SWITCHES.CROUZET.COM MICROSWITCHES /8 SUB-SUBMINIATURE MICROSWITCHES - SEALED V5S - 83 High precision flexible leaf snap-action mechanism Operation without balance-point, even at extremely slow actuating speed Very small size Extra-long plunger stroke: mm overtravel to absorb dispersions in application Suitable for lateral approach from any direction with angle up to 5 Excellent resistance to harsh environments - IP67/IP69 protection Ratings from ma Vc to A 5 Va Long mechanical life Various terminal types and pre-wired models - Choice of flexible actuators Main specifications Standard 83 Low current 83 Function Connections / Locating pins I (changeover) X (PCB, straight) / none 833 833 I (changeover) X (PCB, straight) / CAV, CAR, LAV, LAR, C, L I (changeover) XL (PCB, straight, long) / none 83 83 I (changeover) XL (PCB, straight, long) / CAV, CAR, LAV, LAR, C, L I (changeover) X (PCB, rear) / CAR (two short, rear) 835 835 I (changeover) X (PCB, rear) / LAR (two long, rear) 833 833 I (changeover) X (PCB, rear) / none, CAV, LAV, C, L I (changeover) X3 (PCB, front) / CAV (two short, front) 836 836 I (changeover) X3 (PCB, front) / LAV (two long, front) 83 83 I (changeover) X3 (PCB, front) / none, CAR, LAR, C, L I (changeover) W (solder) / LAV (two long, front) 833 833 I (changeover) W (solder) / C (four, short) 8335 8335 I (changeover) W (solder) / none, CAV, CAR, LAR, L I (changeover) WST (solder, no hole) / none, CAV, CAR, LAV, LAR, C, L I (changeover) FB (wires, bottom) / CAR (two short, rear) 835 835 I (changeover) FB (wires, bottom) / C (four, short) 8355 I (changeover) FG (wires, left) / C (four, short) 836 I (changeover) FG (wires, left) / L (four, long) 8363 8363 I (changeover) FD (wires, right) / none 837 837 I (changeover) FD (wires, right) / C (four, short) 8369 I (changeover) FD (wires, right) / L (four, long) 837 I (changeover) FB, FG, FD / none, CAV, CAR, LAV, LAR, L R (normally closed) FB, FG, FD / none, CAV, CAR, LAV, LAR, C, L 83* 833* C (normally open) FB, FG, FD / none, CAV, CAR, LAV, LAR, C, L 83* 835* Electrical characteristics Rating nominal / 5 V AC (A) - Operating range / V AC/DC (A) -..5 Rating thermal (A) 5. Mechanical characteristics Max. operating force (N).5.5 Min. Release force (N)..5 Max. total travel force (N).5.5 Max. Allowable overtravel force (N) Max. rest position (mm).. Operating position (mm).5 ±,.5 ±, Max. differential travel (mm).5. Min. overtravel (mm) Ambient operating temperature ( C) - +9 - +9 Mechanical life (operations) 6 6 Contact gap (mm).3.6 Weight (terminal versions) (g).75.75 * Please contact us Additional specifications - Cover: PARA GF - Base: PA66 GF (UL 9-V / GWFI 96 C) - Button: POM - Membrane: silicone rubber - Moving blade: silver-plated beryllium copper - Contacts: silver alloy - Terminals: silver-plated brass - Wire leads: copper, PVC insulated - Levers: stainless steel - Degree of protection: IP67/IP69 (mechanism and wire output) - Protection against electric shock: button and actuators have reinforced insulation for Ui 5V / Uimp,5kV / pollution - Recommended min actuating speed:. mm/s - Certification marks: on request / Standard product Product made to order Contact us
SWITCHES.CROUZET.COM MICROSWITCHES /8 Product adaptations Principles Special connections: SMD terminals, special leads, cables, full wiring with custom connector Special levers: special shapes and lengths Fully customized switching modules with integrated connector Integration of resistors for specific electrical diagrams or self-diagnosis function Low switching hysteresis variant:.6 mm max differential travel Dual-current version with gold plated contacts for use from ma to A High operating temperature: +5 C curus approved versions - ENEC approval Single break snap-action switch Changeover - SPDT (form C) Normally closed - SPST-NC (form B) Normally open - SPST-NO (form A) Curves Electrical life Standard 83-5 Va A resistive > 6. cycles - Vc A resistive. cycles - Vc W lamps. cycles - Vc.5 A L/R = ms 5. cycles Dimensions Products 83 Version without locating pins 83 Version with locating pins Low-current 83-5 Vc ma resistive.. cycles, ±,5,8 ±, 7,5 ±, ±, 3,75 ±,,7 ±, 5,8 ±, 5,8 ±, R,5 ±, Ø.6 ±. on ribs 5, +, -,5 5,3 ±,,7 +, -, Total travel position: max 8.5 Locating pins,3 ±, Ø, ±,8 3 short pins on rear (CAR) short pins (C) 3 short pins on front (CAV) long pins on rear (LAR),5 ±, 9,53 ±,5 5 long pins (L) 6 long pins on front (LAV),3 ±, Ø, ±,8 5 6,9 ±, 9,53 ±,5
SWITCHES.CROUZET.COM 3 MICROSWITCHES /8 Recommendations for lateral approach 5 max. In order to reduce friction and wear, the actuating ramp shall preferably be of PA, POM, PBT or steel, and also be as smooth as possible. As a general rule, the use of any lubricant substance is not needed nor recommended. For particular cases, please consult us. 5 5 Connections X-XL for printed circuit board, straight output X for printed circuit board, rear output X3 for printed circuit board, front output,5 ±,5 3,6 ±, ±, 5,85 ±, ±,5,5,85 ±,,85 ±,,5 ±,5 5,85 ±, X = 3.5 ±. XL = 7 ±. W - WST solder CMS for surface mounting, rear output CMS3 for surface mounting, front output ±, 3,5 ±, 5,85 ±, 5,85 ±,,8 ±,,5 ±,5, ±,8, ±,8 With holes: W Ø.8 ±. Without holes: WST Please contact us Please contact us FB wire output on bottom FD wire output on right FG wire output on left 5,5,5 6 6,5 6 6,5 8 8 Wire characteristics : Black : Grey : Blue Cross-section:.35 mm Standard length: 5 mm Other lengths on request (length in meters: e.g..5)
,3 ±,3 SWITCHES.CROUZET.COM MICROSWITCHES /8 Drilling Installation on printed circuit board X-XL-X-X3 Installation on printed circuit board with locating pins 5,8 ±,5 3xØ,3 +, 5,85 ±,5,5 ±,5,6 +, 9,53 ±,5 Ø,5 ±,5 3xØ,3 +, 5,8 ±,5 5,8 ±,5 5,8 ±,5 9,86 ±,5 Actuators AF flexible flat lever FF flexible dummy roller lever Other shapes and dimensions: consult us R,7 ±, R F R,7 ±, R F R 3 ±, 8 ±, 8 ±,,5 ±, 3,6 ±,,5 ±, 3,6 ±, Operating position Mounting accessories Stainless steel mounting flange 6,5 ±. Ø 3, 5.5 ±. ±.,3 5,8 ±.
SWITCHES.CROUZET.COM 5 MICROSWITCHES /8 Actuators and mounting accessories Actuators Flexibles actuators Flat AF R5 Flat AF R Dummy roller FF R7 Max. operating force Min. release force Operating position (N) (N) (mm).5.. ±..3.5. ±..5..75 ±.5 Actuators are factory mounted Mounting accessories 79579 Stainless steel mounting flange Installation recommendations See Basic technical concepts How to order Use the 8 digit part numbers when they are defined Other cases, precise: Type and Function - Connection - Locating pins - Actuator* - Adaptation* + Mounting accessories* * if needed Example: 83 W CAV AF R5 + 79579 Examples of special adaptations IP67 module with 5 rotary operation, maintained action, integrated connector and quick fastening IP67 module with integrated connector and quick fastening Printed circuit board assembly with connector Special levers V size conversion housing and wire lead or cable output Customized wiring Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warrantly or any form of contractual commitment. Crouzet Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsability of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.