Commercial Garage Door & Gate Operators

Similar documents
MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318

EXTREME R MOTOR OWNER'S MANUAL

Selection Guide. Commercial & Industrial. Door Operators

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

COOKSON OWNER'S MANUAL

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

SAFE AND SECURE EXTREME R MOTOR OWNER'S MANUAL MODEL PRO-FDG FOR TECHNICAL SUPPORT PLEASE CALL 1-(855) OPERATOR SERIAL#

REVISIONS. App Thom. App Sud. App PC T.C. 2013/10/01

Model H/HB Heavy-Duty Industrial Drawbar Door Operator Safety, Installation and Service Manual

INSTALLATION AND INSTRUCTION MANUAL MODELS: PRO-T, PRO-TB

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

FUNCTION: Allows existing Logic Control Version 2.0 or 2.0 Rev. B board in field to be replaced with new Logic Control Version 2.0 Rev. B.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

ZAP Controls. ZAP Controls. Series 3 Commercial Operator Catalog. Series 3 Commercial Operator Catalog. ZAP Series 3 Simply Logical.

ELSEMA 240VAC Slider Control Board, SLD

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

PATTERSON PUMP COMPANY

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

SECTION MOTOR CONTROL

Model JG Industrial Gearhead Jackshaft Door Operator Safety, Installation, and Service Manual

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

RHX Commercial Operator. New state-of-the-art features and technology for easy and reliable operation.

VEHICULAR AC & DC. Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage

ZAP Controls. Series 3 DC Commercial Door Operator Catalog. Commercial Operators that use SafetySense

Application Engineering

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Application Engineering

CWM_N NEMA Rated Contactors

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

SKC400U SLIDING GATE OPENER OWNER S MANUAL

APOLLO Gate Operators, Inc.

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

ELEKTROMATEN ST Sliding-door-drive

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Single or Double 240VAC motor control for domestic and industrial gates and doors.

RSX Commercial Operator. An innovative line of Standard Duty Commercial Operators that improve the productivity of any facility.

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Electric Motor Controls BOMA Pre-Quiz

HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY. Serial # Box. Installation Date. Wiring Type

OWNER S MANUAL MODEL NO. MEDIUM DUTY JACK SHAFT OPERATOR MDJ, MDJH, MDJB, MDJBH READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS

Hydropak Booster Systems. Series motralec

4" Motors and Controls

Design Standard. Purpose: Design Standard:

Swing Gate Kits AUTOMATIC GATE KITS & ACCESSORIES SECURING GATES SINCE Control Cards. Accessories 2017 / Gate & Door Controls Catalogue

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Operator

Power System Solutions (PSS)

REEVES MOTO DRIVE BASIC PRICING

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

MODEL JH-D DC BATTERY BACK-UP JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL

Electrical Control System Components Basics of Magnetic Control :

RAPIDMIX 400CW. Length of Machine (19.5m) Length when erected Width of Machine 9-10 (3.00 m) Width Same

TDX - Taco Duplex Starter with

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Critical Power Switchboards. Selection and Application Guide

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

ELSEMA Single / Double Gate Controller, for 12V / 24V Motor, GATCO12S, GATCO24S, GATCO12D, GATCO24D

HORIZONTAL SLIDING DOORS

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

COVER PLATES & ROLLERS

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

Electromotive Systems IMPULSE G+ Mini Adjustable Frequency Crane Controls

WARREN COUNTY, N.Y. M/E REFERENCE

Rolling Door Operator User s Manual

BI-PART SLIDING DOORS

GLM SERIES CONTROL Users Manual Rev:

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

2006 Series Geared Rotary Limit Switches

SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL

SPACEMASTER WIRE ROPE HOISTS

ADJUSTABLE FREQUENCY CRANE CONTROLS

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

E Series Electric Actuators

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

FireCoil. Commercial Fire Doors FireCoil

APOLLO Gate Operators, Inc.

Horizontal Circuit Switchers

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Door Operator

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

Horizontal Circuit Switchers

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Basics of Control Components

NON-SIZED SIZED HANDED

Application Description

Comfort. Description. Applications

XENON POWER SUPPLY 2000 Watt

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

NEW! Complete IMPULSE Control Panels Available

Technical Data Book. Door Operators. Commercial & Industrial. Edition V0

T57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS

100E. hubbell industrial controls, inc. EUCLIDTM

Transcription:

Commercial Garage Door & Gate Operators Approved to UL Standard 325

Industrial Electronic Door Control LYNX 6000 2 1. Electronic Control Provides unmatched ruggedness that incorporates the newest features never before in a door operator. Static protection; automatic snow limit setting; data buss; diagnostic lights; rotation switch; auto reset 24V fuse; brown out protection; never loses memory; three-button station; to remote monitoring/ operation. One control board for 1 or 3 phase and 115, 230, 460, or 575 voltages. 2. Metal Stamped Levers Stops the inaccuracy, labor cost and damage due to hand bent switch levers. 3. Long Life Limit Switches Carries only signal currents, no arcing, no electrical wear and no mechanical drift caused by pitted contacts. 4. Built-In Contactor State of the art circuit board mounted, nema1, rated for 200,000 operations at full load. Reduces wiring. 5. Printed Circuit Board Thick, wide, double sided and redundant copper traces, handle locked rotor current. 6. Motor Connections Three 1/4 fast-ons. Size prevents wiring errors. 7. Terminal Block Quick connection of board to all low voltage external wiring. 8. Diagnostic Lights Save time troubleshooting with seven easy to identify indicator lights; Power Indicator, Direction Indicator for Close and Open, Safety Edge Indicator, External Push Buttons Indicators for Open, Close, and Radio Control. 9. Automatic Snow Limit Electronically set by circuit board eliminates field adjustments and call backs saving installers time. 10. On-Board Three-Button Station Large, color-coded, clearly marked, positive feed back push buttons. Saves time at installation and troubleshooting reducing the climbing up and down ladders. Quickly narrows down problems by removing external connections and checking door operation at the circuit board. 11. Programming Switches Change from momentary to constant pressure easily adding safety to the operation of the door. 12. Data Buss Provides input/output connection for building automation for monitoring and/or operating the door remotely. Auxiliary circuits are easily added by plugging into the data buss. Future regulations can be added through the data buss without changing circuit board or operator. 13. Limit cams Adjustable nut cams to control door traveling. 14. Transformer 24 volt, 40va transformer. 6va operator and 34va for accessories. 15. Circuit breaker Built in on all single phase operators. 16. Plug-in Auxiliary Circuits Single timer, Dual timer, Photo Cell Interface, Fail Safe Edge, and Jam Detection. 17. Auto Reset 24 Volt Fuse Protects door operator. External load short circuits no longer damage motor controller or transformer. 18. Rotation Switch Eliminate mounting orientation problems. Becomes a left or right mounted operator with the flip of a switch.

LDT 1/2HP, 115V single phase motor, capacitor start, built in overload protection. Solid state circuit board Lynx-22. Built in 1.5 second delay. Adjustable mechanical safety reverse. 4L V-belt primary reduction. #65 roller chain and sprockets. Lynx photocell included. TC3 1/2, 3/4HP, 115-230-460 or 575V, single or three phase motor, Adjustable mechanical safety reverse. 4L V-belt primary reduction. #65 roller chain and sprockets. MC3 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase Adjustable friction clutch. 4L V-belt primary reduction. #65 roller chain and sprockets. MC3H 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase Adjustable friction clutch. 5L V-belt primary reduction. #41 roller chain and sprockets. 3

MCB 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase 4L V-belt primary reduction, spur gears on secondary reduction. #65 roller chain and sprockets. MCBH 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase 5L V-belt primary reduction, spur gears on secondary reduction. #41 roller chain and sprockets. MRAT 1/2, 3/4HP, 115-230-460 or 575V, single (instant-reverse) or three phase Timer to close (0-4 min) with red and green traffic lights. Adjustable mechanical safety reverse. 4L V-belt primary reduction, #65 roller chain and sprockets. Heavy duty single button wall station. 4 LDJB 1/2HP, 115V single phase motor, capacitor start, built in overload protection. Solid state circuit board Lynx-22. Built in 1.5 second delay. 4L V-belt primary reduction, #65 drive chain and sprockets. Adjustable friction clutch. Quick release, wall disconnect device for emergency manual operation. Magnetic solenoid brake. Lynx photocell included.

MCJ 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase motor, 4L V-belt primary reduction, #41 drive chain and sprockets. Quick release, wall disconnect device for emergency manual operation. MCJH 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase motor, 4L V-belt primary reduction, #41 drive chain and sprockets. HDC 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase motor, 5L V-belt primary reduction, #50 drive chain and sprockets. MCJH-EX 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase NEMA 7 & 9 NEMA 7 & 9 explosion proof enclosure and conduits. 4L V-belt primary reduction, #41 drive chain and sprockets. Heavy duty NEMA 7 & 9 3 button wall station (Open, Close, Stop). Internal 3 pole terminal strip for radio control. 5

GHO 1/2, 3/4, 1, 1-1/2HP, 115-230-460 or 575V, single or three phase 40:1 ratio, heavy duty gear reducer in oil bath with cast iron housing. #50 drive chain and sprockets. Magnetic solenoid brake. GHO-EX 1/2, 3/4, 1, 1-1/2HP, 115-230-460 or 575V, single or three phase NEMA 7 & 9 NEMA 7 & 9 explosion proof enclosure and conduits. 40:1 ratio, heavy duty gear reducer in oil bath with cast iron housing. #50 drive chain and sprockets. Magnetic solenoid brake. Heavy duty NEMA 7 & 9 3 button wall station (Open, Close, Stop). Water Proof Enclosure NEMA 4 modification includes: Water proof electrical box. Water proof motor. Water proof 3 button wall station. 6 HGO 1/2, 3/4, 1HP, 115-230-460 or 575V, single or three phase motor, Splash proof cover with key lock. 5L V-belt primary reduction, #41 drive chain and sprockets. Internal 3 pole terminal strip for radio control. Quick release, disconnect device for emergency manual operation.

1 4 3 2 LYNX Circuit Board Accessories 1. Lynx board-6000 2. Lynx board-22 3. Volt surge suppressor 5 6 4. Light box 5. Single timer 6. Dual timer 3 1 2 Switches and Wall Stations 1. 3 Button station Waterproof 2. 1 Button station 3. Key switch 4. 3 Button station 5. Interlock 5 4 6 8 6. 3 Button station Waterproof-light 7. 3 Button station Waterproof-keyed 8. Ceiling pull switch 7 5 2 3 4 1 Lynx Radio Controls 1. Lynx key pad 2. Lynx 1 button transmitter 3. Lynx 2 button transmitter 6 4. Lynx (Open/Close/Stop) transmitter 5. Lynx receiver 6. Lynx (Open/Close/Stop) receiver 7

2 1 3 4 CANADA MONTREAL 175 Upper Edison, St-Lambert, Quebec, Canada J4R 2R3 1-888-589-5969 Tel.: (514) 866-1068 Fax: (450) 466-8852 Safety 1. Air kit 2. Omron photocell 3. Loop detector 4. Lynx photocell ONTARIO 1040 Meyerside Drive, Mississauga, Ontario, Canada L5T 1J4 1-888-839-5969 Tel.: (416) 674-4606 Fax: (905) 670-0806 U.S.A. OHIO 111 Weires Drive Archbold, Ohio, U.S.A. 43502 1-800-338-5399 Tel.: (419) 445-1010 Fax: (419) 446-2616 NEW JERSEY 166 Gould Avenue Patterson, New Jersey, U.S.A. 07533 1-800-234-5969 Tel.: (973) 278-5588 Fax: (973) 742-9832 Separate control panel ARIZONA 101 North 57th Avenue Phoenix, Arizona, U.S.A. 85043 1-800-233-3599 Tel.: (602) 352-1010 Fax: (602) 352-1341 Splash-proof cover www.lynx-nsw.com