Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

Similar documents
Installation, Operation & Maintenance Manual Model 2596 Self-Cleaning Strainer Cast 10 to 16 and Fabricated 10 to 36

Hydraulic & Lubrication Systems Hydraulic & Lubrication Filters Condition Monitoring Hydraulic Filter Accessories

SPC-PANEL Simplex, Single Phase Pump Control Panel

Manual Transfer Switch

Series 774 Automatic Skid Package

Updated: October 2012

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

SECTION H3 TRAYMASTER SERIES DEAERATORS

Deep Well Pump Control Valve

Pump Installation and Service Manual HRS Hydromatic Retractable System

2-Way Motorized Valves

Series TSW Sheet No J. SUCTION FILTER, horizontal tank mounted. Dimensions: mounting surface

Motorized Tempering Valves with Transformers for

Filtration Solutions. Cover subheadline. Engineered for performance and value in a variety of applications.

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

AccessoriesAccessories

General Installation Instructions for Valves and Gates

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

Model LA 4400 Time Delay OFF Controller

WARRANTY INFORMATION...

Automatic Self-Cleaning Strainer/Filter Systems

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

Eaton Filtration, LLC

MOTORTRONICS Solid State AC Motor Control

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MityFlex Peristaltic Pump

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

INSTALLATION AND OPERATING MANUAL

Motorized Stainless 2-Way Valves

SECTION H4 BOILERMATE DEAERATORS

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

SOLENOID CONTROL VALVE

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

SAMPLE SPECIFICATIONS

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

INSTALLATION AND OPERATING MANUAL

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

Series. idrive 300. Installation and User s Guide INTELLIGENT ENVIRONMENTAL CONTROL. March 2014 v1.1 Edition Copyright 2014 Corporation

Wind Power Solutions Internormen Product Line. Lubrication Systems, Filter Systems, and Accessories for Wind Power Gears

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

Nor East. Instructions. Safety Messages. Inspection. Parts Nor East Controls. Service. Type 05 Air-O-Motor Actuator Used With Globe Valves

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

LCN 7900 SERIES CONTROL BOXES

DC to AC Power Inverters

DC to AC Power Inverters

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve. Steam Solenoid Valve. 1 of 32

Two Channel Remote Shutdown Device

UV DISINFECTION UNIT MODEL 3G

Actuated Valves PRICING

DeZURIK KUL KNIFE GATE VALVES

Automated I.V. Stand Cat. No OPERATOR S MANUAL. Operation& Maintenance Instructions. Raising the Standard of Care!

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

NECO Pumping Systems

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

MODELS CX10 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL

FHC-1D user manual. Features

MC2500. Installation and Operation Manual

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

January 2016 GLOBE VALVES MIXING & DIVERTING SERIES 8600 MODEL Previously manufactured by Dezurik and Honeywell

MODEL I-900 SCRAPER INDEX

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø

D-Series Blowers and Exhausters

Model LA 4100 Time Delay OFF Controller

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Model C230 Pump Controller

ValveMate 7000 Controller Operating Manual

Intelligent Flap Controller

Utility Controller Hand Air Operated

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

User Guide. Model Insulation Tester / Megohmmeter. Introduction

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

HS593 Feed Line Control Unit 230V Single Phase

INSTALLATION AND OPERATING

Automatic Butter Dispenser Instruction Manual Model #2395NS

User s Manual D-Series Blowers and Exhausters

BMRX Series ROTARY LEVEL CONTROL

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

TITAN FLOW CONTROL, INC.

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

Electric Actuators Maximum in-lbs

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Model LA 4300 Time Delay OFF Controller

Transcription:

Read all the following information and instructions prior to installing and operating the equipment. Failure to comply with these instructions could result in bodily injury or property damage. TABLE OF CONTENTS Introduction... 1 Receiving, Handling, and Inspection... 2 Storage... 2 Operating Modes... 2 Continuous Backwash... 2 Automatic Backwash (Timed Cycle)... 2 Valves... 2 Valve Selection... 2 Backwash/Blow-Down/Drain Valve... 3 Electric Actuators... 3 Pneumatic Actuators... 3 Differential Pressure Switches... 4 Switch Description... 4 Mounting, Piping and Wiring... 4 Adjustment... 4 Control Panel... 5 Description... 5 Cycle Time Sequence... 5 Standard Features... 5 Diagrams... 6-7 Electrical Schematic Diagram... 6 Typical Piping and Wiring Diagram... 7 Typical Installation... 8 INTRODUCTION An automatic, self-cleaning strainer requires a control system to provide flexibility and optimize performance of the straining operation. A number of standard options are available or specify a custom designed control system. This manual will define the installation requirement, operation, and maintenance of the Eaton control system. IOM Controls 04/2013 REV A. Page 1 of 8

RECEIVING, HANDLING AND INSPECTION The control panel, backwash arm and motor and accessories have been packed in a separate container but shipped with the strainer. This provides protection from damage during transit and also provides for ease of storage if the controls are not installed immediately. When first received the following must be done: 1. Unpack and inspect for damage. 2. Report any damage to carrier immediately. 3. If controls are not installed at this time, refer to Storage Instructions. STORAGE INSTRUCTIONS Repack all components in the original carton and reuse all protective packaging. Store all components in an indoor, clean, and dry environment. Protect from temperature extremes. Mark cartons to protect from handling abuse. STRAINER MODE OF OPERATION CONTINUOUS BACKWASH This is the most effective way to keep the strainer element clean and have the least pressure loss. Continuous element washing can be accomplished with a minimum of control devices. However, it offers no flexibility of operation when there are significant changes in flow volume or solids content of the fluid. The drain line requires a blow-down/drain valve which may be manually operated. Normal valve position is CLOSED. The backwash line requires a backwash valve which may be manually operated on the backwash line. Normal valve position is FULL OPEN. The backwash motor requires a motor starter. Furnish with overload protection and fused disconnect. STRAINER MODE OF OPERATION AUTOMATIC BACKWASH (TIMED CYCLE) The preferred mode of operation for a self-cleaning strainer is one where the control system will permit both intermittent and continuous backwash as required by operating conditions. The drain line requires a blow-down/drain valve which may be manually operated. Normal valve position is CLOSED. The backwash line requires a backwash valve, either electrically or pneumatically operated on the backwash line. This valve should operate only in the FULL OPEN or FULL CLOSED position. A fully adjustable differential pressure switch is furnished to detect the increase of pressure across the strainer. It will activate a backwash cycle independent of the time-controlled sequence. NOTE: Set switch at 2psi over the observed clean pressure drop. Eaton provides a control panel, containing all necessary relays, timers, lights, switches, etc. This will initiate and monitor the intermittent backwash cycles. VALVE SELECTION Several important factors to consider when selecting the necessary valves. Valve Type: Gate, plug, and butterfly valves can be used. However, ball valves provide the most advantages. Ball valves, when Full Open provide a uniform and straight flow path minimizing pressure loss. Since only 90 rotation of the stem is required to go from Fully Closed to Fully Open motorized operators are easily adapted and provide short cycle times. Valve Material: Iron, bronze, steel, and stainless steel are the most common. Select valve and trim material that will not corrode or react with the process fluid or the environment. Pressure Rating: Select the valve class with a pressure rating equal to or greater than the system design pressure. Connection: Select a valve with end connections (flanged, threaded, etc.) that will provide ease of maintenance and trouble-free service. IOM Controls 04/2013 REV A. Page 2 of 8

STRAINER MODE OF OPERATION CONTINUOUS BACKWASH Several valves are required for various applications. Ball valves of the proper size, end connection, material, and pressure rating are recommended for these services. Manually operated valves are best suited for blow-down and chamber drain service. They may also be used for continuous backwash service. For timed cycle backwash, the valve should be operated by an electric or pneumatic valve actuator. Larger size strainers require both a blow-down drain and a chamber drain for the body. The table below lists the service functions and sizes of valves for standard strainers. Model 596 Size Backwash Chamber Drain 2, 3, 4 1 ¾ 6, 8 1 ½ ¾ Model 2596 Size Backwash Chamber Drain 10 to 16 1 ¾ 18 to 30 3 2 36 6 3 PNEUMATIC ACTUATORS A double-acting piston design that uses a clean air supply of 40-125 psi pressure, powers the actuator properly. Using an electric signal, a solenoid pilot valve controls the air supply to the actuator. Most actuators have pipe thread connections (NPT) located so that the solenoid valves may be mounted with minimal tubing runs. Customer must run wiring and conduit from the control panel terminals to the solenoid valve (see Fig 2). Piping (or tubing) is required from the solenoid valve to the air supply system (this is customer scope of supply). The solenoid pilot valve must be piped to the actuator so that the backwash valve will close when there is no electric power to the solenoid. SAMPLE OPERATION USING 3-WAY SOLENOID VALVE Power On: Air supply from the pilot valve to actuator is Open but vent is Closed. Power Off: Air supply to actuator is Closed. Vent connection is Open. ELECTRIC ACTUATORS The required actuator size depends on the backwash valve torque requirements. The motors are shaded pole or split capacitor type. 115 VAC, 10 Hz actuator motors are standard, other voltages are available. The standard actuators require simple wiring from the control panel to the actuator (see Fig 2). IOM Controls 04/2013 REV A. Page 3 of 8

DIFFERENTIAL PRESSURE SWITCHES SWITCH DESCRIPTION (SINGLE OR DUAL ELEMENT) A diaphragm type differential control with single switch is standard. It initiates a backwash cycle whenever a high differential pressure drop occurs across the strainer. A dual element switch is optional where operation requires the first switch to initiate the backwash cycle. The second switch activates on further increasing differential pressure and energizes a visual or audible alarm, calling for operator assistance. DIFFERENTIAL PRESSURE SWITCHES The differential pressure switch easily mounts on the control panel supports or attached to a bracket that is welded to the strainer body. CAUTION: Never drill into the strainer body to mount instrumentation or support brackets. CAUTION: Welding brackets to cast iron units is not recommended and should be avoided. DIFFERENTIAL SWITCH ADJUSTMENT While it is possible to use other equipment than what is described below, any installation should have the items described here. Equipment to be furnished by customer: 2 calibrated pressure gauges 2 gauge valves with drain 2 tees, tubing, and fittings All items suitable for 1/4 NPT connections Install all equipment as shown in Fig 1. Open the gauge valves and record the pressure readings at inlet/discharge of strainer operating at rated flow. The difference in reading is the Normal pressure drop across the system. Close both gauge valves. Set switch at Normal Plus 2 psi using the adjustment screw at the calibrated scale. To simulate a high differential pressure, carefully vent the outlet side gauge valve only. Note the pressure difference at which the switch is activated. Using the adjustment screw on top of the switch, adjust until switch activates at the proper set point. The High alarm setting (optional) should be set at Normal Plus 4 psi. Special applications may require other settings than those given above. Switch should be re-calibrated at least every 6 months. The switch is piped to the pressure connections furnished on the inlet/discharge nozzles of the strainer as shown in Fig 1. Customer must supply and run wiring and conduit between the differential pressure switch and the control panel. See Fig 2 for wiring connections. IOM Controls 04/2013 REV A. Page 4 of 8

CONTROL PANEL DESCRIPTION The ACS Series Control Panel is a rugged electro-mechanical unit made with industrial grade components and suitable of outdoor (NENA 4) installation. The enclosure houses all components, is compact in size (12 x 12 x 7 3/8 ) and is offered in three configurations: ACS-I: Basic, standard requires 120VAC input. All auxiliary equipment furnished by others. ASC-II: All standard features and includes motor and starter for backwash arm. ASC-III: All standard features plus motor starter for backwash motor and transformer for 575V, 460V or 220V The ACS line of control panels allows operation either in the Manual or Auto modes. In the Manual mode, the strainer will continuously backwash. In the Auto mode, the strainer is allowed to backwash according to the preset timing cycle or when the differential pressure switch is activated. NOTE: The customer determines the timing cycle length and changes it as required. The control logic protects the strainer from sudden high quantities of solids or an improperly adjusted timer cycle. Whenever the differential pressure switch is activated, it overrides the timer circuit and opens the backwash valve. NOTE: An On-Off cycling of the backwash valve will occur. If frequent activation of the differential pressure switch is evident, the timer cycle must be re-set to backwash more often. The panel door locates the selector switch and the indicating lights. The weatherproof rating is maintained as long as the lamp lenses are not broken and are not removed. CYCLE TIMER SEQUENCE To aid in understanding the electrical schematic (See Fig 2), the following description and definitions are provided: Switching ON: B/W valve is closed Switching OFF: B/W valve is open Place the selector switch in the Auto position. This energizes the coil of the timer relay (TR1) and starts the countdown of its off delay cycle. Because (TR1) contacts have not changed position, the backwash valve remains open. When point (t2) is reached, the delay cycle has just expired and relay (TR1) contacts change position and the close circuit to the backwash valve is energized. Therefore, the B/W valve closes. During the time period (t2-t3) the valve remains closed. At point (t3), the relay contacts change position again and the B/W valve opens. For period (t3-t4), the backwash continues. At point (t4) the relay contacts change position and the B/W valve closes. Now at point (t5) the differential pressure switch activates. Through the control relay (CR- 1) the coil of timer relay (TR1) is deenergized. The (TR1) contacts change position and the B/W valve opens. Period (t1-t12) and (t3-t4) may last from 30 seconds to 10 plus minutes; period is customer adjustable. Period (t2- t3) and (t4- t5) may last from 10 minutes to 16 plus hours. This period is customer adjustable. ACS Panels include the following Standard Features: Solid State Timer Relay, fully adjustable knob control for both on and off cycles. Off Delay (backwash): 30 to 600 seconds. On Delay (no backwash): 10 to 1000 minutes. Control Relay rated for 10 amps, DPDT contacts, plug-in type connection provides over-ride control and customer alarm signal contacts. 3 Position Selector Switch for mode selection (off-on-auto) 3 Indication Lights, red: high differential pressure, amber: unit is backwashing, green: power is on. Differential Pressure Override protects strainer from unusual high solids loading and incorrectly set wash cycles. Fuse Protected Panel Circuits, All components protected from overload. Fuse rating is 2.3 amps (ACS-3 panel) and 3.0 amps (others). Control circuit writing Power circuit wiring: 18 gauge 14 gauge IOM Controls 04/2013 REV A. Page 5 of 8

IOM Controls 04/2013 REV A. Page 6 of 8

IOM Controls 04/2013 REV A. Page 7 of 8

TYPICAL INSTALLATION North America HQ 44 Apple Street Tinton Falls, NJ 07724 Toll Free: (800) 656-3344 (North America only) Voice: +1 732 212-4700 Brazil Av. Julia Gaioli, 474 Bonsucesso 07251-500 Guarulhos Brazil Voice: +55 11 2465 8822 Singapore 4 Loyang Lane #04-01/02 Singapore 508914 Voice: +65 6825 1668 WARRANTY For more information, please e-mail us at filtrationinfo@eaton.com or call 732-212-4700. Europe/Africa/Middle East Auf der Heide 2 53947 Nettersheim, Germany Voice: +49 2486 809 0 China No.7, Lane 280, Linhong Road Changning District, Shanghai 200335, China Voice: +86 21 5200 0422 All products manufactured by Seller are warranted against defects in material and workmanship under normal use and service for which such products were designed for a period of eighteen (18) months after shipment from our factory or twelve (12) months after start-up, whichever comes first. OUR SOLE OBLIGATION UNDER THIS WARRANTY IS TO REPAIR OR REPLACE, AT OUR OPTION, ANY PRODUCT OR ANY PART OR PARTS THEREOF FOUND TO BE DEFECTIVE. SELLER MAKES NO OTHER REPRESENTATION OR WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. WE SHALL NOT BE LIABLE FOR CARTAGE, LABOR, CONSEQUENTIAL DAMAGES OR CONTINGENT LIABILITIES. OUR MAXIMUM LIABILITY SHALL NOT IN ANY EVENT EXCEED THE CONTRACT PRICE FOR THE PRODUCT. IOM Controls 04/2013 REV A. Page 8 of 8