3RT2028-1BB40. at rectangular impulse at DC 10g / 5 ms, 7,5g / 10 ms at sine pulse at DC 15g / 5 ms, 10g / 10 ms

Similar documents
3RV2011-1AA10 CIRCUIT-BREAKER SCREW CONNECTION 1.6A

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

CONTACTOR, AC KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION. General details: Main circuit: Product brand name. Size of the contactor

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

General technical data. Ambient conditions

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RT14 Contactors with 3 Main Contacts

AF40... AF96 3-pole contactors Technical data

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Meta Solution. Contactors and Overload relays

Application Mini Contactors for Motors and Resistive Loads

Protection Equipment

Industrial Contactors CTX 3 3P 185A - 800A

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Technical specifications

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Thermal Overload Relays - WEG RW Series, 2 Pole

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

SIRIUS 3RU2 Thermal Overload Relays

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

B Mini Contactor V Hz

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

Micro Contactor MA Series

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Application Mini Contactors for Motors and Resistive Loads

Mini contactors B6, BC6 with 3 pole

DIN EN UL 508 / CSA 3RF A A 0 2

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Solid State Relays, 3-phase

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

Manual Motor Starters. Meta-MEC

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Rotary Cam Switches. Rotary Cam Switches

Protection Equipment. 5/2 Introduction

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

D509E. Manual Motor - Starters

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

For Operation in the Control Cabinet

Quick selection table

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Low-Voltage Controls and Distribution

SENTRON SIVACON ALPHA

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Bulletin 193-T1 Bimetallic Overload Relays

Thermal overload relay TF140DU and TF140DU-V1000

BC Mini Contactor VDC

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Short form catalogue. Motor protection & control

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Protective Devices: Circuit-Breakers 1 )

3SE3 1 SIGUARD Position Switches

MS General Information Extended Product Type: MS

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

BETA Switching Switches and Light Indicators

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

SENTRON Switching and Protection Devices Switch Disconnectors

22AF 40AF AF 150AF 225AF 400AF 800AF

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Manual Motor Starters

CI-TI Contactors and Motor Starters Type CI 6-50

ASL09..S 3-pole Contactors - Spring Terminals

Load and Motor Switches, Load-Break Switches Series 8549

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Application Description

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

3TM Vacuum Contactors

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Thermal overload relay TF65 and TF96

TAE pole Contactors


Electronic overload relay EF65, EF96 and EF146

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

CI-TI Contactors and motor starters Types CI 61 - CI 98

3VU13, 3VU16 Circuit-Breakers

Controls. CONTACTORS CWB Line (up to 40A)

SFS-UFS Single Foot Switches

Transcription:

Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > SIRIUS 3RT20 Contactors, 3-pole, up to 18.5 kw / 25 hp 3RT2028-1BB40 CONTACTOR,AC3:18,5KW 1NO+1NC DC24V Technical / CAx data Technical Data CAx data CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3- POLE, SZ S0 SCREW TERMINAL General technical data: Product brand nam e SIRIUS Size of the contactor S0 Product extens ion / auxiliary s w itch Yes Protection clas s IP / on the front IP20 Pr otection agains t electr ical s hock finger-safe Degr ee of pollution 3 Ins tallation altitude / at a height over s ea level / m 2,000 m axim um Am bient tem perature / during s torage C -55 80 Am bient tem perature / during operating C -25 60 Shock res is tance at rectangular impulse at DC 10g / 5 ms, 7,5g / 10 ms at sine pulse at DC 15g / 5 ms, 10g / 10 ms Im puls e voltage res is tance / rated value kv 6 Ins ulation voltage / r ated value V 690 Mechanical operating cycles as operating tim e of the contactor / typical 10,000,000 of the contactor with added auxiliary switch block / typical of the contactor with added electronicscompatible auxiliary switch block / typical 10,000,000 5,000,000

Main circuit: Num ber of NC contacts / for m ain contacts 0 Num ber of NO contacts / for m ain contacts 3 Operating current at AC-1 / at 400 V at 40 C ambient temperature / rated value A 50 at 60 C ambient temperature / rated value A 42 at AC-2 / at 400 V / rated value A 38 at AC-3 / at 400 V / rated value A 38 at AC-4 / at 400 V / rated value A 22 Operating current with 1 current path / at DC-1 at 110 V / rated value A 4.5 with 2 current paths in series / at DC-1 at 110 V / rated value A 35 with 3 current paths in series / at DC-1 at 110 V / rated value A 35 with 1 current path / at DC-3 / at DC-5 at 24 V / rated value A 20 at 110 V / rated value A 2.5 with 2 current paths in series / at DC-3 / at DC-5 at 110 V / rated value A 15 with 3 current paths in series / at DC-3 / at DC-5 Service pow er at 110 V / rated value A 35 at AC-2 / at 400 V / rated value kw 18.5 at AC-3 / at 400 V / rated value kw 18.5 at AC-4 / at 400 V / rated value kw 11 Active pow er los s / per conductor / typical W 3.8 Off-load operating frequency at AC 1/h 5,000 at DC 1/h 1,500 Frequency of operation at AC-1 / according to IEC 60947-6-2 / at AC-2 / according to IEC 60947-6-2 / at AC-3 / according to IEC 60947-6-2 / 1/h 1,000 1/h 750 1/h 750

at AC-4 / according to IEC 60947-6-2 / 1/h 250 Control circuit: Type of voltage / of the controlled s upply voltage DC Control s upply voltage / 1 for DC / rated value V 24 Work ing range factor s upply voltage rated value / of the m agnet coil for DC 0.8 1.1 Pull-in pow er / of the s olenoid / for DC W 5.9 Holding pow er / of the s olenoid / for DC W 5.9 Clos ing delay at DC ms 50 170 Opening delay at DC ms 15 17.5 Ar cing tim e ms 10 10 Auxiliary circuit: Contact r eliability / of the auxiliar y contacts 1 faulty sw itching per 100 million (17 V, 1 ma) Num ber of NC contacts / for auxiliary contacts / 1 ins tantaneous s w itching Num ber of NO contacts / for auxiliary contacts / 1 ins tantaneous s w itching Operating current / of the auxiliary contacts at AC-12 / A 10 at AC-15 at 230 V A 6 at 400 V A 3 at DC-12 at 48 V A 6 at 60 V A 6 at 110 V A 3 at 220 V A 1 at DC-13 at 24 V A 6 at 48 V A 2 at 60 V A 2 at 110 V A 1 at 220 V A 0.3 Short-circuit: Des ign of the fus e link for short-circuit protection of the auxiliary switch / required for short-circuit protection of the main circuit fuse gl/gg: 10 A with type of assignment 1 / required gl/gg LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 100 A at type of coordination 2 / required gl/gg LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35A Installation/mounting/dimensions: Built in or ientation vertical

Type of m ounting screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 Type of fixing/fixation / s er ies ins tallation Yes Width mm 45 Height mm 85 Depth mm 107 Dis tance, to be m aintained, to the rank s as s em bly / mm 0 s idew ards Dis tance, to be m aintained, to earthed part / s idew ards mm 6 Connections: Des ign of the electrical connection for main current circuit screw -type terminals for auxiliary and control current circuit screw -type terminals Type of the connectable conductor cros s -s ection for main contacts solid 2x (1... 2.5 mm2), 2x (2.5... 10 mm2) stranded 2x (1... 2.5 mm2), 2x (2.5... 10 mm2) finely stranded with conductor end processing 2x (1... 2.5 mm2), 2x (2.5... 6 mm2), 1x 10 mm2 for AWG conductors / for main contacts 2x (16... 12), 2x (14... 8) for auxiliary contacts solid 2x (0.5... 1.5 mm2), 2x (0.75... 2.5 mm2) finely stranded with conductor end processing 2x (0.5... 1.5 mm2), 2x (0.75... 2.5 mm2) for AWG conductors / for auxiliary contacts 2x (20... 16), 2x (18... 14) Certificates/approvals: General Product Approval Tes t Certificates ROSTEST Manufacturer Shipping Appr oval Shipping Appr oval other Manufacturer UL/CSA ratings: yielded m echanical perform ance (hp) for single-phase squirrel cage motors at 110/120 V / rated value hp 3 at 230 V / rated value hp 5 for three-phase squirrel cage motors at 200/208 V / rated value hp 10 at 220/230 V / rated value hp 10

at 460/480 V / rated value hp 25 at 575/600 V / rated value hp 25 Operating current (FLA) / for three-phas e s quirrel cage m otors at 480 V / rated value A 34 at 600 V / rated value A 27 Contact rating des ignation / for auxiliary contacts / according to UL Safety:related Parameter: B10 value / w ith high dem and rate A600 / Q600 according to SN 31920 1,000,000 T1 value / for proof tes t interval or s ervice life according to IEC 61508 a 20 Proportion of dangerous failures with low demand rate / according to SN 31920 with high demand rate / according to SN 31920 Failure rate (FIT value) / w ith low dem and rate % 40 % 73 according to SN 31920 FIT 100 Product function mirror contact to IEC 60947-4-1 Yes positively driven operation to IEC 60947-5-1 No Further information: Inform ation- and Dow nloadcenter (Catalogs, Brochures, ) http://www.siemens.com/industrial-controls/catalogs Indus try Mall (Online ordering s ys tem ) http://www.siemens.com/industrial-controls/mall Cax online generator: http://www.siemens.com/cax Service&Support (Manuals, Certificates, Characteris tics, FAQs,...) http://support.automation.siemens.com/ww/view/en/3rt2028-1bb40/all Im age databas e (product im ages, 2D dim ens ion draw ings, 3D m odels, device circuit diagram s,...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3rt2028-1bb40

las t change: Aug 24, 2011 Siemens AG 2011 - Corporate Information - Privacy Policy - Terms of Use