& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Similar documents
DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

DC POWER SUPPLY ALIMENTATION C.C.

PRECISION MILLI/MICRO OHMMETER INSTRUCTION MANUAL

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Switching DC Power Supply

EPS/ELA-Series User Manual EPS/ELA 250W

DC POWER SUPPLY (Switching mode)

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

True RMS Autoranging Multimeter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Autoranging Multimeter

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

Triple Output Power Supply

Model 1900, 1901, 1902 Switching DC Power Supply

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

KEPCO Will Point You In The Right Direction!

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Autoranging Industrial Multimeter

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

Features. Description. Table of Contents

INSTRUCTION MANUAL Model 1743B

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

USER MANUAL. Insulation Tester + DMM. Model MG320

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

Model 1900, 1901, 1902 Switching DC Power Supply

Declaration of Conformity

Model Fixed Rack-Mount Kit

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Mini Multimeter with Non-Contact Voltage Detector (NCV)

System 3 ZB1PS Device Chassis. Operator s Manual

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Model 1693, 1694 Switching DC Power Supply

SAFETY TERMS AND SYMBOLS

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Model 1672, 1673 Triple Output Power Supply

Rental Industry Safety Tester Safe Check 5s

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

DC REGULATED POWER SUPPLY

DC REGULATED POWER SUPPLY

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

OPERATING INSTRUCTIONS

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Digital Multimeter User's Manual

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

OWNER S MANUAL Please read this manual before operating your power supply

362 Clamp Meter. Users Manual

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

OPERATING INSTRUCTION

Triple Output High Resolution Power Supply. User Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Electronic Ballast EVG 2000-T

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

LINE CONDITIONERS USER'S GUIDE

DIGITAL RCD(ELCB) TESTER

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Model Insulation Tester / Megohmmeter. User Manual

1.Safe testing IMPORTANT:

Table of Contents Title Page No.

DC Master 24/ A

365 Detachable Jaw True-rms Clamp Meter

OPERATING INSTRUCTION

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

OPERATING INSTRUCTIONS

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

i400s Calibration Information Introduction

KEWTECH. KT56 digital multi function tester. Instruction manual

i3000s/i2000 Flex AC Current Probe

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter

707Ex. Users Manual. ma Calibrator

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

DRB-1 Series Instruction Manual

Transcription:

72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com 1

Introduction This series of bench power supplies offer high power outputs (in excess of 350 Watts) in a casing which is both compact and lightweight when compared with conventional designs. Their high performance is derived from a regulator design which combines switch-mode and linear techniques to achieve high efficiency with excellent regulation, transient response and very low noise. The supplies feature high accuracy voltage and current metering on bright 0.5" LEDs, overvoltage and thermal protection, and remote sense terminals. The output operates in constant voltage or constant current mode with automatic crossover and mode indication. Coarse and fine controls permit the output voltage to be set within 10 mv and the current limit control is logarithmic to give good resolution at low current settings. The supplies have a robust steel case which is half-rack width (3U height). They are Safety Class I, Installation Category II instruments which meet IEC 1010-1 safety requirements and EN50081-1 and EN50082-1 EMC standards. Specification OUTPUT SPECIFICATIONS Voltage Range: Current Range: Output Voltage Setting: Output Current Setting: Output Mode: Output Switch: Output Terminals: Sensing: Output Impedance: Output Protection: OVP Range: OVP Delay: Load & Line Regulation: Ripple & Noise: HF Common Mode Noise: Transient Response: Temperature Coefficient: Nominally 0-35V (35V/10A) Nominally 0-18V (18V/20A) Nominally 0-10A (35V/10A) Nominally 0-20A (18V/20A) By coarse and fine controls; 10mV setting resolution. By single semi-logarithmic control; 10mA setting resolution. Constant voltage or constant current with automatic crossover. Electronic. Preset voltage and current displayed when off. 4mm terminals on front panel, screw terminals at rear. Remote via rear panel screw terminals or direct via shorting strip (supplied). <1mΩ in constant voltage mode. >5kΩ in constant current mode (voltage limit at max.). Forward protection by Over-Voltage-Protection (OVP) trip; maximum voltage that should be applied to the terminals is 50V. Reverse protection by diode clamp for reverse currents up to 3A. 10% to 110% of maximum output voltage set by front panel screwdriver adjustment. <200µs <0.01% of maximum output for 90% load change or 10% line change. <1mV rms typical in constant voltage <3mA rms typical in constant current. Typically <3mV rms, <10mV peak. 20µs to within 50mV of setting for 90% load change. Typically <100 ppm/ C. 2 www.tenma.com

Protection Functions: Status Indication: METER SPECIFICATIONS Meter Types: Meter Resolution: Meter Accuracy: Overvoltage trip. Regulator overtemperature. Sense miswiring. Output off lamp Constant voltage mode lamp Constant current mode lamp Trip message on display. Dual 4 digit meters with 12.5mm (0.5") LEDs. Reading rate 4Hz. 10mV, 10mA Voltage 0.2% of reading ± 1 digit, current 0.5% of reading ± 1 digit. GENERAL AC Input Voltage: Power Consumption: Operating Range: Storage Range: 115VAC ± 14%, 50/60Hz. Installation Category II. 700VA max. 5 C to +40 C, 20% to 80% RH. -40 C to +70 C. Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2. Size: Weight: 210 x 140 x 385mm (W x H x D), half rack width x 3U height (optional rack mounting kit available) 5kg. Safety: Complies with IEC 1010-1 EMC: Complies with EN50081-1 and EN50082-1. www.tenma.com 3

Safety This power supply is a Safety Class I instrument according to IEC classification and has been designed to meet the requirements of IEC 1010-1 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use). It is an Installation Category II instrument intended for operation from a normal single phase supply. This instrument has been tested in accordance with IEC 1010-1 and has been supplied in a safe condition. This instruction manual contains some information and warnings which have to be followed by the user to ensure safe operation and to retain the instrument in a safe condition. This instrument has been designed for indoor use in a Pollution Degree 2 environment in the temperature range 5 C to 40 C, 20% - 80% RH (non-condensing). It may occasionally be subjected to temperatures between +5 C and 10 C without degradation of its safety. Do not operate while condensation is present. Use of this instrument in a manner not specified by these instructions may impair the safety protection provided. Do not operate the instrument outside its rated supply voltages or environmental range. WARNING! THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous. Intentional interruption is prohibited. The protective action must not be negated by the use of an extension cord without a protective conductor. When the instrument is connected to its supply, terminals may be live and opening the covers or removal of parts (except those to which access can be gained by hand) is likely to expose live parts. The apparatus shall be disconnected from all voltage sources before it is opened for any adjustment, replacement, maintenance or repair. Capacitors inside the power supply may still be charged even if the power supply has been disconnected from all voltage sources but will be safely discharged about 10 minutes after switching off power. Any adjustment, maintenance and repair of the opened instrument under voltage shall be avoided as far as possible and, if inevitable, shall be carried out only by a skilled person who is aware of the hazard involved. If the instrument is clearly defective, has been subject to mechanical damage, excessive moisture or chemical corrosion the safety protection may be impaired and the apparatus should be withdrawn from use and returned for checking and repair. Make sure that only fuses with the required rated current and of the specified type are used for replacement. The use of makeshift fuses and the short-circuiting of fuse holders is prohibited. Do not wet the instrument when cleaning it. The following symbols are used on the instrument and in this manual:- Earth (ground) terminal. mains supply OFF. l mains supply ON. alternating current (ac) direct current (dc) 4 www.tenma.com

Emissions Immunity EMC This power supply has been designed to meet the requirements of the European EMC Directive 89/336/EEC. Compliance was demonstrated by meeting the test limits of the following standards: EN50081-1 (1992) Generic emission standard for residential commercial and light industry. Test methods and limits used were: a) EN55022 Conducted, Class B b) EN55022 Radiated, Class B EN50082-1 (1992) Generic immunity standard for residential, commercial and light industry. Test methods and limits used were: a) EN60801-2 (1993) Electrostatic Discharge, 8kV air discharge. b) IEC801-3 (1984) RF Field, 3V/m. c) IEC801-4 (1988) Fast Transient, 1kV peak (AC line) and 0 5kV peak (DC output). Cautions To ensure continued compliance with the EMC directive the following precautions should be observed: a) after opening the case for any reason ensure that all signal and ground connections are remade correctly before replacing the cover. Always ensure all case screws are correctly refitted and tightened. b) In the event of part replacement becoming necessary, only use components of an identical type, see the Service Manual. www.tenma.com 5

Mains Operating Voltage Mains Lead Mounting Ventilation Installation This instrument operates from a nominal 115V mains. Check that the local supply meets the AC Input requirement given in the Specification. WARNING! THIS APPARATUS MUST BE EARTHED. Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous. Intentional interruption is prohibited. This instrument is suitable both for bench use and rack mounting. It is delivered with feet for bench mounting. The front feet include a tilt mechanism for optimal panel angle. A rack kit for mounting one or two of these Half-width 3U high units in a 19 rack is available from the Manufacturers. These instruments are very efficient but nevertheless can generate significant heat at full power. The supplies rely on convection cooling only and it is therefore important that ventilation is never restricted if performance and safety are to be maintained. If the supplies are mounted in a restricted space, eg. a 19 inch rack, then adequate ventilation must be ensured by using, for example, a fan tray. Connections The load should be connected to the positive (red) and negative (black) front panel OUTPUT terminals. These safety terminals will accept 4mm plugs, bare-ended wires or spade terminals without exposing any metal parts and are rated to 30A. The load can alternatively be connected to the rear panel OUTPUT screw terminals where the SENSE connections are also located. Refer to the Connection to the Load section in the Operation chapter for full details. The terminal marked is connected to the chassis and safety earth ground. 6 www.tenma.com

Operation Output Setting With the POWER switch on (l) and the OUTPUT push-button switch off (out) the output voltage and current limit can be accurately set using the three output controls; the left-hand meter indicates set voltage and the right-hand meter set current. When the OUTPUT is switched on, the ON LED and the CV (constant voltage) LED will light; the left-hand meter continues to show the set voltage but the right-hand meter now shows actual current drawn. Alternate presses of the I METER DAMPING button will switch current meter damping in and out; with damping switched in the DAMPED LED will be lit and the average value of a varying load current will be read. If the output goes into current limit the CI (constant current) LED will light instead of the CV LED and the left-hand meter will now show the actual voltage at the output terminals; the right-hand meter will continue to show the set current limit. At any time, the set voltage and set current levels can be reviewed by pressing the CHECK V/I button. Outputs from several supplies may be connected in series or parallel to produce higher voltages or higher currents respectively. Care must be taken when connecting supplies in series to ensure that the maximum voltage rating of any output terminal (300V peak maximum with respect to true ground) is not exceeded. Connection to the Load Connection to the front panel output terminals can be made with 4mm plugs, spade terminals or wire ends. To minimise voltage drop, the connecting leads to the load should be of an adequate wire gauge and be kept short. Load wires should also be twisted together to minimise inductance. To overcome errors introduced by connecting lead resistance at higher currents the remote sensing facility should be used (10 mω of lead resistance will drop 0.2 Volt at 20 Amps). Remove the two shorting links made between the rear output and sense terminals and connect the sense terminals directly to the load; the power connections may be made from either the front or the rear terminals. To ensure good coupling between the output and sense, the sense wires should be twisted with their corresponding output leads before the output leads are twisted together. The voltage drop in each output lead must not exceed 1 Volt. The shorting links should be re-made between the rear sense and output terminals when remote sensing is not being used. However, the sense connection is also made internally through a low value resistor and only a small error between the set and actual voltage will result if the links are left disconnected. The output is fully floating and either terminal can be connected to ground or raised by up to 300V peak above true ground; however, such voltages are hazardous and great care should be taken. The current limit control can be set to limit the continuous output current to levels down to 10mA. However, in common with all precision bench power supplies, a capacitor is connected across the output to maintain stability and good transient response. This capacitor charges to the output voltage, and short circuiting of the output will produce a short current pulse as the capacitor discharges which is independent of the current limit setting. www.tenma.com 7

Protection Overvoltage protection (OVP) is fully variable within the range 10% to 110% of the supply's maximum output level. The OVP limit is set via the screwdriver adjustable SET OVP preset potentiometer, accessible through a hole in the front panel. Rotating the preset clockwise increases the limit, which can be read directly on the left-hand display by pressing the READ OVP button. If the voltage on the output exceeds the set OVP for any reason, including an externally forced voltage, the output will be tripped off. The output will also be tripped off if the thermal sensing detects overheating of any of the power semiconductors, or if the sense wires are wired to the wrong output or if an attempt is made to draw power from the sense wires. In all the above cases, the 'TRIP' message will be shown in both displays. Once the cause of the trip has been removed, normal operation can be restored by switching the POWER switch off ( ) then on (l) again. The output is protected from reverse voltages by a diode; the continuous reverse current must not exceed 3 Amps, although transients can be much higher. Maintenance and Repair For service repair and calibration please contact your local Tenma distributor or go to www.tenma.com Fuse The correct fuse type is: 10 Amp 250V HBC time-lag, 5 x 20 mm Make sure that only fuses with the required rated current and of the specified type are used for replacement. The use of makeshift fuses and the short-circuiting of fuse-holders is prohibited. To replace the fuse, first disconnect the instrument from the AC supply. Remove the 6 cover securing screws and lift off the cover. Replace the fuse with one of the correct type and refit the cover. Note that the main function of the fuse is to make the instrument safe and limit damage in the event of failure of one of the switching devices. If a fuse fails it is therefore very likely that the replacement will also blow, because the supply has developed a fault; in such circumstances the instrument will need to be returned to the manufacturer for service. Cleaning If the PSU requires cleaning use a cloth that is only lightly dampened with water or a mild detergent. Polish the display window with a soft dry cloth. WARNING! TO AVOID ELECTRIC SHOCK, OR DAMAGE TO THE PSU, NEVER ALLOW WATER TO GET INSIDE THE CASE. TO AVOID DAMAGE TO THE CASE OR DISPLAY WINDOW NEVER CLEAN WITH SOLVENTS. 8 www.tenma.com

TEST EQUIPMENT 405 Pioneer Blvd. Springboro, Ohio 45066 Book Part No. 48511-0440 Issue 2