RE, RED. Electronically Controlled Inverter Driven Circulation Pump. Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS

Similar documents
Japanese Technology since Ego Circulators. Databook

TECHNICAL DATA. ErP Ready NewMotorTechnolgy. Electronically controlled high-efficiency pumps for heating, air conditioning, cooling and sanitary water

4 Specification Magneta Smedegaard twin pumps

3 Specification Magneta Smedegaard

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

Data sheet: Wilo-Stratos PICO 25/1-6

Data sheet: Wilo-Stratos PICO 25/

Data sheet: Wilo-Yonos PICO 25/

Series description: Wilo-Stratos ECO-STG

Data sheet: Wilo-Yonos MAXO 40/0,5-16

Data sheet: Wilo-Stratos-Z 25/1-8

real quality made in italy circulation pumps

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

General catalogue incl. replacement lists

Pump Stations for Heating Circuits

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

EVOPLUS / EVOPLUS SAN

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

Data sheet: Wilo-Stratos-D 32/1-8

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

Data sheet: Wilo-Stratos-D 50/1-12

Ego HIGH EFFICIENCY ELECTRONIC CIRCULATORS. 50 Hz

TPED /4-S-A-F-A-BAQE 3X400 50HZ

Lenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump

Series description: Wilo-Stratos

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

Lowara Ecocirc Vario (EV)

TP /2-A-F-A-BAQE 400D 50HZ

TPE /4-A-F-A-BAQE 3X400 50HZ

TPE S-A-F-A-BUBE

CELMA Guide for the application of the Commission Regulation (EC) No. 245/2009 on Tertiary lighting sector products

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

Series description: Wilo-TOP-S

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

TP /4-A-F-A-BUBE 400Y 50HZ

Ego HIGH PERFORMANCE ELECTRONIC CIRCULATORS

Company name: Created by: Phone:

COMMISSION REGULATION (EC)

ON/OFF zone valves AMZ 112, AMZ 113

TPE N-A-F-A-GQQE

Delta HE 35-XX, 55-XX

MAGNA F 220 1x230V PN6/10

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

TPE N-A-F-A-GQQE

TPE /2-S-A-F-A-BAQE 3X400 50HZ

TP /2-A-F-A-BUBE 1X230 50HZ

Compact Static Heat Meter of High-Tech Composite

Superstatic 749. Fluidic Oscillation Compact Heat Meter

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

TP 40-30/4-A-F-A-BUBE 400Y 50HZ

GENERAL INFORMATION THE BUSINESS STRATEGY IS CONCENTRATED ON: THE PRODUCT RANGE CONTAINS PUMPS FOR:

EVOTRON SAN WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA

4-Way Mixing Panel Submittal - Page 1 of 6

High efficiency pumps

SEMA Side channel pumps PN 25 (40) Glandless because of magnetic drive

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

Heating, air-conditioning, cooling

Hydro MPC-E 3 CRIE5-9 U1 A-A-A-GH GNL

SCX-DCX SXM-DXM. SINGLE AND TWIN-HEAD CIRCULATORS Heating and air conditioning Light commercial range 2 Pole - 50 Hz 230 V OPERATING LIMITS

Backflushing Filter AutoFilt RF3

Planning is simple: with Calio circulators for commercial buildings

EV RANGE MULTI-SPEED GLANDLESS CIRCULATORS

Series description: Wilo-TOP-STGD

High-efficiency Circulator Pump. Installation/Operating Manual Magneta Smedegaard

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

4 submersible pumps powered by renewable energy sources

Fluidic Oscillation Compact Heat Meter

ON/OFF zone valves AMZ 112, AMZ 113

TP /2-A-F-A-BQQE 400D 50HZ

MAGNA x230V PN10

Pressure independent balancing and control valve

ELECTRONIC CIRCULATORS FOR HEATING AND COOLING SYSTEMS

High-efficiency Circulator Pump. HEP Optimo L+ Installation/Operating Manual

Side channel pump PN 40 SRZ. self-priming, according to DIN EN 734. Technical description

4 variable speed submersible pumps

3-port valves vxf42..

In-Line Dry Rotor Circulating Pumps. EIL R Series EIL- FK Series

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Compact System NRGS 11-2 NRGS Original Installation Instructions English

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

TPE S-A-F-I-BQQE

2- and 3-port valves with flanged connections, PN 16

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

TPE N-A-F-I-BUBE

NBE40-125/139 AS-F2-A-BAQE

Side channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

COMPONENTS FOR SOLAR THERMAL SYSTEMS

VERTICAL IN-LINE PUMP

MAGNA3 D F 280 1x230V PN16

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

LK Manifold Shunt VS2

SCX-A. Application. Specification

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Jorge Álvarez, PM Solar, Abril 15 th - Santiago. ABB Solar Central lnverters (PMGD)

Transcription:

, RED Electronically Controlled Inverter Driven Circulation Pump Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS Directive of the European Parliament COMMISSION REGULATION (EC) No. 641/2009 and 622/2012 Eco-design Directive of Energy Using Products (ErP Directive - Energy related Products). The European Union wants to improve the design of equipment that consume significant energy e.g. (televisions, refrigerators, washing machines, boilers, pumps, and motors etc.). To improve eco design providing environmental sustainability, reducing negative environmental impact as the consequence of production, use and disposal of products. The objective of the Directive is to force manufacturers and importers to produce and distribute products with high energy efficiency, and carbon output. The criteria for eco-design will be an integral part of the declaration of conformity (CE), which is a necessary requirement/mark for products being sold in the EU. This Regulation shall not apply to: a) drinking water circulators b) circulators integrated in products and placed on the market not later than 1 January 2020 as replacement for identical circulators integrated in products and placed on the market no later than 1 August 2015. The replacement product or its packaging must clearly indicate the product(s) for which it is intended. This Regulation shall apply in accordance with the following timetable: 1. from 1 January 2013, glandless standalone circulators shall meet the efficiency level (EEI) less than 0.27, with the exception of those specifically designed for primary circuits of thermal solar systems and of heat pumps. 2. from 1 August 2015, glandless standalone circulators and glandless circulators integrated in products shall meet the efficiency level (EEI) less than 0.23. This Regulation shall apply to: Stand-alone* or integrated** circulators with the motor immersed in the pumped medium, with hydraulic power from 1 up to 2500 W, designed for use in heating systems or in secondary circuits of cooling distribution systems. * Stand alone circulators are commonly available on the market. ** circulators integrated in products are component of a device, such as boilers, heat pumps, etc. 11

RE 25-80/180 can adapt to current needs of the system with proportional or constant pressure regulation. : After selecting level pump recognizes the lowest resistance of the system and automatically adjusts its own strain. : After selection pump works in three different speeds. Energy savings Easy handling and installation Robust and compact construction for long-lasting Automatic venting Low noise operation Single body, which allows a variety of mounting positions Flow Q up to 4,5 m 3 /h Pressure H up to 8 m Power 7-75 Watt Nominal pressure 10 Bar Permissible mediums of water with over 20% of glycol. Medium temperature from +5 C to +95 C with max. surroundings 0,05 bar < 75 C temperature of medium 0,28 bar < 90 C temperature of medium The energy index EEI <= 0,24 - Part 2 Control Δp or constant speed Insulation Class: F 12

RE 25-120/180 Night mode Energy savings Easy handling and installation Plug & Play Robust and compact construction for long-lasting Automatic venting Low noise operation Flow Q up to 11 m 3 /h Pressure H up to 12 m Power 10-180 Watt Nominal pressure 10 Bar Permissible mediums of water with over 20 % of glycol. Medium temperature from +2 C to +110 C with max. surroundings 0,05 bar < 75 C temperature of medium 0,28 bar < 90 C temperature of medium The energy index EEI <= 0,21 - Part 2 Insulation Class: F 13

RE 40-120/250 Night mode Energy savings Easy handling and installation Plug & Play Robust and compact construction for long-lasting Automatic venting Low noise operation Flow Q up to 23 m 3 /h Pressure H up to 12 m Power 25-480 Watt Nominal pressure 6/10 Bar Permissible mediums: of water with over 20% of glycol. Medium temperature from +2 C to +110 C with max. surroundings 0,05 bar < 75 C temperature of medium 0,28 bar < 90 C temperature of medium The energy index EEI <= 0,21 - Part 2 Insulation Class: F 14

RE 40-180/250 D option, twin pump Easy operation and simple installation Communication - Ethernet connection - 1 relay output - 2 digital inputs Flow Q up to 31 m 3 /h Pressure H up to 18 m Power 20-800 Watt Nominal pressure 6/10 Bar Permissible mediums of water with over 20 % of glycol. Medium temperature from -10 C to +110 C with max. surroundings 0,5 bar < 50 C temperature of medium 0,8 bar < 80 C temperature of medium 1,4 bar < 110 C temperature of medium The energy index EEI <= 0,27 - Part 2 Methods of control - Current Control (limit current) - Power Control (limit power) - Constant pressure control (Δp-c) - Dp prop (Δp-v) - Option settings QH curve at fixed speeds - Constant speed Insulation Class: H 15

RE 50-120/280 permanent magnets and integrated electronic which the pumps can adapt to current needs of the system. D option, twin pump It is used for circulation of water or a mixture of water/glycol in heating systems, air conditioning systems and circulation systems. Easy operation and simple installation Communication - Ethernet connection - 1 relay output - 2 digital inputs Flow Q up to 39 m 3 /h Pressure H up to 13 m Power 26-800 Watt Nominal pressure 6/10 Bar Permissible mediums: of water with over 20% of glycol. Medium temperature from -10 C to +110 C with max. surroundings 0,5 bar < 50 C temperature of medium 0,8 bar < 80 C temperature of medium 1,4 bar < 110 C temperature of medium The energy index EEI <= 0,26 - Part 2 Methods of control - Current Control (limit current) - Power Control (limit power) - Constant pressure control (Δp-c) - Dp prop (Δp-v) - Option settings QH curve at fixed speeds - Constant speed Insulation Class: H 16

RE 50-180/280 D option, twin pump Easy operation and simple installation Communication - Ethernet connection - 1 relay output - 2 digital inputs Flow Q up to 45 m 3 /h Pressure H up to 17 m Power 20-1000 Watt Nominal pressure 6/10 Bar Permissible mediums of water with over 20% of glycol. Medium temperature from -10 C to +110 C with max. surroundings 0,5 bar < 50 C temperature of medium 0,8 bar < 80 C temperature of medium 1,4 bar < 110 C temperature of medium The energy index EEI <= 0,26 - Part 2 Methods of control - Current Control (limit current) - Power Control (limit power) - Constant pressure control (Δp-c) - Dp prop (Δp-v) - Option settings QH curve at fixed speeds - Constant speed Insulation Class: H 17

Dimensions Model Diameter DN mm PN kg RE 25-80/180 1 25 180 10 BAR 2,4 RE 25-120/180 1 25 180 10 BAR 3,2 RE 40-120/250-40 250 6/10 BAR 9 RE 40-180/250-40 250 6/10 BAR 56 RE 50-120/280-50 280 6/10 BAR 30 RE 50-180/280-50 280 6/10 BAR 30 Model h DN D2 b b1 b2 b4 l a RE 25-80/180 180 25 1-80 48-108 - RE 25-120/180 180 25 6/4 117 - - - 190 53 RE 40-120/250 250 40-146 - - - 260 65 RE 40-180/250 250 40 - - 198 - - 355 65 RE 50-120/280 280 50 - - 200 - - 355 70 RE 50-180/280 280 50 - - 200 - - 355 70 Pump Component Housing Material Cast Iron Impeller Polyamid (For RE 25-80/180) PES (For RE 25-120/180,RE 40-120/250) Stainless Steel (For 40-180/250, RE 50-120/280, RE 50-180/280) Shaft Ceramics (For RE 25-80/180) Stainless Steel (For 25-120/180, RE 40-120/250, RE 40-180/250, RE 50-120/280, RE 50-180/280) Bearings Ceramics (For RE 25-80/180) Graphite (For 25-120/180, RE 40-120/250, RE 40-180/250, RE 50-120/280, RE 50-180/280) Ventricular Wall for RE 25-80/180, RE 25-120/180, RE 40-120/250 Stainless Steel Seperating Bush for RE 40-180/250, RE 50-120/280, RE 50-180/280 Rotor Can Stainless Steel 18

D 32-100/180-TWIN RED Electronically Controlled, Inverter Driven, Twin Execution Circulation Pump Twin pump Night Mode Energy savings Easy handling and installation Plug & Play Robust and compact construction for long-lasting Automatic venting Low noise operation Flow Q up to 11 m 3 /h Pressure H up to 10 m Power 10-180 Watt Nominal pressure 10 Bar Permissible mediums: of water with over 20 % of glycol. Medium temperature from +2 C to +110 C with max. surroundings 0,05 bar < 75 C temperature of medium 0,28 bar < 90 C temperature of medium The energy index EEI <= 0,21 - Part 2 Insulation Class: H 19

D 40-180/250-TWIN RED Electronically Controlled, Inverter Driven, Twin Execution Circulation Pump Twin pump Easy operation and simple installation Communication - Ethernet connection - 1 relay output - 2 digital inputs Flow Q up to 31 m 3 /h Pressure H up to 18 m Power 20-800 Watt Nominal pressure 6/10 Bar Permissible mediums of water with over 20% of glycol. Medium temperature from -10 C to +110 C with max. surroundings 0,5 bar < 50 C temperature of medium 0,8 bar < 80 C temperature of medium 1,4 bar < 110 C temperature of medium The energy index EEI <= 0,27 - Part 2 Methods of control - Current Control (limit current) - Power Control (limit power) - Constant pressure control (Δp-c) - Dp prop (Δp-v) - Option settings QH curve at fixed speeds - Constant speed Insulation Class: H 20

D 50-180/280-TWIN RED Electronically Controlled, Inverter Driven, Twin Execution Circulation Pump Twin pump Easy operation and simple installation Communication - Ethernet connection - 1 relay output - 2 digital inputs Flow Q up to 45 m 3 /h Pressure H up to 17 m Power 20-1000 Watt Nominal pressure 6/10 Bar Permissible mediums of water with over 20% of glycol. Medium temperature from -10 C to +110 C with max. surroundings 0,5 bar < 50 C temperature of medium 0,8 bar < 80 C temperature of medium 1,4 bar < 110 C temperature of medium The energy index EEI <= 0,26 - Part 2 Methods of control - Current Control (limit current) - Power Control (limit power) - Constant pressure control (Δp-c) - Dp prop (Δp-v) - Option settings QH curve at fixed speeds - Constant speed Insulation Class: H 21

D Electronically Controlled, Inverter Driven, Twin Execution Circulation Pump Dimensions Model Diameter DN mm PN kg RED 32-100/180 1¼" 32 180 10 BAR 8,2 RED 40-180/250 40 250 6/10 BAR 56 RED 50-180/280 50 280 6/10 BAR 59 Model h DN D2 b b1 b2 b4 l a RED 32-100/180 180 32 2" 297 190 56 RED 40-180/250 250 40 403 355 65 RED 50-180/280 280 50 403 355 70 Pump Component Housing Shaft Bearings Ventricular Wall for For RED 32-100/180) Seperating Bush for RED 40-180/250, RED 50-180/280 Rotor Can Material Cast Iron PES (For RED 32-100/180) Stainless Steel (RED 40-180/250, RED 50-180/280) Stainless Steel Graphite Stainless Steel Stainless Steel 22