Report on the product testing, monitoring and evaluation of the FPC according to the contracted supervision Product type MDF El

Similar documents
Test Report /Al (Results with Batch 1) Vastern Timber Company Ltd. Wootton Bassett, Swindon

Test Report Order No _A1 / Part Hessisch Oldendorf. Order: Test of the electrostatic properties of a resilient floor coverings coated

TEST REPORT Report No.: R-cn E-S2 Page 1 of 9

Test Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK

APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of. Nanjing Feeling Rubber & Plastic Produces Co., Ltd. EPDM Rubber Granule

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Name of Laboratory : SGS CAMBODIA LABORATORY Accreditation Number : Testing : 1076 A-C, Street 371, Sangkat Stung Meanchey, Khan Meanchey,

Applicant: INTEX DEVELOPMENT COMPANY LTD. Date: Jul 14, /F, DAH SING FINANCIAL CENTRE,108 GLOUCESTER ROAD,WANCHAI, HONG KONG.

TRACE ELEMENTS IN URINE

TRACE ELEMENTS IN URINE. Event #3, 2012

Certificate of Accreditation

POL. IND. LA VARIANTE. MONTE LA PILA, LARDERO (LA RIOJA) SPAIN Marta Montero Product Name:

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

To the participants of AQS Baden-Württemberg Dear Madam or Sir,

Safety and Quality 2.0 Bike Specifications

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

Proposed Sydport Container Terminal-Sydney Harbour Sediment Quality Analysis

European Regulations for Formaldehyde

SERVICE. Condition Monitoring Service Oil Check Condition Monitoring. Lubricant analysis Schwingungsanalyse Vibration SmartCheck

Radionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x

Variation Notice with introductory note

Evaluation report. tests of material samples for the parameters heavy metals (Pb, Cd, Cr, Cu, Ni, Zn, Hg) LVHH, BTEX, PDH, PAH and EOX

Experiences with domestic waste treatment and co-processing of Solid Recovered Fuels (SRF)

TECHNICAL INFORMATION

Obtaining ASTM D6400- D6868 Approval

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

DECLARATION OF CONFORMITY REGARDING END-OF LIFE VEHICLES (EL V)

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

TRACE ELEMENTS IN WHOLE BLOOD. Event #2, 2010

Incinerator Monitoring Program Ash Characterization Summary

Incinerator Monitoring Program Ash Characterization Summary

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Restriction of the use of certain hazardous substances (RoHS) Summary Report

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Test-Report. Power determination on PV-Modules at Standard Test Conditions (STC) and PID-Test. PI-Report-Number: a_V2 2012/04/03

Supplier s Product Safety Warranty (EU)

MFPA Leipzig GmbH Test, monitoring and certification point for building materials, products and systems

T E C H N I C A L R E P O R T. N o. : L C A E C E R e g u l a t i o n N o. 109

4 A village survey: Mandari, Lakshmipur

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Sound-absorbing spacer Sorp10

DECLARATION OF CONFORMITY REGARDING RESTRICTIONS OF HAZARDOUS SUBSTANCES IN ELECTRICAL AND ELECTRONIC EQUIPMENT

Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Technical Report No D Dated

Emissions Testing Report

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Vertex Floors Ltd. Room B & C, 15/f Hang Seng Causeway Bay Building, 28 Yee Wo Street, Causeway Bay. P.R. China. Berlin, den

SEPA Statement Processed Fuel Oil

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

European new pellets standards Case non-woody pellets, 4 May 2010, Lyon

[Date of order] [Date of delivery] [Date]

[ Date of order ] [ Date of delivery ] [ Date ]

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018

VITLAB Dispenser. Standard Operating Procedure (SOP)

Evidence of Performance Airborne sound insulation of flat roofs

68-253/Issue 1 (DERD 2491) 1 August 1997

Non-domestic Renewable Heat Incentive Emissions Certificate

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

Überwachte Fertigungsstätte

Presentation to: Cedar Hills City Council Division of Water Quality Utah Department of Environmental Quality

CERTIFICATE TUI/NORD. Certificate-No.: 004S-CPD &v ffisee OF FACTORY PRODUCTION CONTROL ACCORDING TO DIN EN :2009, APPENDTXZA

Technical Report No Rev. 00 Dated

Certification Scheme

MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION

Synthetic Sports Surfacing Suitability Test acc. to DIN V : Description Type Single Layer with flat texture, porous

Confirmation: / 22 March 2013

Oil secure power and performance

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

Applicant: NEAT-OH! INTERNATIONAL, LLC Date: Jul 07, W FRONTAGE ROAD SUITE 303 NORTHFIELD IL USA Attn: ELAN FELDMAN

Standards for solid biofuels - Status and prospects

Test report No

TEST REPORT NO.SL64257 Date: April 14, 2015 Page 1 of 11

Water analysis, QC and more:

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

APPENDIX D WATER QUALITY DATA

2 nd use application of battery cells: functional safety requirements

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6

Non-exhaust contributions to PM levels in 5 EU cities. 39 th PMP Meeting 9-10 March 2016

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Laboratory Bureau Veritas Consumer Products Services Lanka (Pvt.) Ltd., No. 570, Galle Road, Katubedda, Moratuwa, Sri Lanka

Influence of mounting tube diameter on anemometer output

Discipline Chemical Testing Issue Date Certificate Number T-1695 Valid Until Last Amended on - Page 1 of & 2013.

Technical Report No C Dated

Guideline of the Railway Vehicles Coordination Committee (Draft Guideline DVS 1619)

DNVGL-CP-0110 Edition March 2016

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

STATE OF NEW YORK IN ASSEMBLY

Classification report No K1

Technical Report No B Dated

System Test Report Fitness for Use and Durability

Oil High-capacity and full of power reserve by premature check

Example Petition for Exemption

Evidence of performance Reduction of impact sound pressure level by floor coverings

Certificate: _01 / 20 August 2013

Degussa Construction Chemicals (Schweiz) AG Division CONICA Technik Industriestrasse 26 CH 8207 Schaffhausen October 19, 2004

Test report No

Transcription:

EPH SUCCESS BY QUALITY Entwicklungs- und Prüflabor Holztechnologie GmbH Zellescher Weg 24 01217 Dresden Germany Kronospan Sebes SA Mr. Bandi, Mrs. Calin Str. Mihail Kogalniceau, 59 515800 Sebes Jud. Alba Entwicklungs- und Prüflabor Holztechnologie GmbH Zellescher Weg 24 01217 Dresden Tel.:+49 3514662 352 Fax: +49 351 4662 211 maebert@eph-dresden.de www.eph-dresden.de Report 01-2016 on the product testing, monitoring and evaluation of the FPC according to the contracted supervision Product type MDF El - Chemical testing- Order-No. 2306 020 Client: Kronospan Sebes SA Str. Mihail Kogalniceau, 59 515800 Sebes Jud. Alba 0rder: Regular (semi-annually) product testing, monitoring, evaluation of the FPC concerning the agreed product characteristics under the supervision contract QP-Q7-04-02 including addenda Contractor: Entwicklungs- und Prüflabor Holztechnologie GmbH Zellescher Weg 24, 01217 Dresden Germany Engineer in harge: Dipl.-lng.(BA) Mäbert (certification body) This Surveillance Report contains 5 pages and 2 Annex with 1 page. Partial copying requires written approval by EPH. The test results e clusively referto the tested materials. General Manager Commerzbank AG Dr.-Ing. Bernd Devantier SWIFT: DRES DE FF 850 Amtsgericht Dresden HRB 8072 IBAN: DE 13 8508 0000 0400 2982 00 USt.-ldlMr. DE 21 60 77 4 6 DAldcS Dmjtsc o Akkroi tlonin ssti'llo D-Pl-11054-01*00 D-ZE-110S4-01-00 DIBt Deutsches Institut für Bautechnik Europäisch notifizierte Stelle für Bauprodukte 0766 Bauaufclchtllch anerkannte Stelle des DIBt SAC 03

Page 2 of 5 of Surveillance report 01-2016, Order-No. 2306 020, MDF El, Chemical testing 1 Task: Sampling for the determination of the agreed properties according to 2.3 at the EPH laboratory. Monitoring of the FPC, especially for the product type named in 2.2. Assessment of the test results of EPH. Surveillance period: until 30 September 2016 and 31 March 2017 2 Procedure 2.1 Imspection of the manufacturing site Date: Participants: Inspected facilities: Inspected documents: 2.2 Sampling 2 February 2016 Mr. Mäbert, Mr. Wünschmann -EPH Mrs. Calin -Kronospan Sebes Test laboratory, plant Documentation of internal control testing The sampling was taken from the client s stock of sanded dry process fibreboards (MDF) acc. to EN 622-5, which are produced within thickness ranges of >6-19 mm with a raw density of 750 kg/m3 ± 7 % and >19-30 mm with a raw density of 720 kg/m3 + 7 %. The representative of EPH drew the panels on 2 February 2016 from a stack of the Client s stock. Supported by Client's employees, the following 20 cross-cut Strips were cut from the panel type and then marked and sent to the test house: Nominal thickness Number of panels Number of cross-cut EPH specification Production date [mm] Strips 8 4 1 1184/1-4 20January 2016 18 3 1 1222/1-3 6 March 2016 28 4 1 1186/1-4 12 January 2016 10 3 1 1187/1-3 covered 27 January 2016 16 3 1 1188/1-3 covered 5 January 2016 25 3 1 1189/1-3 covered 11 January 2016 2.3 Carrying out and results of the tests at EPH Acc. to the requirements of EN 622-5, the following properties were established following valid test regulations: Formaldehyde content EN 120 Formaldehyde release (for covered materials) EN 717-2 P IHD-standard W 409 Lindane IHD-standard W 410 Migration of Elements EN 71-3 (2013) The formaldehyde content acc. to DIN EN 120 was in each case carried out as twin determination; the values quoted relate to a material moisture of 6.5 %. 2.4 Results of the test reports at hand The engineer in Charge organized the cutting of the received samples and handed over to the EPH test laboratory for conditioning and testing.

Page 3 of 5 of Surveillance report 01-2016, Order-No. 2306 020, MDF El, Chemical testing The results gained from the panels tested are compared with t e requirements of dry process fibreboards (MDF) acc. to EN 622-5, panel type MDF, nominal thickness ränge >6-30 mm. Table 1 Properties of the tested sample material Pro erty 1184 1222 Variant 1186 1187 11 8 1 Q Nominal 28 mm thickness 1 mm 8 mm 18 mm Formaldehyde content 5.7 6.9 2.3 [mg/loog] limit acc. EN 120 <8.0 PCP n.d. (mg/kg] ChemVerbotsV <5.0 - IOS-MAT-0010 3.0 Lindane n.d. n.. - [mg/kg] RAL-GZ 430 <0.5 IOS-MAT-0010 1.0 Formalde yde release - X - - <0.2 <0.2 < 0.2 [mg/m2 h] El limit acc. EN 717-2 <3.5 Migration of aluminium 71.9 Elements (Al) 70000 [mg/kg] arsenic X not detectable (As) EN 71-3 47 barium X 27.9 (Ba) EN 71-3 18750 boron 1.8 (B) 15000 cadmium X n.d. (Cd) EN 71-3 17 cobalt (Co) 130 c romiom X 0.2 (Cr) EN 71-3 460, 0.2 Cr VI copper 1.0 (Cu) 7700 mercury (H ) EN 71-3 94 anganese X 66.9 (Mn) EN 71-3 15000 mickel X 0.5 m EN 71-3 930 lead X 0.4 (Pb) EN 71-3 160 antimony X (Sb) EN 71-3 560 selenium X (Se) EN 71-3 460 tin X 0.2 (Sn) EN 71-3 180000, 12 Strontium X 6.7 (Sr) EN 71-3 56000 zinc X 4.8 JZn] EN 71-3 46000

Page 4 of 5 of Surveillance report 01-2016, Order-No. 2306 020, MDF El, Chemical testing 3 Findings 3.1 Findings of t e inspection of the manufacturing site The laboratory facilities and equipment are available and in proper condition. The inspection of the documentation of internal control testing resulted in no complaints regarding the tested Chemical properties. 3.2 Evaluation of the test results In accordance with the Che ical prohibition regulation (ChemVerbotsV) 1 (3) in connection with the federal health sheet (10/91) (pages 488-489) about test methods for wood based materials for single values of an uncoated fibre boards a Perforator value of 8.0 mg HCHO/100 g atro board may not be exceeded. The half yearly average value is 7.0 mg HCHO/100 g atro board. The values are valid for a moisture content of 6.5 %. Furthermore the limiting value for Pentachlorphenol is 5 mg/kg according to the ChemVerbotsV 1 (15). According to EN 13986, S. 27, Pkt. 5.18 the product has to be indicated at a content of PCP > 5 ppm. In accordance with the Chemical prohibition regulation (ChemVerbotsV) 1 (3) in connection with the federal health sheet (10/91) (pages 487-489) about "test methods for wood based materials" for coated wood-based materials the limit value is a gas analysis value of 3.5 mg HCHO/hm2. According to EN 71-3 the following limits of the heavy metals aluminium (70000 mg/kg), arsenic (47 mg/kg), barium (18750 mg/kg), boron (15000 mg/kg), cadmium (17 mg/kg), cobalt (130 mg/kg), chromium (460 mg/kg, 0.2 Cr VI), copper (7700 mg/kg), mercury (94 mg/kg), manganese (15000 mg/kg), nickel (930 mg/ g), lead (160 mg/kg), antimony (560 mg/kg), selenium (460 mg/kg), tin (180000 mg/kg, 12 mg/kg), Strontium (56000 mg/kg), zinc (46000 mg/kg) fixed. The formaldehyde content of the tested MDF for internal use as a non-structural component in dry conditions according to EN 622-5 is in the ränge from 2.3 to 6.9 mg HCHO/100 g atro board (B-value). The value of the formaldehyde release of the tested MDF for internal use as a non-structural component in dry conditions according to EN 622-5 is < 0.2 mg HCHO/hm2. The tested MDF for internal use as a non-structural component in dry conditions meet the requirements on the material characteristic value of wood based materials regarding formaldehyde and fulfil the formaldehyde dass El according to EN 13986, annex B, table Bl. The tested melamine faced MDF for internal use as a non-structural component in dry conditions meet the requirements on the material characteristic value of wood based materials regarding formaldehyde and fulfil the formaldehyde dass El according to E 13986, annex B, table Bl. The tested fibre boards / type MDF meet the requirements of the limiting and material characteristic value regarding PCP. The fibre boards / type MDF have not to be indicated according to EN 13986 regarding the PCP content. The tested MDF for internal use as a non-structural component in dry conditions correspond to the requirements of the EN 71-3. 4 Obligations 4.1 Compietion of the obligations from the previous surveillance Not applicable 4.2 New obligat ons Obligations were not detected.

Page 5 of 5 of Surveillance report 01-2016, Order-No. 2306 020, MDF El, Chemical testing 5 Summary of the evaluation of the surveillance T e inspection of the manufacturing site resulted in no complaints. The tested MDF for internal use as a non-structural component in dry conditions meet the requirements on the material characteristic value of wood based materials regarding formaldehyde and PCP. The tested melamine faced MDF for internal use as a non-structural component in dry conditions meet the requirements on the material characteristic value of wood based materials regarding formaldehyde and EN 71-3. The products and the FPC meet the requirements of supervision contract GP-07-04-02, Reg.-No.: 2306020, including respective Supplements. The next external monitoring should be scheduled for (2nd half of 2016). Dipl.-lng.(BA) Mäbert Engineer in Charge 6 Assessment and certification ecision The Statements made in this report's findings, and thus the certification made under this voluntary monitoring, are hereby confirmed. Dr.-Ing. Rico Emmier Product certification body