MODELS WGL20, WGL20H and WGL20F

Similar documents
HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

MODELS 4VC(X * ), 6VC(X * ), 4VE(X * ) AND 4RC(X * ) SUBMERSIBLE SOLIDS HANDLING PUMPS. *Used in Hazardous Locations Class I, Division 1, Groups C & D

SUBMERSIBLE SEWAGE PUMPS

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX

MODELS CX10 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

SUBMERSIBLE GRINDER PUMPS

HPGB750/1000/1500. Submersible Grinder Pumps. Pump Installation and Service Manual

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

MODELS HPGF/HPGFH, HPGH/HPGHH

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

S4HVX Shown. (Class I, Division 1, Groups C & D): FM

PUMP VAULT S.T.E.P. SYSTEM

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

SUBMERSIBLE BASIN MIXER

MODELS S3S(D)/S4S(D) and SB3S(D)/SB4S(D)

MODELS 125M/B, 150M/B and 200M/B

MODELS 125M/B, 150M/B and 200M/B

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

RAIL SYSTEMS WITH CHECK VALVE

Ion Technologies WC33 Submersible Sump Pump

(Class I, Division 1, Groups C & D): FM

SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps

SPC-PANEL Simplex, Single Phase Pump Control Panel

MODEL S4F SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

Pump Installation and Service Manual HRS Hydromatic Retractable System

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

AUTOMATIC SUBMERSIBLE UTILITY PUMP

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

4WHV, V4WHV Submersible Solids Handling Pumps

MYERS MODELS 4R AND 4RX

MODEL TL-PRO SYSTEM COMPLETE GRINDER PACKAGE OFFERING INSTALLATION AND SERVICE MANUAL. For use with HPG(X)200 and HPGR200 Hydromatic Grinder Pumps.

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

PRE-PLUMBED SEWAGE SYSTEM

MYERS MODELS 4V AND 4VX

INSTALLATION AND SERVICE INSTRUCTIONS KER KEEN PUMP - e/one Replacement

ESE Series Cast Iron Sewage Pumps

SUBMERSIBLE SUMP PUMPS

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 1HP CENTRIFUGAL SUBMERSIBLE EFFLUENT PUMPS

For use with Hydromatic grinder pumps: HPG200, HPGR200 and HPD200 (shown on cover).

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

(Class I, Division 1, Groups C & D): FM

471 US Hwy 250 East, Ashland, Ohio PH: FX:

SUBMERSIBLE SUMP PUMPS

StormPro BA Series Sump Pump

INSTALLATION & SERVICING MANUAL 2 HP Submersible Grinder Pumps. 200 / 230 Volt, 1- Phase, Internal Capacitor Kit, High Head G2-21SE Series

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

SUNC3000 / Item #40885

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Matala. VersiFlow Series. Instruction and Maintenance Manual

StormPro BCV400 Sewage Ejector Pump

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP

MYERS MODELS 4RC AND 4RCX

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

SHEF30 Submersible Sump/ Effluent Pump

MYERS MODELS 6VC & 6VCX

HYDROMATIC. G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM. Pump Installation and Service Manual

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

S4HVX Submersible Pump with Explosion-Proof Motor End (Class I, Division 1, Groups C & D): FM For use with product built with USEM motor.

MYERS MODELS 4VC & 4VCX

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

GeyserMax-Flow Series

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump

MYERS 4VCDP. 4" Solids Handling

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

GARDEN HOSE UTILITY PUMP

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

Ion Technologies ES45 Effluent Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

SP40 Submersible Sewage Ejector Pump

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

Your Premier Pump Choice!

SH30 High Head Effluent Pump

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

SUBMERSIBLE SWIMMING POOL DRAINER

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Transcription:

MODELS WGL20, WGL20H and WGL20F GRINDER PUMPS INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part # 23833A032 2017 Pentair plc 02/20/17

Thank you for purchasing your Myers pump. To help ensure years of trouble-free operation, please read the following manual carefully. SAFETY WARNINGS: Before Installation: This manual contains important information for the safe use of this product. Read this manual completely and follow the instructions carefully. Reasonable care and safe methods relating to the installation and operation of this product should be practiced. Check local codes and requirements before installation. DANGER: Risk of electrical shock or electrocution. May result in serious injury or death or fire hazard. Installer must disconnect all electrical sources prior to installation, handling or servicing. Only qualified personnel may install this system. NFPA 70/National Electric Code (NEC) or local codes must be followed. System must be properly grounded according to NEC. Do not lift pump by power cord. DANGER: Biohazard risk. Once wastewater source has been connected to system, biohazard risk exists. Installer(s) and/or service personnel must use proper personal protective equipment and follow handling procedures per OSHA 29 CFR 1910.1030 when handling equipment after wastewater source has been connected to system. DANGER: Risk of asphyxiation. Installer(s) and/ or service personnel must use proper personal protective equipment and follow OSHA 29 CFR 1910.146 or OSHA 29 CFR 1926. Pump may be installed in a location classified as a confined space. DANGER: Risk of fire or explosion. Do not smoke or use open flames in or around this system. This system is not intended for use in hazardous locations per NFPA 70 National Electric Code. Do not pump flammable liquids. DANGER: Cutting risk. Risk of serious cutting or amputation exists. Disconnect all power sources prior to servicing pump or grinding mechanism. Pump may start without warning. Grinding mechanism is extremely sharp. Use caution when handling grinder mechanism. Do not modify the cord strain relief. When wiring to a system control, connect the pump ground lead to the system ground. Do not run the pump dry. Dry running can overheat the pump (causing burns to anyone handling it) and will void the warranty. CALIFORNIA PROPOSITION 65 WARNING: This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. 2 The pump normally runs hot. To avoid burns, allow it to cool for 30 minutes after shutdown before handling it. Submersible grinder pumps are not approved for use in swimming pools, recreational water installations, decorative fountains or any installation where human contact with the pumped fluid is common. This specialized pump is designed to incorporate a grinding mechanism to remove wastewater particulate and pump the resulting slurry from a residential structure to a collection system. On three-phase pumps only, motor protection must be provided by the installer. All threephase pumps must be installed with magnetic starters having three-leg overload protection in accordance with the national electric code. For duplex installations, both pump motors must have separate overload protection. Pumps with seal leak detectors must be connected to the proper control circuitry. Examine all lifting devices, rope or chain for damage before and after each lift. Do not use any lifting devices that are not rated for and designed to lift the weights involved with these pumps. PUMPS: 1. Keep clear of suction and discharge openings. Do not insert fingers in pump with power connected. 2. Make sure lifting devices are securely fastened each time before lifting pump. 3. Do not lift pump by the power cord. 4. Do not exceed manufacturer s recommendation for maximum performance, as this could cause the motor to overheat. 5. Secure the pump in its operating position so it cannot tip over, fall or slide. 6. Do not pump without safety devices in place. IMPORTANT! Manufacturer is not responsible for losses, injury or death resulting from failure to observe these safety precautions, misuse or abuse of pumps or equipment. Control Panels: All Myers control panels used on these grinders are UL listed and CSA certified. Control panels mounted directly to the basin used outdoors are UL listed and CSA certified waterproof. Level Sensing Controls: Intrinsically safe type float controls are recommended for all applications. An intrinsically safe control panel relay will limit the current and voltage to the level controls. A Myers control panel can be supplied with this type circuitry.

The float level controls maintain the basin sewage water level by controlling pump turn-on and turnoff level. 1. The lower turn-off control should be set so that the pump stops at approximately the top of the pump. 2. The upper turn-on control should be set above the lower turn-off control. The exact height between the two controls is determined by the number of pump starts desired and the depth of the basin. A maximum of 10 starts per hour should not be exceeded. 3. The override control is set at a specified height above the upper turn-on control. 4. The alarm control is set about 6" to 12" above the override control. 5. No control should be set above the inlet invert. Air Venting: Air tends to trap in the pump volute when water rises in the sump or when the pump is lowered into water after service. To vent off this air, a small hole is drilled into the pump volute. Be sure this vent hole is clean after any service work on pump. Usage: The WGL20 grinder pumps are for pumping domestic sewage. These pumps are not to be used for pumping commercial or industrial sewage such as from motels, schools, apartments, factories, etc. Pump Models: The WGL20 pumps are equipped with 208 and 230 volt single phase voltages and 208, 230, 460 and 575 volt three-phase voltages; and with or without seal leak detector. WGL20F pumps are high flow pumps and WGL20H pumps are high head pumps. Caution: Pump is only to be disassembled at Myers factory or an authorized Myers service facility. Description of Pump: This pump is intended to grind and pump all normal sewage for home use. Pump is of heavy duty construction and submersible type for long life when pumping ground sewage. Motor is capacitor start, capacitor run for single phase. Capacitors and start relay are mounted in the electrical control box. All single-phase motors must have special electrical control box furnished by Myers. Installing single-phase motors with controls other than Myers voids warranty. Pump has two oil-filled chambers: 1) the motor and ball bearings and 2) the seal chamber for long life and best heat transfer. The lower seal above the pump impeller acts as a buffer for upper seal that holds oil in the motor chamber. If lower seal leaks for any reason, water enters the seal chamber. If motor has the seal leak detector, the electrode will contact the water and close the circuit to the red seal light in the control panel, indicating motor must be serviced before upper seal fails. Motor Overload Protection: The single phase motor is provided with an on-winding overload switch. If motor overloads or overheats for any reason, the switch opens, stopping motor. As soon as the motor cools to normal temperature, the switch closes and restarts the motor. Three-phase motors must be protected with an overload in the panel. Motor Power Cords: Pump models with the seal leak detector use a 5 conductor cord. The three power conductors are black, white and red. The orange conductor connects to the seal leak probe and green conductor connects to the ground screw inside the cord cap. Single-phase pumps use the black (common) and white (run) as main winding leads and the red for the start winding. Cord Seal: The lines from the motor chamber are sealed with a rubber sealing grommet that prevents oil from leaking into the cord cap compartment. If necessary to replace power cord, the sealing grommet must not be loosened. This wire seal is removed only for complete motor repair that must be done at an authorized Myers service facility. IMPORTANT! Ground wires must be connected in the control box to grounding bar, which is connected per NEC requirements. Motor is not safe unless properly grounded. Three Phase Control Box: Any suitable three phase control equipment can be used for simplex or duplex operation. These control boxes are also available from Myers. If other than Myers box is used, overload heaters must be selected in accordance with full load amp ratings. If any amp readings are higher than listed, it indicates voltage may be higher or lower than normal, or that pump grinder may be clogged with trash causing extra load on motor. Resistance of Winding: Every motor winding has a fixed resistance and winding must check close to the specification values. This winding resistance also shows if motor is connected for voltage being used. Use ohmmeter for this test and set on scale to read directly in ohms. 3

TROUBLE CHECK LIST Troubles listed below are generally not caused by the pump. Other trouble can occur from faulty control box operation. These will be listed with the control box instructions. CONDITION PROBABLE CAUSE Pump runs but does not pump liquid from basin 1. Pump impeller may be air locked; this occasionally occurs on a new installation. Start and stop pump several times to purge air. 2. Run additional water into basin so that pump will be submerged deeper to clear air. 3. If air does not clear, it may be necessary to lift pump out of sealing elbow and start motor to allow pump to pump for a few seconds. If discharge is piped in with union, slightly break union and start pump to clear air. Air vent hole is provided in pump case, so some water will flow from this hole when pump is operating. If vent hole gets clogged, clean out. 4. If pump has been installed for some time and does not pump, it may be clogged at grinder inlet. 5. Discharge gate valve may be closed. 6. Discharge check valve may be clogged or have a broken clapper. 7. Discharge head may be too high. Check elevation. Maximum pump head at zero flow is 70 feet. Red light comes on at control box. 1. This indicates some water has leaked past the lower seal and has entered the seal chamber and made contact with the electrode probe. Pump must be removed from basin immediately for replacement of lower seal. This preventive repair will save the motor. Overload trips and alarm buzzer or flashing red light comes on due to high water level in basin. 1. Push in red reset button to reset overload. If overload trips again after short run, pump has some damage and must be removed from basin for checking. 2. Trouble may be from clogged grinder causing motor to overload or could be from failed motor. 3. Trouble may be from faulty component in control box. Always check control box before removing pump. Yellow run light stays on continuously. 1. Indicates H-O-A switch be in the Hand position. 2. Level control switch may have failed causing pump to continue to operate when water is below lower float. 3. Grinder assembly may be partially clogged causing pump to operate at very reduced capacity. 4. Check valve may be clogged causing low pump flow. Gate valve may be in Off position. 5. Pump may be air locked. 4

TROUBLE CHECK LIST (Cont d) CONDITION PROBABLE CAUSE Circuit breaker trips. 1. Reset breaker by pushing clear down on handle, then back to On position. If breaker trips again in few seconds it indicates excessive load, probably caused by a short in the motor or control box. Check out instructions given with control box before pulling pump. 2. If this condition happens after an electrical storm, motor or control box may be damaged by lightning. 3. Resistance reading of the motor with lead wires disconnected from the control box can determine if trouble is in motor or control box. Pump is noisy and pump rate is low. 1. Grinder assembly may be partially clogged with some foreign objects causing noise and overload on the motor. 2. Grinder impeller may be rubbing on grinder ring due to bent shaft or misalignment. Grease and solids have accumulated around pump and will not pump out of basin. 1. Pump On switch may be set too high. 2. Run pump on Hand operation for several minutes with small amount of water running into basin to clean out solids and grease. This allows pump to break suction and surge which will break up the solids. 3. Trash may have accumulated around lower weight causing pump to turn off too soon. Clean trash from weight and suspension cable. 5

COMMON PARTS LIST 29 6 7 9 8 10 11 12 13 14 15 17 18 19 20 21 22 23 24 25 26 27 31 33 34 35 36 37 38 1 15 32 2 32 1 45 PUMP CAT. NO. (24) ROTOR W/SHAFT ROTOR ONLY HOUSING W/STATOR (23) STATOR ONLY WGL20-01 Series 24327C000 21572C200B 24325D035K 24326C100 WGL20-21Series 24327C000 21572C200B 24325D020K 24326C101 WGL20-03 Series 24327C001 21572C201B 24325D040K 24326C104 WGL20-23 Series 24327C001 21572C201B 24325D025K 24326C103 WGL20-43 Series 24327C001 21572C201B 24325D031K 24326C102 WGL20-53 Series 24327C001 21572C201B 24325D045K 24326C105 43 44 28 3 5 30 4 16 39 40 42 41 Item No. Eng. No. Description Qty. 1 28184B020 CAP, CORD ASSEMBLY 1 28184B022 CAP, CORD WITHOUT SEAL DETECTOR ASSEMBLY 1 2 05013A039 SCREW, SET, 1/4 x 3/8 LG. 2 3 05434A025 SCREW, MACHINE 1 4 19100A012 SCREW, CAP, 5/16" x 1-1/4" LG. 4 5 21581C310 IMPELLER, PUMP, 5-1/2" O.D. 1 22640C014 IMPELLER, HIGH HEAD DUCTILE IRON (WGL20H) 1 21581C314 IMPELLER, HIGH FLOW (WGL20F) 1 6 05434A043 SCREW, MACH., #10 x 3/8" LG. 2 7 06107A015 LOCK WASHER 1 8 24321A000 PLATE, UPPER 1 9 24322A000 SCREW, CAP, #10 SPECIAL 1 10 24323A000 GROMMET 1 11 24324A000 PLATE, LOWER 1 12 05014A169 GASKET, TETRASEAL, 3-7/8" I.D. x 1/8" 1 13 22500A118 WIRE, RED 1 14 22500A119 WIRE, WHITE 1 15 22500A120 WIRE, BLACK 1 16 21582B000K IMPELLER, GRINDING 1 17 05022A092 PLUG, 1/4 PIPE 2 18 22500A117 WIRE, YELLOW 1 19 19331A005 WASHER, SPRING 2 20 08565A013K BEARING, UPPER 1 21 11816A006 RING, RETAINING 1 22 24325D002 HOUSING, MOTOR 1 23 See Chart STATOR 1 24 See Chart ROTOR W/SHAFT 1 24331C000 SHAFT ONLY 1 See Chart HOUSING W/STATOR 1 25 08565A018K BEARING, LOWER 1 26 05014A171 GASKET, 5-1/2" I.D. x 1/8" 2 27 24328D000 HOUSING, UPPER SEAL 1 28 12074A017 RING TERMINAL 1 29 12672A880 DOUBLE LEVER NUT 6 8 30 25343A100 ELECTRODE 1 31 06106A008 SCREW, SOCKET HD., 5/16" x 1" 4 32 07597A018 SCREW, FLAT HD., 1/4" x 3/4" 1 33 24329C000 HOUSING, LOWER SEAL 1 34 22581A001 GASKET 1 35 21576A011 SEAL, 7/8" SHAFT, UPPER 1 36 12558A006 RING, RETAINING 1 37 21576A010K SEAL, 7/8" LOWER 1 38 21580D102P CASE, VOLUTE 1 39 21583A000 RETAINER, IMPELLER 1 40 19100A029 SCREW, CAP, 5/16" x 1" LG. 4 41 19099A012 SCREW, CAP, 1/4" x 1" LG. 3 42 21584B002 FLANGE W/SHREDDING RING (WGL20H) 1 21584B000K FLANGE W/SHREDDING RING (WGL20) 1 21584B004 FLANGE W/SHREDDING RING (WGL20F) 1 43 20-01-497-4400 CABLE, 4 COND. (LENGTH AS SPECIFIED, LESS DETECTOR) as spec. 20-01-497-4750 CABLE, 5 COND. (LENGTH AS SPECIFIED, LESS DETECTOR) as spec. 44 18696A012 CONNECTOR, 4 COND. CABLE 1 18696A001 CONNECTOR, 5 COND. CABLE 1 45 24320C000 CAP, CORD (CASTING ONLY) 1 6

MOTOR WIRING DIAGRAM 7

STANDARD LIMITED WARRANTY Pentair Myers warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Pentair Myers or 18 months from the manufacturing date, whichever occurs first provided that such products are used in compliance with the requirements of the Pentair Myers catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids. during the warranty period and subject to the conditions set forth, Pentair Myers, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Myers reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units. Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of startup through the Pentair Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m. Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower seal and labor thereof for all dual seal pumps. under no circumstance will Pentair Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Myers service facility. this limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Myers or an authorized Pentair Myers service provider; (h) to any unit that has been repaired using non factory specified/oem parts. Warranty Exclusions: PEntAiR MYERS MAKES no EXPRESS or implied WARRAntiES that EXtEnd beyond the description on the FACE hereof. PEntAiR MYERS SPECiFiCALLY disclaims the implied WARRAntiES of MERChAntAbiLitY And FitnESS FoR AnY PARtiCuLAR PuRPoSE. Liability Limitation: in no EVEnt ShALL PEntAiR MYERS be LiAbLE or RESPonSibLE FoR ConSEQuEntiAL, incidental or SPECiAL damages RESuLtinG FRoM or RELAtEd in AnY MAnnER to AnY PEntAiR MYERS PRoduCt or PARtS thereof. PERSonAL injury And/oR PRoPERtY damage MAY RESuLt FRoM improper installation. PEntAiR MYERS disclaims ALL LiAbiLitY, including LiAbiLitY under this WARRAntY, FoR improper installation. PEntAiR MYERS RECoMMEndS installation by PRoFESSionALS. Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. no warranties or representations at any time made by any representatives of Pentair Myers shall vary or expand the provision hereof. 1101 MYERS PARKWAY 490 PinEbuSh RoAd, unit #4 AShLAnd, ohio, usa 44805 CAMbRidGE, ontario, CAnAdA n1t 0A5 419-289-1144 800-363-PuMP WWW.FEMYERS.CoM Warranty Rev. 12/13