Operating manual for

Similar documents
Operating Manual for Automatic sprayvalve KA-2 / GT

Operating manual for Mini-Automatic sprayvalve MMFS

Operating Manual for sprayvalve MKDD-IS

Operating Manual for extrusion valve MMKD-40 KV/LV/LVP

Operating Manual for FINE-SPRAY gun W 3/FZ-Duo

Range of Products SPRAYTECHNOLOGY

Assembly Instructions

Service Handbook HD /97

AUTOMATIC AIRSPRAY GUN

Pro Gun (Model: UCpro and UCPro Plus)

Operation Manual Cobra 1 Automatic Spray Gun

MACH 1A HVLP (MACH 1AV HVLP) Automatic Airspray Gun

Operation Manual BINKS 460 Automatic Spray Gun

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

Operating manual GA 250AL GA 400AL. Edition 07 / Automatic Airless Spraygun. II 2GX (Atex 95)

Operation Manual GTi Pressure Feed Spraygun

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se


#9040 FUEL TANK SWEEPER

Installation and maintenance guide

Operation Manual GTi Pressure Feed Spraygun

Air operated chassis pump

Safety, Operation and Maintenance Instructions For Long & Short Nose Upholstery Air Stapler (NS10 & NS11)

Pressure relief valve

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

A408 GB. Pneumatic oil and diesel pumps 1:1

Operation Manual Advanced - Conventional Gravity Feed Spraygun

USE and MAINTENANCE INSTRUCTION MANUAL W-300 W-300 WB LPH-300 GRAVITY. SPRAY GUN Series. en it fr es pt de se

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

High-performance automatic spray gun AGMD

OPERATING MANUAL LA-BO. Applicator

Pressure and flow regulating valve, Type B-PRO

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT

LINE PAINT SPRAY GUN VERFPISTOOL INSTRUCTION MANUAL HANDLEIDING FAT-0111 FAT-0111 EN NL. Zhong Nan Trading CO., Gompertsstraat nr.

Installation and maintenance guide

GRAVITY FEED SPRAY GUN & CUP SPECIFICATIONS. Operating Instructions Warning Information Parts Breakdown. Fluid Orifice mm. Air Inlet:...

ATD PIECE HVLP SPRAY GUN SET INSTRUCTION MANUAL

ATD MM TOUCH UP GUN W/CUP INSTRUCTION MANUAL

Model No. SP Low Volume Low Pressure (LVLP) Gravity Feed Spray Gun

Pneumatic atomizing nozzles ViscoMist flat fan, external mix Series 176

Stub pump 3:1. User and maintenance instructions. Models and , series D. Date of issue December Form number

Operating Manual. Automatic spray gun AGR-09 mini, AGR-09 mini with needle stroke limitation for low-pressure atomization


NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

1 MECHANICAL FUEL METER

EASY!Force trigger gun, rotary knob, spray lance, PowerControl spray lance Service Manual

ATD MM PRIMER GUN W/CUP INSTRUCTION MANUAL

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Installation, Operation, and Maintenance Manual

Marking Systems. Paint Spray Systems Marking Blocks Paints & Inks

Hydraulic Rotary Hammer Drill

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

EasySelect-Cup Manual Powder Gun

LP 9-20 E PAC. Crowder Supply Co., Inc Roslyn St., Commerce City, CO Toll Free:

PNEUMATIC SLIDING VALVE

Angle seat valve with piston actuator VZXA-...-K

PG 2-A Automatic Powder Gun (and PG 2-AX Automatic Powder Gun for Quick Colour Changes)

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

Schütze automatic valves and guns:

Operation Manual FLG-S5-18 Transtech Suction-feed Spray Gun

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Operating instructions Rescue equipment. Mobile Selection Manifold MSM-2D PN500 - STREAM GB Issue

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

OPERATION MANUAL FLG-G5-14 Transtech Gravity Spraygun

basic quattro No /

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

B14 AAA FINE FINISH SERIES PUMP OUTFIT

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

SB-E ISS.05. Operation Manual AA4400A Automatic Air Assisted Airless Spray Gun

Techcon Systems TS5540-MS Micro Spray Valves

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE

Pneumatic grease pump 50:1 and grease supply system

USER S GUIDE HIGH INTENSITY ULTRASONIC PROCESSOR

INSTRUCTION MANUAL ASI 24 AND ASI 40 AIRLESS GUN STAINLESS STEEL MODEL

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions and Spare Parts List. PG 1-Cup Gun. Issued 09/98

D Instructions/Parts. Siphon Feed Detail Spray Gun D

Exchange of rollers from the XTS-Mover

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Installation manual wall-mounted distributor

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

IOM Manual. IOM Manual. Series 20/21.

781Mini Series Spray Valve

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

PRODUCT MANUAL 12ST (V.4.0) 12ST FS (V.2.0.F) RON-WPM ST/12STFS-Rev.3

AirCoat Automatic spray gun. Translation of the original Operating manual GA 3000ACIC GA 3000ACIC S GA 3000ACIC UV GA 3000ACIC UV G GA 3000ACIC S UV G

Paint/Solvent/Dump Valve and Flow-Through Valve

01 / Pralinenfix PFM 2000

Translation of the original Operating manual GM 3000AC. Edition 05/2007. AirCoat spray gun with flat or round jet nozzles.

Cross Reference Air Caps Guide

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

PG 1-A Automatic Powder Gun

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Transcription:

Operating manual for automaticspray valve ASV Read this manual carefully before installing, operating or servicing this equipment.

Keep always handy for further use. ALFRED SCHÜTZE Apparatebau GmbH - Spritztechnik Spraytechnology - Hannoversche Straße 69-71, 28309 Bremen Germany; Postfach 44 86 48, 28286 Bremen - Germany Tel.: 0049 (0)421 / 43510-0; Fax: 0049 (0)421 / 43510-43 Internet: http://www.schuetze-gmbh.de E-Mail: info@schuetze-gmbh.de

1 Introduction The automatic spray valve ASV is designed and constructed for application of thin materials f.i. release agents, oils, colours and in version KLS also for glues and adhesives. Depending on position of continuously adjustable regulation of sprayjet, this spray valve sprays from round- to 90 flatspray. Depending on viscosity of fluid, the application can be adjusted individually via nozzle dimension, atomizing air pressure, material pressure and the continuously adjustable sprayjet regulation. The supply of atomizing air, control air and material should be done via three hoses (with remote-controlled regulation of sprayjet = four hoses). Spray valves are precision tools. Always keep clean and observe minimum instructions to maintain a long useful life of the valve. 2 Safety 2.1 Duties of the user The user must read this service manual carefully before performing any operations. Application and service operations should not be carried out if the user is not absolutely sure of the purpose and consequence of the operations. 2.2 Definitive Use The automatic spray valve ASV is a pneumatically controlled needle valve. It is suitable for continuously or intermittent use. They are not suitable for spraying aggressive fluids like acid, alkaline solutions, cleaning agents, chemicals etc.. In case of doubt, please contact the manufacturer. 2.3 Warning against danger This operating manual warns users of operations which may put their health at risk. The warnings are indicated by combinations of text and symbols corresponding to the different danger classes. WARNING! Signs a possible dangerous situation. If you don t avoid, death or severe injuries can follow. CAUTION! Indicates a situation which may be dangerous. Failure to heed the caution may result in personal injury. This indication is also used where material damage is possible. IMPORTANT! Indicates tips for usage and other helpful information. 3 Function Description The automatic spray valve ASV is pneumatically controlled: air open; spring return. The spraying material is to be fed to the valve via pressure tank or pump. The separate controlled atomizing air atomizes the material to a spray jet. Depending on position of continuously adjustable sprayjet regulation, the valve sprays from a round- up to a 90 flatspray. 4 Installation The automatic spray valve ASV can be installed in any position. For solid attachment the use of clamp (option, drawing no.: 15.0) is recommend. Vibration of the equipped machine to the valve should be limited as far as possible. Vibrations of the valve caused by fast intermitting cycles require solid and massive installation.

4.1 Hose connection and assembly Connect hoses for atomizing air and control air to seperatly control valves (pressure reducers and solenoids). Then fluidhose to material pressure tank or other means of feeding fluid as under: atomizing air, marked with Z (draw.-no.: 6.0, hose blue): to 2/2 way solenoid control air, marked with S (draw.-no.: 6.0, hose black): to 3/2 way solenoid fluid, marked with M (draw.-no.: 6.0, hose transparent): to feeding device OPTIONAL: remote-controlled regulation of sprayjet, (draw.-no.: 16.0, hose blue): to 2/2 way solenoid material circulation, (draw.-no.: 6.0, hose black): back to feeding device 4.2 Spray pattern regulation Turn the spray pattern regulator (7.0) to adjust the spray pattern. Turn anti-clockwise for a wider jet spray and clockwise for a rounder spray. The adjustment is continuous, not in steps. Optionally the spray pattern regulation can be done pneumatically controlled. For this option turn spray pattern regulator (7.0) clockwise completely. Now the regulation of atomizing air for the cone holes can be done via additional air connection M5 (16.0) via pressure regulator remote-controlled. 4.3 Operating instructions CAUTION! Never point the sprayjet against persons. Wearing eye protection is strongly recommended. Spraying procedures cause noises depending on the used pressure. If necessary, wearing of ear protection is recommend. WARNING! Danger caused by combustible and noxious spraying material. Safety instructions on fluid can and material data of fluid manufacturer must definitely be observed. The automatic spray valve ASV needs 3,5 6 bar control air pressure. Atomizing air pressure and material pressure should be as low as possible. In any case, please observe the regulations of the professional/trade association having liability for industrial safety and insurance. When you are certain, that fluid pressure stands up to the nozzle, actuate 2/2 way solenoid for atomizing air. After that actuate 3/2 way solenoid for control air. This way you reveive socalled pre-air prior to opening fluid flow. After each cycle solenoids are to actuate in reverse order, so you will still have purging-air after needle has closed nozzle and fluid flow was stopped. This prevent fluid to form out drops instead of being atomized. Set atomizing air pressure and fluid pressure according to required spray droplet sizes. Two separate pressure reducers must be available. Intermittend use as well as continuous use is possible. Maximal 40 cycles per second are possible (under optimal working conditions). IMPORTANT! The quantity of fluid flow can be adjusted by the regulating knob (draw.-no.: 13.0). Turning this knob in anti-clockwise turn = more fluid flow Turning this knob in clockwise turn = less fluid flow Do not over-tight the regulating knob.

IMPORTANT! To avoid damages to nozzle and needle adjust decrease of fluid flow (turning regulating knob 16.0 clockwise) only when fluid is emitted from the nozzle. This is the only way to observe the steady reduction of fluid flow until an absolute stop of fluid. Going on to turn the regulating knob clockwise would at once push the needle into the nozzle to such an extant that both parts could be damages. It is harmless to leave fluid within the valve (no connection to outside air), if system stays under pressure. 5 Repair and Maintance Before starting maintenance or repair work, ensure that all air operated tools are disconnected from the air supply. WARNING! Danger caused by combustible and noxious spraying material. Safety instructions on fluid can and material data of fluid manufacturer must definitly be observed. WARNING! Before opening the spray valve it has to be disconnected from the air and fluid supply. Otherwise ejected elements can cause danger. The automatic spray valve ASV is a high precision tool. Always keep clean and observe minimum instructions to maintain a long and useful life of valve. We recommend lubricating moveable parts regularly, and greasing threads, especially the nozzle threads, when replacing or cleaning the nozzle. It is recommended to use clean and filtered application fluid only. Also atomizing air should be clean. Control air should be slightly oiled. 5.1 Cleaning To clean valve, spray solvent until pure solvent leaves nozzle. Do not submerge entire valve in solvent. At longer working interruptions it is advisable to clean air cap and nozzle by putting these parts only into solvent. If necessary use a soft brush. Moving parts and threads should alway be greased slightly. The spray valve should be cleaned using an appropiate thinner. To clean small drill holes, use our special nozzle cleaning needles. These spray valves are high precision tools. Always keep clean and observe minimum instructions to maintain a long and useful life of valve. We recommend lubricating moveable parts regularly, and greasing threads, especially the nozzle threads, when replacing or cleaning the nozzle. 5.2 Possible case of failure: Needle sticks Check, if sufficient control / operating air is supplied (3,5-6 bar). Check, if o-ring (9.1) is in propper order. Check, if needle is dirted by f.i. glue residues or sticks within needle gasket (8.1 / 8.4) or within nozzle. Check, if minimum of travel of needle is set. Troube shooting. If drops form on the nozzle, either needle or nozzle is worn out and should be replaced. Or needle is not closing properly f.i. because particle residues within nozzle. If there is an uneven or not steady spray jet, make sure that nozzle is screwed in tight. Other reason could also be dirt residue within air cap. 5.3 Changing the nozzle set IMPORTANT! Nozzles, gaskets and gasket seats can be damaged. Do not use metallical aid to remove and insert those parts.

A nozzle set includes needle (9.0), nozzle (3.0) and air cap (2.0). If nozzle size is to be changed, always change all these three parts. Change the complete set also when only one of the parts is defect. Disconnect all air operated tools from the air supply. Take off closing plate (14.0) by unscrewing screws (12.0). Pull out needle spring (10.0) and needle (9.0). Take off air cap (2.0) after unscrewing collar ring (1.0). Screw out nozzle (3.0) with wrench, size SW 6. Before unscrewing nozzle, please observe that needle is never under spring pressure. Reassemble in reverse order. To prevent damage to the needle seat during replacement, the needle (9.0) must only be inserted into firmly installed nozzle. 5.4 Changing needle gasket IMPORTANT! Gaskets and gasket seats can be damaged. Do not use metallical aid to remove and insert those parts. Before starting maintenance or repair work, ensure that all air operated tools are disconnected from the air supply. Take of closing plate (14.0) by unscrewing screws (12.0). Pull out needle spring (10.0) and needle (9.0). Then unscrew retainer (8.0). After unscrewing retainer (8.0) all o-rings and gaskets (8.1 / 8.2 / 8.4 / 8.5) can be changed. The o-ring (9.1) can be changed from the needle piston. Reassemble in reverse order. approx.50 mm Connection for fluid circulation (OPTION) Clamp (OPTION) 10 Square 30x30 ø20 approx.45 mm 40.5 approx.72.5 mm

6.0 1.0 17.0 16.0 2.0 3.0 15.0 4.0 5.0 18.0 8.1 15.1 15.2 8.2 6.0 8.3 7.1 7.2 8.4 8.5 8.0 7.0 9.0 9.1 14.0 10.0 11.0 14.4 14.2 14.1 14.3 12.0 14.1 14.2 14.3 13.1 13.2 13.0

6. Spareparts list draw.-no.: part-number: Quantity Description 1.0 410028 1 collar ring, ø 23 x 10mm 2.0 * 1 aircap, flatspray, ø 20 x 14,5mm 2.1 * 1 aircap, roundspray, ø 20 x 11mm 3.0 * 1 nozzle, stainless steel, ø 12 x 18mm 4.0 510345 1 valve body ASV, stainless steel, complete 5.0 220300 1 screw, stainless steel, 1/8" 6.0 * 3/4 screw for material and air 7.0 380032 1 regulating screw (round-/flatspray regulation), complete 7.1 380033 1 regulating screw, M6x0,5 x 11mm 7.2 640003 1 o-ring 4 x 1 / Viton 8.0 810054 1 retainer, complete 8.1 640155 1 shaped gasket 3,0 x 2,15 x 1,35 8.2 640317 1 o-ring 7 x 1,5 / Viton 8.3 810053 1 retainer, ø 14,94 x 19,5mm 8.4 640026 1 o-ring 2,9 x 1,78 / Viton 8.5 640316 2 o-ring 13 x 1 / Viton 9.0 * 1 needle, complete 9.1 640007 1 o-ring 14 x 1,78 / Viton 10.0 820076 1 spring 0,9 x 24mm 11.0 320318 1 ratchet screw, ø 13 x 18,5mm 12.0 610055 2 screw DIN 7991 M4 x 10 13.0 320668 1 regulating knob, stainless steel, complete 13.1 320609 1 regulating knob, ø 20 x 9mm, stainless steel 13.2 610034 1 pin DIN 915 M4 x 6 14.0 511021 1 closing plate, complete 14.1 610017 2 pin DIN 913 M3 x 3 14.2 820077 2 spring 0,4 x 5,5mm 14.3 650004 2 ball, stainless steel, ø 2,5mm 14.4 510346 1 closing plate, stainless steel, 30 x 30 x 10,5mm 15.0 910015 1 clamp, complete (OPTION) 15.1 910014 1 clamp, 21,5 x 25 x 15mm 15.2 610042 2 screw DIN 6912 M5 x 14 16.0 220089 1 screw M5, SW8 x 19mm, complete (OPTION) 17.0 610063 1 screw M5, complete with seal 18.0 610249 1 pin DIN 915 M3 x 3 * Please find part-numbers on page 8. When ordering nozzle sets, please specify dimension. Available dimensions: 0,2 / 0,3 / 0,5 / 0,8 / 1,0 / 1,2 / 1,5 / 2,0 / 2,5 mm nozzle set = needle, nozzle and aircap. If nozzle size is to be changed, always change all these three parts. Change the complete set also when only one of the parts is defect.

6.1 part-numbers for needles, nozzles and aircaps *needles *nozzles draw.-no. part.-no. description draw.-no. part-no. description 9.0 110884 0,2/0,3mm 3.0 210110 0,2mm 9.0 110885 0,5mm 3.0 210111 0,3mm 9.0 110886 0,8mm 3.0 210112 0,5mm 9.0 110887 1,0mm 3.0 210113 0,8mm 9.0 110888 1,2mm 3.0 210114 1,0mm 9.0 110889 1,5mm 3.0 210115 1,2mm 9.0 110890 2,0mm 3.0 210116 1,5mm 9.0 110891 2,5mm 3.0 210117 2,0mm 3.0 210118 2,5mm * aircap / flatspray 90 (standard version) draw.-no. part.-no. description 2.0 310238 for nozzle 0,2-1,0mm 2.0 310239 for nozzle 1,2-1,5mm 2.0 310240 for nozzle 1,8-2,0mm 2.0 310241 for nozzle 2,5mm * aircap / flatspray 60 draw.-no. part.-no. description 2.0 310234 for nozzle 0,2-1,0mm 2.0 310235 for nozzle 1,2-1,5mm 2.0 310236 for nozzle 1,8-2,0mm 2.0 310237 for nozzle 2,5mm * aircap / roundspray 15 draw.-no. part-no. description 2.1 310034 for nozzle 0,2-1,0mm 2.1 310035 for nozzle 1,2-1,5mm 2.1 310080 for nozzle 1,8-2,0mm 2.1 310091 for nozzle 2,5mm * screw for material and air draw.-no. part-no. description 6.0 220022 screw with nut SW 13x28mm / 1/8" - 6/4 (standard) 6.0 220243 screw with nut SW 13x28mm / 1/8" - 8/6

7. Technical data measurements = approx. 50mm x 45mm x 72,5mm lenght weight = approx. 305 g air consumption (standard version) = approx. 111 ltr. per minute (3 bar; 0,3 mm nozzle; flatspray aircap; 2m hose length) air consumption (remote-controlled) = approx. 133 ltr. per minute (3 bar; 0,3 mm nozzle; Flatspray aircap; 2m hose length) control air pressure = minimum: 3,5 bar, maximum 6 bar atomizing air pressure = as required material pressure = max. 10 bar Special designs on request. Technical alterations reserved. May 2009. 8. Manufacturer declaration The automatic spray valve ASV is constructed and produced by ALFRED SCHÜTZE Apparatebau GmbH, Hannoversche Straße 69-71, 28309 Bremen Germany in accordance with the guidelines and standards of DIN EN 292. This spray valve can be combined with other modules or machines, which comply to DIN EN 292, without limiting the conformity. Place Date Signature of manufacturer Bremen 29.05.2009