Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Similar documents
Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

Power Supplies. Automation & Sensing. Selection Guide

Power Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.

PS6R 480W Switching Power Supply

PS5R-S. Switching Power Supplies

GT5P Series ON Delay Timers

Switching Power Supply

Power Supplies. Automation & Sensing.

Switching Power Supplies

Switching Power Supplies

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Switching Power Supply

PRODUCTS: POWER SUPPLY

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Relays & Sockets. RQ Series PCB Relays

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

RoHS-Compliant Brushless Motor Systems FBL Series. Features

POWER-WIN TECHNOLOGY CORP.

General Purpose Relay

TDK-Lambda ZWS240BP/A SPECIFICATIONS

Terminal Blocks. Selection Guide. Selection Guides. P-2 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC

Oiltight Switches & Pilot Devices

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

A22NK. Key-type Selector Switches

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

D R C- 4 0 s e r i e s

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

Terminal Blocks. BNH/BN Terminal Blocks. BNH/BN Series. Specifications. USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC P-3

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Surface mounting, flush mounting, and DIN track mounting

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

Industrial Relay KML(1C, 2C)

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Model Number Structure

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Digital display Pressure range ON/OFF output Linear output Model

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

DC/DC converters - MINI-PS DC/ 5-15DC/

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Model Number Structure

General Purpose Relay

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

AC Motor Systems US Series

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Isolated and rugged 24 Vdc power for battery powered electronic control systems on rail equipment

GB60S 60W Single Output General Purpose Series

Section. Terminal Blocks Selection Guides...P-2

Brushless DC Motor Systems FBL2 Series

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Lexium integrated drives

22mm XW E-Stops. UL File #E68961 CCC No Specifications

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

ø22mm HW Series Control Units Control Units

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Model Number Structure

TDK-Lambda ZWS300BAF/A

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

DBC-1 DEIF Battery Charger

Switching Power Supplies

Open Frame Power Supplies

S8VK-S (30/60/120/240/480-W Models)

POWER-WIN TECHNOLOGY CORP.

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

LS200 Series Instruction Manual

RWS50B RWS100B RWS150B RWS300B RWS600B

Lexium integrated drives

Totally Sealed Hour Meter

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

This document provided by Barr-Thorp Electric Co., Inc

Ordering Information. Text PCB Power Relay G5LE

Relays & Sockets. RV8 Series 6mm Interface Relays. (when using combination of RV relay and SV socket) RV8H Electromechanical Part Numbers

Terminal Blocks. Switching & Controls.

AC Motor Systems. Speed Control Systems B-137. Speed Control Systems Introduction. BHF Series FE200 ES01/ US Series

RU Series Universal Relays

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

DRB-1 Series Instruction Manual

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Model Number Structure

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

55 Series - Miniature General Purpose Relays 5-10 A

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

ZWD100PAF. Conformity to RoHS Directive

Switches & Pilot Devices

MD60 Series 60W DINergy Power Supply

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Scheda prodotto Relè Series B

Transcription:

Standard Series Standard Series Switching Part Numbers Part Number Item Watts Rated Voltage Rated Current -A V DC 1.A -A 7. V DC.6A -A24 24V DC.3A -B V DC 2.A Key features of the standard series include: Wide Power Range: 7.W-24W Universal Input: 7.W-W:8-264V AC/1-37V DC 1W:1-V AC/2-24V AC (Selectable) 24-37V DC W-24W:8-264V AC/1-37V AC Fused Input Overcurrent/Overvoltage Protection Power Factor Correction (W, W, 24W models) EN61-3-3 EN61-3-2 Voltage adjustment + 1% Spring-up Screw Terminal, IP2 (finger-safe) DIN rail or Panel Surface Mount Approvals: CE marked U 8 isted U, c-u TÜV approved EMC Directives: EN81-2 EN82-2 EN61-6-2 VD EN9:2 -B 1 V DC 1.2A -B24 24V DC.6A -C V DC 2.A 3 -C24 24V DC 1.3A -D24 24V DC 2.1A -Q24 24V DC 3.1A U 8 isted File # E177168 Cert. No. B982332392 -E24 1 24V DC 4.2A -F24 24V DC A -G24 24 24V DC 1A -8 www.idec.com USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC

Standard Series Specifications Specifications Part Numbers Input Output VDC output -A -B* VDC output -A -B -C 24VDC output -A24 -B24 -C24 -D24 -Q24 -E24 -F24 -G24 Output Capacity 7.W 1W 3W W W 1W W 24W Input Voltage (single-phase, 2-wire) Input Current (typical) 1 to 24VAC nominal (8 to 264V AC), /Hz (47 to 63Hz) 11 to 34VDC nominal (1 to 37VDC).17A at 1VAC.3A at 1VAC.68A at 1VAC 1.1A at 1VAC 1.1A 1 to VAC, /Hz 2 to 24VAC, /Hz (jumper selectable) 24 to 37VDC 2.A at 1VAC 1.A at 2VAC 1 to 24VAC, /Hz, 11 to 34VDC 1.8A 4A at 1VAC Internal Fuse Rating 2A 2A 3.1A 3.1A 3.1A 4A 4A 6.3A Inrush Current A maximum (at cold start at 2V AC) 7A maximum (at cold start at 23V AC) A maximum (at cold start at 2V AC) eakage Current (at no load).ma maximum (Hz, measured in conformance with U, CSA, VDE) Typical Efficiency 69% at V 69% at V 73% at V % at V % at V % at 24V 79% at 24V % at 24V 79% at 24V 83% at 24V DC 8% at 24V 83% at 24V DC Overvoltage Protection Outputs turns off at 1% (typical) Voltage and Current Ratings V, 1.A V,.6A 24V,.3A V, 2.A V, 1.2A 24V,.6A 7A maximum (at cold start at 23V AC) 83% at 24V V, 2.A 24V, 1.3A 24V, 2.1A 24V, 3.1A 24V, 4.2A 24V, A 24V, 1A Voltage Adjustments ±1% ( screw on top) Output Holding Time 2ms minimum (at full rated input and output) Rise Time 2ms maximum (at full rated input and output) 1ms max. ine Regulation.4% maximum oad Regulation 1.% maximum Fluctuation due to Ambient Temperature Change.% maximum Ripple Voltage 2% peak to peak maximum (including noise) Overload Protection % typical (Zener-limiting) % typical, auto reset Operation Indicator ED Parallel Operation Dielectric Strength Insulation Resistance Operating Temperature Storage Temperature Operating Humidity -A -B -C -D -Q -E -F -G No Yes No Yes Between input and output terminals: 3,V AC, 1 minute Between input terminals and housing: 2,V AC, 1 minute Between output terminal and housing: V AC, 1 minute Between input and output terminals/input terminals and housing: 1MΩ minimum (V DC megger) 1 to + C (14 to 14 F) (see derating curves) 3 to +8 C (-22 to 18 F) 2 to 9% relative humidity (no condensation) Vibration Resistance 4m/s 2, 1 to Hz, 2 hours on each of 3 axes 1 to Hz,.mm p-p, 2 hrs on each of 3 axes Shock Resistance 3m/s 2 (3G), 3 shocks in each of 6 directions Approvals Conforms to EMC Directives EN81-2 & EN82-2. VD Directive EN29 Certified to EN9. U8 listed. U, c-u, TUV approved. CE marked. EN61-3-2 Weight 1g 17g 3g 39g 8g g g 2g Termination Spring-up, fingersafe terminals with captive M3. screws IP protection IP2 (finger safe) Dimensions H x W x D (mm) x 4 x 7 x 4 x9 x 9 x 9 Dimensions H x W x D (inches) 2.9 x 1.77 x 2.76 2.9 x 1.77 x 3.74 2.9 x 3.4 x 3.74 x 9 x 9 2.9 x 3.4 x 3.74 x 8 x 14 x 14 x 9 x 11 x14 x 2x 14 4.72 x 3.3 x.2 2.9 x.71 x 3.74" 4.72 x 4.3 x.2 4.72 x 7.87 x.1 1. For dimensional drawings, see page -. 2. For usage instructions, see page -11. 3. *.W for VDC model. www.idec.com USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC -9

Standard Series Temperature Derating Curves -A/B -C/D 1 9 8 7 4 3 2 1 1 1 2 3 4 1 9 8 7 4 3 2 1 1 1 2 3 3 4 -E -Q 1 9 8 7 4 3 2 1 1 1 2 3 4 -F/G A Mounting B Mounting 1 9 8 7 4 3 2 1 1 2 3 3 4 Operating Temperature ( C) Mounting Style B Mounting Style A Mounting Style A (standard) 1 9 8 7 4 3 2 1 1 2 3 4 Vertical Operating Temperature ( C) Mouting style A Mounting Style B (Facing upward) Vertical -1 www.idec.com USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC

Standard Series Accessories Part Numbers: Accessories Appearance Description Part Number DIN rail (1mm) BNDN1 DIN rail end clip BN Installation Instructions Time-Saving Spring-up Terminals The innovative terminals on the series use a special, spring-loaded screw. This makes installation as easy as pushing down and turning with a screwdriver. Installation time is cut in half since the screws do not need to be backed out to install wiring. The screws are held captive once installed and are 1% finger-safe. Screw terminals accept bare wire or ring or fork connectors. 1. Insert the wire connector into the slot on the side of the power supply. Overcurrent Protection Characteristics 2. Using a Phillips screwdriver, push down and turn the screw. -A/B -C/D/E 1 1 Output Voltage (%) Output Voltage (%) The wire is now connected, and the screw terminal is finger-safe! Front Panel (terminals) Terminal Name Description V. ADJ +V, V, N NC Voltage adjustment Operation indicator DC output terminals Frame ground Input terminals No connection Adjusts within ±1%; turn clockwise to increase output voltage Green ED is lit when output voltage is on +V: Positive output terminal V: Negative output terminal Ground this terminal to reduce high-frequency currents caused by switching Accept a wide range of voltages and frequencies (no polarity at DC input) Do not insert wires here, as this may damage the power supply Parallel Operation 1 +V (24V) -V (V) TERMINAS 1 EECTRIC OAD Parallel operation only recommended for -Q24, -F24 and -G24. www.idec.com USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC -11

Standard Series Dimensions -A (7.W). mm 4. mm 7. mm -B (1W). mm 4. mm 9. mm 62. 62. R2.2 6-ø6. 3 38. R2.2 6-ø6. 3 38. -C (3W) -D (W) 1-ø6. 9 8 1-ø6. 9 8. mm 9. mm 9. mm.mm 9.mm 9.mm -Q (W) -E (1W) 11 11. mm 8. mm 14. mm 14 14-ø6.. mm 14. mm 9. mm 8 -F (W) 16 4.6 -G (24W) 26 2-24V 11 11. mm 11. mm 14. mm 11.mm 2.mm 14.mm 1 11 19 2 - www.idec.com USA: (8) 262-IDEC or (48) 747-, Canada: (888) 317-IDEC