505 Series Low voltage DC, regulated, filtered. Step down transformer, fused primary and 6 heavy duty 505 shown with SBP2 KLC screw terminals. 12 VDC - 1 Amp, 24 VDC - 1 Amp, field selectable. Battery charging circuit. NEMA 1 enclosure - 12" H x 12" W x 4" D hinged cover with lock down screws. UL listed. Options/Accessories SBP1 Standby Battery 12VDC with Cable Kit (4 Amp/hour) SBP2 Standby Battery Pack 12/24VDC with Cable Kit (4 Amp/hour) PLC Power Line Cord 6 KLC Key Lock Cover CAB Cable Kit for Batteries 505DE Series Delayed Egress Controller The 505DE Series Delayed Egress Controller is designed to meet NFPA Life Safety Code 101- Special Locking Arrangements.The microprocessor also provides an integrated locking and access control system, which accepts TouchEntry readers or Keypads. UL listed. Options/Accessories PLC Power Line Cord 6 KLC Key Lock Cover SEC Security Alarm (requires door position switch) BOCA BOCA Code feature (requires door position switch) ATR Audit Trail Record REX100 Request to Exit Module, to signal external equipment MX500 Memory Expansion to 500 Users (TouchEntry ONLY) (Requires Computer Programming with CIP) 801TE* Local or remote monitoring station with TouchEntry for reset and legal release 801KS* Local or remote monitoring station with keyswitch for reset and legal release 804* Remote monitoring station for up to 4 stations 671 Touchbar to signal delay egress cycle 690 Smartbar to signal delay egress cycle 788C-16 4 conductor door cord, 16" armored cable w/24" wire *Use of monitoring devices requires the MBS option in lock. NOTE:These products require connection to AC line voltage. 510 Series Controller 12 and 24 VDC 12 VDC - 3 Amp, 24 VDC - 2 Amp, field 510 12/24VDC-KLC Basic Unit switchable regulated, Output power from screw terminals filtered Battery charging circuit. NEMA 1 enclosure - 12"H x 12"W x 4"D with hinged cover and lock down screws. Modular design provides for addition of plug in Dual Control Modules (DCM),Time Delay Modules (TDM), and Emergency Interface Relay Modules (EIR). UL listed Modular Options RCM Relay Control Module (Independent control of 2 DPDT relays) DCM Dual Control Module (Independent control of 1 or 2 independent stations) CMR Control Module Rack (Holds up to 3 Control Modules) TDM* Time Delay Module (adjustable relock time, 0-30 seconds, optional for each independent station). MR Manual Reset (for Canada) includes EIR option. KLC Key Lock Cover (for 510 or SBE enclosure) EIR Emergency Interface Relay Module *TDM can only be used with DCM or RCM option. Standby Power Accessories SBP2 Standby Battery Pack - 2 batteries with cables 24VDC 4 Amp/hr. or 12VDC 8 Amp/hr. SBE Standby Battery Enclosure - holds up to 8 batteries (required for more that 4 batteries) SBE-KLC Standby Battery Enclosure with Key Lock Cover 510-DCM3-TDM6-CMR1-EIR- SBP2-KLC Basic Unit with 3 dual control modules and control module rack. 299
515 Series Controller 12 or 24 VDC (specify voltage when ordering) This 515 Series Power Supply and its complete range of options are 515/12-KLC Basic Unit Output power from screw terminals available factory configured to your needs, or sold in modular components for custom assembly. 515 Basic - Specify 12VDC or 24VDC. Example: 515-12 for 12VDC 12 VDC - 10 Amp, 24 VDC - 5 Amp, regulated, filtered. Battery charging circuit. NEMA 1 enclosure - 12"H x 12"W x 4"D with hinged cover and lock down screws. Modular design provides for addition of plug in Dual Control Modules (DCM),Time Delay Modules (TDM), and Emergency Interface Relay Modules (EIR). UL listed Modular Options RCM Relay Control Module (Independent control of 2 DPDT relays) DCM Dual Control Module (Independent control of 1 or 2 independent stations) CMR Control Module Rack (Holds up to 3 Control Modules) TDM* Time Delay Module (adjustable relock time, 0-30 seconds, optional for each independent station). MR Manual Reset (for Canada) includes EIR option. KLC Key Lock Cover (for or SBE enclosure) EIR Emergency Interface Relay Module *TDM can only be used with DCM or RCM option. Standby Power Accessories SBP2 Standby Battery Pack - 2 batteries with cables 24VDC 4 Amp/hr. or 12VDC 8 Amp/hr. SBE Standby Battery Enclosure - holds up to 8 batteries (required for more than 4 batteries) SBE-KLC Standby Battery Enclosure with Key Lock Cover NOTE: These products require connection to AC line voltage. 515/12-DCM6-TDM12-CMR2-EIR- KLC. Basic Unit with 6 dual control modules with 2 control racks. 564SS Series Power Control Unit Provides for variations in access control hook-up switch selectable Includes isolated fire panel tie in feature One half second delay for automatic door operator Interface for one door station only. 1.0 Amp maximum output, 24VDC non-regulated. Options FA Manual Reset Fire Alarm Circuit KLC Key Locked Cover 590 Series Transformers Hard Wired 12 and 24 Volts, 40 VA 591-24 24 Volt AC Output - 1.67 Amp max. - UL Listed 592-12/24 12/24 Volt AC Output - Center Tap 40VA 592-12 12 Volt AC Output - 3.3 Amp max. 592-12RC 12 Volt DC Output - 3.3 Amp max. 592-24 24 Volt AC Output - 1.67 Amp max. 592-24RC 24 Volt DC Output - 1.67 Amp max. Plug-in 12 and 24Volts, UL listed 593 PI-12 12 Volt AC Output - 1 Amp max. 593 PI-12DC 12 Volt DC Output - 1 Amp max. 593 PI-24 24 Volt AC Output - 1 Amp max. 593 PI-24DC 24 Volt DC Output - 0.5 Amp max. 5000 Series Interface Relays 5300 Time Delay Relock - 0 to 120 sec. electronic time delay 12 or 24 VAC-DC 5400 Intercom interface module 12-24 VAC-DC 6000 Series Automatic Time Clocks 6100 24 hour timer 6101 w/on omitting device 6200 24 hour - 7 day - digital electronic timer 6060-24 0-60 second or minute timer Rectifiers Hard Wired Plug-in RCP Rectifier prewired, 12 or 24 volt operation RC1 Rectifier prewired with filter capacitor 300 Toll Free: (800) 221-2052 Phone: (718) 622-8785 Fax: (718) 789-8346 http://www.mfsales.com e-mail: pilgrim@mfsales.com
Options for 510 & 515 Power Supplies The unique Locknetics Dual Control Module (DCM) system now makes it more convenient than ever to power electronic locking systems. Each Dual Control Module (DCM) provides control of two individual zones. Each one has a 5 Amp DPDT control relay. A single DCM card can plug directly to the main board or a Control Module Rack (CMR) can plug into the main board and accept up to three DCM cards.this upgrade is ideal for interlock applications. A plug in Time Delay Module (TDM), providing an adjustable (0-30 seconds) delay on relock, can be added to each individual zone of the DCM card. The Emergency Interface Relay Module (EIR) is a plug-in relay to provide an interface with fire or other emergency override systems. EIR TDM 510 Or Basic 515 unit with 6 Dual Control Modules and 2 Control Module Racks CMR DCM Note: Total Amps of lock and accessories must be less than or equal to noted current available at the power supply. 510 Series Each 510 is prepped to accept one Dual Control Module (DCM) directly mounted to the box or a Control Module Rack (CMR), which holds up to 3 each DCM. DCM AVAILABLE ZONES CMR (REQUIRED AS SHOWN) TDM EIR 0 - BASIC N/A 0 0 0 or 1 1 2 0 or 1 (for expansion) Up to 2 0 or 1 2 4 1 Up to 4 0 or 1 3 6 1 Up to 6 0 or 1 515 Series Each 515 is prepped to accept two DCM s directly mounted to the box, or up to two CMR s (which holds up to 6 each DCM s) or one DCM and one CMR. DCM AVAILABLE ZONES CMR (REQUIRED AS SHOWN) TDM EIR 0 - BASIC N/A 0 0 0 or 1 1 2 0 or 1 (for expansion) Up to 2 0 or 1 2 4 0 or 1 (for expansion) Up to 4 0 or 1 3 6 1 Up to 6 0 or 1 4 8 1 or 2 Up to 8 0 or 1 5 10 2 Up to 10 0 or 1 6 12 2 Up to 12 0 or 1 Current Capacity: and Lock Selection Maximum Number Of Electromagnetic Locks For Each Pentagon Lock Series: Pentagon Powermiser 263 268 280/ 290 320 380 390 Amps @ 12V.80.40.68.68.90.22.16.67 @ 24V.50.35.35.45.45.35 : 505-1 Amp @ 12V 1 2 1 1 1 4 5 1 505-1 Amp @ 24V 2 0 2 2 2 1 0 2 510-3 Amp @ 12V 3 6 3 3 3 12 16 3 510-2 Amp @ 24V 4 0 5 5 4 3 0 5 515-10 Amp @ 12V 12 24 12 12 11 40 55 12 515-5 Amp @ 24V 10 0 12 12 11 9 0 12 Lock Series: 401 405 437 431 440S 490 9000 Amps @ 12V.90.90.90.90.50.45 @ 24V.45.45.45.45.25.10.25 : 505-1 Amp @ 12V 0 0 0 0 1 0 1 505-1 Amp @ 24V 1 1 1 1 3 10 3 510-3 Amp @ 12V 2 2 2 2 5 0 5 510-2 Amp @ 24V 3 3 3 3 6 20 6 515-10 Amp @ 12V 9 9 9 9 17 0 19 515-5 Amp @ 24V 9 9 9 9 17 50 17 301
500 Series Standby Battery Selection Chart Select, 505, 510 or 515 Series. Determine current load of draw in amps. Determine voltage to be used. Determine standby time in hours desired Choose the number of SBP 2 s and SBE s to achieve the desired standby time. SBP2 Standby Battery Pack 505 Series Standby Time In Hours IN AMPS HRS. HRS. HRS. HRS. 1.0 6 12 3 6.50 12 24 6 12.33 24 48 12 24.22 36 72 18 36.16 48 96 24 48 NO. OF SBP2 s Required 1 2 1 2 510 Series Standby Time In Hours IN AMPS HRS. HRS. HRS. HRS. HRS. HRS. HRS. HRS. 3.0 2 4 6 8 2.0 3 6 9 12 1.5 3 4.5 6 1.0 6 12 18 24 3 6 9 12.50 12 24 36 48 6 12 18 24.33 24 48 72 96 12 24 36 48.22 36 72 108 144 18 36 54 72.16 48 96 144 192 24 48 72 96 NO. OF SBP2 s Required 1 2 3 4 1 2 3 4 NO. OF SBE s Required 0 0 1 1 0 0 1 1 515 Series Standby Time In Hours IN AMPS HRS. HRS. HRS. HRS. HRS. HRS. HRS. HRS. SBE Standby Battery Enclosure 10.0.20.40.60.80 8.0.44.88 1.3 1.8 5.0.84 1.7 2.6 3.4.42.84 1.3 1.7 4.0 1.2 2.4 3.6 4.8.6 1.2 1.8 2.4 2.0 3 6 9 12 1.5 3 4.5 6 1.0 6 12 18 24 3 6 9 12.50 12 24 36 48 6 12 18 24.25 36 72 108 144 18 36 54 72 NO. OF SBP2 s Required 1 2 3 4 1 2 3 4 NO. OF SBE s Required 1 1 1 1 1 1 1 1 302 Toll Free: (800) 221-2052 Phone: (718) 622-8785 Fax: (718) 789-8346 http://www.mfsales.com e-mail: pilgrim@mfsales.com
Current Capacity: Power supply and lock selection SUGGESTED MAXIMUM NUMBER OF ELECTROMAGNETIC LOCKS FOR EACH POWER SUPPLY MAGFORCE MAGFORCE PENTAGON 280+/ 390+SM 350+ 390+ 390+/390B SERIES POWERMISER GF3000 SERIES SERIES SERIES POWERMISER Amps @12V 0.80 0.40 0.90 1 0.75 0.67 0.16 @24V 0.50 N/A 0.45 0.5 0.38 0.35 N/A 505-1 Amp @12V 1 2 1 0 1 1 6 505-1 Amp @ 24V 1 0 2 1 2 2 N/A 510-3 Amp @12V 3 6 3 2 3 4 18 510-2 Amp @ 24V 3 0 4 3 5 5 N/A 515-10 Amp @12V 12 24 11 9 13 14 55 515-5 Amp @ 24V 9 0 11 9 12 14 N/A SUGGESTED MAXIMUM NUMBER OF ELECTROMAGNETIC LOCKS/ ELECTRONIC STRIKES FOR EACH POWER SUPPLY 401 405 432 442S 490 Amps @12V 0.90 0.90 0.90 0.50 @24V 0.45 0.45 0.45 0.25 0.10 505-1 Amp @12V 1 1 1 1 0 505-1 Amp @ 24V 2 2 2 3 9 510-3 Amp @12V 2 2 2 5 0 510-2 Amp @ 24V 4 4 4 7 18 515-10 Amp @12V 10 10 10 17 0 515-5 Amp @ 24V 10 10 10 17 48 Note: Total Amps of lock and or accessories must be less than or equal to noted current available at the power supply. 303