APPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM

Similar documents
SECTION WELDING FUME EXHAUST SYSTEM

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

Fume extractor is warranted for two years, parts and labor.

FUME DOESN T STAND A CHANCE

2520- EC Motor Speed Controller

LINCOLN ENVIRONMENTAL SYSTEMS

FilterMax F. Modular dust collector with integrated pre-separator. Models

FilterMax DF. Modular dust multi purpose collector. Models

FilterMax DF. Modular dust multi purpose collector. Models

Tubular Centrifugal Fans

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

RECORD SUBMITTAL COVER SHEET

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Square Inline Fans with Multi-Directional Discharge

SECTION AXIAL HVAC FANS

CONSTRUCTION FEATURES AND OPTIONS

Downflo workstation DuSt ColleCtorS


MODULAR BAGHOUSE DUST COLLECTORS POWERED BY

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

CAST ALUMINUM PRESSURE BLOWERS

YCCS Zone/Bypass Damper Assembly

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

SECTION HVAC AIR CLEANING DEVICES

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution

YCCS Zone/Bypass Damper Assembly

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

CH5000 Heat Recovery Ventilator

Centrifugal Filtered Supply Roof Blowers

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

FilterMax F. Modular dust collector with integrated pre-separator

CCS Zone/Bypass Damper Assembly

FilterMax F. Modular dust collector with integrated pre-separator

downflo workstation dust collectors

Inline and Roof Mounted Fans

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Laboratory Exhaust Systems

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

Rigid-Air Spun Glass or Synthetic Media Rigid Filter PB

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB

Climate Control Products

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

TURBO PRESSURE BLOWERS

WELD STRONG BREATHE FREE

Fixed Pitch Vane Axial Fan

Climas y Proyectos Leyco, S.A. de C.V.

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TSS Single-Duct VAV Terminals

SPECIFICATION FOR FILTERS, AIR (HVAC) (This specification is released for procurement purposes until revised or rescinded.)

SECTION DUST COLLECTOR

FAN POWERED TERMINAL UNITS

A. NU2035 HRV Specifications NU2035

Tube Axial Inline Fans

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

XeteX, Inc. All Rights Reserved.

PANEL & CARTRIDGE FILTERS

Technical Specification

FlowAir CATALOG.

Filtered Kitchen Supply Packaged Ventilator

Roof Upblast and Sidewall Exhaust

DUST COLLECTORS. Stronger. Better. CLEANER.

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

MODEL FA1 Mini Air Filtration System. Operations Manual

Factory Option Codes L M E S P R D V F F H E

Downflo. Oval Dust Collectors POWERED BY

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

PROPOSAL. Fume-A-Vent 4 Drop Source Capture Diesel Fume Extraction System for Firehouse/EMS

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

Improving your workspace

SF-1000 workbench - welding table. User s Manual.

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

Complete HVAC Capability

Introduction. Features. Intelligent Technologies Motor Control Center Structures

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

quatroair.com AIR TECHNOLOGIES INC.

FOR USE IN SOLUTION AIR HANDLING UNITS

FAN POWERED TERMINAL UNITS

CA3000C & CA6000C Cartridge Air Cleaners

About Vacuum Producers

HIGH-POWERED VENTILATORS

Transcription:

APPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM The Technology Center of DuPage is seeking bids for thirty (30) welding booths with fume exhaust system as described below. Companies or individuals submitting bids must include the name of the manufacturer and the model of the welding booth and exhaust system proposed in their bid. Those submitting bids must include the technical specifications of the welding booth and exhaust system proposed and the technical specifications provided by the bidder shall be used for comparison to the specifications required in the bid request. Bids submitted must include any costs for shipping and uploading at to the Technology Center of DuPage and onsite testing of the welding booths and fume exhaust system to be provided. This bid request does not include installation and any electrical, mechanical and duct work. PART 1 GENERAL The following specifications are based on The Lincoln Electric Company Fume Extraction System. Equivalent products and systems that materially and substantially meet or exceed the performance standards permitted by these specifications may be submitted by bidders. 1.01 QUALITY ASSURANCE A. SINGLE SOURCE RESPONSIBILITY Welding Fume Exhaust System equipment and accessories shall be manufactured and furnished by a single manufacturer. PART 2 PRODUCTS 2.01 MANUFACTURER A. Design, materials, construction, and finish of welding extraction system specified, is the minimum acceptable standard of quality. B. Manufacturers, subject to comply with requirements for the welding extraction system, are approved for bidding, provided they meet the contract document specifications, include the following: 1. Lincoln Electric or equivalent C. Products: Product Number listed is for Lincoln Electric use only. Proposed equivalents shall provide the product numbers as required to identify product and product specifications. FUME EXTRACTION SYSTEM Quantity Product Number Product Description 30 K1655-14 LTA 2.0-CW

Wall mounted telescopic articulating fume extraction arm with 360 deg. rotating hood. The working radius ranges from 3 to 7. The nominal diameter of the arm is 8 inches. Spring balance and counterweight allow arm to maintain position. Adjustable throttling valve is in hood. The arm is designed to be positioned 6-12 away from the welding process. 30 K1657-5 CONNECTOR, 8 DUCT - EXTRACTION ARM The polypropylene Connector bolts to the top of the extraction arm and allows for easy connection of the duct drop when used in a central system. 30 S28367-16 MANUAL DAMPER 8, MD8 The manual damper is used to balance the air flow at each fume extraction arm. It is located between the arm and the duct main. The damper is made from galvanized steel, and is 8 inches in diameter with EPDM rubber seal. 1 AD1389-2 FILTER, PRESSURE DIFFERENTIAL KIT Monitors the saturation level of the filter cartridges and adjusts the air volume rate based upon a predetermined setpoint. As filter cartridges become saturated, the controller adjusts the fan speed to maintain the required air volume determined by the air volume setpoint. Kit shall include (1) S23385-48 Pressure Gauge Gauge enclosure NEMA 4X 1 M18464-20 EXT.FAN,50HP,19800CFM,230/460V,12 IN.WG. Mechanical Specifications: Fan housing Steel Dimensions WxLxH 52.5x54.31x59 in Weight 1662 lbs Construction class Class III Inlet 33.56 dia Fan model SQBI-300 Fan speed 1750 rpm Wheel description HD backward Inclined Wheel width 100% Wheel dia. 32.38 in Outlet Velocity 3646 fpm Performance 19,800 cfm @ 12 w.c. (@ 70 deg, 0.075 lb/ft3) Electrical Specifications: Motor design IEC 132 (WEG) Voltage 230,460V/3ph/60Hz BHP 47.4 Power 50 HP

1 AD1283-48 ENV,POWERFLEX 400,50HP,72AMP,IP30VFD The variable frequency drive (VFD) regulates the fan input voltage based on either a differential pressure signal or a signal from the IF-15 control box. UL listed to UL508C, NEMA ICS 3.1, IEC 146. Electrical Specifications: Voltage Tolerance 200-240V +or- 10% 380-480V +or- 10% Frequency Tolerance 48-63 Hz Input phases 3 phase = full rating. Derate for single phase. Displacement pf 0.98 across entire speed range Efficiency 97.5% @ rated amps, nominal line voltage Environment: Altitude Air Temp Humidity 3300ft without derating IP30,NEMA/UL type open = -10 to 50 deg C. 0-95% non-condensing 1 S23385-207 ENV,SILENCER, M18464-20, ENAMEL 75DBA Dual walled, inline, straight duct silencer, acoustic media with fiberglass media protection. Inlet dimensions Outlet dimensions Net Weight (approx..) Pressure drop Construction Internals Fan Connection System Connection 40.25 x22.25 40.25 x30.25 438 lb. (199 kg) 0.54 in wg HRS 14 Ga Casing GALV 2 in. HRS Flange 2 in. HRS Flange Interior/Exterior coating: Interlac 789 DTM Industrial Enamel (2-4 mils) Noise Criterion: Required Position No. opening) Distance Location 75 dba 3 (90deg from Silencer 5 ft Inside Large Space 1 AD1389-3 ON/OFF PUSH BUTTON CONTROLLER Kit includes the following: (1) S21118-91 Enclosure (1) S21130-21 Green Push Button, AB

(1) S21130-46 Red Push Button, AB (1) S22628-5 Push Button, contact block, 2 N.C. S21118-91 ENCLOSURE, 2 ELEMENT, STEEL 30.5mm, Heavy-Duty, Pilot Device Enclosure, Gray, Steel, Surface Mount, 2 Element, 1 Contact Block Depth, NEMA 12, 13. S21130-21 PUSH BUTTON, 30mm Push button, 30.5mm, Green, Type 4x, IP65 wateright/oiltight panel, Double nickel plated terminal screws, Contact material: Silver S21130-46 FLUSH PUSHBUTTON, 30mm Flush pushbutton, 30.5mm, Non-Illuminated, Red, 800T, NEMA Rating: 4/13, 1 NO S22628-5 30mm CONTACT BLOCK, 1 N.C. 1 N.C. Contact Block, 30.5 mm, Base Mount, Non-Metallic, 800T Series 30 AD1221 LAMP/ARC SENSOR KIT This kit incorporates a lamp, sensor, and on/off switch; such that an operator may turn the fan on/off manually or automatically right at the end of the arm. The sensor will turn the fan on when it detects the arc, and off when it no longer detects the arc. The following items are included in the kit: Work lamp, arc sensor, 36-3 wire - 20 AWG, control box, and thermal relay. Specs. Voltage 24 VAC Bulb Halogen, 35W Weight 7.7 lbs 30 S28367-2 AUTOMATIC DAMPERS 8, AD8 Motor operated damper, 8 inches in diameter with galvanized steel structure and EPDM rubber seal. Damper is equipped with Kenlock seals for easy duct mounting. The working range is 0 to 90 degrees. Electrical Data: Drive Torque 8 Nm Running time 8 sec Input Power 24V AC Frequency 50-60 Hz Power consumption 7 W (13VA/3.4A@2ms) 2 S23385-37 IF-15 INTERFACE CONTRL, STATIFLEX 6000 The IF-15 works in conjunction with the VFD to regulate the fan speed based on the number of arms that are demanding air flow. The IF-15 receives a signal from the fume extraction arm to

turn the fan on/off, and/or to change its frequency (speed). The signal output to the VFD is 4-20mA. The input power required to the IF-15 is 24V AC. The IF-15 can serve up to 15 arms. More than one IF-15 can be wired to the VFD as necessary. 1 G3207-303 PLC, 2-4 IF 15 Connections Used to combine the output from up to four IF-15 interface devices into one 4-20ma signal, which is fed into the variable frequency drive. 1 L16480-172 STATIFLEX FB-36-STD/CPC The Statiflex filter bank is a modular dust bank that is designed to accommodate nearly any welding/cutting application. It is equipped with an automatic cleaning mechanism and dust bin below the filter to collect the particulate. The cleaning mechanism is designed to eliminate filter clogging. Inside every filter cartridge, is a patented pulsed air amplifier that disperses compressed air for cleaning. This pulsed air releases the dust collected on the surface of the filter. The frame is constructed of heavy gauge steel tubes and channels and heavy gauge steel sheeting. The entire structure is sealed weather tight with a polyester coating. Neoprene gaskets are used to seal the filter air and weather tight. Install outdoors or indoors. Technical Data: Airflow/cartridge 580 cfm Arrangement (36) cartridges 6 x 6 Inlet Dim. 32 I.D. Outlet Dim. 2-19 1/2 O.D., 2-16 O.D. Compressed Air 65 psi Compressed Air conn. 12 mm push-in fitting CA quality ISO 8573-1 Class 6 Input power 115, 208, 230, 400, 460, or 575 V Working temperature 14 to 122 deg. F Frequency 50/60 Hz Output voltage 24 V AC Power consumption 75 W Safety classification IP 54 / NEMA 12 Applications: MIG-MAG/GMAW welding TIG welding FCAW welding Stick/SMAW welding 36 KP3369-1 FILTER-MERV 16 STATIFLEX FILTER BANK The Cart-MB filter media is an 80/20 blend (Cellulose/Spun Bond Polyester) with a Nano fiber

overlay. Each cartridge is created using a pleat stabilizing technique that ensures correct distances between cartridge pleats. This allows for more effective filter area resulting in better cleaning efficiency. The result is a lower cartridge replacement rate. This filter has a MERV-16 rating based on the ASHRAE 52.2 test. 1 S23273-8 ENV, CTRL BOX FB, PRESSURE, UP TO 64 CART The Cont-C64 monitors filter pressure and ensures cleaning is done only when necessary reducing the compressed air usage. WELDING BOOTHS 1 L15788-XX (30) WELD BOOTH 5 X 5 (3) WALL W/CURTAINS & ARM MOUNTS/BRACKETS Welding booths shall adhere to the AWS (American Welding society) Guide for the Training of Welding Personnel (AWS EG2.0:2006). The booths allow for flexibility and modularity. They allow for flexibility by permitting the instructor to modify the booth configuration in conjunction with possible curriculum changes. Expandability is accomplished by adding more walls to the booth system. All four sides shall provide complete protection of the welding personnel and others in the area from harmful UV rays and hot sparks Construction the panels shall be constructed of fire-resistant material. The panels shall be constructed such that they have a minimum 12 space below the bottom of each panel to allow for airflow. Each panel shall have a support structure of 2 x 2 x 1/8 (wall thickness) steel tubing (or equivalent strength support) and shall be sheeted with a minimum 16 gauge sheet steel. Finish each panel shall be coated with rust inhibiting flat enamel paint. The inside portion of the panels shall be painted black (or equivalent low reflective color) to reduce the propagation of arc flash to adjacent welding personnel. Assembly each booth shall be constructed in such a manner that when the panels are bolted to each other, a self standing, three sided booth shall be the result. Each booth shall be made to be anchored to the floor. With the proper anchors the booth system shall have the ability to be approved for a seismic design category IV. Protection each booth shall be equipped with an arc flash protection curtain. These curtains shall be constructed of approved material such that they

block harmful UV rays emanating from the welding arc. Booth Size (inside dims) (W x D x H) 5 x 5 x 7.5 (Note: for out of position and overhead welding, it is almost always necessary to provide an articulating fume extraction arm to prevent the welding fumes from escaping the booth) (AWS EG2.0:2006). Includes the following: (3) L15788-116 Weld Booth,Lt Panel, 5 x7.5 H (3) L15788-117 Weld Booth,Rt Panel, 5 x7.5 H (46) L15788-118 Weld Booth,Back/Cntr Panel, 5 x7.5 H (19) L15788-119 Weld Booth, Header Tube (54) L15788-114 Weld Booth Post, 4 & 5 FT (30) L15788-8 Weld Booth, Curtain Asbly, 62 W x 66 H (30) S21164-368 Brkt.Mt LTA 2.0-CW to Booth Wall (30) AD1319-5 ENV, Arm Mtg Brkt Fastener Kit ENGINEERING SUPPORT Provide engineering and installation phone support for the electrical and mechanical contractors The successful bidder must provide one system installation manual. This manual must be included with the purchase of the quoted system and shipped with the equipment. COMMISSIONING Provide system start-up, commissioning, and technician support to test and tune the system at initial system operation. Commissioning includes manual damper adjustment, airflow set point, extraction system operation and maintenance. Post installation commissioning includes a point-to-point checklist and sign-off procedure. A minimum of one factory technician will be provided to assist with start-up and commissioning. END OF SECTION