GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

Similar documents
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

Standby Amper VOLTAGE

Standby Amper VOLTAGE

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

MITSUBISHI STAMFORD P CM control system. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Standby Amper VOLTAGE

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

Standby Amper VOLTAGE

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

APD-ULJ250. Standby Power

640 KW / 800 KVA POWERED by

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

APD-NG400. NG Standby Power

700 KVA / 550 KW POWERED by

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

16 KW / 20 KVA POWERED by

1000 KW / 1250 KVA POWERED by

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

80 KW / 100 KVA POWERED by

28 KW / 28 KVA POWERED by

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

1800 KW / 2250 KVA POWERED by

45 KW / 55 KVA POWERED by

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

55 KW / 70 KVA POWERED by

130 KW / 165 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

18 KW / 18 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

2000 KW / 2500 KVA POWERED by

Rental Power 4BTAA3.3 series engine

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

Rental Power QSB7 series engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Rental Power QSL9 series engine

Rental Power Kubota V2403 series engine

600 KW / 750 KVA POWERED by

Diesel Generator Set S3.8 Series Engine

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

30 KW / 40 KVA POWERED by

Expert Design...Trusted Power

GMR - 67P 67P 09/05/2016 GMR - 067P

204 KW / 254 KVA POWERED by

Model NA 2 L

500 KW / 625 KVA POWERED by

64 KW / 80 KVA POWERED by

UK MANUFACTURED GENERATORS PS9P PS20P PERKINS 400 SERIES TECHNICAL DATA SHEET

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

Modular Acoustic Enclosures

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

Rating Definitions and Conditions

UNIVERSAL PRODUCT RANGE. Performance I Durability I Serviceability

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

DIESEL GENERATOR SET MTU 18V2000 DS1400

Model MP150 W W

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

DIESEL GENERATOR SET MTU 16V2000 DS KVA

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

DIESEL GENERATOR SET MTU 16V2000 DS1000

Rating Definitions and Conditions

Diesel generator set QSL9 series engine

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

Rating Definitions and Conditions

Transcription:

970kW AGG 1000 Engine : Alternator : Control System : GUASCOR LEROY SOMER P 732 control system This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed product is tested EU noise legislation 2000/1/EC Rated Power, 3 Phase, 50 Hz, PF 0,8 Rating (CRP) Rating (CRP) Voltage kva kw 00/230 1210 970.00 Amp 1750.00 Rating (CRP): Applicable for supplying power to varying electrical load for unlimited hours. CRP is in accordance with ISO 8528. No overload capability. - With Remote Radiator ALTERNATOR Optional Equipments ENGINE - Low Coolant level alarm - Oil heater VISE ACCESSORIES - Manual oil drain pump - Electrical oil drain pump - Enclosure: weater protective or sound attenuated - Duct adapter ( on radiator) - Inlet and outlet motorised louvers - Tool kit for maintenance - 1.500/3.000/10.000 hours maintenance kit - Four Pole Contactor 1 - Anti-Condensation heater - Over sized alternator - Single Phase ( lead) - Main line circuit breaker CONTROL SYSTEM - Automatic synchronising and power control system ( multi gen-set Parallel ) - Paralel system with mains. - Remote annunciator panel - Alarm output relays - Remote communication with modem - Earth fault, single set - Charging ammeter Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories witout prior notice. AKS 29072010

±5%(depending on the gas quality) AGG 1000 970kW Natural Gas Powered Engine Specification Manufacturer Guascor Model SFGM 560 Aspiration and Cooling Turbo Charged and intercooler Maximum Power 1500 d/dk 970.0kW[HP] Total Displacement and Number of Cylinder dm³ 2,0-16 Bore and Stroke Bore and Stroke 160 x 175 Compression Ratio 12 : 1 Rated Speed rpm 1500 Governor Electronic Fuel Consumption m³/h 256 ±5% (depending on the gas quality) Gas Pressure mbar 50-20 Oil Capacity dm³ 232 Water Capacity L 260 main circuit Lube oil Consumption g / kwh 0,2 Exhaust Backpressure mbar 5 Exhaust Gas Flow m³ /dk. 2868 Exhaust Gas Tempratures C 500 Electricity System 2 Alternator Specification Manufacturer Leroy Somer Model LSA 50.2 M6 Power kw 1000 Design Brushless, -pole Cos fi 1 Phase 3 Voltage V 00/230 A 180 Insulation Class H Stator 2 / 3 steps Excitation System Electronic ( AVR ) Diemensions and Weight Open Type Sound Attenuated Type SCH 0 Dry Weight kg. 9850 750 2500 2560 Dry Weight kg. 15500 12200 20 2800 2

AGG 1000 970kW P 732 control system - Control System 1 2 3 5 6 Menu navigation buttons Close mains button Main Status and instrumentation display Alarm LED's Close generator button Status LED's Operation selecting buttons Devices DSE, model 7320 Auto Mains Failure control module Static battery charger 5A, 220/20 volt Emergency stop push button and fuses for control circuits Structure And Paint Comonents installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface Polyester composite powder topcoat forms high gloss and extremely durable finish Lockable hinged panel door provides for easy component access Montage Control panel is mounted generating set baseframe on robust steel stand or power module. Located at side of generating set with properly panel visibility. Generator Control Unit Microprocessor controlled 132 x 6 pixel LCD display makes information easy to read Front panel programming and also via PC software Soft touch membrane keypad and five key menu navigation Remote communications via RS232, RS85 and ethernet and SMS messaging Event logging (50) showing date and time Multiple date and time engine exercise mode and maintenance scheduler 3

AGG 1000 970kW Indicator ENGINE Engine speed Oil pressure Coolant temperature Run time Battery volts Engine maintenance due GENERATOR Voltage (L-L, L-N) Current (L1-L2-L3) Frequency Earth current kw Pf kvar kwh, kvah, kvarh Phase sequence MAINS Voltage (L-L, L-N) Frequency Optional Properties High oil temperature shut down Low fuel level shut down Low fuel level alarm High fuel level alarm EXPANSION MODULES Editional LED module (258) Expension relay module (2157) Expansion input module (2130) Protection WARNING Charge failure Battery under voltage Fail to stop Low fuel level (opt.) kw over load Negative phase sequence PRE-ALARMS Low oil pressure High engine temperature Low engine temperature Over /Under speed frequency voltage ECU warning SHUT DOWNS Fail to start Emergency stop Low oil pressure High engine temperature Low coolant level Over /Under speed frequency voltage Oil pressure sensor open Phase rotation ELECTRICAL TRIP Earth fault kw over load Generator over current Negative phase sequence Standards Elecrical Safety / EMC compatibility BS EN 60950 Electrical business equipment BS EN 61000-6-2 EMC immunity standard BS EN 61000-6- EMC emission standard Electronic Charge Equipment

970kW AGG 1000 SCH 0 1 2 3 5 6 7 8 9 10 Steel structures Emergency stop push button Control panel is right side of the set. Corrosion-resistant locks and hinges Sump drains valves Exhaust system in the canopy Lockable, large doors o each side Sound proof foam metarial Base frame -tank Lifting Points Introduction Sound attenuated and Weather-protective Enclosures Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies (300 1100kVA) provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability. Canopy Model Standart Specification Compact footprint, low profile design. Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as one package Body made from steel components treated with polyester powder coating Fire retardant foam insulation Easy access to all service points Exhaust system inside canopy Large doors on each side Control panel viewing window in a lockable access door Emergency stop push button mounted on enclosure exterior Cooling fan and battery charging alternator fully guarded Fuel fill and battery can only be reached via lockable access doors. Lifting points on the top of canopy and base frame Customer options available to meet your applications needs. Aksa makes its generating sets' noise level tests in accordance with directive 2000/1/EC validation of the noise level test has been aproved by the notified body Szutest 12200 20 2800 5

AGG 1160 1160kW ISO 8528 SZUTEST This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed product is tested EU noise legislation 2000/1/EC Rated Power, 3 Phase, 50 Hz, PF 0,8 Rating (CRP) Rating (CRP) Voltage kva kw Amp 00/230 150 1160.00 2093.00 Rating (CRP): Applicable for supplying power to varying electrical load for unlimited hours. CRP is in accordance with ISO 8528. No overload capability. - With Remote Radiator Optional Equipments ENGINE - Low Coolant level alarm - Oil heater VISE ACCESSORIES - Manual oil drain pump - Electrical oil drain pump - Enclosure: weater protective or sound attenuated - Duct adapter ( on radiator) - Inlet and outlet motorised louvers - Tool kit for maintenance - 1.500/3.000/10.000 hours maintenance kit - Four Pole Contactor ALTERNATOR - Anti-Condensation heater - Over sized alternator - Single Phase ( lead) - Main line circuit breaker CONTROL SYSTEM - Automatic synchronising and power control system ( multi gen-set Parallel ) - Paralel system with mains. - Remote annunciator panel - Alarm output relays - Remote communication with modem - Earth fault, single set - Charging ammeter 1

AGG 1160 1160kW Natural Gas Powered Engine Specification Manufacturer Guascor Model HGM 560 Aspiration and Cooling Turbo Charged and intercooler Maximum Power 1500 d/dk 1160.0kW Total Displacement and Number of Cylinder dm³ 56,3-16 Bore and Stroke Bore and Stroke 160 x 175 Compression Ratio 12 : 1 Rated Speed rpm 1500 Governor Electronic Fuel Consumption m³/h 256 ±5% (depending on the gas quality) Gas Pressure mbar 50-20 Oil Capacity dm³ 00 Water Capacity L 295 main circuit Lube oil Consumption g / kwh 0,2 Exhaust Backpressure mbar 5 Exhaust Gas Flow kg/h 630 Exhaust Gas Tempratures C 17 Electricity System 2 Alternator Specification Manufacturer Leroy Somer Model LSA 50.2 L8 Power kw 1200 Design Brushless, -pole Cos fi 1 Phase 3 Voltage V 00/230 A 2165 Insulation Class H Stator 2 / 3 steps Excitation System Electronic ( AVR ) Diemensions and Weight Open Type AGG 1160 Sound Attenuated Type SCH 0 Dry Weight kg. 11810 350 1850 2170 Dry Weight kg. 1780 12200 20 2800 2

AGG 1160 1160kW P 732 control system - Control System 1 2 3 5 7 Menu navigation buttons Close mains button Main Status and instrumentation display Alarm LED's Close generator button Status LED's Operation selecting buttons Devices DSE, model 7320 Auto Mains Failure control module Static battery charger 5A, 220/20 volt Emergency stop push button and fuses for control circuits Structure And Paint Comonents installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface Polyester composite powder topcoat forms high gloss and extremely durable finish Lockable hinged panel door provides for easy component access Montage Control panel is mounted generating set baseframe on robust steel stand or power module. Located at side of generating set with properly panel visibility. Generator Control Unit Microprocessor controlled 132 x 6 pixel LCD display makes information easy to read Front panel programming and also via PC software Soft touch membrane keypad and five key menu navigation Remote communications via RS232, RS85 and ethernet and SMS messaging Event logging (50) showing date and time Multiple date and time engine exercise mode and maintenance scheduler 3

AGG 1160 1160kW Indicator ENGINE Engine speed Oil pressure Coolant temperature Run time Battery volts Engine maintenance due GENERATOR Voltage (L-L, L-N) Current (L1-L2-L3) Frequency Earth current kw Pf kvar kwh, kvah, kvarh Phase sequence MAINS Voltage (L-L, L-N) Frequency Optional Properties High oil temperature shut down EXPANSION MODULES Editional LED module (258) Expension relay module (2157) Expansion input module (2130) Protection WARNING Charge failure Battery under voltage Fail to stop kw over load Negative phase sequence PRE-ALARMS Low oil pressure High engine temperature Low engine temperature Over /Under speed frequency voltage ECU warning SHUT DOWNS Fail to start Emergency stop Low oil pressure High engine temperature Low coolant level Over /Under speed frequency voltage Oil pressure sensor open Phase rotation ELECTRICAL TRIP Earth fault kw over load Generator over current Negative phase sequence Standards Elecrical Safety / EMC compatibility BS EN 60950 Electrical business equipment BS EN 61000-6-2 EMC immunity standard BS EN 61000-6- EMC emission standard Electronic Charge Equipment

AGG 1160 SCH 0 1160kW Introduction Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers.our sound insulated containers provide ease of access for servicing and general maintenance permitting on-site. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability. Standard Specifications Robustly constructed walk in enclosure designed provide the necessary weather protection, sound attenuation and ventilaton for the generator and switchgear. Ribbed aluminium sheet internal floor Ceilling mounted fluorescent light fittings RAL 9010 white painted finish Corner fittings to ISO 1161, providing four point lifting capability for full wet weight Personel access doors and internal panic relase button on one of door. Exhaust silencer is horizontally mounted on top of enclosure roof and available dependant on size of generators and options selected Protective grille for fan, rotating parts and hot parts Removable enclosure roof Steel ladder for roof Fuel tank complete with retention bund, contents gauge, vent and manual fuel fill point Power cable outlet on lower section Aksa makes its generating sets' noise level tests in accordance with directive 2000/1/EC validation of the noise level test has been aproved by the notified body Szutest Canopy Model SCH 0 12200 20 2800 5