* With I-Option card only (C. T. connection) Basic connections with isolated contacts

Similar documents
2. SIKOSTART 3RW24 Principle of Operation 2.1 Starting & Stopping Continuous Operation Protection and Control... 2.

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3)

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

3RW Soft Starters. General data. 6/4 Siemens LV

An Engineering Guide to. Soft Starters

For Operation in the Control Cabinet 3RW Soft Starters

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Dimensions WxHxD [mm] Weight [kg]

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Price List July 2017

4491 en / c. D IGISTART et. Reference guide

Pocket Guide VLT Soft Starter the single speed drive

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

Low cost, internally bypassed non optimizing soft starter

Open Chassis Star-Delta Starter User Guide

FAN-STOP INSTRUCTION MANUAL

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Soft starters SIRIUS 3RW30 / 3RW40. Manual 01/2010. Industrial Controls. Answers for industry.

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

SDS Enclosed Star-Delta Starter User Guide

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

ABB s new control and protection devices

Fairford Electronics Product Selector

SOLSTART Instruction Manual

Programmable Logic Controller. Mat Nor Mohamad

CTi Automation - Phone: Fax: Web:

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

Pocket Guide VLT Soft Starter the single speed drive

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

RVS-DN Digital Reduced Voltage Motor Starter

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44

Technical specifications

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

For Operation in the Control Cabinet

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

DEVICE STATE/BYPASSED FAILURE OVERLOAD

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

Contactor Relays 3TH30

RVS-AX Instruction Manual

Fincor Series 2230 MKII/2240

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Guide to contents - applicable to

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to

Panorama. Softstarters The complete range

RVS-DN Digital Soft Starter A, V Instruction Manual


DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Benefits of using the Eaton S811+ soft starter to improve uptime and lower maintenance costs

Starting of Induction Motors

Product Brochure. The motor speed control experts. AC motor speed control products and peripherals for the motion and automation control industries

Motor Starters, Soft Starters and Load Feeders

Metering Products Protection Units Current Transformers. April 1, 2015

Electronic timers CT-S range Function diagrams

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Exercise 1-3. Manual Starters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Direct-on-line (DOL) starters. Reversing starters

RVS-DN Instruction Manual

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

Pressure Makeup Jockey Pump Controller

ICG Switchgear Price List 2009

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

RVS-DX Digital Reduced Voltage Motor Starter

Low-Voltage Controls and Distribution

HIB Enclosed Inverter User Guide

Operating Instructions VLT Soft Starter MCD 500

SCR POWER REGULATORS & HEATING CONTROL PANELS. 1/2/3-Phase 15 ~ 750+ Amps 220 ~ 480 V AC.

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Deepika Enterprises.

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

Section 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

For Operation in the Control Cabinet

MCD Pump Application Module

Leadership driven by innovation

Aldi V4 & V V1.1 5/23/2014

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

SIRIUS Soft Starters Introduction

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

J TS 7090 Thyristor power switch

Thyristor Power Regulators

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Motor Starters, Soft Starters and Load Feeders

Transcription:

Typical Circuit Diagrams. Typical Circuit Diagrams Basic connections with isolated contacts F2 - Overload relay Q1 - MPCB / ACB / MCCB /K2 - Main isolating contactors (AC-3 rated) F3 - Semiconductor Fuses (Optional) BH - Command "Ramp-up" BF - Command "Enable" ME - Monitoring signal "In operation" MH - Monitoring signal "End of ramp" Only with I-Option card MU - Monitoring signal "Overload". * With I-Option card only (C. T. connection) 230 V AC external power supply *** Thermistor or thermostat motor protection.1

Typical Circuit Diagrams Control through PLC Basic connections for PLC with 24 V = industry logic Q1- MPCB / ACB / MCCB - Main isolating contactor (AC-3 rated) F3 - Semiconductor Fuses (Optional) F2 - Overload relay L - is preferably to be earthed. Remove link 49-0 if there is a potential difference between L - and PE (max. permissible voltage 60 V) * With I-Option card only (C. T. connection) *** Thermistor or thermostat motor protection.2

Typical Circuit Diagrams Recommended connection : 3RW24 Line Connection for Soft Start (also with I-OPTION card) = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses (Optional) K3 = Bypass contactor (Optional) S1 = OFF push button (Momentary command) S2 = ON push button (Momentary command) * With I-Option only (C. T. connection).3

Typical Circuit Diagrams Recommended connection : 3RW24, Delta Connection for Soft Start (also with I-Option card) = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses (Optional) K3 = Bypass contactor (Optional) S1 = OFF push button S2 = ON push button *MU - only with I-Option card * With I-Option only (C. T. connection).4

Typical Circuit Diagrams Recommended connection : 3RW24, Line Connection Soft Start and Soft Stop (also with I-Option card) = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses (Optional) K3 = Bypass contactor (Optional) S1 = OFF push button S2 = ON push button K2 = Auxiliary contactor (4 NO) * With I-Option only (C. T. connection).

Typical Circuit Diagrams Recommended connection : 3RW24, Line connection as a Soft Start and Soft Stop for reversing application F3 = Semiconductor fuses (Optional) f = Main isolating contactor in forward direction R = Main isolating contactor in reverse direction ON1 = Forward direction ON2 = Reverse direction K3 = Bypass contactor (Optional) K2f = Auxiliary contactor (4NO + 4NC) K2R = Auxiliary contactor (4NO + 4NC) S1 = OFF push button (Momentary Contact) S2.0 = ON push button S2.1 (Momentary Contact) * With I-Option only (C. T. connection) 230 VAC, external power supply.6

Typical Circuit Diagrams Recommended connection : 3RW24, Line connection (also with I-Option) for soft start and speed change of motors in the pole-change Dahlander connection. This connection provides for zero-current contactor switching F3 = Semiconductor fuses (Optional) = Main isolating contactor (AC-3 rated) K3 = Bypass contactor (Optional) K4 = Auxiliary contactor (3NO + 1NC) K = Auxiliary contactor (4NO) K21 = Contactor - Slow speed 1 = Aux. Contactor (4NO) 2 = Aux. Contacor (4NO) K22-1= Star contactor (Dahlander wdg. only) S2 = ON slow speed S3 = ON high speed S1 = Off command F4 = Overload relay * With I-Option card only (C.T. Connection).7

Typical Circuit Diagrams Recommended connection : 3RW24, Line connection I-Option card combined with a star/delta starter for starting with low starting currents (e.g. screw compressors in bypass). PE L1 L2 L3 2 ~ 110...41 V F1 K6 21 22 MU * F2 S1 OFF F2 S2 ON K6 F3 ** G1 k4 41 1 42 PE L1 L2 L3 F k4 k4 K2 k3 k4 ME 2 3 4 MH BH 6 7 P10 3RW24 O PE 49 0 K2 k3 8BF 9 SW 10 K6 K3 K2 k4 T1 T2 * T3 H K2 K3 W1 V1 U1 M 3 ~ W2 V2 U2 F3 = Semiconductor fuses = Bypass contactor K2 = Delta contactor K3 = Star contactor K4 = ON -delay timers S1 = OFF Push button S2 = ON Push button K6 = Line contactor * With I-Option card only (C.T. Connection).8

Typical Circuit Diagrams Recommended connection : 3RW24, Delta connection combined with a star/ delta starter for emergency starting) F1 = Semiconductor fuses F3 = Motor feeder HRC fuses = Bypass contactor K2 = Delta contactor K3 = Star contactor K = Auxiliary contactor (3NO + 1NC) K4 = 7PU60 star-delta timer S1 = OFF push button S2 = ON push button S3 = Star-delta change over switch K6 = Line contactor * With I-Option card only (C. T. connection) Rapid push button start is not possible. Push button must be pressed for sufficient time..9

Typical Circuit Diagrams Recommended connection : 3RW24, Line connection as a voltage controller (e.g. for running the motor at lower speed, special motor, control of electric heating) F1 = Motor feeder fuses = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses US -11 = 10kΩ potentiometer * With I-Option card only *** Thermistor or thermostat motor protection.10