DEVELOPMENT AND VALIDATION OF A TRACTOR DRAWBAR FORCE MEASUREMENT AND DATA ACQUISITION SYSTEM (DAQ)

Similar documents
Tractor hydraulic power data acquisition system

PREDICTION OF FUEL CONSUMPTION

Predicting Tractor Fuel Consumption

Fuel Consumption Models for Tractor Test Reports

Wide Tires, Narrow Tires

Weight, Transfer, Traction, and Safety 423

Fuel Consumption Models for Tractors with Partial Drawbar Loads

EVALUATION OF THE ACCURACY OF MACHINE REPORTED CAN DATA FOR ENGINE TORQUE AND SPEED

AN EVALUATION OF AGRICULTURAL TRACTORS HYDRAULIC LIFT PERFORMANCE

Development and Evaluation of Tractors and Tillage Implements Instrumentation System

Testing the Fuel Efficiency of Tractors with Continuously Variable and Standard Geared Transmissions

Modeling of Radial-Ply Tire Rolling Resistance Based on Tire Dimensions, Inflation Pressure and Vertical Load

Modeling of Rolling Resistance for Bias-Ply Tire Based on Tire Dimensions, Inflation Pressure and Vertical Load

Wind Turbine Emulation Experiment

Experimental Measurement of Frictional Torque in End Pivoted Roller Finger Follower Valve Train

Prediction of Bias-Ply Tire Deflection Based on Contact Area Index, Inflation Pressure and Vertical Load Using Linear Regression Model

Modeling of Contact Area for Radial-Ply Tire Based on Tire Size, Inflation Pressure and Vertical Load

NEBRASKA OECD TRACTOR TEST 2181 SUMMARY 1105 CLAAS AXION 840 DIESEL CONTINUOUSLY VARIABLE TRANSMISSION

NEBRASKA OECD TRACTOR TEST 2183 SUMMARY 1107 CLAAS AXION 880 DIESEL CONTINUOUSLY VARIABLE TRANSMISSION

The Deployable Gage Restraint Measurement System - Description and Operational Performance

A Cost Effective Method to Create Accurate Engine Performance Maps & Updating the Nebraska Pumping Plant Performance Criteria

TRACTOR MFWD BRAKING DECELERATION RESEARCH BETWEEN DIFFERENT WHEEL DRIVE

LABORATORY AND FULL BOOM-BASED INVESTIGATION OF NOZZLE SETUP ERROR EFFECTS ON FLOW, PRESSURE, AND SPRAY PATTERN DISTRIBUTION

Oscillator Experiment of Simple Girder Bridge coupled with Vehicle

NEBRASKA OECD TRACTOR TEST 2189 SUMMARY 1091 KUBOTA M7-151 DIESEL 24 SPEED

Oregon DOT Slow-Speed Weigh-in-Motion (SWIM) Project: Analysis of Initial Weight Data

Investigating the effect of dynamic load on rolling resistance of agricultural tractor tire

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

Monitoring of Shoring Pile Movement using the ShapeAccel Array Field

NEBRASKA OECD TRACTOR TEST 2086 SUMMARY 935 CASE IH MAGNUM 370 DIESEL CVT TRANSMISSION

EXTRACT of chapter XXXIV coupling devices (version of ) ANNEX XXXIV Requirements on mechanical couplings

NEBRASKA OECD TRACTOR TEST 1996 SUMMARY 771 CASE IH MAGNUM 225 DIESEL CONTINUOUSLY VARIABLE TRANSMISSION

NEBRASKA OECD TRACTOR TEST 1929A SUMMARY 601A CHALLENGER MT955B DIESEL ALSO CHALLENGER MT955C DIESEL 16 SPEED

Tractor Performance Monitors optimizing tractor and implement dynamics in tillage operations - one year of field tests

Development of an Instrumentation System for Evaluating the Tractive Performance of Walking Tractors

LESSON Transmission of Power Introduction

NEBRASKA OECD TRACTOR TEST 2150A SUMMARY 1013A NEW HOLLAND T8.435 SMARTTRAX DIESEL CVT TRANSMISSION

INSTRUCTION MANUAL ANCHOR LOAD CELL. Model ANCLO

NEBRASKA OECD TRACTOR TEST SUMMARY 1050 CHALLENGER MT875E DIESEL 16 SPEED

POST-WELD TREATMENT OF A WELDED BRIDGE GIRDER BY ULTRASONIC IMPACT TREATMENT

TRINITY COLLEGE DUBLIN THE UNIVERSITY OF DUBLIN. Faculty of Engineering, Mathematics and Science. School of Computer Science and Statistics

Installation Instructions Model Geobeam

Chapter 4. Vehicle Testing

Non-Linear Implicit Analysis of Roll over Protective Structure OSHA STANDARD (PART )

Nowaday s most of the agricultural operations are

Load Cells. For Test, Measurement, and Monitoring Requirements in Automotive, Aerospace, R&D, and Process Control Applications

Analysis and evaluation of a tyre model through test data obtained using the IMMa tyre test bench

Surface- and Pressure-Dependent Characterization of SAE Baja Tire Rolling Resistance

NEBRASKA OECD TRACTOR TEST 1931A SUMMARY 603A CHALLENGER MT975B DIESEL ALSO CHALLENGER MT975C DIESEL 16 SPEED

TESTING THE UNIFORMITY OF SPRAY DISTRIBUTION UNDER DIFFERENT APPLICATION PARAMETERS

PHYS 2212L - Principles of Physics Laboratory II

RETROFIT OF A ROLLER BRAKE TESTER AT FAMENA

SEAT BELT LOAD CELL. Load cell that measures the forces at the seat belt during automotive crash or sled tests.

NEBRASKA OECD TRACTOR TEST 1964 SUMMARY 661 CHALLENGER MT865C DIESEL 16 SPEED

Comparison of 2-way versus metered 3-way boom shut-off valves for automatic section control on agricultural sprayers

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

NEBRASKA OECD TRACTOR TEST 2017A SUMMARY 816A CASE IH MAGNUM 235 DIESEL 18 SPEED

Skid against Curb simulation using Abaqus/Explicit

RoaDyn S635 System 2000

Virtual Durability Simulation for Chassis of Commercial vehicle

Dennis Buckmaster. Agricultural & Biological Engineering. Agricultural & Biological Engineering

NEBRASKA OECD TRACTOR TEST 2078 SUMMARY 894 JOHN DEERE 6125M POWRQUAD-PLUS DIESEL 24 SPEED

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

44 March, 2015 Agric Eng Int: CIGR Journal Open access at Vol. 17, No. 1

Permanent Multipath Clamp-On Transit Time Flow Meter

NEBRASKA OECD TRACTOR TEST 2079 SUMMARY 895 JOHN DEERE 6140M POWRQUAD-PLUS DIESEL 24 SPEED

Using Tractor Test Data for Selecting Farm Tractors

Quasi-Static Finite Element Analysis (FEA) of an Automobile Seat Latch Using LS-DYNA

Definition of Unambiguous Criteria to Evaluate Tractor Rops Equivalence

Relating Pull Forces and Power Consumption on Small Scale Autonomous Vehicles

MCRT 27000T Non-Contact WHEEL TORQUEMETERS (TORQUE WHEELS) Designing and Making the World s Best Torque Instruments Since 1960

NEBRASKA OECD TRACTOR TEST 2172 SUMMARY 1086 JOHN DEERE 8400R DIESEL e23 TRANSMISSION

NEBRASKA OECD TRACTOR TEST 2173 SUMMARY 1087 JOHN DEERE 9570RX DIESEL 18 SPEED

NEBRASKA OECD TRACTOR TEST 1887 SUMMARY 554 JOHN DEERE 8330 DIESEL 16 SPEED

CHECK AND CALIBRATION PROCEDURES FOR FATIGUE TEST BENCHES OF WHEEL

Precision Load Cells. The World of Precision Made Force Transducers. A world of experience TEST AND MOTION SIMULATION

MODELING SUSPENSION DAMPER MODULES USING LS-DYNA

WSS/WSS-L White paper

Assemblies for Parallel Kinematics. Frank Dürschmied. INA reprint from Werkstatt und Betrieb Vol. No. 5, May 1999 Carl Hanser Verlag, München

NEBRASKA OECD TRACTOR TEST 2135 SUMMARY 1005 JOHN DEERE 9620R DIESEL 18 SPEED

String Monitoring and Control System for Solar Photo Voltaic Power Plants

NEBRASKA OECD TRACTOR TEST 1890 SUMMARY 557 JOHN DEERE 8530 DIESEL INFINITELY VARIABLE TRANSMISSION

CALIBRATION PROCEDURE NI Channel, ±0.5 V, 24-Bit Simultaneous, Channel-to-Channel Isolated Analog Input Module

DISPLAYING OF TRACTOR PERFORMANCE

Analysis on Steering Gain and Vehicle Handling Performance with Variable Gear-ratio Steering System(VGS)

NEBRASKA OECD TRACTOR TEST 1926 SUMMARY 596 JOHN DEERE 9630 DIESEL 18 SPEED

What is the secret to our success?

Headlight Test and Rating Protocol (Version I)

CALIBRATION PROCEDURE NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

A Simple Method for Estimating the Driving Resistance of Rubber Conveyer Belts by Using a Self-traveling Roller

Increased Deflection Agricultural Radial Tires Following the Tire and Rim Association IF, VF, and IF/CFO Load and Inflation Standards

Assessment of Dynamic Load Equations Through Drive Wheel Slip Measurement

Using MATLAB/ Simulink in the designing of Undergraduate Electric Machinery Courses

Section 5. Traffic Monitoring Guide May 1, Truck Weight Monitoring

NEBRASKA OECD TRACTOR TEST 2040 SUMMARY 831 JOHN DEERE 9460R DIESEL 18 SPEED

Motor-CAD End Winding Spray Cooling Model

SUMMARY OF OECD TEST 2423 NEBRASKA SUMMARY 621 CASE IH PUMA 180 DIESEL 19 SPEED

XVII th World Congress of the International Commission of Agricultural and Biosystems Engineering (CIGR)

NEBRASKA OECD TRACTOR TEST 1973 SUMMARY 734 JOHN DEERE 8345RT DIESEL INFINITELY VARIABLE TRANSMISSION

Laboratory and Full Boom-Based Investigation of Nozzle Setup and Restriction Effects on Flow, Pressure and Spray Pattern Distribution

Transcription:

University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Biological Systems Engineering: Papers and Publications Biological Systems Engineering 2017 DEVELOPMENT AND VALIDATION OF A TRACTOR DRAWBAR FORCE MEASUREMENT AND DATA ACQUISITION SYSTEM (DAQ) James Roeber University of Nebraska-Lincoln, roeber.james90@huskers.unl.edu Santosh Pitla University of Nebraska-Lincoln, spitla2@unl.edu Roger M. Hoy University of Nebraska-Lincoln, rhoy2@unl.edu Joe D. Luck University of Nebraska-Lincoln, jluck2@unl.edu Michael F. Kocher University of Nebraska-Lincoln, mkocher1@unl.edu Follow this and additional works at: https://digitalcommons.unl.edu/biosysengfacpub Part of the Acoustics, Dynamics, and Controls Commons, Bioresource and Agricultural Engineering Commons, Environmental Engineering Commons, and the Other Civil and Environmental Engineering Commons Roeber, James; Pitla, Santosh; Hoy, Roger M.; Luck, Joe D.; and Kocher, Michael F., "DEVELOPMENT AND VALIDATION OF A TRACTOR DRAWBAR FORCE MEASUREMENT AND DATA ACQUISITION SYSTEM (DAQ)" (2017). Biological Systems Engineering: Papers and Publications. 517. https://digitalcommons.unl.edu/biosysengfacpub/517 This Article is brought to you for free and open access by the Biological Systems Engineering at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in Biological Systems Engineering: Papers and Publications by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln.

TECHNICAL NOTE: DEVELOPMENT AND VALIDATION OF A TRACTOR DRAWBAR FORCE MEASUREMENT AND DATA ACQUISITION SYSTEM (DAQ) J. B.W. Roeber, S. K. Pitla, R. M. Hoy, J. D. Luck, M. F. Kocher ABSTRACT. Matching agricultural tractors to implements towed by the drawbar is one of the important aspects of machinery management for ensuring optimum performance and fuel cost savings. A field deployable tractor draft force measurement and data acquisition system was developed and evaluated as part of this research project. A drawbar instrumented to measure draft force in field operating conditions was developed and statically calibrated. The drawbar was calibrated by applying loads from 4.45 to 134 kn using a hydraulic cylinder connected to a 444.8 kn load cell. Testing was conducted with the drawbar installed on a tractor on a concrete track. The Nebraska Tractor Test Laboratory (NTTL) load car was used for applying draft loads to evaluate the instrumented drawbar. The track test consisted of seven loads corresponding to maximum power in seven gears. The draft forces as measured by the drawbar were compared to the draft measurements recorded by the load car. The error between draft force measurements of the instrumented drawbar and the load car measurements ranged from 0.21 kn (0.27%) to 0.99 kn (2.88%).There were no statistically significant differences between drawbar and load car measurements confirming that the drawbar force measurement and data acquisition (DAQ) system developed as part of this research can be used for field use. Keywords. Data acquisition, Draft load, Drawbar, LabVIEW, Strain gages, Tractor. The tractor drawbar is the most widely used method of towing an implement. An accurate robust method to measure the draft load developed by a towed implement had been a critical industry need for some time. Tractor tests were conducted as far back as 1908 in the Winnipeg Tractor Trials (Ellis, 1913). Some approaches for draft force measurement have included: attaching a strain gage load cell to the drawbar; or a hydraulic cylinder acting as a load cell (used by the Nebraska Tractor Test Laboratory (NTTL) for official drawbar draft measurements until being replaced by load cells in 2011); installing an instrumented drawbar pin (Zoerb et al., 1983); or instrumenting the drawbar itself (Grevis-James and Bloome, 1982). A primary benefit of these types of sensors was to Submitted for review in June 2017 as manuscript number MS 12489; approved for publication as a Technical Note by the Machinery Systems Community of ASABE in September 2017. The authors are James B.W. Roeber, Graduate Student, Santosh K. Pitla, ASABE Member, Assistant Professor, Roger M. Hoy, ASABE Member, Professor, Joe D. Luck, ASABE Member, Assistant Professor, and Mike F. Kocher, ASABE Member, Associate Professor, Department of Biological Systems Engineering, University of Nebraska-Lincoln, Lincoln, Nebraska. Corresponding author: Santosh K. Pitla, 207 L.W. Chase Hall, University of Nebraska-Lincoln, Lincoln, NE 68583; phone: 402-472-1466; e-mail: spitla2@unl.edu. minimize alterations to the tractor components while determining the amount of force generated by a towed implement. Fastening a load cell to the end of the drawbar was discounted, as such a system created a cantilevered load that affected the tractive efforts of the tractor (Zoerb et al., 1983). In addition, the load cell needed to be rigidly mounted to prevent excessive lateral movement during turning or stopping. The result was potential damage to the load cell and the tractor, as well as an unacceptable risk of personal injury to the operator. A design complication of using a load cell that would not pivot was that the load cell would prove less effective in measuring lateral loads as seen in contour or headland operations. Another method of integrating the load cell into the drawbar (proof-ring) was to permanently alter the drawbar which required a replacement drawbar to be installed after data collection was complete (Kheiralla and Yahya, 2001). Drawbar pin instrumentation was previously accomplished (Zoerb et al., 1983), but created an unacceptable level of physical noise in the data due to the often large tolerances between the drawbar hole, the pin, and the implement tongue. Another approach was to apply strain gages to the pin where the load on the drawbar transferred to the rear axle housing. This approach was suitable to reduce the noise due to narrower tolerances. A disadvantage of this method was that since the pin rotated freely, a directional strain error Applied Engineering in Agriculture Vol. 33(6): 781-789 2017 American Society of Agricultural and Biological Engineers ISSN 0883-8542 https://doi.org/10.13031/aea.12489 781

was generated. To avoid this error, minor design steps were required to ensure that the pin could not rotate during data collection. A pin of this design required additional development time and testing to ensure proper strain and alignment when compared to other alternatives. Previous studies have tried to determine the amount of power required to pull an implement via the drawbar (Wendte and Rozeboom, 1981; Grevis-James and Bloome, 1982; and Graham et al., 1990). These studies developed data acquisition systems (DAQs) that were capable of measuring the amount of force applied to the drawbar by an implement and ground speed of the machinery with wheel slip. Graham et al. (1990) used a hydraulic load cell attached to the end of the drawbar, while others used a modified drawbar instrumented with strain gages. All of these studies modified the tractor drawbar to measure the tractive efficiency with their main purpose being to determine draft loads and wheel slippage for tillage and planting operations. Calibration procedures, if listed, generally included a two point calibration linear scale. Other research related tire velocity, inflation pressure, and ballasting (Upadhyaya et al., 1988; Zoz and Grisso, 2003; Taghavifar and Mardani, 2013) to draft forces and tractive efficiency. This research presents a different approach for calibrating an instrumented drawbar and verifying the draft force of a towed implement in a laboratory using The Organisation for Economic Co-operation and Development (OECD) Code 2 test procedures (OECD Code 2, 2016). This research approach also minimized alterations to components supplied with the tractor by using a replacement drawbar for instrumentation, which could be mounted onto multiple tractors of similar size with limited modifications. OBJECTIVES The goal of this project was to develop a portable draft measurement and data acquisition system. This system measured the draft force applied by an implement on a tractor drawbar. Specific objectives were to: Calibrate the instrumented tractor drawbar, and Use OECD Code 2 tractor drawbar power test procedures and the Nebraska Tractor Test Laboratory load car to determine if there was any difference in draft measurements between the instrumented drawbar and the load car. MATERIALS AND METHODS An instrumentation system to measure and record draft force on the drawbar was developed. This system consisted of a drawbar instrumented with strain gages and DAQ hardware. The drawbar draft force measurement system was connected to a load cell integrated into the hitch of the Nebraska Tractor Test load car for evaluating the measurement accuracy. MEASURING DEVICES For an initial prototype design, an instrumented drawbar was deemed an appropriate component of the device under test. The ideal location to minimize vertical loading in the strain gage measurement was as close to the front drawbar support as possible (see fig. 1a). Material was milled from the surface of the drawbar to increase the sensitivity and provide a smooth surface to mount the strain gages (fig. 1a). A 90 strain rosette (Micro-Measurements EA-06-125TQ-350, Vishay Precision Group, Inc., Wendell, N.C.) was mounted on each side of the drawbar with one strain gage parallel with the length of the drawbar (fig. 1b) to measure the axial load and the perpendicular strain gage to compensate for temperature in the negligible loading direction. The wiring and the strain gages required protection from debris, so a crossdrilled hole provided a raceway between the rosettes for the sensor wires to be routed safely (fig. 1b). The strain gages on the rosettes were wired in a full-bridge configuration for temperature compensation (fig. 1c). The drawbar was interfaced using a National Instruments (NI) compact DAQ (NI 9174, National Instruments, Austin, Tex.) with a universal analog module (NI 9219, National Instruments, Austin, Tex.) which was capable of providing the excitation voltage of +2.5 VDC and ground required for the strain gage transducer (fig. 1d). DAQ Hardware and Software Program An NI 9174 cdaq is a portable 4-slot DAQ chassis for use with NI C series I/O modules. The chassis has the capability to handle multiplexed analog I/O signals, thermocouples, and digital I/O signals, in the same chassis. A NI 9219 universal analog module, capable of measuring analog voltages from strain gages bridges, thermocouples, load cells, and other analog sensors, was utilized. The full-bridge temperature compensated drawbar strain measurements were performed using the NI 9219 module for both calibration and testing purposes. The full-bridge mode of the NI 9219 uses the internal voltage excitation to return voltage reading proportional to the excitation level allowing the mv/v output of the load cell to be used in our calibration equation. Separate LabVIEW programs were utilized for the drawbar calibration and the drawbar testing on the NTTL test track. The LabVIEW graphical user interface (Front Panel) was the indication and control panel for the user. The Lab- VIEW program used for calibration was the current version of the NTTL load car hitch calibration program used with a NI compact reconfigurable I/O (crio) DAQ board. This program was configured to measure 3 load cells simultaneously at a sampling rate of 50 Hz, so it was necessary to reconfigure the Front Panel to measure 2 load cells (calibration fixture and drawbar). The user was required to setup channels in NI Measurement and Automation Explorer (NI MAX) to be called in the calibration program via a task. Push button control logic allowed elements to be hidden on the Front Panel of the NTTL load car hitch calibration program which were unused in this calibration application. Data were logged to a file for later use to determine the calibration equation. The LabVIEW program for NTTL track testing that was developed displayed drawbar pull in real-time, and test setup information (fig. 2) on the Front Panel. The Get Data push button control allowed the user to log the raw data for a specified test duration. To write the accumulated data to a file 782 APPLIED ENGINEERING IN AGRICULTURE

Figure 1. (a) Drawbar illustrating sensor location, (b) focused side view where strain gage rosette was placed on drawbar, (c) circuit diagram illustrating the bridge configuration as attached to DAQ module, (d) NI cdaq with NI 9219 module wired as a full-bridge design. after testing was completed, the Write Data push button control was used before stopping the program. A block diagram in LabVIEW included visually represented nodes analogous to statements, functions, etc. in textbased programming languages. The drawbar track testing program block diagram (Appendix I) was created utilizing similar nodes to the NTTL load car hitch calibration program. Tasks setup in NI MAX for calibration were used in the same capacity in the drawbar track testing program. Test Setup The drawbar was mounted on an AGCO Allis tractor (9695, AGCO Corporation, Duluth, Ga.) in the standard centered position (tractor in fig 3). The NI DAQ board used for drawbar draft force data acquisition was connected to a laptop situated inside the tractor cab. The LabVIEW program previously described was used to record the drawbar data. During the track testing, the NTTL load car (figs. 3a, 3b, 3c) was used to apply a constant force in the plane of the drawbar with minimum vertical and transverse loading. The hitch position was set to maintain a constant distance above the ground to avoid vertical loading, which was compensated by the full-bridge strain configuration. The load car used two Interface load cells (1232ALD-100K-B, Interface, Inc., Scottsdale, Ariz.) connected in series and attached to the hitch to measure the draft force under tension. Draft forces were measured in the first load cell while the second load cell was used to verify the load measurement (fig. 3c). The load cells on the NTTL load car were calibrated bi-annually using the independent calibration fixture in figure 4. The drawbar test was performed on the NTTL test track, utilizing the two 244 m (800 ft) straight lengths of concrete surface. The NTTL provided calibration fixture (fig. 4) consisted of an Interface Gold Standard (IGS) Calibration load cell (1632AJH-100K, Interface, Inc., Scottsdale, Ariz.) sent back to Interface, Inc. for calibration triennially to primary standards at NIST. The IGS was a 444.8 kn (100 klb f ) load cell with a static error of ± 0.017% full scale. A hydraulic cylinder utilizing a double-acting hand pump applied a tension load to the load cell while the other end of the load cell was attached to a steel plate connected to the drawbar. The calibration fixture frame used a spacing-block to keep the tractor frame equidistant from the calibration fixture frame so that the entire system was static. Calibration and Test Procedure The drawbar was attached to the calibration fixture (fig. 4), which uses a 444.8 kn (100 klb f ) IGS listed previously that conforms to NIST primary standards and has a 33(6): 781-789 783

Figure 2. LabVIEW Front Panel for drawbar testing on the NTTL test track. static error of ±0.017% full scale. One end of the IGS was attached to a hydraulic cylinder which developed the tension load, whereas the other end was attached to a steel plate connected to the drawbar (fig. 4). The calibration procedure began with anticipated physical loads of 4.45, 8.90, 13.3, 22.2, 44.5, 66.7, 89.0, 111, and 134 kn (1, 2, 3, 5, 10, 15, 20, 25, and 30 klb f ) as measured by the IGS. It was assumed that any load under 4.45 kn (1 klb f ) occurring during field use would be highly variable due to being either transport or a headland turn. Loads over 133 kn (30 klb f ) occurring during field use were assumed to be from heavy tillage equipment used by heavily ballasted >224 kw (>300 HP), track laying, or 4WD tractors using a higher category drawbar size. The bridge output voltage corresponding to the strain values from the drawbar were recorded for three replications near the anticipated IGS physical loads and converted to match the respective IGS physical load values (table 1). (a) Figure 3. (a) AGCO Allis 9695 pulling NTTL load car for track testing, (b) detail of AGCO Allis 9695 coupled to the test car, (c) test car hitch with serial load cells. Figure 4. Calibration stand using a hydraulic cylinder to apply load to the drawbar. 784 APPLIED ENGINEERING IN AGRICULTURE

Table 1. IGS force versus the Wheatstone bridge output for the instrumented drawbar. IGS Physical Force (kn) Drawbar Electrical Value (mv/v) 2.22 0.6979 4.45 0.7046 8.90 0.7185 13.34 0.7320 22.24 0.7559 44.48 0.8302 66.72 0.9038 88.96 0.9774 111.21 1.0493 133.45 1.1242 Using the summarized IGS physical force and drawbar electrical values in table 1, an iterative process was performed to ensure repeatable measurements within 0.67 kn (150 lbf). The resulting final drawbar force values and the electrical values from the iterative process are summarized in table 2. These resulting drawbar force and electrical values were used for the final calibration. The calibration plot can be seen in figure 5 and the calibration equation is presented in equation 1. ( ) Calibrated Force = 307. 99* output 211. 77 (1) where Calibrated Force = drawbar physical force (kn), output = wheatstone bridge output (mv/v). After the determination of the calibration equation of the drawbar, testing was accomplished using section 4.4.2.1 of the OECD Code 2 (OECD, 2016). According to this section of the OECD code, the speed settings required are: the Table 2. Final drawbar force calibration values. DUT Physical Value (kn) Drawbar Electrical Value (mv/v) 4.25 0.6979 4.94 0.7046 9.53 0.7185 13.41 0.7320 20.49 0.7559 43.48 0.8302 66.76 0.9038 89.82 0.9774 111.33 1.0493 134.35 1.1242 gear/speed setting giving a travel speed immediately faster than the maximum power developed down to the gear/speed setting giving a travel speed immediately slower than the maximum drawbar pull developed. These operating points are further limited by Nebraska Tractor Test Board Action No. 6 (NTTL, 1998) to include only typical field operating speeds. The Nebraska Tractor Test Board requires that the maximum drawbar power shall be determined: (a) in all gears which produce less than 15% slip and a nominal (unloaded) speed of less than 12.9 km h -1 (8 mph) at rated engine speed, (b) the gear below the slowest run from part (a) with the load adjusted to produce slip near 15%, and (c) a gear producing a nominal (unloaded) speed between 12.9 and 16.1 km h -1 (8 and 10 mph) at rated engine speed. The tractor was tested in seven gears corresponding to maximum power in each gear (gears 6 to 12) (NTTL, 1995) for typical field operating speeds. The first gear in each repetition was selected at each end of the range of gears used, but due to the load car s limited transmission ranges, the subsequent gears were selected in ascending or descending order to reduce the need to adjust the load car s transmission. For example, one of the replications gear sequence was 12, 11, 10, 9, 8, 7, and then 6. Each treatment consisted of four straight runs of 152.4 m (500 ft) on the concrete track in each of the seven gears. Measurements were obtained for three complete replicates of treatment combinations. Tests were carried out with the governor set to maximum engine speed. Wheel slip was measured to verify that the loading was such that none of the loads caused mean wheel slip to exceed 15% as required by OECD (section 4.4.1.7) (OECD, 2016). Other data recorded by the NTTL load car were engine speed, hydraulic temperature (to verify that steady state operating conditions were achieved before beginning data collection), draft force, and ground speed. The drawbar DAQ recorded the drawbar strain. The draft forces from the four runs were averaged to determine the means of each treatment (gear). Differences were determined for each treatment combination: the difference between the draft force as measured by the drawbar and the draft force measured by the load car. Student s t-tests, using an alpha level of 0.025 were used to determine which Drawbar Physical Force (kn) 140 120 100 80 60 40 20 y = 307.99x - 211.77 R² = 0.9999 0 0.6 0.7 0.8 0.9 1 1.1 1.2 Strain Electrical Value (mv/v) Figure 5. Final drawbar force calibration curve. 33(6): 781-789 785

(if any) of the differences in treatment means were significantly different from zero (drawbar different than load car measurement (H 0 = 0 kn)). A table value (t = 4.303) was obtained given a probability value of 0.05 corresponding to a 95% confidence interval and 2 degrees of freedom (three repetitions) for a two-tailed test. OECD Code 2 required the force measurements to be within ±1.0% (section 3.4.2, OECD Code 2, 2016). As field conditions vary more than laboratory conditions, draft measurements within ±2.0% were considered optimal, but an accuracy of ±2.5% was considered satisfactory for farm use (Grevis-James and Bloome, 1982). RESULTS AND DISCUSSION CALIBRATION VERIFICATION The table below (table 3) shows a comparison between the final calibrated drawbar force values and IGS force values. IGS values were the result of the final drawbar calibration curve replicated three times and then averaged to verify calibration repeatability within our calibration tolerances of 0.67 kn. The largest difference of the verification was at the 89 kn force with a difference of 0.53 kn (119 lbf, 0.60%). The calibration verification (fig. 6) shows the slope of the given linear regression by the instrumented drawbar was near a slope of 1.0 with relation to the force applied through Table 3. Final calibration verification. Drawbar Calibration Value (kn) IGS Force (kn) Average Force Difference (kn) Average Force Difference (%) 4.25 4.16 0.09 2.12 4.94 4.75 0.19 3.85 9.53 9.48 0.05 0.52 13.41 13.42-0.01-0.07 20.49 20.48 0.01 0.05 43.48 43.62-0.14-0.32 66.76 66.48 0.28 0.42 89.82 89.29 0.53 0.59 111.33 111.35-0.02-0.02 134.35 134.57-0.22-0.16 the IGS. Loads below 22.24 kn (5000 lb f ) had more variability due to the smaller measurement range between treatment loads. Additional calibration below this level was unnecessary due to loading and measurement time requirements and was within procedural tolerances. TRACK TEST The tractor equipped with the instrumented drawbar and the data acquisition system was tested on the concrete track using the NTTL load car. Data obtained during the test were averaged for each tractor gear. Student s T-tests were used to determine if there was a significant difference between the instrumented drawbar and the load car draft force measurements (H o = 0 kn). Draft force differences were not statistically significantly different from zero in any of the tested gears, leading to acceptance of the null hypothesis. In gear 12, the instrumented drawbar measured an average of 2.55% less force than measured by the load car which was out of the 2.5% accuracy range. Gears 6 through 11 draft force difference averages were within 2% draft force accuracy difference (table 4). Using the OECD tolerance of 1.0% for force measurements (section 3.4.2, OECD Code 2, 2016), gears 6 through 10 satisfied this tolerance. Figure 7 shows the correlation between the force measured by the load car and the force measured by the instrumented drawbar. The trend of this line (m = 1.0233) was close to the calibration curve with a strong coefficient of determination (R 2 = 0.9982) between the instrumented drawbar and the load car force measurements. The largest average draft force difference (0.99 kn, 2.88%) was in gear 12 whereas, the largest range of draft force values were in gears 6 and 7 (fig. 7). SUMMARY AND CONCLUSIONS Development of an agricultural tractor drawbar measurement and data acquisition system was accomplished. Static calibration was successful with the instrumented drawbar 160 140 120 y = 1.0004x - 0.0931 R² = 1.0000 IGS Force (kn) 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 Drawbar Calibration Value (kn) Figure 6. Calibration verification. 786 APPLIED ENGINEERING IN AGRICULTURE

Table 4. Average draft force results of the load car and DUT in corresponding gears. Gear Speed (km h -1 ) Average Load Car Force (kn) Average Drawbar Force (kn) Average Force Difference (kn) Average Force Difference (%) Force Difference Standard Deviation 6 4.95 81.31 81.98-0.6713-0.83% 0.91 7 6.10 77.00 76.79 0.2103 0.27% 0.10 8 6.88 72.82 72.30 0.5150 0.71% 0.69 9 7.84 62.71 62.17 0.5415 0.86% 0.55 10 9.17 54.42 53.98 0.4478 0.82% 0.44 11 10.89 45.71 45.01 0.7044 1.54% 0.53 12 12.80 38.67 37.68 0.9857 2.55% 0.34 90 80 70 y = 1.0233x - 1.8298 R² = 0.9982 DUT Force (kn) 60 50 40 30 Gear 6 20 10 0 Gear 12 0 10 20 30 40 50 60 70 80 90 Load Car Force (kn) Figure 7. Average draft force comparison between load car and drawbar for all replications of the test. yielding repeatable force values within 0.67 kn of the IGS force values after the final calibration was applied. Using OECD Code 2 and Test Board Action No. 6 as test procedures, the drawbar force was evaluated in select gears used for typical draft implement field operating speeds. Differences in draft forces between the instrumented drawbar and the load car (Ho = 0 kn) were not statistically significant based on the two-tailed Student s T-test using an alpha value of 0.025 leading to the acceptance of the null hypothesis. Draft force differences ranged from 0.21 kn (0.27%, gear 7) to 0.99 kn (2.55%, gear 12). Most gears provided an accuracy of less than 2.5% error, while gear 12 was the only gear to fall outside this margin. Gears 6 through 10 were the only gears to meet the OECD force measurement tolerance of 1.0%. However, as the OECD tolerances are possible in laboratory conditions, they are not necessarily representative of plausible field measurement tolerances leading to the higher acceptable tolerances of 2.5%. These results indicate draft force measurements for field use are achievable with the drawbar draft force measurement and data acquisition system. ACKNOWLEDGEMENTS The authors would like to thank Doug Triplett and Justin Geyer for the operation of the NTTL load car and the use of the calibration fixture. Thanks goes to all the NTTL student workers who operated the tractor and load car during testing. A special thank you to the NTTL for donating an instrumented drawbar to complete this research. REFERENCES Ellis, L. W. (1913). The Winnipeg tractor trials. Sci. Amer., 109(10), 201-204. Graham, W. D., Gaultney, L. D., & Cullum, R. F. (1990). Tractor instrumentation for tillage research. Appl. Eng. Agric., 6(1), 24-28. https://doi.org/10.13031/2013.26339 Grevis-James, I. W., & Bloome, P. D. (1982). A tractor power monitor. Trans. ASAE, 25(3), 595-597. https://doi.org/10.13031/2013.33579 Kheirella, A. F., & Yahya, A. (2001). A Tractor instrumentation and data acquisition system for power and energy demand mapping. Pertanika J. Sci. Technol, 9(2), 1-14. NTTL. (1995). Nebraska Tractor Test Laboratory Reports. Test 1700. Lincoln: Nebraska Tractor Test Board. Retrieved from http://digitalcommons.unl.edu/tractormuseumlit/2009 NTTL. (1998). Board Action No. 06. Lincoln, Neb: Nebraska Tractor Test Board. Retrieved from https://tractortestlab.unl.edu/documents/ttl_action6.pdf OECD. (2016). Code 2 OECD standard code for the official testing of agricultural and forestry tractor performance. Paris, France. Retrieved from http://www.oecd.org/tad/code/02%20- %20Code%202%20-%20Final(February%202016).pdf Taghavifar, H., & Mardani, A. (2013). Investigating the effect of velocity, inflation pressure, and vertical load on rolling resistance of a radial ply tire. J. Terramechanics, 50(2), 99-106. https://doi.org/10.1016/j.jterra.2013.01.005 Upadhyaya, S. K., Chancellor, W. J., & Wulfsohn, D. (1988). Sources of variability in traction data. J. Terramechanics, 25(4), 249-272. https://doi.org/10.1016/0022-4898(88)90040-7 33(6): 781-789 787

Wendte, K. W., & Rozeboom, H. (1981). Data acquisition for tillage energy evaluation. ASAE Paper No. 81-1045. St. Joseph, MI: ASAE. Zoerb, G. C., Musonda, N. G., & Kushwaha, R. L. (1983). A combined drawbar pin and force transducer. Can. Agric. Eng., 25(2), 157-161. Zoz, F. M., & Grisso, R. D. (2003). Traction and Tractor Performance, ASAE Distinguished Lecture #27. St. Joseph, MI: ASAE. APPENDIX I LABVIEW BLOCK DIAGRAM Figure 8. Block Diagram of LabVIEW program. Illustrates dialogue and file path names, and how the serial resource is initialized. 788 APPLIED ENGINEERING IN AGRICULTURE

Read analog strain channel Build array of analog strain readings Display analog data to user Write values to logging file Read and parse GPS serial data Figure 9. Block Diagram of LabVIEW program. Illustrates the reading and logging of the data. 33(6): 781-789 789