Technical Data Sheet Sigma Series DS Meter

Similar documents
Technical Data Sheet Sigma Series DG Meter

Technical Data Sheet Sigma Series DE Meter

SIGMA SERIES DE METER

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

Smart Look Series Meter

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

PLATINUM SERIES SWITCHBOARD METERS

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

DIN Panel Meters Long Scale

Smart Look Series Meter

ANSI Switchboard Meters

AC Wattmeters and VArmeters

Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy

ROTARY CAM SWITCHES CAM SERIES. User Manual - Issue 1.1

Century Style Analog Panel Meters

MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES

B2, B3, B4, B5, B6 Measuring shunts

Standard Program Technical Description

Square Shape Instrument - PK Series

Wide-Vue Analog Panel Meters

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Wide-Vue Analog Panel Meters

Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION

BIG-VUE Series Meter

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

Product Information. Viewline Temperature gauges. Description. Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature.

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Wind display type WSDI-2 DATA SHEET

Data Sheet. Data Sheet- Shunts. 50 mv 60 mv 75 mv 100 mv 150 mv. Shunts Class 0.5, 1.0

EM DC Multi-Function DC Energy Meter

Scheda prodotto Relè Series B

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution.

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

LED Digital Analog Combination

Do not risk your safety!

Moving Coil Indicators with direct temperature sensor input

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Basic Series Accessories Low Voltage Current Transformer Class 1

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Differential Pressure Sensors

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Price List Effective from :

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

DKG-114 MANUAL AND REMOTE START UNIT

Modulating control valve PN16 with magnetic actuator

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Differential Pressure Sensors

Differential pressure sensor

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Actuators for small valves

D509E. Manual Motor - Starters

Description. Positive safety relays

Magnetic and Hydraulic-Magnetic Circuit Breaker

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Screw-in resistance thermometers with plug connector

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Thermal Overcurrent Circuit Breaker 3120-F...

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

Pressure sensor for liquid and gaseous media QBE620-P...

CAUTION CM-SE CM-S21 CM-S41

Scheda prodotto Relè Series E

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Thermal Overcurrent Circuit Breaker 3120-F...

Panel Meters and Accessories Digital Panel Meter

Magnetic and Hydraulic-Magnetic Circuit Breaker

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Magnetic and Hydraulic-Magnetic Circuit Breaker

SWITCHGEAR. 4G cam switches

Thermal Overcurrent Circuit Breaker 3120-F...

Bimetal Thermometers Model 54, Heavy Duty Series

Thermal Overcurrent Circuit Breaker 3120-F...

PA39 TYPE PANEL POWER METERS APPLICATION CHOICE OF MEASURING RANGE TECHNICAL DATA. Additional errors

Overview of types. Technical data. Safety notes

Thermal Overcurrent Circuit Breaker 3120-F...

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

Thermal Overcurrent Circuit Breaker 3120-F...

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Pressure transmitter JUMO dtrans p02

PPT 802, Proximity Probe Transducer System

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant

Pressure Transmitters

Differential Pressure Sensors

INSERTION flow sensor for continuous flow measurement

Differential Pressure Sensors

Cat N 3. OVERALL DIMENSIONS

AF40... AF96 3-pole contactors Technical data

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Product Data Sheet 8412 NHU-519

Lexium integrated drives

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Transcription:

Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments offer several advantages in switchboards and Generating Set Panels. Number of meters can be mounted in a Panel Cut out (Mosaic mounting). Front glass, Bezel & Dial can be easily replaced. Special Features Linear scale. Glass lled polycarbonate housing (UL 94-V-0) Knife edge pointer. Easily replaceble glass and bezel.

Application The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. Movement Moving coil movement has pivots of very high hardness. Movement is suspended between two spring loaded sapphire jewels. Movement is properly shielded & critically damped by eddy currents induced in coil former. Mechanical Data Case details Case material Front facia Colour of bezel Position of use Panel xing Mounting Panel thickness Terminals Moulded square case suitable for mounting in Control / switchgear panels Machinery consoles. Polycarbonate, ame retardant and drip proof as per UL 94 V-0. Glass Black Vertical Mounting Clamp Stackable in a single cutout < 25 mm Voltmeters and Ammeters < 5 A Ammeters > 5A Ammeters > 60A Electrical Data Measured Quantity Overload capacity acc. to IEC 51 Short Duration Voltmeters Hexagon studs, M4 screws and wire clamps E3 (DIN 46282) Threaded studs M6 with nuts Threaded studs M8 with nuts AC voltage or current 1.2 times rated voltage /current Continuously 2 times for 0.5 sec : 9 overloads 2 times for 5 sec : 1 overloads Ammeters DS 48, 72, 96 10 times for 0.5 sec : 9 overloads 10 times for 5 sec : 1 overload Enclosure code (IEC 529) IP 52 case cover IP 00 for terminals without back IP 20 for terminals with back cover Insulation class Group A according to VDE 0110 Rated insulation voltage DS 48 : 660V DS 72/96 : 1KV Proof Voltage DS 48 : 2KV DS72/96 : 3KV Installation catagory DS 48 300 V CAT III (IEC 1010) DS 72/96 600V CAT III(IEC 1010) Insulation resistance > 50 Mohm at 500 V d.c. Accuracy class 2.5 Total lead resistance of 0.035 ohm or less considered for mv ranges while calibration. *6 Not applicable for DS 48 Burden Connection to shunt Power Consumtion: 6mA Lead resistance: 0.06 W +10% 1A... 60 A Voltage drop : +10% > 1V 1000 W/V +5% Applicable Standards Nominal case and cutout dimensions for indicating Electrical instruments Scale and pointer for electrical measuring instruments Connections and Terminal markings for panel meters DIN IEC 61554 DIN 43802 DIN 43807 Terminal bolts/leads DIN 46200/46282 Safety requirements and protective measures for Electrical indicating. instruments and their accessories Performance speci cations for direct acting indicating analogue electrical measuring instruments and their accessories DIN 40050, VDE 0110, VDE 0410 IEC 529, IEC 1010 IEC51/DINEN60051 DIN 43701 Environmental conditions VDE / VDI 3540 Front frames for indicating measuring instruments Principle dimensions DIN 43701 UL Compatibility UL 94 V-0 Technical conditions of delivery for electrical instruments DIN 43701 www.sifamtinsley.com Page 1 of 5

Mechanical strength (Free fall test,vibration test) Reference Conditions Accuracy class Ambient temperature 23 C ± 2 C 1.5 according to IEC 51/DIN EN 60051 Position of use Nominal position ±1 Input Rated value of measured quantity Other Conditions IEC 51/DIN EN 60051 Nominal Range of use Ambient Temperature 0...50 C Position of use Vertical ± 5 External Magnetic Field At 0.4 ka/m Environmental Conditions VDE- 0411, IEC 61010 Comply with following European directives: : 2004 / 108 / EC (EMC directive ), 2006 / 95 /EC (low voltage directive) & amendment 93/68/EEC, For CE Marking. Scale and Pointer Pointer Pointer de ection 0...90 Scale characteristics Scale division Scale length Scale Interchangeability Knife - edge pointer Linear*1 Coarse - ne DS 48 DS 72 DS 96 DS 144 41 mm 63 mm 97mm 146mm Interchangeable* Standard Measuring Ranges D. C. Voltage D. C. Voltage Rated Value Approx Voltage drop Rated Value Sensitivity ( + 10%) 15uA 25uA 40 ua 50 ua 60 ua 100 ua 150 ua 250 ua 400 ua 500 ua 600 ua 1 ma 1.5 ma 2.5 ma 4 ma 5 ma 6 ma 10 ma 15 ma 20 ma 25 ma 40 ma 60 ma 100 ma 150 ma 250 ma 400 ma 600 ma 1 A 1.5 A 2. 5 A 4 A 5 A 6 A 10 A 15 A 20 A 25 A 30 A 40 A 60 A *6 100 A For use on transducer 4-20 ma 140 mv 240 mv 374 mv 424 mv 600 mv 400 mv 600 mv 140 mv 540 mv 540 mv 540 mv 37 mv 11 mv 72 mv 72 mv 15 mv 3.33kohm/V 25 mv 3.33kohm/V 40 mv 3.33kohm/V 50 mv 3.33kohm/V 1 kohm/v 75 mv 1 kohm/v 100 mv 1 kohm/v 150 mv 1 kohm/v 250 mv 1 kohm/v 400 mv 1 kohm/v 600 mv 1 kohm/v 1 V 1 kohm/v 1.5 V 1 kohm/v 2.5 V 1 kohm/v 4 V 1 kohm/v 6 V 1 kohm/v 10 V 1 kohm/v 15 V 1 kohm/v 25 V 1 kohm/v 30 V 1 kohm/v 40 V 1 Kohm/V 50 V 1 kohm/v 60 V 1 kohm/v 100 V 1 kohm/v 150 V 1 kohm/v 200 V 1 kohm/v 250 V 1 kohm/v 300 V 1 kohm/v 400 V 1 kohm/v 500 V 1 kohm/v 600 V 1 kohm/v 1000 V 1 kohm/v For use on external shunt 1 kohm/v 75 mv 1 kohm/v 150 mv 1 kohm/v - Climatic Suitability Climate category II as per IS : 1248 (climatic class 3 according to VDE/VDI 3540) Operating Temperature Storage temperature Relative humidity Shock resistance Vibration resistance - 10... + 55 C - 25...+65 C < 75% annual average, non condensing 15 g. for pulse duration 11ms 10-55-10Hz for ampli. 0.15mm (1.5g at50hz) Pollution degree 2 www.sifamtinsley.com Page 2 of 5

Sigma Series Alpha DS Meter 70 Options Case Front Facia Antiglare glass Electrical Connections 11 12 Color of bezel Red index pointer Red, yellow, blue, white Front adjustable on site DC voltage + - X position of use on request 0...180 Dial Blank dial With initial and end values marked DC current + - 11 12 X Special markings Numbering/Lettering Division dials Color markings/bands Over range (Voltmeters) Basic divisions without numbering Red or green Two, three and ve times over range Dimensions Over range (Ammeters) Others Zero position Six times over range Centre zero or off-set zero f Increased sensitivity Adjustment of Resistance (Sensitivity) 4kohm/V for voltmeters 1...600V 10 kohm/v for Voltmeters 15..150V 0 Within + 1% at 23 C a 1 x a 2 I 1 x I 2 Accessories Safety Terminal Protection Full sized polycarbonate back cover to provide protection against accidental contact (hand and ngers) h t www.sifamtinsley.com Page 3 of 5

Front in mm Nominal Dimensions, mm a 1 x a2 h Cutout, mm I x I 1 2 Installation Depth Including Terminal (t), mm < 4A (M4) 5...60A (M6) 60..100A(M8) Installation Depth Incl. Full back Cover (f), mm < 4A 5...60A 60...100A +0.6 +0.6 48 x 48 48 x 48 5.5 45 x 45 72 x 72 72 x 72 5.5 68 x 68 96 x 96 96 x 96 5.5 92 x 92 144 x 144 144 x 144 5.5 138 x 138 +0.7 +0.7 +0.8 +0.8 +1 +1 54 72 62.5 75 54 67 67 62.5 70 70 54 67 67 62.5 70 70 54 67 67 62.5 70 70 Ordering Information- Only For Representative Products Size: 48 x 48 Ammeter Part No. Description PQ94-I18L2N1CAW0ST PQ94-I19L2N1CAW0ST PQ44-I12L2N1CAW0ST 1mA DC indicator PQ94-I20L2N1CAW0ST 10mA DC indicator 15mA DC indicator 20mA DC indicator PQ44-I13L2N1CAW0ST 1.5mA DC indicator PQ94-I22L2N1CAW0ST 40mA DC indicator PQ44-I14L2N1CAW0ST 2.5mA DC indicator PQ94-I23L2N1CAW0ST 60mA DC indicator PQ44-I16L2N1CAW0ST 5mA DC indicator PQ94-I42L2N1CAW0ST 4-20mA DC indicator PQ44-I17L2N1CAW0ST 6mA DC indicator Size: 48 x 48 Voltmeter PQ44-I18L2N1CAW0ST PQ44-I19L2N1CAW0ST PQ44-I20L2N1CAW0ST PQ44-I22L2N1CAW0ST PQ44-I23L2N1CAW0ST PQ44-I42L2N1CAW0ST 10mA DC indicator 15mA DC indicator 20mA DC indicator 40mA DC indicator 60mA DC indicator 4-20mA DC indicator Part No. PQ44-VOSL2N1CAW0ST PQ44-VOTL2N1CAW0ST PQ44-VOVL2N1CAW0ST PQ44-VOXL2N1CAW0ST PQ44-VOYL2N1CAW0ST Description 0-10V DC Voltmeter 0-15V DC Voltmeter 0-30V DC Voltmeter 0-50V DC Voltmeter 0-60V DC Voltmeter Size: 72 x 72 Ammeter PQ44-VOZL2N1CAW0ST 0-100V DC Voltmeter Part No. Description PQ44-V1AL2N1CAW0ST 0-150V DC Voltmeter PQ74-I12L2N1CAW0ST 1mA DC indicator Size: 72 x 72 Voltmeter PQ74-I13L2N1CAW0ST 1.5mA DC indicator Part No. Description PQ74-I14L2N1CAW0ST 2.5mA DC indicator PQ74-VOSL2N1CAW0ST 0-10V DC Voltmeter PQ74-I16L2N1CAW0ST 5mA DC indicator PQ74-VOTL2N1CAW0ST 0-15V DC Voltmeter PQ74-I17L2N1CAW0ST 6mA DC indicator PQ74-VOVL2N1CAW0ST 0-30V DC Voltmeter PQ74-I18L2N1CAW0ST 10mA DC indicator PQ74-VOXL2N1CAW0ST 0-50V DC Voltmeter PQ74-I19L2N1CAW0ST 15mA DC indicator PQ74-VOYL2N1CAW0ST 0-60V DC Voltmeter PQ74-I20L2N1CAW0ST 20mA DC indicator PQ74-VOZL2N1CAW0ST 0-100V DC Voltmeter PQ74-I22L2N1CAW0ST 40mA DC indicator PQ74-V1AL2N1CAW0ST 0-150V DC Voltmeter PQ74-I23L2N1CAW0ST 60mA DC indicator PQ74-I42L2N1CAW0ST 4-20mA DC indicator Size: 96 x 96 Ammeter Part No. Description Size: 96 x 96 Voltmeter Part No. Description PQ94-VOSL2N1CAW0ST 0-10V DC Voltmeter PQ94-VOTL2N1CAW0ST 0-15V DC Voltmeter PQ94-I12L2N1CAW0ST 1mA DC indicator PQ94-VOVL2N1CAW0ST 0-30V DC Voltmeter PQ94-I13L2N1CAW0ST 1.5mA DC indicator PQ94-VOXL2N1CAW0ST 0-50V DC Voltmeter PQ94-I14L2N1CAW0ST 2.5mA DC indicator PQ94-VOYL2N1CAW0ST 0-60V DC Voltmeter PQ94-I16L2N1CAW0ST 5mA DC indicator PQ94-VOZL2N1CAW0ST 0-100V DC Voltmeter PQ94-I17L2N1CAW0ST 6mA DC indicator PQ94-V1AL2N1CAW0ST 0-150V DC Voltmeter www.sifamtinsley.com Page 4 of 5

For more details and product codes, please contact our local of ce Sifam Tinsley Instrumentation Inc. 3105, Creekside Village Drive, Suite No. 801, Kennesaw, Georgia 30144 (USA) E-mail Id : psk@sifamtinsley.com Web : www.sifamtinsley.com Contact No. : +1 404 736 4903 Sifam Tinsley Instrumentation Ltd Unit 1 Warner Drive, Springwood Industrial Estate Braintree, Essex, UK, CM72YW E-mail: sales@sifamtinsley.com Web: www.sifamtinsley.com/uk Contact: +44(0)1803615139 www.sifamtinsley.com Page 5 of 5