Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Similar documents
DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

Rheem Value Series Downflow Gas Furnace

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Plus Series Downflow Gas Furnace

Table of Contents GF801U Series

Rheem Classic Series Downflow Gas Furnace

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

Rheem Classic Series Upflow/Horizontal Gas Furnace

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Value Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

UPFLOW/ HORIZONTAL GAS FURNACE

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Sample Residence HVAC Load Calculations

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

KG7S (A and K Series)

FG7S (C and L Series)

Rheem High Efficiency Air Handler

KG7T (C and L Series)

Cased/Uncased Coils For Gas And Oil Furnaces

FG7T (A and K Series)

KG7T (E and N Series)

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

FG7T (E and N Series)

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

Cased/Uncased Coils For Gas And Oil Furnaces

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

KG7T (C and L Series)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Ruud High Efficiency Air Handler

G8MVL. Product Specifications

Cased/Uncased Coils For Gas And Oil Furnaces

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

Multi-Position, Multi-Speed Gas Furnaces

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

N9MPD Product Specifications

F8MTL. Product Specifications

FG7T (A and K Series)

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

GMS9/GCS9 SERIES 93% AFUE

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

G9MXE. Product Specifications

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

TSTAT0101SC Recommended (sold separately)

G9MXE. Product Specifications

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

AF90. AF90 Gas Furnace High Efficiency. Features

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

FORM NO. HSC-543 AIR HANDLERS

GKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

GKS9 Series. Upflow Multi-Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

Transcription:

Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. The Rheem Classic Series with Dual Comfort Control line of down flow/hori zontal gas furnaces are designed for utility rooms, closets, alcoves, or attics. The RGTK is shipped in the downflow configuration and is easily converted for horizontal left-hand airflow applications. The design is certified by CSA. Two stages of operation to save energy and maintain optimal comfort level. Furnace operates at 70% capacity for low-heat and 100% capacity for high-heat. Compatible with single or two-stage thermostat. (For optimal performance two-stage thermostat recommended.) Heat exchanger tubular construction is stainless steel for maximum corrosion resistance and thermal fatigue reliability. Low profile 34 inch design is lighter and easier to handle and leaves room for optional accessories. Top electrical connections, left or right side gas, and condensate drainage connections on downflow/horizontal models. Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner. An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. Pre-paint galvanized steel cabinet. Molded permanent filters. Optional indoor or outdoor combustion air. Transformer and control fuse protection. Control board diagnostics. Condensate drain trap for horizontal/downflow application provided standard. A variety of cooling coils and plenums designed to use with the Rheem Classic Series gas furnaces are available as optional accessories for air conditioning models. FORM NO. G11-531

Table of Contents TABLE OF CONTENTS Standard & Optional Equipment...3 Model Features/Physical Data & Specifications...4 Model Number Identification...5 Dimensional Data...6-7 Blower Performance Data...8 Accessories...9 Limited Warranty...10 2

Standard & Optional Equipment DRAFT INDUCER PRIMARY AND SECONDARY HEAT EXCHANGER INTEGRATED FURNACE CONTROL GAS VALVE AND MANIFOLD REMOTE SENSOR PRESSURE SWITCHES DIRECT SPARK IGNITION & REMOTE SENSOR IN-SHOT BURNERS STANDARD EQUIPMENT Completely assembled and wired; heat exchanger; primary: 409 and aluminized 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant main gas control manual shut-off; blower compartment door safety switch; solid state time on/off blower control; limit controls; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; pressure regulator for natural and L.P. (propane) gasses; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.) OPTIONAL EQUIPMENT NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. All models can be converted by a local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 3

Model Features/Physical Data & Specifications Model Features The design is certified by CSA. Two stages of operation to save energy and maintain optimal comfort level. Furnace operates at 70% capacity for low-heat and 100% capacity for high-heat. Compatible with single or two-stage thermostat. (For optimal performance two-stage thermostat recommended.) Heat exchanger tubular construction is stainless steel for maximum corrosion resistance and thermal fatigue reliability. Low profile 34 inch design is lighter and easier to handle and leaves room for optional accessories. Top electrical connections, left or right side gas, and condensate drainage connections on downflow/horizontal models. Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner. An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. Pre-paint galvanized steel cabinet. Molded permanent filters. Optional indoor or outdoor combustion air. Transformer and control fuse protection. Control board diagnostics. Condensate drain trap for horizontal/downflow application provided standard. Physical Data and Specifications Downflow/Horizontal Models U.S. and Canadian Models MODEL NUMBERS RGTK-06*MAES RGTK-07*MAES RGTK-07*YBGS RGTK-09*ZAJS RGTK-10*ZAJS FIRE INPUT BTU/HR [kw] ➀ 60,000 [17.58] 75,000 [21.98] 75,000 [21.98] 90,000 [26.38] 105,000 [30.77] 120,000 [35.17] LOW FIRE INPUT BTU/HR [kw] 42,000 [12.31] 52,500 [15.39] 52,500 [15.39] 63,000 [18.46] 73,500 [21.54] 84,000 [24.62] FIRE HEATING CAPACITY BTU/HR [kw] 56,000 [16.41] 70,000 [20.51] 70,000 [20.51] 84,000 [24.62] 97,000 [28.43] 113,000 [33.12] FIRE ALTITUDE INPUT 8000' 40,800 [11.96] 51,000 [14.95] 51,000 [14.95] 61,200 [17.94] 71,400 [20.93] FIRE ALTITUDE OUTPUT AT 8000' ( FIRE) [kw] BLOWER (D x W) [mm] 37,944 [11.12] 47,430 [13.90] 47,430 [13.90] 56,916 [16.69] 66,402 [19.46] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 12 x 7 [305 x 178] 12 x 11 [305 x 279] 12 x 11 [305 x 279] RGTK-12*RAJS 81,600 [23.91] 75,888 [22.24] 11 x 10 [279 x 254] MOTOR H.P. [W] SPEEDS TYPE 1/2 [373]-4-PSC 1/2 [373]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC MOTOR FULL LOAD AMPS 6.8 6.8 9.5 9.5 9.5 9.5 HEATING SPEED FIRE MED-LO MED-HI MED-LO MED-LO MED-LO MED-HI HEATING SPEED LOW FIRE LOW LOW LOW LOW LOW LOW COOLING SPEED MINIMUM EXT. STATIC PRESSURE (IN. W.C.) [kpa].12 [.029].12 [.029].12 [.029].15 [.037].20 [.049].20 [.049] MAXIMUM EXT. STATIC PRESSURE (IN. W.C.) [kpa].50 [.124].50 [.124].50 [.124].50 [.124].50 [.124].50 [.124] HEATING CFM @.2" [.049 kpa] W.C. E.S.P. [L/s] 885 [418] 1060 [500] 1375 [649] 1400 [661] 1425 [673] 1565 [739] COOLING CFM @.5" [.124 kpa] W.C. E.S.P. [L/s] 1180 [557] 1150 [543] 1625 [767] 1850 [873] 1820 [859] 2040 [963] TEMPERATURE RISE- FIRE RANGE F [ C] TEMPERATURE RISE-LOW FIRE RANGE F [ C] RETURN AIR CABINETS (OPT.) RXGR- FILTER SIZE [mm] STANDARD, VELOCITY PERMANENT FILTER (IN.) 40-70 [22.2-38.9] 30-60 [16.7-33.3] C17B (2) 12" x 20" [305 x 508] 45-75 [25-41.7] 45-75 [25-41.7] C17B (2) 12" x 20" [305 x 508] 35-65 [19.4-36.1] 25-55 [13.9-30.6] C21B (2) 12" x 20" [305 x 508] 45-75 [25-41.7] 35-65 [19.4-36.1] C21B (2) 20" x 20" [508 x 508] 50-80 [27.8-44.4] 35-65 [19.4-36.1] C21B (2) 20" x 20" [508 x 508] APPROX. SHIPPING WEIGHT (LBS.) [kg] 117 [53.1] 123 [55.8] 123 [55.8] 148 [67.1] 152 [68.9] AFUE ➁ 93.8 92.5 93.0 93.2 92.2 NOTES: All models are 115V, 60HZ, 1ø. Gas connection size for all models is 1 /2" [13 mm] N.P.T. ➀ See Index Form for LP Conversion Kits. ➁ In accordance with D.O.E. test procedures. * E = Standard *N=NOx Models 50-80 [27.8-44.4] 45-75 [25-41.7] C24B (2) 24" x 20" [609 x 508] 15 3 /4 x 25 x 1 15 3 /4 x 25 x 1 15 3 /4 x 25 x 1 19 1 /4 x 25 x 1 19 1 /4 x 25 x 1 22 3 /4 x 25 x 1 160 [72.6] 92.4 [ ] Designates Metric Conversions 4

Model Number Identification Model Number Identification R G T K 07E* M A E S Rheem Gas Furnace Downflow/ Horizontal Condensing Gas Furnace Design Series Electric Ignition 06* 07* 09* 10* Heating Input Designation Input BTU/HR 60,000 [17.6 kw] 75,000 [22 kw].6 90,000 [26.4 kw] 105,000 [30.7 kw] 12* NOTES: *E = Standard *N = NO x Models 120,000 [35.2 kw] Blower Size M = 11 x 7 [279 x 178 mm] R = 11 x 10 [279 x 254 mm] Z = 12 x 11 [305 x 279 mm] Y = 12 x 7 [305 x 178 mm] Variations A = Std. B = Wide Cabinet Heat/Cool Designation E = 1100-1300 CFM [519-613.5 L/s] G = 1500-1700 CFM [707.9-802.3 L/s] J = 1900-2100 CFM [896.7-991.1 L/s] Fuel Code S = U.S. and Canadian Natural Gas [ ] Designates Metric Conversions 5

Dimensional Data Downflow Applications 19/32 [15 mm] A B RETURN AIR 19/32 [15 mm] 3/4 [19 mm] D 28 1 /16 [713 mm] 20 1 /8 [511 mm] 19/32 [15 mm] 3/4 [19 mm] 26 9 /16 [678 mm] 24 1 /16 [611 mm] 2 [51 mm] DIA. GAS CONNECTION 34 [664 mm] 25 13 /16 [656 mm] 23 11 /16 [602 mm] 2 [51 mm] ALT. GAS CONNECTION 1 5 /8 [41 mm] DIA. ALT. CONDENSATE DRAIN 4 13 /16 [106 mm] 6 27 /64 [163 mm] 4 13 /16 4 3 /8 [106 mm] [111 mm] 1 5 /8 [41 mm] DIA. CONDENSATE DRAIN LEFT SIDE FRONT RIGHT SIDE NOTE: In downflow configuration, return air cut-out is not permitted. [ ] Designates Metric Conversions 6

Dimensional Data Horizontal Applications 1 5 /8 [41 mm] DIA. 26 9 /16 ALT. CONDENSATE [675 mm] DRAIN 24 1 /16 [611 mm] 2 [51 mm] DIA.GAS CONNECTION 19 7 /8 [505 mm] 4 13 /16 [122 mm] 6 1 /64 [153 mm] TOP 19/32 [15 mm] ELECT. CONN. 1 13 /16 [46 mm] 23 31 /32 [609 mm] 22 3 /32 [561 mm] SUPPLY AIR E B A C F COMBUSTIBLE AIR INLET LOW VOLTAGE VENT OUTLET RETURN AIR 3 LEFT SIDE 7 /16 [87 mm] FRONT 3/4 RIGHT SIDE [19 mm] 19/32 [15 mm] 4 13 /16 [122 mm] 4 3 /8 [111 mm] 34 [864 mm] 3/4 [19 mm] 2 [51 mm] DIA. ALT. GAS CONNECTION 1 5 /8 [41 mm] DIA. CONDENSATE DRAIN 23 11 /16 [602 mm] 25 13 /16 [656 mm] D 20 1 /16 [511 mm] 28 1 /16 [713 mm] Dimensional Data BOTTOM 19/32 [15 mm] NOTE: In downflow configuration, return air cut-out is not permitted. MINIMUM CLEARANCE (IN.) [mm] SHIP MODEL LEFT A B C D E F WGTS. RGTK- SIDE RIGHT BACK TOP FRONT VENT SIDE [kg] 06 17 1 /2 [445] 16 11 /32 [415] 15 5 /8 [397] 2 [51] 16 5 /8 [422] 13 7 /8 [352] 0 0 0 1 [25] 2 [51] 0 117 [53] 07EM 17 1 /2 [445] 16 11 /32 [415] 15 5 /8 [397] 2 [51] 16 5 /8 [422] 13 7 /8 [352] 0 0 0 1 [25] 2 [51] 0 123 [56] 07EY 21 [533] 19 27 /32 [504] 19 3 /16 [486] 2 [51] 20 1 /8 [511] 17 3 /8 [441] 0 0 0 1 [25] 2 [51] 0 123 [56] 09 21 [533] 19 27 /32 [504] 19 3 /16 [486] 2 [51] 20 1 /8 [511] 17 3 /8 [441] 0 0 0 1 [25] 2 [51] 0 148 [67] 10 21 [533] 19 27 /32 [504] 19 3 /16 [486] 2 [51] 20 1 /8 [511] 17 3 /8 [441] 0 0 0 1 [25] 2 [51] 0 152 [69] 12 24 1 /2 [622] 23 11 /32 [593] 22 5 /8 [575] 2 [51] 23 5 /8 [600] 20 7 /8 [530] 0 0 0 1 [25] 2 [51] 0 160 [73] IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions. [ ] Designates Metric Conversions 7

Blower Performance Data Blower Performance Data MODEL RGTK- 06 07EM 07EY 09 10 12 BLOWER SIZE IN. [mm] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 12 x 7 [305 x 178] 12 x 11 [305 x 279] 12 x 11 [305 x 279] 11 x 10 [279 x 254] MOTOR H.P. [W] 1/2 [373] 1/2 [373] 3/4 [559] 3/4 [559] 3/4 [559] 3/4 [559] BLOWER SPEED LOW MED-L0 MED-HI LOW MED-L0 MED-HI LOW MED-L0 MED-HI LOW MED-L0 MED-HI LOW MED-L0 MED-HI LOW MED-L0 MED-HI CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kpa] 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 795 [375] 910 [429] 1115 [526] 1365 [644] 780 [368] 890 [420] 1100 [519] 1340 [632] 1185 [559] 1405 [663] 1595 [753] 1835 [666] 1155 [545] 1420 [670] 1605 [757] 2005 [946] 1180 [557] 1460 [689] 1680 [793] 2055 [970] 1285 [606] 1590 [750] 1840 [868] 2315 [1093] 760 [359] 885 [418] 1080 [510] 1315 [620] 750 [354] 860 [406] 1060 [500] 1295 [611] 1160 [547] 1375 [649] 1560 [738] 1780 [840] 1125 [531] 1400 [661] 1575 [743] 1965 [927] 1150 [543] 1425 [672] 1645 [776] 2000 [944] 1250 [590] 1565 [738] 1820 [860] 2250 [1062] 730 [344] 860 [406] 1045 [493] 1270 [600] 720 [339] 835 [394] 1025 [484] 1250 [590] 1140 [538] 1350 [637] 1525 [720] 1730 [816] 1100 [519] 1380 [651] 1550 [732] 1930 [910] 1120 [528] 1390 [656] 1615 [762] 1940 [915] 1215 [573] 1540 [727] 1800 [850] 2185 [1031] 695 [328] 815 [384] 1005 [474] 1225 [578] 675 [318] 790 [373] 980 [462] 1200 [566] 1115 [626] 1310 [618] 1480 [698] 1675 [791] 1080 [510] 1365 [644] 1560 [736] 1890 [892] 1100 [519] 1375 [649] 1585 [748] 1880 [887] 1235 [582] 1505 [710] 1750 [826] 2110 [996] 660 [311] 770 [363] 965 [455] 1180 [557] 635 [300] 750 [354] 940 [443] 1150 [543] 1095 [517] 1270 [599] 1440 [679] 1625 [767] 1060 [500] 1350 [637] 1570 [740] 1850 [873] 1080 [510] 1360 [642] 1560 [736] 1820 [859] 1260 [595] 1475 [696] 1700 [802] 2040 [963] 615 [290] 725 [342] 920 [434] 1125 [531] 595 [281] 705 [332] 890 [420] 1090 [514] 1065 [503] 1235 [583] 1380 [651] 1555 [734] 1000 [472] 1260 [594] 1480 [698] 1765 [833] 1025 [484] 1280 [604] 1490 [703] 1745 [823] 1230 [580] 1425 [672] 1645 [776] 1965 [927] 570 [269] 680 [321] 875 [413] 1070 [505] 555 [262] 660 [311] 845 [399] 1025 [484] 1040 [491] 1195 [564] 1325 [625] 1480 [698] 940 [443] 1175 [554] 1390 [656] 1680 [793] 970 [458] 1200 [566] 1420 [670] 1675 [790] 1200 [566] 1375 [649] 1590 [750] 1890 [892] NOTE: Recommended blower speeds are in bold. NOTE: CFM values represent furnace only airflow ratings. [ ] Designates Metric Conversions 8

Accessories Vent Termination Kits Concentric: Horizontal/Vertical = RXGY-E03A (US & Canadian Installations) HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04 (US Installations) RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations) RXGY-G02 (US Only) CONDENSATE PUMP KIT: RXGY-B01 NEUTRALIZER KIT: RXGY-A01 FOSSIL FUEL KIT: RXPF-F01 RXPF-F02 (TVA) NON-COMBUSTIBLE FLOOR BASE: RXGC-B17 RXGC-B21 RXGC-B24 For High Altitudes ALTITUDE KIT*: INPUT BTU/HR [kw] ALTITUDE KIT NO. 60,000 [18] RXGY-F29 75,000 N [22] RXGY-F30 75,000 W [22] RXGY-F30 90,000 [26] RXGY-F31 105,000 [31] RXGY-F32 120,000 [35] RXGY-F33 LP CONVERSION KITS: U.S./Canadian: RXGJ-FP21 or RXGJ-FP19 EXTERNAL FILTER RACK: RXGF-CC MODEL RGTK- FILTER RACK FILTER SIZES* INCHES [mm] Plenum Data For Coils Refer to Coil Specification Sheets for Plenum Data. FOR LEFT SIDE (ALTERNATE) CONDENSATE DRAIN KIT: RXGY-H01 (All Models) [ ] Designates Metric Conversions RXGF-CC 06 (2) 12 x 20 [305 x 508] 07 (2) 12 x 20 [305 x 508] 09 (2) 12 x 20 [305 x 508] 10 (2) 12 x 20 [305 x 508] 12 (2) 14 x 20 [305 x 508] *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. *For installations over 5000 ft. CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting furnaces for high altitudes. For all installations above 2000 ft. the burner orifice size needs to be recalculated and verified. See Installation Instructions for more information. NOTE: For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. 9

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts* (Registration Required)...Ten (10) Years Heat Exchanger...Limited Lifetime 10

Notes 11

The new degree of comfort. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.rheem.com Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A 04/12 QG FORM NO. G11-531