Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Similar documents
Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Parts and characteristics

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Ceiling swirl diffusers with perforated face plate

Type VSD35. Nominal length up to 1500 mm: one spigot

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

CONSTANTFLOW Volume Flow Controllers

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

CAV controllers Type RN

Slot diffusers for ceiling installation

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

VARYCONTROL VAV Dual Duct Terminal Boxes

Ceiling swirl diffusers

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Multileaf damper with actuator

VAV Terminal Units SDS

TYPE EK-EU SMOKE CONTROL DAMPER

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

For installation into ductwork

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Technical documentation

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

[Y] Acoustic Splitters with spigot ends/aerodynamically shapped for energy saving (Pressure drop reduction 25% to 30%)

Ceiling swirl diffusers

VAV controller. TROX Auranor Norge AS. Telephone Fax

Ventilation grilles for installation into walls, sills or rectangular

Ceiling swirl diffusers with perforated face plate

TROX Prisliste Regulatorer K5-00

VAV TERMINAL BOXES TYPE: BA BT

Type Pneumatic actuators

Pressure relief dampers

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Waterside Fancoil Units

Waterside Fancoil Units

Ventilation grilles for installation into walls, sills or rectangular

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Volume Flow Limiters Type VFL

Pressure control damper ERPA

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Mechanical mixing box MBM

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

Ceiling swirl diffusers

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

Type Pneumatic actuators

series Silencers

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy. Type Easy

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Technical Brochure. LTG Air Distribution. Variable flow rate controllers VRFactive. Rectangular, with LTG map control.

TBV - Terminal Unit. Halton TBV. Terminal Unit

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

Transcription:

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers for the reduction of air-regenerated noise of air terminal units Type TVJ, or EN Absorption material is non-combustible mineral wool with RAL quality mark, biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EG Mineral wool faced with glass fibre fabric as protection against erosion due to airflow velocities up to 0 m/s Insertion loss measured according to ISO 735 Casing air leakage to EN 1577, class A

APPLICATION Application Secondary silencer Type TX to reduce the air-regenerated noise of air terminal units For air terminal units TVJ and, and for mechanical self-powered controllers EN Nominal sizes 43 nominal sizes from 00 100 to 1000 1000 DESCRIPTION Parts and characteristics Casing Sound attenuator splitters without resonating panels Construction features Absorption sound attenuator without resonating panels Rectangular casing Connection on the room end suitable for 30 mm air duct profiles Splitters with aerodynamically profiled frames Maximum splitter thickness 100 mm Splitter arrangement and number depends on the nominal size 50 % free area for all nominal sizes Materials and surfaces Casing and splitter frames made of galvanised sheet steel Absorption material is mineral wool Mineral wool To EN 13501, fire rating class A1, non-combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905

(Technical Rules for Hazardous Substances) and EU directive 97/69/EG Faced with glass fibre fabric as protection against erosion through airflow velocities of up to 0 m/s Inert to fungal and bacterial growth Standards and guidelines Casing air leakage to EN 1577, class A Maintenance Maintenance-free as construction and materials are not subject to wear TECHNICAL INFORMATION Specification text, Order code, Produktbeziehungen

SPECIFICATION TEXT Rectangular secondary silencers for VAV terminal units to reduce the air-regenerated noise, available in 43 nominal sizes Insertion loss at least 9 db at 50 Hz Splitters with aerodynamically profiled frames. Connecting flanges on both ends, suitable for 30 mm duct connection Casing air leakage to EN 1577, class A. Complies with VDI 083, clean room class 3, and US standard 09E, class 100. Materials and surfaces Casing and splitter frames made of galvanised sheet steel Absorption material is mineral wool Mineral wool To EN 13501, fire rating class A1, non-combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EG Faced with glass fibre fabric as protection against erosion through airflow velocities of up to 0 m/s Inert to fungal and bacterial growth

ORDER CODE Order example: TX/600 400 Nominal size (B H) 600 400 mm Type Nominal size [mm] TX Secondary B H silencer Dimensions and weight, Product details Attachments: VARYCONTROL control components

Controlled variable Interface V min -/ V max - adjustment Differential pressure transducer Actuator Manufacturer Easy controller Dynamic Easy V Integral Integral 1 Compact controller Dynamic BC0 V MP bus Integral Integral BF0 V MP bus Integral Integral BL0 V LonWorks Integral Integral BM0 V Modbus Integral Integral BM0- J6 V Modbus and plug-in connecting cable Integral Integral XG0 V Integral Integral 3 XB0 V Integral Integral 3 LN0 V Integral Integral 5 LK0 V KNX 5 LY0 V Integral Integral 5 Compact controller Static SA0 V Integral Integral 4 SC0 Δp Integral Fast-running actuator, integral 4 Universal controller Dynamic B11 V Integral

B13 V Integral Actuator B7 V Integral Actuator B1B V Integral Spring return actuator XC3 V Integral Spring return actuator 3 Universal controller Static BP1 V MP bus Separate part BP3 V MP bus Separate part Actuator BPB V MP bus Separate part Spring return actuator BPG V MP bus Separate part Fast-running actuator BB1 V Separate part BB3 V Separate part Actuator BBB V Separate part Spring return actuator XD1 V Integral Actuator 3 XD3 V Integral Spring return actuator 3 BR1 Δp MP bus 100 Pa BR3 Δp MP bus 100 Pa Actuator BRB Δp MP bus 100 Pa Spring return actuator BRG Δp MP bus 100 Pa Fast-running actuator BS1 Δp MP bus 600 Pa

BS3 Δp MP bus 600 Pa Actuator BSB Δp MP bus 600 Pa Spring return actuator BSG Δp MP bus 600 Pa Fast-running actuator BG1 Δp 100 Pa BG3 Δp 100 Pa Actuator BGB Δp 100 Pa Spring return actuator BH1 Δp 600 Pa BH3 Δp 600 Pa Actuator BHB Δp 600 Pa Spring return actuator XE1 Δp Integral, 100 Pa Actuator 3 XE3 Δp Integral, 100 Pa Spring return actuator 3 XF1 Δp Integral, 600 Pa Actuator 3 XF3 XF3 XF3 XF3

XF3 XF3 1 TROX, TROX/Belimo, 3 TROX/Gruner, 4 Sauter, 5 Siemens order code detail, V volume flow rate, Δp differential pressure DIMENSIONS AND WEIGHT Nominal size CA-050 CA-100 ØD 3 ØD 3 mm mm ØD mm 100 199 99 99 15 4 34 14 160 59 359 159 00 99 399 199 50 349 449 49 315 414 514 314 400 499 599 399 450 648 448 500 698 498 560 758 558 630 88 68 710 908 708 800 998 798 Nominal size B mm H mm B 1 B H 1 H mm mm mm mm m kg 00 100 00 100 35 60 135 160 10

300 100 300 100 335 360 135 160 1 400 100 400 100 435 460 135 160 15 500 100 500 100 535 560 135 160 17 600 100 600 100 635 660 135 160 0 300 150 300 150 335 360 185 10 15 00 00 00 00 35 60 35 60 16 300 00 300 00 335 360 35 60 0 400 00 400 00 435 460 35 60 5 500 00 500 00 535 560 35 60 9 600 00 600 00 635 660 35 60 34 700 00 700 00 735 760 35 60 39 800 00 800 00 835 860 35 60 44 400 50 400 50 435 460 85 310 7 500 50 500 50 535 560 85 310 30 600 50 600 50 635 660 85 310 36 300 300 300 300 335 360 335 360 4 400 300 400 300 435 460 335 360 9 500 300 500 300 535 560 335 360 34 600 300 600 300 635 660 335 360 40 700 300 700 300 735 760 335 360 45 800 300 800 300 835 860 335 360 50 900 300 900 300 935 960 335 360 55 1000 300 1000 300 1035 1060 335 360 60 400 400 400 400 435 460 435 460 34 500 400 500 400 535 560 435 460 39 600 400 600 400 635 660 435 460 45 700 400 700 400 735 760 435 460 50 800 400 800 400 835 860 435 460 56 900 400 900 400 935 960 435 460 61 1000 400 1000 400 1035 1060 435 460 67 500 500 500 500 535 560 535 560 45 600 500 600 500 635 660 535 560 50 Home Contact Imprint Delivery and payment terms Privacy Disclaimer 018-04-30 TROX Austria GmbH

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX 700 500 700 500 735 760 535 560 56 800 500 800 500 835 860 535 560 6 900 500 900 500 935 960 535 560 68 1000 500 1000 500 1035 1060 535 560 73 600 600 600 600 635 660 635 660 55 800 600 800 600 835 860 635 660 67 1000 600 1000 600 1035 1060 635 660 80 800 800 800 800 835 860 835 860 79 1000 1000 1000 1000 1035 1060 1035 1060 107 1000 800 1000 800 1035 1060 835 860 93 TX 1 End facing the terminal unit End facing the room 3 Splitter section 4 Non-active section Home Contact Imprint Delivery and payment terms Privacy Disclaimer 018-04-30 TROX Austria GmbH

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX PRODUCT DETAILS Detail of flange 1 Flange Compressible seal, to be provided by others Installation details, Basic information and nomenclature INSTALLATION DETAILS Installation and commissioning Air duct profiles fit air terminal units TVJ and, and mechanical self-powered controllers EN Connect the non-active section of the secondary silencer to the VAV terminal unit TROX Austria GmbH Online-Services Service-Hotlines TROX Academy Your contact partner Online fault report Sales Austria and technical consulting +43 1 50 43 0 Contact Lichtblaustraße 15 10 Wien, Austria Telefon +43 1 50 43-0 Fax +43 1 50 43-34 E-Mail: trox@trox.at Home Contact Imprint Delivery and payment terms Privacy Disclaimer 018-04-30 TROX Austria GmbH