MWF+ Application. Types Available. Average temperature sensor. Datasheet

Similar documents
AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Differential Pressure Sensors

Differential Pressure Transmitter

Differential Pressure Sensors

EGQ 212: Duct transducer, CO 2 and temperature

Cable Temperature Sensor passive / active / LON TF25

Temperature Controller (Heat Pumps)

NEW PRODUCTS THE EFFECTIVE SENSOR MANUFACTURER FROM GERMANY

NEW PRODUCTS WORLD EDITION 2018 THE EFFECTIVE SENSOR MANUFACTURER FROM GERMANY

Differential pressure sensor

NEW PRODUCTS WORLD EDITION 2018 THE EFFECTIVE SENSOR MANUFACTURER FROM GERMANY

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Immersion temperature sensor QAE26.9.

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Intelligent Positioner

NEW PRODUCTS WORLD EDITION 2018 THE EFFECTIVE SENSOR MANUFACTURER FROM GERMANY

THERMASGARD FSTF. Room temperature sensors in-wall, panel switch programme, general TECHNICAL DATA

INSTRUCTION MANUAL Oil level with pointer indicator

JUMO MIDAS S05 Pressure transmitter Type

Pressure & Velocity. Sample applications 223. Gases. Flow Meter / Air Velocity. Manometer. Fluids. Pressure & Velocity

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Direct Coupled Damper Actuator Model MY6050A1001

Direct Coupled Damper Actuator Model MY9050A1001

See «Overview of types»

Pressure Transmitter

Operation Manual for. CU2 Helmholtz Coil System Closed-Loop Module

HD UNIT INSTALLATION & SERVICE BOOKLET 3-7

Compact Pressure Transmitter DAN-HH

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

Accessories STRA Room Controller

Operating Instructions Pedestrian Turnstile Type MPT 33

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

EDI K_Instructions.qxd 28/07/ :34 Page 1 ORDER CODE: EDI K MODEL IRT537. Infrared Thermometer OPERATING MANUAL CLASS 2 LASER

VE-S_15-32 Pressure Independent Balancing & Control Valves

TEMPERATURE - HUMIDITY VAISALA HMP155

Beck. The differential pressure transmitter for air with IP65

THERMASGARD TF 43 THERMASGARD TF 65

Temperature Sensor without thread

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electro-hydraulic actuators for valves

BigPoints Information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

Figure 1: WPR2 Dimensions and Hardware

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

2-Color Display High-Precision Digital Pressure Switch

More Precision. mainsensor Magneto-inductive displacement sensor

Digital ph transmitter

Cable Temperature QAP... Sensor. Use

Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting. Features

SPT- I / U PRESSURE TRANSMITTER for general applications

Series ISA. Air Catch Sensor. For Detection of Work Presence

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Emergency lighting units EM powerled

ProMinent. Operating Instructions Turbine Meter turbodos

Low Pressure Sensor. Overview. Specifications. Installation and Operation

362 Clamp Meter. Users Manual

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Differential Pressure Sensors

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

GE Measurement & Control

Differential Pressure Sensors

Series 7000 Torque Sensor for PTO-shafts

EMO TM. Actuators High performance proportional actuator For modulating control

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

BAPI-Stat 3 Room Sensor

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Screw-in resistance thermometers with plug connector

Inductive conductivity meter

Digital ph transmitter

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Switching DC Power Supply

Series 7000 Torque Sensor for PTO-shafts

HUMIDITY / TEMPERATURE TRANSMITTER

better measurement Simply a question of

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

Series 10-ZSE40A(F)/10-ISE40A

INTERNATIONAL METAL ENGINEERING

Type SAM-01 to Type SAM-52 Electric Actuators. Type SAM-20, 30 mm rated travel, 6 kn thrust. Mounting and Operating Instructions EB 8330 EN

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Servo solenoid valves with on-board electronics (OBE)

EPS/ELA-Series User Manual EPS/ELA 250W

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

Electrical linear actuator with safety function MC100FSR/24

UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

Installation and Operating Instructions. Solar System Controller ISC3020

ULTRASONIC FLOW SENSOR IFX-M4-01

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Time Electronics DC Multifunction Voltage/Current/Resistance Calibrator. Technical Manual

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

Transcription:

MWF+ Average temperature sensor Datasheet Subject to technical alteration Issue date: 28.03.2018 A002 Application Duct averaging temperature sensor in enclosure USE-S for measuring the average temperature in air ducts. The sensor detects the applied temperature value throughout the entire length. Mounting angles for uncomplicated duct mounting are included in delivery. A spring at the connection head reduces vibrations. Types Available Duct averaging sensor temperature MWF+ <Sensor> L<x> incl. installation kit Duct averaging sensor temperature active 0..10 V 4..20 ma MWF+ MultiRange L<x> incl. Installation kit MWF+ MultiRange L<x> incl. Installation kit <x>: sensor rod length 3000/6000 mm <sensor>: Pt1000/Ni1000/Ni891/Ni1000TK5000 MultiRange: Measuring ranges adjustable at the transducer

Page 2 / 5 Issue date: 28.03.2018 Security Advice Caution The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorised modifications are prohibited! The product must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual Notes on Disposal As a component of a large-scale fixed installation, Thermokon products are intended to be used permanently as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act (WEEE) is not applicable. However, most of the products may contain valuable materials that should be recycled and not disposed of as domestic waste. Please note the relevant regulations for local disposal. General remarks concerning to sensors Especially with regard to sensors in 2-wire conductor versions, the wire resistance of the supply wire has to be considered. If necessary the wire resistance has to be compensated by the follow-up electronics. Due to self-heating, the wire current affects the measurement accuracy. So it should not exceed 1 ma. When using lengthy connection wires (depending on the cross section used) the measuring result might be falsified due to a voltage drop at the common GND-wire (caused by the voltage current and the line resistance). In this case, 2 GND-wires must be wired to the sensor - one for supply voltage and one for the measuring current. Sensing devices with transducer should always be operated in the middle of the measuring range to avoid deviations at the measuring end points. The ambient temperature of the transducer electronics should be kept constant. The transducers must be operated at a constant supply voltage (±0,2 V).When switching the supply voltage on/off, onsite power surges must be avoided. Build-up of Self-Heating by Electrical Dissipative Power Temperature sensors with electronic components always have a dissipative power, which affects the temperature measurement of the ambient air. The dissipation in active temperature sensors shows a linear increase with rising operating voltage. This dissipative power has to be considered when measuring temperature. In case of a fixed operating voltage (±0,2 V) this is normally done by adding or reducing a constant offset value. As Thermokon transducers work with a variable operating voltage, only one operating voltage can be taken into consideration, for reasons of production engineering. Transducers 0..10 V / 4..20 ma have a standard setting at an operating voltage of 24 V =. That means, that at this voltage, the expected measuring error of the output signal will be the least. For other operating voltages, the offset error will be increased by a changing power loss of the sensor electronics. If a re-calibration should become necessary later directly on the sensor, this can be done by means of a trimming potentiometer on the sensor board. Remark: Occurring draft leads to a better carrying-off of dissipative power at the sensor. Thus temporally limited fluctuations might occur upon temperature measurement.

Issue date: 28.03.2018 Page 3 / 5 Technical Data Measuring values Output voltage Output ampere Output e Power supply Power consumption Measuring range temp. Accuracy temperature temperature 1x 0..10 V or 0..5 V, min. load 5 kω 1x 4..20 ma, max. load 500 Ω optional, PT1000/Ni1000/Ni891/Ni1000TK5000 15..24 V = (±10%) or 24 V ~ (±10%) SELV typ. 0,4 W (24 V =) 0,8 VA (24 V ~) adjustable at the transducer: -50..+50-20..+80-15..+35-10..+120 0..+50 0..+100 0..+160 0..+250 C, default setting: -20..+80 C ±0,5 K (typ. at 21 C within default measuring range) 15..24 V = (±10%) SELV typ. 0,5 W (24 V =) -50..+80 C, depending on used sensor Pt1000: DIN class B Ni1000/Ni891/Ni1000TK5000: ±0,4 K (typ. at 32 F) Enclosure enclosure USE-S, PC, pure white, with removable cable entry Protection IP65 according to EN 60529 Cable entry Connection electrical Sensor rod (optional) Ambient condition Flextherm M16, for wire Ø=3..7 mm, removable removeable plug-in terminal, max. 2,5 mm² 3000 mm, 6000 mm (optional) -35..+70 C, max. 85% rh short term condensation Mounting Advices Model MWF can either be mounted directly on the ventilation duct by means of a mounting flange or by screws. By means of the mounting brackets included the sensor rod is braced to the ventilation duct. Note: Please pay attention to the sensor rod while mounting and protect it from mechanical damage! Mounting angle: Vertical mounting Horizontal mounting

Page 4 / 5 Issue date: 28.03.2018 Connection Plan and Configuration The adjustment of the measuring ranges is made by changing the jumpers in a de-energized state. The output value of the new measuring range is available after 2 seconds. fig. (Measuring range and offset adjustment, default settings: -20 C..+80 C 0 K) Passiv (Pt1000 Ni1000 Ni891 Ni1000TK5000) fig. (terminal assignment sensor)

Issue date: 28.03.2018 Page 5 / 5 Dimensions (mm) Accessories (included in delivery) Mounting flange MF6 flexible (incl. inserts for Ø=4 6 7 mm) Item No. 399098 Mounting angle set Item No. 458399 Mounting kit universal Item No. 698511 Cover screw + screw cover 2 Rawlplugs 2 Screws (countersunk head) 2 Screws (rounded head) Accessories (optional) Mounting base enclosure USE pure white Item No. 667722 Mounting flange MF7 (brass) Item No. 102360 M16 Sealing inserts cable entry (packaging unit 10 pcs.) for wire with Ø 8 mm Item No. 641340