Dr. Mach Lamps and Engineering

Similar documents
STAND FOOT - STAND TUBE

ACROBAT SWING STAND MODEL

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital

Dr. Mach Lamps and Engineering

STAND MODEL FOR MACH M2

ACROBAT SWING STAND MODEL

CEILING ATTACHMENT FOR MACH M2

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering

Dr. Mach Lamps and Engineering

CEILING ATTACHMENT ACROBAT SWING

OPERATING INSTRUCTIONS

Isolation Transformer for Medical Applications

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

Installation manual wall-mounted distributor

HEINE NT4 MED V

Energy-Saving Under-Cabinet Light. Assembly and safety advice Z30802A-BS Z30802B-BS

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

OPERATING INSTRUCTIONS

Installation manual portable distributors

Re.Formance Line INSTRUCTION MANUAL 1703

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

User guide Operator chair Carl Carl Foot and Carl Heel

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

User Manual SONESTA S2 & S3

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

OPERATING INSTRUCTIONS

User manual Patient chair Malin

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

User Instructions Shower and Commode Wheel Chairs

Linear Luminaire with LED

Self-propelling Shower and Commode Wheel chairs

Mobile Shower Commode Chair

ISO FM Made in the U.S.A

Exchange of rollers from the XTS-Mover

AM-134, AM-140, AM-234, AM-240, AM-334, AM-340, AM-368

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Mobile Shower Commode Chair

PET UNIT DOSE CABINET

Linear Luminaire for Fluorescent Lamps

KD1E Range Potential Indicators

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

D-LUX DENTAL LIGHT INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-711M Model AL-712M Model AL-715M

Triple Output Power Supply

Crozz two 2G 320/430/650

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

Operating Instructions. International English. CCS Dust Extractor

K&L MC200 ELITE WHEEL BALANCER Product Manual - MC Wheel Balancing

S-Drive Performance Trainer

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

ADJUSTED TO SITUATION AND SPACE

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

FACTORY AUTOMATION MANUAL ENI11HD

AIM LED LIGHT (ceiling mount)


2 TONNE GARAGE JACK Model No: CTJ2QLP PART NO:

Operating Instructions Flexdip CYA112

Condor Manual. Corporation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

User Manual Rittal PMC UPS 6kVA

Gavita HortiStar 1000 DE EU/US

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Checking the usage. Slow opening/slow closing damping unit:

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Functional Description and Specifications. Intended Use. Packing List

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

Astor 20 Colony Counter User s Manual

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

Dignity Hydraulic Height Adjustable Reclining Shower Chair

2¼ TONNE TROLLEY JACK

ASSEMBLY MANUAL 9GU - COMMERCIAL UPRIGHT BIKE

28W WORK LAMP Model: CTL28 Part No:

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Turner PRO. User manual. BM61099 Rev B

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Hydraulic Rotary Hammer Drill

Lifting device for standard removable versions

User manual. Model Mini, Small, Medium and Large

Operating instructions SEARCHLIGHT SW300/ SW300A

1 TONNE FOLDING CRANE. 1 TONNE FOLDING CRANE MODEL No CFC100 PART No OPERATING & MAINTENANCE INSTRUCTIONS 1202

COBRA Indoor base with gas pressure spring and 45 tilt function user manual

PT Line & Orthopedic Hi-Lo Casting Table

HVX Vacuum circuit-breaker kv ( 2500 A, 40 ka)

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

SM6. instructions for use. IMB cubicle without earthing switch. MV distribution factory built assemblies at your service. Anglais

Transcription:

Mounting instructions MACH LED 3MC/SC STAND MODEL Mach LED 3MC stand lamp Order No. 370 530 1200 Mach LED 3SC stand lamp Order No. 360 530 1200 Accessories Surcharge for integrated laser pointer Order No. 9005 0100 25 Clamp rail Order No. 74961002 Table Order No. 74961004 Plug strip Order No. 74961005 GmbH u. Co. KG, Floßmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: www.dr-mach.com, E-Mail: info@dr-mach.de 59520003 Edition 01 14.12.2009 / Bak Page 1/13

List of contents 1. Mounting the stand tube to the stand foot...page 3 2. Mounting the central spring arm to the stand tube...page 5 3. Mounting the lamp to the central spring arm...page 6 4. Cleaning...page 7 5. Adjusting the spring arm...page 7 6. Electrical connection...page 9 7. Changing the fuses...page 10 8. Technical data...page 11 9. CE-mark...page 12 10. Disposal...page 12 11. Dimensions...page 13 12. Spare parts...page 14 59520003 Edition 01 14.12.2009 / Bak Page 2/13

Extent of supply: Allan key/ DIN 911-5, -3 and screws Central spring arm Lamp Mach LED 3MC or Mach LED 3SC Stand tube pre-mounted with transformer housing and rollers 1. Mounting the stand tube to the stand foot L L Loosen two screws 1 before mounting each foot. Then insert the four feet and fix them with the screws (do not tighten!) K For mounting the stand foot proceed as described in the enclosed figures and drawings. K L = long feet S = short feet 1 Attention! After fixing the feet, tighten all sixteen screws uniformly! Push together both tubes as shown in the photography. Connect the two cables (see plug-in-connection S in the left photography). S 59520003 Edition 01 14.12.2009 / Bak Page 3/13

Slightly tighten the two parts of the stand tube at the intersecting point by using the two braces. braces intersecting point A4 A3 A2 Preview of the covers and parts to be mounted Each mounting is described separately below. Remark: The number of covers can be different depending on the design of the stand. A1 Optionally the stand can be ordered with a table. Fix the table above the plugs using the four screws included in the scope of supply. Then attach the open cover A1 (included in the scope of supply) above the plugs. Slip the enclosed handle over the stand tube and fix it with the screws (2 pcs.) and lock washer (1 piece) included in the scope of supply (see photography). 59520003 Edition 01 14.12.2009 / Bak Page 4/13

Put the lower protective cover A2 on the stand tube and fix it. If necessary, loosen the screws at the two braces in order to arrange the handle in horizontal position. Attention: Then tighten all six screws. A2 Now put the upper protective cover A3 on the stand tube and fix it. Mount the open cover A4 included in the scope of supply. The stand can be ordered optionally with a clamp rail. This clamp rail is fixed with the enclosed two screws above cover A3. A3 2. Mounting the central spring arm to the stand tube View of the spring arm from below 1 For mounting the central spring arm to the stand tube proceed as follows: Insert journal 1 of the spring arm into stand head 2. The electrical connection is ensured by a cable with plug inside the stand head. Make sure, that stop pin 3 at the spring arm lies in countersinking 4 at the stand head as shown in the figure. 3 4 2 59520003 Edition 01 14.12.2009 / Bak Page 5/13

3. Mounting the lamp to the central spring arm Preparatory work Attention! Power off the on-site power supply and protect it from being switched on again. 1 2 Attention! Danger of injury: The spring arm, when it is pressed down, can jump up suddenly and cause injury. During the installation of the end device, do not allow anyone to be within the swiveling range of the spring arm. 2 4 3 5 Turn mounting hole 5 in the sleeve 1 downwards. Remove the brake screw 4 at the bottom side of sleeve 1. Turn sleeve 1 by 90 degrees and remove the end device securing screw 2. Turn sleeve 1 by 180 degrees and remove the second end device securing screw 2. Remove the protective cap 3. Mounting Note: Maximum lamp / device weight: The lamps / devices must not exceed the weight of the mounted spring system. For details about the spring system please refer to the type plate of your ACROBAT 2000. Spring version: 10,0 15,0 kg Insert the end device 6 into the mounting of the spring arm. 1 2 Attention! Danger of injury: Hold the end device to avoid its falling down. 2 4 5 6 10 Tighten the first end device securing screw 2. Turn sleeve 1 by 180 degrees and tighten the second end device securing screw 2. Turn sleeve 1 by 90 degrees and tighten the brake screw 4. Adjust the brake force so the lamp / the end device always keeps its set position. Check the firm seating of the end device. Adjust the spring force as described in chapter 8.2.3. Adjust the verrtical limit as described in chapter 8.3.3. 59520003 Edition 01 14.12.2009 / Bak Page 6/13

DANGER OF INJURY! During the transport of the stand with lamp tip the stand for maximum 5 to avoid danger of injury! Each delivered stand has a sticker with this warning. In case the stand is moved when positioning the OT-lamp, please make sure, that all rollers are moveable (brakes are loosened, no cables in the movement range of the stand)! 4. Cleaning The stand has a high-quality surface, which can be cleaned with conventional cleaning agents. Alc. 20 % Pay attention to the following during cleaning: - Never wipe over the stand with a dry cloth. - Only use disinfectant with less than 20% alcohol. 5. Adjusting the spring arm Height adjustment At delivery the spring arm is set in the horizontal position. The vertical movement of the spring arm can be enlarged up to 45 degrees upwards. Attention! Power off the on-site power supply and protect it from being switched on again. X 3 4 5 Power off the pendant system / pull out the power plug and protect the pendant system from being switched on again. Remove the two Philips screws 4 and take off the covers 3. At the position marked X you can see the adjusting nut 5. Adjust the nut 5 with the enclosed metal pin. Mount the two covers 3 and fix them with the two Philips screws 4. Check the firm seating of the covers 3. 59520003 Edition 01 14.12.2009 / Bak Page 7/13

Hole 6 Adjusting the spring force To adjust the spring force make sure that the spring arm with the lamp / device can come to rest in any desired position. Insert the Allan key width 5 in the hole 6. If the spring arm drops, the spring force is too low: - Rotate the adjustment screw to the left (counter clockwise) in the + direction. If the spring arm rises, the spring force is too high: - Rotate the adjustment screw to the right (clockwise) in the - direction. + 3 - If the spring arm with the lamp / device cannot come to rest in any desired position after the spring force has been adjusted, the springs must be replaced by a service technician. SW5 59520003 Edition 01 14.12.2009 / Bak Page 8/13

6. Electrical connection Caution: Always draw plug from mains before doing any work at the lamp, stand or power supply. The electrical connection between stand tube and spring arm is ensured by connectors and the connection between lamp and spring arm is ensured by sliding contacts. Connect the mains supply. Check the function of the lamp. 15 16 Threre can be connected three additional devices to the plug strip of the stand. Attention: We recommend to consult an electrician before connecting additional devices in order to avoid electrical overload of the stand. Leakage current When several devices are connected to one main plug, the sum of the leakage currents may exceed the maximum limit. 16! DANGER Additional devices In case the device is used in the patient area together with other devices, these devices must be supplied by a isolation transformer, or connected to the earth protection system, if the additional devices do not comply with standards IEC 601-1 and IEC 601-1-1. For safety reasons the safety plugs are covered with the cover 15. For connecting additional devices proceed as follows: Turn off the lamp. Loosen the four screws 16 with an Allen key width 5 and remove the cover 15. Connect the additional devices. Fix the cover 15 with the four screws 16. 59520003 Edition 01 14.12.2009 / Bak Page 9/13

7. Technical data Each mounted lamp, that leaves our factory, has the model type applied on the lamp housing and all technical data mentioned on the nameplate. nameplate Gleichstrom Direct current Pr Primärseitig 230V Primary side Sek Sekundärseitig 28V DC Secondary side Symbols and their meaning Symbol IEC-publication Description IEC 417-5031 Direct current! IEC 417-5019 IEC 348 IEC 417-5008 IEC 417-5007 Protective conductor Attention, observe enclosed documents Off (Supply, disconnected from mains) On (Supply, connected with mains) 59520003 Edition 01 14.12.2009 / Bak Page 10/13

Environmental conditions Function Min. Max. Temperature -10 C +40 C Relative atmospheric humidity 30 % 75 % Air pressure 700 hpa 1060 hpa Transport / storage Min. Max. Temperature -10 C +40 C Relative atmospheric humidity 20 % 90 % Air pressure 700 hpa 1060 hpa 8. CE-mark The product stand ITD complies with the standards 93/42/EEC for medical products of the European Community s Council. 9. Disposal The OT-lamp doesn t contain any danger goods. The components of the OT-lamp should be properly disposed at the end of its shelf-life. Make sure, that the materials are carefully separated. The electrical conducting boards should be submitted to an appropriate recycling proceeding. The rest of the components should be disposed according to the contained materials. 59520003 Edition 01 14.12.2009 / Bak Page 11/13

10. Dimensions Light Mach LED 3MC/SC Swivelling range of the spring arm upwards downwards total 520mm 630mm 1150mm 59520003 Edition 01 14.12.2009 / Bak Page 12/13

12. Spare parts 5 4 2 6 3 1 Item Qty. Name EDVNO Remark 1 1 Stand for OT-light 74961001 2 1 Handle 74961003 3 1 Transformer housing with power supply 250W 9300009905 4 1 Central spring arm AC2000 12,0 18,0kg 74803005 5 1 Sliding contact plug 67330002 Not shown 6 1 Video socket (for lights with integrated camera) 46006002 Option 7 1 Clamp rail 74961002 Option, not shown 8 1 Table 74961004 Option, not shown 9 1 Plug strip 74961005 Option, not shown 10 1 Device switch 67340006 Option, not shown 59520003 Edition 01 14.12.2009 / Bak Page 13/13