DIGITAL CRANE SCALE MODEL: OCS-SP USER MANUAL

Similar documents
DIGITAL CRANE SCALE MODEL: OCS-S9 USER MANUAL

SAFETY GUIDE...4 PRECAUTION...4 PRODUCT CHARACTERISTICS...5 SPECIFICATION...5 MODEL...6 SIZE AND NET WEIGHT...7 OPERATION...8

OCS-T High Resolution Digital Crane Scale

OCS Series. High Resolution Digital Crane Scale. User Guide

Electronic Crane Scale

1. Introduction Specifications Operation Guide Trouble shooting Note... 13

BCS-OCS-Z Max capacity. (kg/lb) BCS-OCS-M/LED DISPLAY BCS-OCS-L /LCD DISPLAY. Max capacity. (kg/lb) 50000kg/100000lb BCS-OCS-A/LED BCS-OCS-B/LCD

Table of contents. 1. Overview Features & Specifications Keypad Operation General Scale Operations Battery Charging.

MODEL T Kg DIGITAL CRANE SCALE

Weighing Scale IDS-802. User Manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

CÔNG TY CÂN ĐIỆN TỬ THỊNH PHÁT TEL (08) FAX

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Crane Scale. NC Series OWNER S MANUAL

XK3190- A7. Weighing indicator USER MANUAL

PRECAUTIONS... 4 OVERALL VIEW(CASTON-III)... 7 OVERALL VIEW(CASTON-II)...

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

PORT-A-WEIGH CRANE SCALES

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

Model 8000XL OPERATOR MANUAL

CASTON OWNER S MANUAL

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

ECONOMY CRANE SCALE OPERATION & SERVICE MANUAL

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

DC 5000 Series Crane Scale Instruction Manual

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

Model 7400 OPERATOR MANUAL

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

CITIZEN. series. Precision Balances

OWNERS MANUAL iforks. Rev OWNERS MANUAL iforks 1

User s Manual. quattro. Version 1.0

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

Weighing Indicator TM701 Handrail scales

uline.com

GRAVITY MEASUREMENT, INC.

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

LHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1

GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY:

User Manual. Rev USER MANUAL MForks 1

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

USER MANUAL iforks. Rev USER MANUAL iforks 1

KERN HFM Version /2010 GB

Smart Load Cell TRQ1/TPL torque / top load tester family

KERN HFO Version /2015 GB

American Weigh Scales, Inc. DigiPEN-500 D i g i t a l H a n g i n g S c a l e. User Manual

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

HP Series Smart Solar Charge Controller HP2430/2440/2450/2460 HP4830/4840 UserManual

MODEL T Kg DIGITAL CRANE SCALE

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

Service Manual Electronic Precision Balances Page 2. KERN CH version 1.0. CH-SH-e-0110

WARNING! DO NOT WELD TO THE WEIGH BARS OR ANY STRUCTURE THAT THEY ARE ATTACHED TO

TP Series OWNER S MANUAL. Price Computing Scale (VER.2)

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

Weighing Indicator. M503 Chair scales

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety

Operating instructions Platform/floor scales

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

TS-PFS. User s Guide. Portable Feeder Scale For Weigh Session Totals. Totalized Weight Item Weight Item Count Nonvolatile Memory. Guide version 1.

CASTON OWNER S MANUAL

Virtual Measurements & Control. VC210 Operators Manual

Models XMC/XWS/XWT (-S) -XIS

EC1 Pocket Conductivity Tester Instruction Manual

Where There is Miboxer There is Power. User Manual. Model No.: C2-6000

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

Intelligent Solar Charge Controller. User's Manual. Please read this manual carefully before you use this product

Rally computer 3 Rally computer 3.GPS *

User Manual Solar Charge Controller 3KW

10 CRANE SCALES Price List May 2018

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Compact Scales. Software Revision V1.25 & above

T P M S. Multi Wheel Bluetooth. Tire Pressure Monitoring System. User Manual. Model: External

Wheel Load Scale WL 103. Operating Instruction. Contents. Page. 1. Technical details Construction and function Operating instructions 3

OVERVIEW OF CONTROLS

CM50 Solar Charge Controller

Owner s Manual. Advanced Wind/Solar Hybrid (Street Light) Controller

KERN HFA Version /2015 GB

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

I t n e t l e l l i l g i e g n e t n So S l o a l r a Ch C a h r a g r e g Co C n o t n r t o r l o l l e l r U e s r e s Man an al

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

BRAKE TESTER DECELEROMETER

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Intercomp. PT300 Users Manual. Manual #: E

ECscan20 Pocket Conductivity Tester Instruction Manual

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Where There is Miboxer There is Power. User Manual. Model No.: C4-12

SERVICE MANUAL Valor 1000 Scales

TYPE 5867 PORTABLE Q METER

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Transcription:

DIGITAL CRANE SCALE USER MANUAL MODEL: OCS-SP USER MANUAL

TABLE OF CONTENTS SAFE OPERATION GUIDE......... 2 CHAPTER 1 FEATURES AND SPECIFICATION... 3 1. Features...3 2. Main technical data...3 3. Specification......4 4. Appearance illustration...4 5. Power supply......5 CHAPTER 2 DISPLAY AND KEYS... 5 1. Scale display...5 2. Remote controller...6 CHAPTER 3 OPERATION GUIDE...7 1. On/off......7 2. Zero...7 3. Tare...7 4. Hold...7 5. Accumulation...8 6. Accumulation Search...8 7. Accumulation Clear...8 8. Battery Vlotage...8 9. Brightness......8 10. Zero Point....8 CHAPTER 4 PARAMETER SETTING & CALIBRATION...9 1. Parameter setting....9 2. Calibration....11 CHAPTER 5 COMMUNICATION WITH handphone...12 1. Install drive software.....12 2. Run weighing software..12 CHAPTER 6 DISPLAY ILLUSTRATION....14 CHAPTER 7 TROUBLESHOOTING GUIDE...15. USER MANUAL 1

SAFE OPERATION GUIDE: 1.Do not make lifts beyond rated load capacity of the crane scale, shackle. 2.Do not perform overhead weighing. Stay clear when crane scale is in operation. 3. Do not perform weighing under strong wind condition which may cause incorrect reading. 4. Do not perform weighing under environment of temperature rapid changes in which may cause incorrect reading. 5. Do not attempt to open this Crane scale, no user serviceable parts inside. 6. Do not remove wire rope stopper from hook. For safety reasons, always apply it. 7. Remove all loads from shackle or hook when not in used. 8. Before weighing, check and make sure that all hanging /load- receiving elements / devices are in good condition. 9. Check hook, shackle, safety pins, and latches periodically. Contact your dealer for parts replacement in case defect, deform or wearing is found. 10. Always lift loads vertically. USER MANUAL 2

1. Features CHAPTER 1 FEATURES AND SPECIFICATION Multi-weighing units: Kg, lb, N are selectable, generally kg are default unit. Multi-function operation: Tare;Zero;Auto zero tracking;total;hold; Overload warning and record, Calibration through remote controller,etc functions. User-friendly design: Cast aluminium housing for maximum protection; Large red 5 digit LED display (digit height 30mm); Gravity compensation; Safety factor up to 4 times capacity; Battery Operated with low battery indication; Automatic turn off, power-saving function. 2. Main technical data Standard Display Zero Range Tare Range Stable Time Overload Indication Max. Safety Load Ultimate Load Battery Life Battery Type Adapter According to OIML class III 30mm (1.2 ) 5digits LCD/LED 4% F.S. 20% F.S. 10 seconds 100% F.S. + 9e 125% F.S. 400% F.S. 50 hours Fully sealed Lead-Acid battery, 6V/5Ah DC9V/1000mA Operating Temp. - 10 ~ + 40 Operating Humidity 85% RH under 20 Remote Controller Distance Min. 15m Battery of Remote Controller 7# battery, 1.5Vⅹ2 USER MANUAL 3

3.Specification MODEL Max. capacity Min. weigh Division Total display (kg/lb) (kg/lb) (kg/lb) counts (n) OCS-SP-005 50 /110 0.4/1 0.02 /0.05 n=2500 OCS-SP -01 100 /220 1 /2 0.05 /0.1 n=2000 OCS-SP -02 200 /500 2/4 0.1 /0.2 n=2000 OCS-SP -03 300 /700 2 /4 0.1 /0.2 n=3000 OCS-SP -05 500 /1100 4 /10 0.2 /0.5 n=2500 OCS-SP-1 1000 /2200 10 /20 0.5 /1 n=2000 4. Appearance illustration MODEL A(mm) B(mm) C(mm) H(mm) N.W OCS-SP-005 75 20 25 370 4kg OCS-SP -01 75 20 25 370 4kg OCS-SP -02 75 20 25 370 4kg OCS-SP -03 75 20 25 370 4kg OCS-SP -05 90 25 27 390 4.5kg OCS-SP -1 90 25 27 390 4.5kg USER MANUAL 4

\ 5. Power supply Battery: 6V/5Ah fully sealed Lead-Acid battery Adapter: 9VDC/1000mA adapter Current: the crane scale average current is about DC 100mA±10%, if battery charged, it can be used for about 50hours. Low battery warning: When the digits flash, it means the battery needs to be recharged. The scale will power off automatically after 1 to 2 hours operation if the battery is not charged. Please recharge ] the battery before operating the scale again. Charging method: Turn off the crane scale, use adapter in the carton, the lamp on the back cover will become orange when charging, and it will become red when the charging finish. Generally, charging time should not less than 8hours, the crane scale have charging protection, long time charging can t damage the battery. CHAPTER 2 DISPLAY AND KEYS CAPACITY LOGO. LED DISPLAY AREA INDIC ATOR AREA KEY AREA INF RA-RED RECE IV E WINDOW 1. LED DISPLAY 30mm (1.2 ) 5digits LED/LCD 2. INDICATOR LAMP a. ZERO: ZERO indicator b. TARE: TARE indicator c. HOLD: HOLD indicator d. STB: STABLE indicator e. lb : lb unit indicator f. kg : kg unit indicator 3. KEY a. ON/OFF 1.Press ON/OFF three seconds,the crane scale turn on. 2.When turn on,press ON/OFF three seconds,the crane scale turn off. USER MANUAL 5

b. ZERO When crane scale switch on with no load on the hook, but there are small digits on screen, press this key to obtain zero reading. The ZERO indicator switches on. c. TARE 1 Hang sling or container on the hook, when the weight reading stable, press this key, the digits display 0, and TARE indicator switch on. 2.Put the goods into container, the scale will display goods net weight. 3.If move goods and container, the scale will display minus value of tare weight d. HOLD 1.When weight is changing,press this key will hold the reading,and HOLD indicator switch on. 2. Press this key again,reading will resume changing, and HOLD indicator switch off. 4. REMOTE CONTROLLER Press any key on the remote controller, the indicator on the controller will flash. Key function: 1. ZERO : a. In weighing status, the function is equal to ZERO on overlay(when crane scale switch on with no load on the hook, but there are small digits on screen, press this key to obtain zero reading. The ZERO indicator switches on). b. In parameter setting and calibration process, it used for set value up 2. TARE : a. In weighing status, the function is equal to TARE on overlay b. In parameter setting and calibration process, it used for move digit(the digit choosed flash) 3. SHIFT : a. In weighing situation, used for function shift, or used with other key to more function. b. In parameter setting and calibration process, it used for confirm setting. 4. CLEAR : a. In weighing status, it used to clear accumulation. b. In parameter setting and calibration process, it used for set value down. 5. ACCU : It used for accumulation function, details see Chapter3-5. 6. F1 : Function Key,used with F2 together, Press F1 solely, it will regulate brightness of LED. 7. F2 : Function Key,used with F1 together. 8. HOLD : It used for hold function, details see Chapter3-4. 9. OFF : Turn off the crane scale. USER MANUAL 6

CHAPTER 3 OPERATION GUIDE express key on remote controller. 1 TURN ON/OFF TURN ON Press ON/OFF three seconds, the screen display as follows: OPERATION DISPLAY ILLUSTRATION ON/OFF 88888 Display two times Ert Display two times XXXXX Display capacity U 6.XX Display current battery voltage ----- Waiting stable 0 STB light on, you can operate now TURN OFF 1 Press ON/OFF three seconds. 2 Press OFF three seconds. 3 Choose turn off method when parameter setting, the scale will display - after no operation at 15minutes to save power, and it will turn off automatically after 60minutes. 2 ZERO OPERATION DISPLAY When scale turn on, generally scale displays 0 Press ZERO 0 if display small digits when no load, press this key. 3 TARE TARE DIRECTLY OPERATION DISPLAY After turn on, hanging tare weight such as sling, 1 Press TARE 0 cable at first, press this key, TARE light on, then 2 Press TARE 0 the scale will display net weight of the goods. SET TARE WEIGHT IN ADVANCE OPERATION DISPLAY ILLUSTRATION SHIFT TARE 0000.0 Current tare weight TARE ZERO CLEAR xxx Set known tare weight, TARE used to move digit, ZERO CLEAR used to set value. SHIFT - xxx exit, TARE light on, it displays minus tare weight, after hanging on goods, it will display net weight of goods. 4 HOLD OPERATION Press HOLD Press HOLD again ILLUSTRATION Hold the weight reading no matter load change Return to normal weighing status USER MANUAL 7

5 ACCUMULATION OPERATION DISPLAY ILLUSTRATION Press ACCU No*** Current accumulation time H**** Front four digits of total value L**** Rear four digits of total value After display above contents two times, the scale will return automatically, you also can press SHIFT to return. 6 ACCUMULATION SEARCH OPERATION DISPLAY ILLUSTRATION SHIFT ACCU No.*** Current accumulation time ***** Current weight reading H**** Front four digits of total value L**** Rear four digits of total value SHIFT ***** Return Press TARE and ZERO can check different times weight and accumulation. 7 ACCUMULATION CLEAR OPERATION DISPLAY ILLUSTRATION CLEAR CLr Ask if you want to clear or not CLEAR noclr Cancel clear SHIFT 8.8.8.8.8. Confirm clear 8 BATTERY VOLTAGE OPERATION DISPLAY ILLUSTRATION SHIFT F1 U 6.** Display current battery voltage SHIFT Return The voltage should be between 5.8 and 6.9, if below than 5.8, the digits flash, you need to recharge immediately. 9 BRIGHTNESS OPERATION ILLUSTRATION F1 1~5 total 5 options, from darkness to brightness(default is 3) 10 ZERO POINT OPERATION ILLUSTRATION SHIFT ZERO Display current zero point USER MANUAL 8

CHAPTER 4 PARAMETER SETTING &CALIBRATION You need to use remote controller to operate parameter Setting and calibration Key function: KEY FUNCTION TARE Move digit(the digit choose flash) ZERO Set value up CLEAR Set value down SHIFT Confirm, exit 1. PARAMETER SETTING OPERATION DISPLAY ILLUSTRATION Press ON/OFF 3seconds 0 Turn on crane scale Press F1 and F2 at same time 3seconds P0000 Second digit flash,use function key to move digit, set value. Press TARE ZERO P8088 Input 8088,8088 is parameter setting password CLEAR Press SHIFT SETUP Confirm, enter parameter setting program Press TARE FS=06 New scale, the screen display FS=06,if scale calibrated,the screen display capacity. Press ZERO or FS=05 Choose capacity, the screen display CLEAR to choose 02/03/05/06/10/15/20/30/50/60/75 circularly, take cap:500kg as example, choose FS=05 Press TARE confirm Id=05 New scale, the screen display Id=05, if scale calibrated,the screen display calibrated division. Press ZERO or CLEAR to choose Press ZERO or CLEAR to choose Press TARE confirm Press TARE confirm Press ZERO or CLEAR to choose Id=02 Choose division,the screen display 01/02/05/10/20 circularly. 500kg scale division is 0.2kg, so choose Id=02 Pt=0 New scale, the screen display Pt=0, if scale calibrated,the screen display calibrated decimal position Pt=0 Choose decimal position, the screen display 0/1/2/3 circularly, 0=xxxxx, 1=xxxx.x, 2=xxx.xx, 3=xx.xxx, Cap.500kg scale choose Pt=1 Ab=24 Display zero range, A: zero range by hand; B: zero range automatically, 0~5 total 6 options: 0=0%F. S; 1=2%F.S; 2=4%F.S; 3=10%F.S; 4=20%F.S; 5=50%F.S,Generally,Don t change this parameter. Cd=11 New scale, the screen display Cd=11,if scale calibrated,the screen display calibrated value. Cd=11 C: zero-tracking range, 0~5 total 6 options; 0=0d; 1=0.5d; 2=1d; 3=1.5d; 4=2d; 5=2.5d d: display speed, 0~2 total 3 options; 0=slow; 1=average; 2=fast; before calibration, set Cd=00,after calibration, set Cd=11 again, generally choose Cd==11 when ex-stock.. USER MANUAL 9

Press TARE confirm LL=2 New scale,the screen display LL=2,if scale Press ZERO or CLEAR to choose calibrated,the screen display calibrated value. LL=1 LL:filter parameter,0~5 total 6 options, from smallest to biggest, before calibration, set LL=0,after calibration, set LL=1 again, generally choose LL=1 when ex-stock.. Press TARE confirm Un=0 New scale,the screen display Un=0, if scale Press ZERO or CLEAR to choose calibrated,the screen display calibrated unit. Un=0 Choose unit,un=0:kg, Un=1:lb, Un=2: other unit Generally, choose Un=0 when ex-stock. Press TARE confirm OFF 1 New scale,the screen display OFF 1,if scale Press ZERO or CLEAR to choose calibrated,the screen display calibrated value. OFF 2 Choose turn off method, 0~2 total 3 options; 0: turn off by hand; 1: if no operation, the screen display - after 15minutes to save power;2: if no operation, the screen display - after 15minutes, and turn off automatically after 60minutes. Generally, choose OFF=2 when ex-stock. Press TARE confirm g Acceleration of gravity Press TARE,Press ZERO and CLEAR to change value 9.7930 New crane scale, it display 9.7930, it our company local g, if scale calibrated, it display calibrated value. user can change it according to local area g value, the value range is 9.783-9.832, Press SHIFT End Confirm above parameter setting, Exit parameter setting program. 1. If you find mis-operation before end, Press TARE, the screen will display parameter circularly, correct error, and if you find mis-operation after parameter setting program finished, you have to enter parameter setting program again to correct. 2. The capacity you choose relate to division, decimal position, below is detail list: CAPACITY/DIVISION FS (CAP) Id (DIVISION) Pt(DECIMAL POSITION) 50kg/0.02kg 5 02 2 100kg/0.05kg 10 05 2 200kg/0.1kg 02 01 1 300kg/0.1kg 03 01 1 500kg/0.2kg 05 02 1 1000kg/0.5kg 10 05 1 USER MANUAL 10

2. calibration OPERATION DISPLAY ILLUSTRATION Press F1 and F2 at same time 3seconds Press TARE ZERO CLEAR 0 Take Cap:500kg scale as example,pay attention that the screen display 0 after hanging tare weight, you can hang tare weight at first, then turn on. P0000 Second digit flash,use function key to move digit, set value. P1358 Input 1358,1358 is calibration password Press SHIFT SCALE Confirm,into calibration program Press SHIFT CALSP Zero point calibration, wait until STB light on Press SHIFT LoAd1 First load calibration Hanging on first load e.g.100kg First load must exceed 20% capacity, Waiting until STB light on. Press SHIFT 500.0 Display capacity Press TARE ZERO CLEAR 100.0 Input 100, wait until STB light on. Press SHIFT LoAd2 Second load calibration Hanging on second load e.g.3000kg Second load must exceed Load 1+20% capacity, Waiting until STB light on. Press SHIFT 200.0 Mention you Load2 must exceed 200.0kg Press TARE ZERO CLEAR 300.0 Input actual weight 300.0, waiting stable Press SHIFT LoAd3 Third load calibration Hanging on third load e.g.5000kg Third load must exceed Load 2+20% capacity, Waiting until STB light on. Press SHIFT 400.0 Mention you Load3 must exceed 400.0kg. Press TARE ZERO CLEAR 500.0 Input actual weight 500.0kg. wait until STB light on. Press SHIFT ------ - Waiting stable -ol- End Calibration end 500.00 Display calibrated capacity, sometimes it display 499.95, 500.05 Press TARE 500.0 Move decimal position Put down weight 0 Check zero point, it display 0, and STB, ZERO light on. 1. First load: LOAD1 must larger than 20% capacity,and LOAD1<LOAD2<LOAD3, at the same time, between LOAD1 and LOAD2,LOAD2 and LOAD3, the interval must bigger than 20% capacity 2. If LOAD1 is bigger than 80% capacity, such as full capacity, after first load calibration, it will finish automatically, you only need to press TARE to move decimal position. Generally, we strong recommend you to use this one point calibration program if you have 100% capacity standard weight 2. If you only have 20% standard weight, after first load calibration, when it display LoAd2, press OFF 2 times, then press TARE to move decimal position. Calibration finish. USER MANUAL 11

CHAPTER 5 COMMUNICATION WITH Handphone This is android system! Android 2.0 1. Down load the APK software(everight-1-2p) to handphone 2. Running the software 3.Search and press icon BT-2015 4. Press icon CONNECT, handphone screen will display: USER MANUAL 12 ERT05.020 SSE

Press Connect a device-secure 5. Handphone screen will display: First time there are no paired devices inside, press Scan for device to search paired device. After the paired device display, press it. It will request you input device pin, you just input pin: 6666,then press enter. 6. The handphone screen will display It means crane scale have connected with handphone by bluetooth. Press setup,can go in parameter setting. Details refer to user manual. Calibration function prohibit so far. USER MANUAL 13 ERT05.020 SSE

CHAPTER 6 DISPLAY ILLUSTRATION DISPLAY ILLUSTRATION REMARK CALSP Enter zero point calibration SCALE Enter calibration SEtUP Enter parameter setting UAdJ Enter voltage calibration LoAd1 First calibration point LoAd1<LoAd2<LoAd3 LoAd2 Second calibration point LoAd3 Third calibration point Exceed high limit Tare weight can t exceed full capacity Exceed low limit Tare weight can t be negative ----- Waiting Err10 Weight less than Min. Capacity Can t accumulate the value Err11 Accumulated times overflow Can t accumulate after 30times Err12 Accumulated weight overflow Can t accumulate after 99999 Err13 Error in repeat accumulation Can t accumulate one weight repeatedly no*** Current accumulation times H**** Front four digit of accumulated Total weight=front four digit + rare four digit weight L**** Rare four digit of accumulated Total weight=front four digit + rare four digit weight CLr Ask if you really want to delete In case error deletion accumulated weight noclr Give up deletion 88888 Confirm deletion SHIFt Switch Input value is too large When you input tare or weight value Input value is too small When you input tare or weight value noacc No any accumulated content when you check accumulation -ol- Overload warning Tare + Net weight exceed full capacity + 9e -Lb- Low battery warning Turn off automatically one minute later U*.** The voltage of current battery End End when parameter setting or calibration ready OFF Turn off Unstb Input value before STB light on USER MANUAL 14

CHAPTER 7 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOUTION No display when put on Discharged battery Recharge Defective battery Replace Defective button Requires authorized service Power button not properly Press ON/OFF in depressed three seconds Digits flash Low battery Recharge the battery Recharge indicator light can t Battery charger damaged Check the battery turn on charger The Battery charger is not Insert plug again plugged properly Display doesn t respond to Faulty load cell or PCB Requires authorized weight changes service Load cell cable damaged Check and replace load cell Out of calibration Check calibration Display experiences Scale electronics do not After turning on, stabilize after turning on heating 3-5 minutes. excessive Zero drift between Put the scale on ground for Scale should be weighment too long time hung Displayed weight shows large Scale not Zeroed before Depress ZERO error applying weight before applying weight Requires recalibration See calibration Kg/lb wrong selection See operation Battery can t recharge Battery damaged Replace battery Outlet damaged Replace the outlet Remote distance shortened Receiver window is dirty Check and clean Remote Control s battery is Replace Remote low Control s battery. USER MANUAL 15