Long Throw Nozzle WDA

Similar documents
Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

Ceiling diffuser 4DF

ceiling swirl diffuser DQJ

WGA Long throw nozzle grille

Swirl Diffuser Model DQF

Ceiling Swirl Diffuser DQJ

Ceiling impulse diffuser Model PIL

Ceiling diffuser 4DE

Ventilation grille Model IB-R

Nozzle Jet Diffuser Model DSA

ceiling swirl diffuser Model DQJA / DQJR

Ceiling Slot Diffuser DSC

Ventilation grille Model AL

Round duct grille Model KG-RR

Round duct diffuser DBB-RR

Compact Grille Model KG

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

Lint separator FLARE

Mechanical mixing box MBM

Ventilation Grille PA

Ceiling Slot Diffuser Model DSX

LAQ Return air diffuser

Particle Filter Box FKU

Particle Filter Box Model FKF

Ceiling induction diffuser DISA-300

Air diffuser system Model AUDIX -AW

DSC-PLASTER Slot diffuser for plasterboard ceilings

Volumetric Flow Limiter VOLKOM

Ceiling induction diffuser DISA-601

Technical documentation

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Slot diffusers, Round duct diffusers. IMP Klima

Ceiling swirl diffusers

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate

Round Duct System Model RR-Complete

Ventilation grilles for installation into walls, sills or rectangular

Round Duct System Model RR-Complete

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

DRUM SLOT DIFFUSER TYPE: RT350

volumetric flow controller Model VRA-Q Smart

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

Ventilation grilles for installation into walls, sills or rectangular

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Air Displacement Vent Units

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Fan coil unit NBS 100/150

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

WALL VENTILATION GRILLES CBP

Weather protection grille ALAS

Round Duct System Accessories RR - accessories

Catalog Swirl diffuser DAL 358

KTI Supply air valve. Product Facts. Product code example. Quick Selection

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

Fire Damper BSK-RPR. with general building supervisory approval Z

NSDZ. Swirl diffusers with adjustable air control blades

ACTIVENT System. Specifications. Product code example ACTA

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Catalog Swirl diffuser DAL 359

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

KSOM Control exhaust valve

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

SDV Vane Swirl Diffusers

NTK floor twist outlet DB-N-DN 215

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Ceiling air diffuser INDULCLIP INDUDRALL KOMBICLIP

DATASHEET PRODUCT CODE EXAMPLE:

KSOF Fire damper valve

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

CornerAir. CornerAir. Active chilled beam

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

1) Retractable nipple with centering 2) Retractable nipple with equalizer 3) Retractable nipple without centering

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Transcription:

Long Throw Nozzle WDA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de

Contents Description...3 Construction... 3 Model... 3 Accessories... 3 Models and dimensions...4 Dimensions... 4 Dimensions of accessories... 5 Technical Data... 12 Pressure loss and noise level... 12 Maximum end velocity of jet... 16 Maximum penetration... 17 Induction ratios... 19 Temperature ratios... 20 Definitions... 21 Further data... 22 Connection diagrams of electric actuators... 24 Technical data of electric actuators... 25 Legend... 27 Ordering details... 28 Specification texts... 29 05/18-2

Description A horizontal supply air pattern is often required for large, high rooms such as theatres, concert halls, production halls, etc. Long throw nozzles type WDA are particularly suitable for this application. Their low noise level allows a high blow velocity, resulting in correspondingly long throw distances. The nozzles are also well suited to vertical throws. Please note, however, that nozzles which are designed for heating mode can cause draughts in cooling mode. This can be avoided if the nozzles are designed for cooling mode. In this case, in heating mode, individual nozzles can be blanked off to achieve a higher exit velocity than that of the remaining ones, thus resulting in increased penetration. An alternative would be to design the nozzles based on maximum penetration during heating and to reduce the total air volume during ventilation, thus saving energy costs. We have also developed accessories for the nozzle in order to extend their possible uses. A swivel head allows you to move the nozzle by approx. 30 degrees in all directions. This does not affect the noise level or pressure loss. This adjustment can be done manually or electrically. The twist disks greatly reduce the penetration. In special cases, it is also possible to change the throw distances by selecting a different nozzle diameter (from the given standard nozzle diameter). For mounting in the ceiling or wall, inspection openings for the electrical connection must be provided on-site in sufficient number and size. Attention: Please note that for size 400 the connection pipe of the throw nozzles must be fitted on-site. The installation of WDA type into spiral ducts must take place free of stress. Avoid using unround or deformed spiral ducts, in order to protect the nozzle from distortion. Construction Connection pipe - Sheet steel painted to RAL 9010 (white) (WDA-F only) - Galvanised sheet steel (WDA-W and WDA-D) Nozzle part - Aluminum painted to RAL 9010 (white) (not possible for size 50) Sheet steel painted to RAL 9010 (white) (only sizes 80, 87, - 100) Mounting ring - Sheet steel painted to RAL 9010 (white) Saddle bracket - Galvanised sheet steel (WDA-...RA only) Model WDA WDA-F WDA-W WDA-D WDA-K WDA-RA WDA-W-RA Accessories - Nozzle without accessories (not available with swivel head) - for flexible duct connection - for spiral duct connection - for ceiling and wall mounting - for duct connection - for round duct connection (using saddle bracket) Not available with swivel head (not possible for size 400) - for round duct connection (using saddle bracket) Available with swivel head (not possible for size 400) Cover plate (-BR) - Sheet steel painted to RAL 9010 (white, standard) Twist disk (-DS 1/2) - Sheet steel painted to RAL 9005 (black) (sizes 63-200) Damper (-DV) - Galvanized sheet steel with integrated perforated equalising grid (for supply air only) and fixing lugs Electric actuator (-E) - only available with swivel head (sizes 63-400) - Actuator mounted externally (standard) - Actuator mounted internally (at an extra charge) (not possible for size 400) - E1, 230V AC, 3-point activation - E2, 24V AC, 0-10V (standard) - E3, 24V AC, 3-point activation Reduction piece (-RS) - Sheet steel painted to RAL 9010 (white) (only available with sizes 63-200 of model WDA-F/W) Swivel head (-SK) - Sheet steel painted to RAL 9010 (white) (sizes 31-45, 63-100) - Aluminum painted to RAL 9010 (white) (sizes 125-400) Ball impact guard (-BS) - only WDA-D / WDA-K / WDA-D-SK / WDA-F-SK / WDA-K- SK possible with screw mounting (-SM). - steel painted to RAL 9010 (white) 05/18-3

Models and dimensions Dimensions Nozzle without accessories (not available with swivel head) WDA-W inter- WDA-F WDA-D WDA-K 1.) 3 x indentation for slotted shallowraised countersunkhead tapping screw DIN ISO 7051 pitch 3.9 Available sizes WDA / WDA-W / WDA-F / WDA-D / WDA-K / WDA-RA ød øa øe øf øg øk a L t P1 ød1 ød S L1 31 31,5 87 16 71 70 40 40 63 12 51 81 50 150 115 98 108 130 9-90 16 45 45 49 10 39 38 200* 50 50 34,5 10 24,5 23,5 63 63 163 14 149 148 181 80 80 114 18 96 95 250 215 198 208 230-185 24 87 87 95 14 81 800* 80 100 100 58 12 46 45 12 125 125 192 12 180 179 356 160 160 212 12 200 199 450 415 398 408 430-360 175 175 168 12 156 30 155 800* 200 200 99 12 87 86 400 400 845 770 752 808 815 20 340 20 320 x 724 319 * upon request, larger diameters are also possible! 05/18-4

Dimensions of accessories Swivel head (-SK, size 50 not possible) The adjustment of the nozzle can be done manually or electrically. WDA-F-SK / WDA-D-SK 1.) 3 x indentation for slotted shallowraised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 internal WDA-K-SK WDA-W-RA-SK (NW 400 not available) Available sizes WDA-...-SK ød øa øe øf øg øk a P H H1 M øb z S ød2 31 31,5 53 100 40 40 150 115 98 108 130 9 28 25 60 100 72 100 45 16-45 45 14 315* 63 63 104 80 80 25 55 200 250 215 198 208 230 130 170 125 200 65 24-87 87 36 1200* 100 100 20 29 12 125 125 30 92 400 160 160 110 450 415 398 408 430 28 200 240 155 392 90-175 175 71 30 1200* 200 200 22 65 400 400 845 770 752 808 815 20 20 110 335 375 375 755 230 x * upon request, larger diameters are also possible! 05/18-5

Electric actuator (-E1/2/3, only available from size 63) Mounted externally (standard) A = Left-hand design (standard) 0V = nozzles on top Direction of rotation: "R" Duct installation B = Right-hand design. 0V = nozzles on top Direction of rotation "L" For an externally fitted actuator, please make sure that the distance to the ceiling or wall is greater than 10 mm. List of actuators Drive on the inside Drive on the outside in size 63-200 in size 63-200 400 -E1 (230V AC, 3-Pkt.) Siemens GLB 331.2 Belimo NM230A-F Belimo GM230A -E2 (Standard, 24V AC, 0-10V DC) Siemens GLB 163.2E Belimo NM24A-SR-F Belimo GM24A-SR -E3 (24V AC, 3-Pkt.) Siemens GLB 131.2E Belimo NM24A-F Belimo GM24A Section A-A WDA-D-SK-E / WDA-F-SK-E Section A-A WDA-K-SK-E Section A-A WDA-W-SK-E Section A-A WDA-W-RA-SK-E inter- 05/18-6

Mounted internally (at an extra charge, size 400 not possible): WDA-D-SK-E / WDA-F-SK-E WDA-K-SK-E WDA-W-SK-E WDA-W-RA-SK-E For WDA-W-RA-SK actuator internal / external no cover plate necessary! inter- Available sizes WDA-...-SK-E / WDA-W-RA-SK-E (mounted internally / mounted externally) ød P øa øg øe øf H H2 ød2 b S Actuator mounting external internal 63 63 104 80 80 55 200 25 250 208 215 198 170 250-10 24 87 87 36 1200* 100 100 29 20 125 125 92 30 160 160 110 400 450 408 415 398 240 400-90 28 175 175 71 30 1200* 200 200 65 22 22 400 400 110 845 808 770 752 375 x x x 20 x * upon request, larger diameters are also possible! For size 400, an actuator cannot be mounted internally! 05/18-7

Reduction piece (-RS) (only available for sizes 63-200) without swivel head / with or without swirl disc external Available sizes -RS ød L1 ød1 P ød øa J1 N1 øg øk E 63 63 148 98 104 80 80 95 123 55 87 87 80 138 36 185 250 130 230 208 230 215 100 100 45 158 29 125 125 179 198 92 160 160 199 248 110 175 175 155 278 71 360 450 200 300 408 430 415 200 200 86 313 65 Twist disk (-DS 1/2) (only available for size 63-200) Swirl discs no. 1 and 2 only differ by having different perforations. The twist disks can be mounted for all models. Available sizes -DS without swivel head / with or without swirl disc external L ød ød 63 163 63 80 114 80 87 95 87 185 100 58 100 125 192 125 160 212 160 175 168 175 360 200 99 200 Damper (-DV) (only available for size 400) external 1.) 3 x indentation for slotted shallow-raised countersunk-head tapping screw DIN ISO 7051 pitch 3.9 05/18-8

Cover plate (-BR) (concealed mounting, only NW 63-200 available) Mounting on site Available sizes -BR WDA-F WDA-D WDA-K WDA-F-SK WDA-D-SK WDA-K-SK WDA-F-SK-E WDA-D-SK-E (only available for NW 63-200) WDA-W WDA-W-SK WDA-W-RA-SK øc b øc b 63-100 253 31 211 27 125-200 453 48 411 40 05/18-9

Ball impact guard (-BS) WDA-D-BS / WDA-K-BS The models WDA / WDA-W / WDA-F / WDA-RA are not available with ball impact guard. WDA-D-SK-BS / WDA-F-SK-BS Detail X 05/18-10

WDA-K-SK-BS The models WDA-W-SK / WDA-W-SK-RA / WDA-W-SK-E / WDA-W-SK-RA-E are not available with ball impact guard. Available sizes WDA-...-BS ød øa øc øe øf øg øk a P H L1 63 63 104 148 80 80 55 95 250 398 215 198 208 230 130 87 87 36 80 100 100 29 45 12 125 125 92 179 160 160 110 199 450 598 415 398 408 430 200 175 175 71 155 200 200 65 86 with electric actuator internal / external H WDA-K-SK-E-BS WDA-D-SK-E-BS WDA-F-Sk-E-BS internal external internal external 63-100 250 130 250 125-200 400 200 400 05/18-11

Technical Data Pressure loss and noise level WDA 31-50 WDA 63-100 WDA 125-200 05/18-12

Jet angle 1 WDA 31 7 14 WDA 40 5 10 WDA 45 6 12 WDA 50 5 10 WDA 63 6 12 WDA 63 twist disk no. 1 15 30 WDA 63 twist disk no. 2 21 42 WDA 80 5 10 WDA 80 twist disk no. 1 25 50 WDA 80 twist disk no. 2 35 70 WDA 87 5 10 WDA 87 twist disk no. 1 30 60 WDA 87 twist disk no. 2 35 70 WDA 100 5 10 WDA 100 twist disk no. 1 20 40 WDA 100 twist disk no. 2 26 52 1 WDA 125 6 12 WDA 125 twist disk no. 1 20 40 WDA 125 twist disk no. 2 26 52 WDA 160 10 20 WDA 160 twist disk no. 1 20 40 WDA 160 twist disk no. 2 26 52 WDA 175 8 16 WDA 175 twist disk no. 1 21 42 WDA 175 twist disk no. 2 26 52 WDA 200 8 16 WDA 200 twist disk no. 1 26 52 WDA 200 twist disk no. 2 30 60 Correction factor for twist disk WDA 63-200 DS 63 80 87 100 125 160 175 200 1 x 0.80 x 0.72 x 0.62 x 0.59 x 0.76 x 0.69 x 0.65 x 0.62 v max 2 x 0.65 x 0.40 x 0.35 x 0.31 x 0.64 x 0.57 x 0.53 x 0.47 1 x 0.93 x 0.75 x 0.70 x 0.62 x 0.91 x 0.84 x 0.80 x 0.76 y H 2 x 0.65 x 0.30 x 0.25 x 0.27 x 0.84 x 0.77 x 0.72 x 0.67 y 1 x 1.10 x 1.30 x 1.60 x 1.60 x 1.20 x 1.40 x 1.60 x 1.70 2 x 1.50 x 3.50 x 3.90 x 3.70 x 1.40 x 1.70 x 2.00 x 2.20 TV 1 x 0.67 x 0.64 x 0.65 x 0.56 x 0.69 x 0.68 x 0.67 x 0.66 2 x 0.60 x 0.54 x 0.49 x 0.38 x 0.59 x 0.55 x 0.54 x 0.49 i 1 x 1.20 x 1.40 x 1.50 x 1.70 x 1.30 x 1.40 x 1.50 x 1.60 2 x 1.60 x 2.60 x 2.80 x 3.20 x 1.50 x 1.70 x 1.90 x 2.10 1 x 1.04 x 1.08 x 1.10 x 1.15 x 1.03 x 1.10 x 1.13 x 1.20 p t 2 x 1.10 x 1.30 x 1.42 x 1.69 x 1.06 x 1.14 x 1.20 x 1.38 1 +6 +7 +8 +11 +5 +7 +8 +10 L WA 2 +10 +14 +18 +22 +7,5 +12 +14 +16,5 05/18-13

WDA-...-RS, with reduction piece Correction factor for twist disk WDA-...-RS 63-200 DS 63 80 87 100 125 160 175 200 1 x 1,02 x 1,09 x 1,17 x 1,21 x 1,06 x 1,065 x 1,08 x 1,11 p t 2 x 1,09 x 1,25 x 1,33 x 1,54 x 1,12 x 1,12 x 1,17 x 1,22 1 +4 +6 +8 +11,5 +4,5 +4,5 +8 +1 L WA 2 +8 +13 +16 +21 +8,5 +10 +13,5 +19 05/18-14

WDA 400 (without damper) WDA 400, damper OPEN 100 % WDA 400, damper OPEN 75 % WDA 400, damper OPEN 50 % 05/18-15

Maximum end velocity of jet WDA 31-50 WDA 63-100 WDA 125-200 v average = v max x 0.33 05/18-16

Maximum penetration WDA 31-50 WDA 63-100 WDA 125-200 05/18-17

Model for vertical nozzle mounting for cooling mode Correction factors of the expected average velocity in vertical installation of the nozzles T [K] without twist disk with twist disk no. 1 with twist disk no. 2-4 0,3 0,26 0,19-6 0,4 0,31 0,24-8 0,5 0,36 0,27-10 0,6 0,43 0,33 Calculation of the average velocity, relative to the T for vertically integrated nozzles. Example: WDA 200 at 250 m³/h, mounting height = 9.5 m, T = - 6 K: Head height = 9.5 m - 1.8 m = 7.7 m y (m) would be 7.7 m according to SCHAKO's design program; since the nozzle is mounted horizontally according to the design program,, the y value for vertically integrated nozzles must be entered under x (m)! x = 7.7 m According to the program, the maximum velocity in the isothermic state is 0.344 m/s at head height. Taking into account a correction factor of 0.4 at - 6 K without twist disk, this gives an average velocity of 0.344 m/s x 0.4 = 0.137 m/s. Result: WDA 200 at 250 m³/h, mounting height = 9.5 m, delta T = - 6 K, V average = 0.137 m/s at head height If the velocity is too high, simply calculate again using the correction factors of twist disk no. 1 or 2. 05/18-18

Induction ratios WDA 31-50 WDA 63-100 WDA 125-200 05/18-19

Temperature ratios WDA 31-50 WDA 63-100 WDA 125-200 05/18-20

Definitions Cooling mode Cooling mode example Assume: 100 V ZU = 250 m³/h x = 15 m T O = 8 K Solution: L WA = 21,64 db(a) p t = 54,42 Pa v max = 0,394 m/s TV = 0,033 i = 47,43 Example of an isotherm Assume: 100 V ZU = 250 m³/h x = 15 m Solution: L WA = 21,64 db(a) p t = 54,52 Pa v max = 0,394 m/s TV = 0,033 i = 47,43 Heating mode Heating mode example Assume: 100 H = 20 V ZU = 250 m³/h x 1 = 15 m T O = 8 K Solution: L WA = 21,64 db(a) p t = 54,52 Pa v max = 0,394 m/s y = 7,84 m y H = 8,67 m TV = 0,033 i = 47,43 05/18-21

Further data Horizontal throw (free jet) WDA 31-50 WDA 63-100 05/18-22

WDA 125-200 05/18-23

Connection diagrams of electric actuators Make Belimo OPEN/CLOSED control N L1 - + 3-point control N L1 - + Make Siemens (-E1) GLB 331.2.E three-point control on-site 0 on-site 1 2 3 1 2 3 0 1 0 1 optional optional Make Belimo (standard) (-E2) NM24A-SR-F / GM24A-SR Make Siemens (standard) (-E2) GLB 163.2.E steady control - + Y DC 0... 10 V U DC 2... 10 V on-site 1 2 3 5 Make Siemens (-E3) GLB 131.2.E three-point control optional optional 05/18-24

Technical data of electric actuators Make Belimo (-E1) NM230A-F Rated voltage: AC 100... 240 V, 50 / 60 Hz Functional range: AC 85... 265 V Power consumption - Operation: 2.5 W @ rated torque - Idle position 0.6 W - Dimensioning: 6 VA Torque (rated torque): min 10 Nm at the rated voltage Running time: 150 s Sound power level max. 35 db(a) Protection class: II protective insulation Protection type: IP54 in all mounting positions EMC: CE according to 89 / 336 / EEC Low voltage directive: CE according to 73 / 23 / EEC Ambient temperature: -30... +50 C Make Belimo (-E2) NM24A-SR-F Rated voltage: AC / DC 24 V, 50 / 60 Hz Functional range: AC / DC 19,2... 28.8 V Power consumption - Operation: 2 W @ rated torque - Idle position 0.4 W - Dimensioning: 4 VA Torque (rated torque): min 10 Nm at the rated voltage Activation - Actuator signal Y: DC 0... 10 V, input resistance typically 100 k - Operating range: DC 2... 10 V Positional feedback (Measuring voltage U): DC 2... 10 V, max. 1 ma Running time: 150 s Sound power level max. 35 db(a) Protection class: III Safety extra low voltage Protection type: IP54 in all mounting positions EMC: CE according to 89 / 336 / EEC Ambient temperature: -30... +50 C Make Belimo (-E3) NM24A-F Rated voltage: AC / DC 24 V, 50 / 60 Hz Functional range: AC / DC 19,2... 28.8 V Power consumption - Operation: 1.5 W @ rated torque - Idle position 0.2 W - Dimensioning: 3.5 VA Torque (rated torque): min 10 Nm at the rated voltage Running time: 150 s Sound power level max. 35 db(a) Protection class: III Safety extra low voltage Protection type: IP54 in all mounting positions EMC: CE according to 89 / 336 / EEC Ambient temperature: -30... +50 C Make Siemens (-E1) GLB 331.2.E / (-E2) GLB 163.2.E (standard) / (-E3) GLB 131.2.E Supply AC 24 V (SELV / PELV) -Operating voltage / Frequency -Power consumption GLB13..2 -GLB16..2 lifting rod is moving -GLB16..2 stopping state Supply AC/DC 230 V -Operating voltage / Frequency -Power consumption GLB33..2 Functional data -Nominal lifting power -Running time for 60 m stroke: Actuator signal Y for GLB 16..2 -Input voltage (wires 8-2) -Max. allowed input voltage Position detector for GLB 16..2 -Output voltage (wires 9-2) -Max. output current AC 24 V ±20 % / 50 / 60 Hz 2 VA / 1 W 3 VA / 2 W 1 W AC 230 V ±10 % / 50 / 60 Hz 2 VA / 1 W 250 N 150 s (50 Hz) / 125 s (60 Hz) DC 0...10 V, internally limited to DC 10 V DC 35 V DC 0...10 V / DC 10...0 V DC ± 1 ma Housing protection type - Protection type according to DIN 60 529 (Observe mounting information) IP 40 Protection class: -Insulation protection class EN 60 730 Environmental conditions -Temperature -30...+55 C / -30...+60 C 05/18-25

Make Belimo (-E1) GM230A Rated voltage: AC 100... 240 V, 50 / 60 Hz Functional range: AC 85... 265 V Power consumption - Operation: 4 W @ rated torque - Idle position 2 W - Dimensioning: 7 VA Torque (rated torque): min 40 Nm at the rated voltage Running time: 150 s Sound power level max. 45 db(a) Protection class: II protective insulation Protection type: IP54 in all mounting positions EMC: CE according to 89 / 336 / EEC Low voltage directive: CE according to 73 / 23 / EEC Ambient temperature: -30... +50 C Make Belimo (-E3) GM24A Rated voltage: AC / DC 24 V, 50 / 60 Hz Functional range: AC / DC 19.2... 28.8 V Power consumption - Operation: 4 W @ rated torque - Idle position 2 W - Dimensioning: 6 VA Torque (rated torque): min 40 Nm at the rated voltage Running time: 150 s Sound power level max. 45 db(a) Protection class: III Safety extra low voltage Protection type: IP54 in all mounting positions EMC: CE according to 89 / 336 / EEC Ambient temperature: -30... +50 C Make Belimo (-E2) GM24A-SR Rated voltage: AC / DC 24 V, 50 / 60 Hz Functional range: AC / DC 19.2... 28.8 V Power consumption - Operation: 4.5 W @ rated torque - Idle position 2 W - Dimensioning: 7 VA Torque (rated torque): min 40 Nm at the rated voltage Activation - Actuator signal Y: DC 0... 10 V, input resistance typically 100 k - Operating range: DC 2... 10 V Positional feedback (Measuring voltage U): DC 2... 10 V, max. 1 ma Running time: 150 s Sound power level max. 45 db(a) Protection class: III Safety extra low voltage Protection type: IP54 in all mounting positions EMC: CE according to 89 / 336 / EEC Ambient temperature: -30... +50 C 05/18-26

Legend V ZU (m³/h) [l/s] = Supply air volume V X (m³/h) [l/s] = total air jet volume at point x x+y (m) = horizontal and vertical throw x (m) = horizontal throw y (m) = vertical throw DEH (m) = Nozzle mounting height Z (m) = horizontal distance from the nozzle to the intersection of two jets S = approx. length of throw (isotherm) AB = Occupied area K ( ) = Angle of throw in cooling mode H ( ) = Angle of throw in heating mode p t (Pa) = Pressure loss T O (K) = Temperature difference between supply air temperature and room temperature ( T O = t ZU - t R ) T OH (K) = Temperature difference between air supply and room temperature in heating mode ( T OH = t ZUH - t RH ) T X (K) = Temperature difference at point x t ZU (K) = Supply air temperature t R (K) = Room temperature L WA [db(a)] = A-weighted sound power level v max (m/s) = Maximum end velocity of jet v mittel (m/s) = Average end velocity of jet y H (m) = Maximum penetration in heating mode TV = Temperature ratio (TV = T X / T O ) i (-) = Induction ratio (i = V X / V ZU ) (kg/m³) = Density DS = twist disk (mm) = Nominal width He (m) = Heating Kü (m) = Cooling 05/18-27

Ordering details Long throw nozzle type WDA for duct installation (with saddle bracket) -RA (size 400 not possible) only nozzle - for flexible duct connection -F for spiral duct connection -W for installation in ceilings and walls -D for duct installation -K for duct installation (with saddle bracket) W-RA (size 400 not possible) without swivel head - with swivel head -SK 50 31 40 45 63 80 87 100 125 160 175 200 NW 400 Accessories: twist disk (s 63-200 available) -DS 1 2 Reduction piece (only available for sizes 63-200) -RS Ballschutzkorb -BS for WDA-D / WDA-K / WDA-D-SK / WDA-F-SK / WDA-K-SK only (NW 63-200 only) Damper -DV (for size 400) right R external Electric actuator (only sizes 63-400) left L internal (NW 400 not available) Cover plate for WDA-D / WDA-F / WDA-W / WDA-K / WDA-D-SK / WDA-F-SK / WDA-W-SK / WDA-W-RA-SK / WDA-K-SK / WDA-D-SK-E / WDA-F-SK-E only -BR (only available for NW 63-200) 230 V AC (3-point activation) -E1 24 V AC 0-10 V -E2 24 V AC (3-point activation) -E3 Order example WDA-D-SK-100 Unless stated otherwise, the thick-frame model will be delivered! 05/18-28

Specification texts Long throw nozzle for air-conditioning of large and high rooms, such as halls, theatres or concert halls. The cone-shaped body of the nozzle increases air velocity ensuring a stable core jet. This results in very long throws. The dynamic internal construction of the jet nozzle allows a very high exit velocity at low noise levels and high induction. The technical data is secured and guaranteed by measurements and documentation in Schako's own fluid dynamics and acoustics laboratory. Suitable for cooling and heating modes. A wide range of connection and installation options such as wall, ceiling, duct or pipes. Consists of the nozzle part made of aluminum (size 31-63 and 125-400) or sheet steel (size 80-100) each painted with a high-quality powder coating to a RAL colour (RAL 9010, white, standard). Suitable for use in VAV systems. NW Volumetric flows in m³/h at: 35 db(a) 40 db(a) 31 58 71 40 92 110 45 108 130 50 120 145 63 205 245 80 315 370 87 340 420 100 400 485 125 720 900 160 1000 1220 175 1100 1350 200 1285 1550 400 4200 5000 Product: SCHAKO type WDA - for flexible duct connection, with mounting ring and connection pipe Product: SCHAKO type WDA-F - for spiral duct connection, with mounting ring and connection pipe. Product: SCHAKO type WDA-W - for ceiling / wall mounting, with mounting ring and connection pipe. Product: SCHAKO type WDA-D - for duct installation, with mounting ring. Product: SCHAKO type WDA-K - for duct connection, with saddle bracket, not available with swivel head (size 400 not possible) Product: SCHAKO type WDA-RA - for duct connection, with saddle bracket, available with swivel head (size 400 not possible) Product: SCHAKO type WDA-W-RA Accessories: - Swivel head (-SK) for adjusting air outlet direction, without any change in the pressure loss or noise level, consisting of: - sheet steel painted with a high-quality powder coating to the RAL colour of the nozzle (standard RAL 9010, white). (sizes 31-45 and 63-100) - aluminium painted with a high-quality powder coating to the RAL colour of the nozzle (standard RAL 9010, white). (size 125-400). - Twist disk (-DS) consisting of sheet steel painted with a highquality powder coating to RAL 9005 (black) which increases induction, reducing length of throw and end velocities of jet (sizes 63-200). Model 1 or 2 - Reduction piece (-RS) for connecting small pipe diameters, made of sheet steel painted with a high-quality powder coating to the colour of the nozzle (only available with sizes 63-200 of model WDA-F/W). - electric actuator (only available with swivel head sizes 63-400) - Actuator mounted externally (standard) - Actuator mounted internally (at an extra charge) (not possible for size 400) - E1 (230 V AC, 3-point activation) - E2 (24 V AC, 0-10V; standard) - E3 (24 V AC, 3-point activation) - Cover plate (-BR) for covering the fixing and fastening screws, made of sheet steel painted with a high-quality powder coating in the same color as the nozzle (only NW 63-200 available). - Damper (-DV), for manual volumetric flow adjustment, made of galvanised sheet steel (size 400 only) - Ball impact guard (-BS), made of steel painted with a highquality powder coating to RAL 9010 (white) (for WDA-D / WDA-K / WDA-D-SK / WDA-F-SK / WDA-K-SK only) (NW 63-200 only). 05/18-29