LED IMPORTANT SAFETY INSTRUCTIONS

Similar documents
LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

CFP-LED Contractor Select Flat Panel. Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

General Installation Instructions LED

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

General Installation Instructions LED

Installation Instruction ALG Series LED Area Light Version: 3.1

Installation Instructions BLTR and 2BLTR Relight Assembly

Universal Retrofit System Installation Instructions Revised:

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:


ArenaVision LED BVP420/BVP978

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

TECTONIC LED CORP. ISO

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

LED IMPORTANT SAFETY INSTRUCTIONS

LED Recessed Troffer Retrofit Kit

Instruction/Installation Manual

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

Lumination TM LED Luminaire LUR Series

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Product Installation Instruction LED Tube Lamp Retrofit Kits

LED 2/3/4ft T8 Tube 120V

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

MaxLite LED Linear HighBay Fixtures

SAVE THESE INSTRUCTIONS

Solid State T8 tube is the smart alternative to a

SAVE THESE INSTRUCTIONS

Options AMF Antimicrobial Finish (All Exposed Surfaces) BLK Black Doorframe. Accessory

SAVE THESE INSTRUCTIONS

Optimax Pro Retrofit Instructions

INSTALLATION INSTRUCTIONS

MaxLite LED UTILITY WRAP FIXTURES

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

PDX and PX Retrofit Series

UV-AIRE AIR PURIFYING SYSTEM

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

LM79 LM80 L70:5+ YEARS

INSTALLATION INSTRUCTIONS

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

Square Solar Garden Light 95706

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

HPFB. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

SAFETY. Read and understand all safety precautions and instructions before installing this product.

CSA CERTIFIED Conforms to UL 507

INSTALLATION INSTRUCTIONS

MaxLite StaxMax LED Flood Lights

Predator Medium Floodlight Wet Location

Assembly Instructions Retrofitting

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

SAFETY. Injury hazard

MEDMASTER CLEANSCENE MRI/Imaging Suite Luminaires

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

INSTALLATION & OWNER S MANUAL

SAFETY. Read and understand all safety precautions and instructions before installing this product.

SAFETY. Injury hazard

SAFETY. Injury hazard

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS SEMI-HIDDEN WINCH MOUNT Part Number:70005 Application: Ford Super Duty

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

INSTALLATION INSTRUCTIONS

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

TECHNICAL SPECIFICATIONS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

SAFETY. Read and understand all safety precautions and instructions before installing this product.

UL AND CODE COMPLIANCE

Universal Splice Tray Installation Instructions

Shortening Disposal Unit

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

Prismpack V, Prismalume V, Large Prismpack, Large Prismalume

Installation Instructions: Eco-Fit T8 LED Tube Lamp

INSTALLATION INSTRUCTIONS

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Electric Vehicle Charging Station

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Transcription:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels. Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. Installation and service of luminaires should be performed by a qualified licensed electrician. Maintenance of the luminaires should be performed by person(s) familiar with the luminaires construction and operation and any hazards involved. Regular fixture maintenance programs are recommended. It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary. DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes, this matter should be referred to Acuity Brands Lighting, Inc. WARNING RISK OF ELECTRIC SHOCK Disconnect or turn off power before installation or servicing. Verify that supply voltage is correct by comparing it with the luminaire label information. Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. All wiring connections should be capped with UL certified wire connectors. WARNING RISK OF BURN Allow lamp/fixture to cool before handling. Do not touch enclosure or light source. Do not exceed maximum wattage marked on luminaire label. Follow all manufacturer s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling. CAUTION RISK OF INJURY Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. Avoid direct eye exposure to the light source while it is on. CAUTION RISK OF FIRE Keep combustible and other materials that can burn, away from lamp/lens. Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying. Page 1 of 7

CAUTION: RISK OF PRODUCT DAMAGE Never connect components under load. Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation. Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit. Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling. Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature. Only use fixture in its intended location. LED products are Polarity Sensitive. Ensure proper Polarity before installation. Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit. Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance. Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance. Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings. Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. Our Brands Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls Daylighting Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT SunOptics Carandini Mark Architectural Lighting Antique Street Lamps LC&D Holophane Peerless Hydrel ROAM RELOC Renaissance Lighting Tersen Sensor Switch Light Concepts Winona Lighting Synergy Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10 Page 2 of 7

WARNING Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retro fit kit. Check for enclosed wiring and components. WARNING Risk of fire of electric shock. LED Retrofit kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING Risk of fire of electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. WARNING To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. WARNING: Electrical shock can occur during retrofit component installation if power is not turned off. WARNING: Installation of this retrofit assembly requires a person familiar with the construction and operation of fluorescent luminaire electrical systems and the hazards involved. WARNING: Ensure that existing fixture is and remains properly connected to building ground. Use of any other than the Lithonia Lighting supplied screws to install assembly may result in ungrounded fixture components. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. For cul units, THE RETROFIT KIT IS ACCEPTABLE AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION NOT FOR USE WITH DIMMERS Page 3 of 7

LED IMPORTANT SAFETY INSTRUCTIONS Class R type ll retrofit Kit Installation Instructions for Fixture Conversion Retrofit Classified by Underwriters Laboratories, Inc Reflector Kit Type ll : Reflector installation or replacement Lamp holder relocation, removal, or replacement Ballast relocation, removal, replacement or addition This retrofit kit will consist of: (2) Lower end brackets (Note: Paint color depends on specific kit ordered. 2VT_R kits black; 2VT_RT kits white) (1) Prewired LED electrical assembly with LED boards, LED Driver, ballast disconnect. (1) Reflector (1) Doorframe / trim / refractor assembly (1) Hardware pack containing self-drilling tek screws, serrated washer head screws, and self-adhesive wire guides (Job packs will have bulk-packed hardware with each pallet) Note: 2VT_RT kits will also include (2) white molded trim strips shown below. Trim strips are not needed and are not included in 2VT_R kits. Upper End Brackets LED Light Engine Lower End Brackets Wire management clips (2) Tek Screws (8) Ballast Mount Enclosure Plate (2) Doorframe / Trim Trim Strips Included only with 2VTLRT Kits Serrated Washer Head Screws (4) This kit is approved for installation in luminaires with steel housing construction (not aluminum), having the dimensions shown, in dry or damp locations. This kit is approved for use in air handling luminaires when the intended air path is along the luminaire side(s) as shown. 13-1/2 MIN FLAT Air Path 3-5/8 MIN DEPTH Host fixture housing section Page 4 of 7

Step One: Locate the fluorescent lighting fixture that is to be retrofitted. Turn off power. Remove louver or doorframe from existing fixture. Remove lamps and set aside to be recycled. Remove existing ballast cover. Identify power supply wires and clip to prepare for use with ballast disconnect. Remove ballast, lamp holder brackets, and lamp leads as necessary to provide adequate clearance for kit installation. NOTE: Fasteners removed during component removal must be reinstalled to close open holes. If ballast is secured with a screwless mounting feature, use provided ballast mount enclosure plate to complete enclosure as shown. Recycle or properly dispose of all components removed from host fixture. Step Two: Lamps Assemble upper and lower end brackets. (See image) Install assembled end brackets by sliding lower end bracket flange between T-grid and lower frame of host fixture, sliding back until assembly seats firmly against host fixture end plate. Use provided tek screws to secure end bracket assembly into position. Position wire management clip at least 4-1/2 from center line of housing. Ballast Ballast Cover Lamp holders and bracket Doorframe / Louver BALLAST MOUNT ENCLOSURE PLATE INSTALLATION Slide and lock upper and lower end brackets together as shown. Provided tek screws Wire management clip Page 5 of 7

Step Three: Hang light engine from either side of upper end brackets on hooks provided. Light engine hangs freely during wiring. Connect ballast disconnect to incoming power supply. After wiring is completed, rotate light engine into final position and attach at each end with serrated hex washer head screw. Opposite side is supported by upper bracket only. Use wire management clip to position wires away from LED board mounting panel. Light engine securing detail. Light engine Serrated hex washer head screw Light engine support clip (Component of upper end bracket) Light engine securing detail. Step Four: Install Door / Trim / Enclosure The trim assembly hinges and latches from either side. Slide corner hinge into the slot in one if the end brackets and repeat on opposite end. Attach bond wire to host fixture housing. Close door and rotate cam latches into cam latch receiving slot. Check to make sure cam latches are properly engaged and door is secure. Page 6 of 7

Optional Step to Install Trim Kits (lensed troffer application): The 2VT8RT / 2VT5RT Relight Assembly is shipped with two flexible reveal cover trim pieces. Some installations in existing lensed troffers can leave unsightly gaps between the side rail of the Relight door frames and the existing housing, which can leave old hinge and latch points exposed. The trim kit is designed to cover these to insure an attractive installation. To install, slide the ends of the trim piece under the Relight end brackets as shown in in the photo. When they are fully in place, slide the notch of the trim piece towards the end bracket to fully seat the part. The part is flexible so this step can typically be completed either before or after full installation of the Relight assembly. WIRING DIAGRAM EXISTING FIXTURE GROUND WIRE COLOR INDICATORS TO LED LIGHT ENGINE INCOMING SUPPLY SUPPLIED BDP Help save our environment by recycling all remaining components. Save these instructions. Page 7 of 7