. As the adhesive level drops, the float attached to the lever rod drops down. The mercury switch attached to the lever rod tilts forward. This action causes the mercury switch to close and activates the terminal block. The indicator is intended for 30 VAC maximum, Class 2 circuit operation as defined in Article 725 of the National Electrical Code.

E 1-2 2. Installation WARNING: Hot! Risk of burns. Wear heat-protective clothing, safety goggles, and heat-protective gloves. Hot melt material may be released forcefully. 1. Drain the tank of all hot melt material. WARNING: The applicator contains energized electrical components with potentials that could be fatal. Disconnect and lock out input electrical power to the unit before proceeding further. Only qualified personnel should install and operate this equipment. 2. Remove the pump enclosure. 3. Remove the electrical enclosure and rear cover from the unit. 4. Remove the screws holding the pump pan to the tank cover. 5. Knock out the lever rod opening on the tank cover.

E 1-3 2. Installation(contd.) 1 8 2 3 7 6 5 4 Fig. E 1-1 1. Indicator assembly 2. Float 3. Tank barrier 4. Center frame 5. Wires to customer-supplied remote device 6. Wires to 7. Terminal block 8. Counterweight 4130422

E 1-4 2. Installation(contd.) 6. Clean the tank of any debris before filling with fresh hot melt material. 7. Remove the float from the lever rod and slide the lever rod through the opening in the pump pan. 8. Mount the indicator to the pump pan and secure with the screws removed in step 4. 9. Attach the float to the lever rod. The mercury switch activates when the lever rod drops below horizontal. 10. Loosen the locking nut above the float and screw the float up or down the lever rod to the position that will produce the desired low level warning point. NOTE: The X distance in Figure E 1-2 is the distance between the low level warning point (reference groove) and the top of the tank strainer. The recommended X distance is 63mm (2.50 in). Recommended Y distance is 36mm (1.41 in). 11. Tighten the locking nut when the float is at the desired position. 12. Place the tank barrier in position around the float. 13. Fasten the terminal block bracket to the center frame. Fig. E 1-2 4103525 14. Secure the terminal block to the bracket.

E 1-5 15. Connect the indicator wires to the porcelain connector on the indicator. 16. Route the wires behind the tank and through the recess in the center frame, then bring them up to the terminal block. 17. Connect the indicator wire ends to the terminal block. 1 2 Fig. E 1-3 Connecting wires to the terminal block 1. Wires to low level indicator 2. Wires to customer-supplied remote device 4130432 18. The low level indicator can now be connected to a remote device provided by the customer. Connect the wires from the remote device to the terminal block directly across from the wires to the low level indicator. 19. Replace the electrical enclosure and the front cover. Replace the pump enclosure and tighten the locking screw.

E 1-6 3. Setup WARNING: Hot! Risk of burns. Wear heat-protective clothing, safety goggles, and heat-protective gloves. CAUTION: Remove the retaining rubberband from the float assembly before proceeding to prevent the melted rubberband from falling into the tank. 1. Fill the applicator with hot melt material and begin operation according to the Operation section of the manual. 2. When the low level warning indicator comes on, open the tank cover and remove the tank barrier. 3. Observe where the float rides on the surface of the hot melt material. 4. If the reference groove is below the adhesive surface, remove the pump enclosure, loosen the locknut on the counterweight and turn the counterweight so that it moves away from the pivot point of the lever rod. Continue turning the counterweight until the groove floats at the surface. ADHESIVE LEVEL 5. If the reference groove is above the surface, turn the counterweight so that it moves closer to the pivot point of the lever rod. Continue turning the counterweight until the groove floats at the surface. NOTE: If the hot melt material is changed to one with a different specific gravity, readjust the counterweight. 4130423 Fig. E 1-4 Float Reference Groove 6. Tighten the locknut against the counterweight. 7. To adjust the low level warning time, re-position the float up or down on the lever rod. NOTE: Tank capacity must be at least 50% when the mercury switch activates. 8. Replace the pump enclosure. The low level indicator is ready for operation.

E 1-7 4. Parts List Part Description Quantity Note 302 891ÁÁ Service kit, Level Indicator 119 164ÁÁ Level assembly indicator Á 1 A ÁÁ 120 576 Tank barrier 1 ÁÁ 983 005 Washer, flat, 0.094 x 0.250 x 0.020 inch 2 288 160ÁÁ Screw, Hi Lo, Pan Hd, Rec, 2-18 x 1.00 inch Á 2 100 661ÁÁ 4 station marker strip Á 1 249 791ÁÁ Terminal block bracket Á 1 100 664 ÁÁ 4 station terminal control block Á 1 ÁÁ 982 430 Screw, Pan Hd, Slt, M3 x 16 mm 2 302 883 ÁÁ Wire group 1 Á NOTE A: The level assembly indicator includes a mercury switch (P/N 126 674).

E 1-8