Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Similar documents
Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

Standby Amper VOLTAGE

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

Standby Amper VOLTAGE

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

MITSUBISHI STAMFORD P CM control system. This generator set is manufactured in facilities certified to ISO 9001.

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

APD-NG400. NG Standby Power

APD-ULJ250. Standby Power

640 KW / 800 KVA POWERED by

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

16 KW / 20 KVA POWERED by

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

1000 KW / 1250 KVA POWERED by

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

80 KW / 100 KVA POWERED by

700 KVA / 550 KW POWERED by

28 KW / 28 KVA POWERED by

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

1800 KW / 2250 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

55 KW / 70 KVA POWERED by

45 KW / 55 KVA POWERED by

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

Rental Power 4BTAA3.3 series engine

Rental Power QSL9 series engine

18 KW / 18 KVA POWERED by

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

2000 KW / 2500 KVA POWERED by

Rental Power Kubota V2403 series engine

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Rental Power QSB7 series engine

Diesel Generator Set S3.8 Series Engine

600 KW / 750 KVA POWERED by

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

DIESEL GENERATOR SET MTU 4R0113 DS80

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

130 KW / 165 KVA POWERED by

30 KW / 40 KVA POWERED by

Diesel generator set QSL9 series engine

Technical specification

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

500 KW / 625 KVA POWERED by

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

1 / Genset general description

DIESEL GENERATOR SET MTU 12V1600 DS660

Expert Design...Trusted Power

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

64 KW / 80 KVA POWERED by

DIESEL GENERATOR SET MTU 10V1600 DS500

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

1 / Genset general description

DIESEL GENERATOR SET DG00660D5

204 KW / 254 KVA POWERED by

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Model NA 2 L

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Rating Definitions and Conditions

Transcription:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 2000/14/EC 3 Phase Ratings, 50 Hz, PF 0,8 Standby Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 400/230 2100,00 1680,00 1875,00 1500,00 2709,00 Standby Rating (ESP): Prime Rating (PRP): Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed. Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046. STANDARD SPECIFICATIONS Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack and cables Engine coolant heater Base frame design incorporates an integral fuel tank and anti-vibration isolators Flexible fuel connection hoses Single bearing, class H alternator Industrial exhaust silencer and steel bellows supplied separately(for open sets) Static battery charger Manual for application and installation Generators Sets voltage and frequency regulation comply with ISO 8528-5 Generators Sets can take 100% load at one step according to NFPA110 OPTIONAL EQUIPMENTS ENGINE - Remote Radiator Cooling - Fuel-Water Seperator Filter - Oil heater - Anti-Condensation Heater - Main line circuit breaker OTHER ACCESSORIES - Automatic or manual fuel filling system - Residential silencer - Enclosure: weater protective or sound attenuated - Duct adapter ( on radiator) - Inlet and outlet motorised louvers - Inlet and outlet acoustic baffles - Tool kit for maintenance - 1500/3000 hours maintenance kit - Supplied with oil and coolant - 30 C - Main Fuel Tank CONTROL SYSTEM - Automatic synchronising and power control system ( multi gen-set Parallel ) - Paralel system with mains. - Transition synchronization with mains - Remote relay output - Alarm output relays - Remote communication with modem - Earth fault, single set - Charge Ammeter TRANSFER SWITCH - Three or four pole contactor - Three or four pole motor operated circuit breaker 1

DIESEL ENGINE SPECIFICATIONS Manufacturer Model No. of Cylinders and Build Aspiration and Cooling Maximum Standby Power Mitsubishi S16R-PTA2 Total Displacement L 65,370 16-cylinder, V - Type Turbo Charged and After Cooled 1500 rpm 1790,00 kw [2399,00HP] Bore and Stroke mm 170x180 Compression Ratio 13,5:1 Rated Speed (rpm) rpm 1500 Governor Electronic Oil Capacity L 230,00 Coolant Capacity L 445,00 Intake Air Flow m³ /min. 143,00 Radiator Cooling Air m³ /min. 2040,00 Exhaust Gas Temperature C 379,00 Start System Fuel Consumption 24 V d.c. Load %100 L/h 406,10 ALTERNATOR SPECIFICATIONS Model ECO46-1L/4 Frequency Hz 50 Power kva 2100,00 Design Brushless, 4 poles Cos Phi 0,80 Phase 3 Voltage V 400/230 Insulation Class H Excitation System Electronic ( AVR ) DIEMENSIONS AND WEIGHT Open Type Dry Weight Lenght Width Height Tank Capacity kg. mm. mm. mm. L APD 2100 M 14850,00 5200,00 2500,00 2900,00 2000,00 Canopy Dry Weight Lenght Width Height Tank Capacity kg. mm. mm. mm. L AK 99 20100 9000 2800 3478/4452 2200 2

P 732 control system - Control System 1 2 3 4 5 6 7 Menu navigation buttons Close mains button Main Status and instrumentation display Alarm LED's Close generator button Status LED's Operation selecting buttons Devices DSE, model 7320 Auto Mains Failure control module Static battery charger Emergency stop push button and fuses for control circuits Construction and Finish Comonents installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface Polyester composite powder topcoat forms high gloss and extremely durable finish Lockable hinged panel door provides for easy component access Installation Control panel is mounted generating set baseframe on robust steel stand or power module. Located at side of generating set with properly panel visibility. Generating Set Control Unit The DSE 7320 conrol module is a standard addition to our generator sets from 220 kva upwards and it has been designed to start and stop diesel andgas generating sets that include electronic and non electronic engines. The DSE 7320 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable for controlling a standby generating set in conjunction with an automatic transfer switch.the DSE7320 also indicates operational status and fault conditions, automatically shutting down the generating set and indicating faults by means of its LCD display on the front panel. Standard Specifications Microprocessor controlled 132 x 64 pixel LCD display makes information easy to read Front panel programming and also via PC software Soft touch membrane keypad and five key menu navigation Remote communications via RS232, RS485 and ethernet and SMS messaging Event logging (50) showing date and time Multiple date and time engine exercise mode and maintenance scheduler Engine block heater control. Controls; stop, manuel, auto, test, start, mute lamb test/transfer to generator, transfer to mains, menu navigation. 3

Instruments ENGINE Engine speed Oil pressure Coolant temperature Run time Battery volts Engine maintenance due GENERATOR Voltage (L-L, L-N) Current (L1-L2-L3) Frequency Earth current kw Pf kvar kwh, kvah, kvarh Phase sequence MAINS Voltage (L-L, L-N) Frequency Options High oil temperature shut down Low fuel level shut down Low fuel level alarm High fuel level alarm EXPANSION MODULES Editional LED module (2548) Expension relay module (2157) Expansion input module (2130) Static Battery Charger Protection Circuits WARNING Charge failure Battery under voltage Fail to stop Low fuel level (opt.) kw over load Negative phase sequence Loss of speed signal PRE-ALARMS Low oil pressure High engine temperature Low engine temperature Over /Under speed frequency voltage ECU warning SHUT DOWNS Fail to start Emergency stop Low oil pressure High engine temperature Low coolant level Over /Under speed frequency voltage Oil pressure sensor open Phase rotation ELECTRICAL TRIP Earth fault kw over load Generator over current Negative phase sequence Standards Elecrical Safety / EMC compatibility BS EN 60950 Electrical business equipment BS EN 61000-6-2 EMC immunity standard BS EN 61000-6-4 EMC emission standard Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficincy. Battery charger models' output V-I characteristic is very close to square 2405 has fully output shot circuit protection and ıt can be used as a current source. 2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear alternatives. The charger is fitted with a protection diode across the output. Charge fail output is available. Connect charge fail relay coil between positive output and CF output. Input: 196-264V. Output: 27,6V 5A or 13,8V 5A. 4

AK 99 - Canopy Introduction 1 Steel structure made from steel sheet and steel profiles. 2 canopy and panels made from powder coated sheet steel. 3 Emergency stop push button. 4 Control panel is mounted on the baseframe. Located at the back of the 5 generator set 6 Cables out locations are back of the canopy. 7 Corrosion-resistant locks and hinges. 8 oil could be drained via valve and a hose 9 Exhaust system on the canopy. 10 special large access doors for easy maintanance 11 the cap on the canopy provides easy accsess to radiator cap. 12 Lifting points similar to ISO container, located on each top corner of 13 c th a e nopy. 14 sound proofing materials Sound-attenuated and weather protective enclosures for generating sets from us, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability. Standard Specifications Compact footprint, low profile design. Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as one package Body made from steel components treated with polyester powder coating Fire retardant foam insulation Easy access to all service points Exhaust system inside canopy Large doors on each side Control panel viewing window in a lockable access door Emergency stop push button mounted on enclosure exterior Cooling fan and battery charging alternator fully guarded Fuel fill and battery can only be reached via lockable access doors. Lifting points on the top of canopy and base frame Customer options available to meet your applications needs. Makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been aproved by the notified body Szutest Width mm. 2800 Lenght mm. 9000 Height mm. 3478/4452 Fuel Tank Capacity L 2200 5