PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Similar documents
2. Backward inclined / backward curved centrifugal wheel fans. 3. Axial / backward curved mixed flow impeller bifurcated fans.

SECTION AXIAL HVAC FANS

DESIGN GUIDELINES FANS PAGE 1 of 7

Tubular Centrifugal Fans

Laboratory Exhaust Systems

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

Filtered Kitchen Supply Packaged Ventilator

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

SECTION CENTRIFUGAL HVAC FANS

HIGH VELOCITY FUME EXHAUST FANS

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Laboratory Exhaust Systems


MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Twin City Fan & Blower

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

FRP Fans: CLUB Series Performance and Technical Information

Bulletin VX05 VANEAXIAL FANS

LINEA Low Discharge Roof Exhausters

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

Laboratory Exhaust Systems

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

forward curved inline duct blowers

Energy Recovery Laboratory Exhaust

SECTION HVAC POWER VENTILATORS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

SECTION AIR TERMINAL UNITS

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Fixed Pitch Vane Axial Fan

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Energy Recovery Laboratory Exhaust

EXHAUST FANS CUD & CUB UPBLAST FANS

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

Centrifugal Upblast Power Roof Ventilators

EcoWatt Products. Advancing Ventilation

Direct Gas-Fired Heating

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Tube Axial Inline Fans

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Tube Axial Fan Page Specifications & Dimension Data Performance Data

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

ROUND CENTREX Centrifugal Inline Fans

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Industry best 5 year fan housing warranty, 1 year motor warranty

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

University of Delaware

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

Industry best 5 year fan housing warranty, 1 year motor warranty

DIrect drive exhaust & supply panel fans

Industry best 5 year fan housing warranty, 1 year motor warranty

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Propeller Upblast Roof Fans

Axial Propeller Panel Fans, PAF-Series

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2.

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

Propeller Hooded Roof Fans

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Twin City Fan & Blower

Laboratory Exhaust Systems. Vektor -H High Plume

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

Roof Upblast and Sidewall Exhaust

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

Twin City Fan & Blower

Good Enough Never Is. Plug Fan SERIES 12

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Centrifugal Filtered Supply Roof Blowers

Inline Fans [ 14 ] * UL is optional and must be specified.

Square Inline Fans with Multi-Directional Discharge

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

TUBULAR CENTRIFUGAL INLINE FANS

Centrifugal Spun Aluminum Products

Fumex. Upblast Roof Exhauster Technical Specifications BULLETIN FX17

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

UPBLAST AXIAL ROOF VENTILATORS

Industrial Mini Vent Sets

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

TU-WAY ROOF VENTILATORS

Transcription:

PennBarry Fan Guide Specification Laboratory Exhaust System: Model vplume This document 2018 PennBarry vplume is a commercial lab exhaust fan that ensures a greater margin of safety by effectively dispersing unwanted exhaust, preventing re-entrainment by other ventilation systems. VPlume applications are several, including elementary schools and high schools. The vplume provides a higher level of safety and health by propelling contaminated effluent higher into the air stream where it becomes diluted before contaminants settle back to building envelope or ground level. The vplume features AMCA type B Spark resistant construction and the widest range of available nozzles in the industry. The centrifugal wheels are aluminum, non-overloading, Airfoil, robotically welded, and dynamically balanced. Product Capabilities - Flow capacity up to 7,100 CFM. User Disclaimer: This document is subject to copyright protection and is proprietary to PennBarry. However, PennBarry Corporation authorizes a limited non-exclusive license to use this document or portions of it for the purpose of preparing written product specifications for the above CSI MasterFormat category. All information in this document as provided by PennBarry is information in nature and is provided without representation or warranty of any kind as to the user or any other party, including, without limitation. Users should consult www.pennbarry.com to verify that this document represents the most current version. Note to Specifier: This product specification guide is written in accordance to the Construction Specifications Institute (CSI) Master Format - 2016 Edition. BEGIN SECTION 23 34 23 1. GENERAL 1.1 SUMMARY A. Section covers vplume High Velocity Exhaust System. 1.2 REFERENCE STANDARDS AND CERITIFICATIONS A. Air Movement and Control Association International (AMCA) 1. 99 Standards Handbook (2003 Edition) 2. 204 Standard Balance Quality & Vibration Levels for Fans 3. 210 Standard Laboratory Methods of Testing Fans for Aerodynamic Performance Rating 4. 211 Product Rating Program Product Rating Manual for Fan Air Performance 5. 300 Reverberant Room Method for Sound Testing of Fans 6. 301- Methods for Calculating Fan Sound Ratings from Laboratory Test Data

7. 311 Certified Ratings Program Product Rating Manual for Fan Sound Performance B. American National Standards Institute (ANSI/AIHA) 1. Z9.5-2003 Laboratory Ventilation C. American Society of Heating, Refrigeration and Air Conditioning Engineering (ASHRAE) 1. Laboratory Design Guide (2002 Edition) D. Underwriter Laboratories Inc. (UL/cUL) 1. 705 Standard for Power Ventilators E. National Fire Protection Agency (NFPA) 1. NFPA 70 National Electric Code F. Occupation Safety and Health Administration (OSHA) 1. 1910.212 General Requirements for Machine Guarding 2. 1910.219 General Requirements for Guarding Safe use of Mechanical Power Transmission Apparatus G. National Electric Manufacturer s Association (NEMA) 1. NEMA MG 1 Motors and Generators 1.3 SUBMITTALS A. Submit in accordance with CSI Master Format 01 33 00 Submittal Procedures B. Exhaust Assembly Performance 1. Provide air performance curves with flow, static pressure, and power 2. Provide sound performance data with sound power levels in eight octave bands and A-weighted overall sound power levels. 3. Provide all primary and bypass air quantities with all appropriate calculations to justify plume height. All values and calculations must be appropriately labeled and marked on an exhaust assembly diagram to ensure proper understanding of calculations. 4. Provide motor electrical characteristics including current, voltage, phase, cycle, enclosure, nominal speed 5. List all accessories equipped with exhaust assembly. 6. List Standard features of exhaust assembly. 7. Provide Dimensional drawings including weight 8. Provide documentation of AMCA and UL certification 1.4 QUALITY ASSURANCE A. Exhaust Assembly Performance Certification 1. Exhaust Assembly must be tested in accordance with AMCA Standard 210 and Standard 300. 2. Exhaust Assemblies ratings must conform to AMCA Standards 211 and 311 3. Exhaust Assembly wheels must be dynamically and statically balanced to comply with AMCA 204, fan application category BV-3 (Balance Grade G6.3) B. Spark Resistance 1. Exhaust Assembly shall be classified for spark resistant construction in accordance with AMCA 99-0401-86 C. Electrical 1. Motors must comply with NEMA standards 1.5 LOGISTICS AND STARTUPS A. Delivery 1. Units must be examined for damage upon delivery. 2. Visual Damage to packaging or product must be noted upon receipt of delivery, as well as must be noted on the BOL or receipt of delivery.

B. Handling 1. Exhaust Assemblies should be handled in accordance with manufacturer s instructions and follow all relevant safety precautions in accordance with OSHA regulations. C. Storage 1. Product must be stored in dry indoor area, protected from potential damage from weather and worksite activities. 2. Long term storage should follow instructions noted in the product s Installation Operation and Maintenance Manual. 1.6 WARRANTY A. Manufacturer s warranty 1. Warranty period is 12 months from date of shipment. 2. See Manufacturer s warranty for specific terms & conditions. 2. PRODUCTS 2.1. MANUFACTURER A. Basis of Design: PennBarry, 605 Shiloh Road, Plano, TX 75074, (972) 212-4700 2.2. LABORATORY EXHAUST SYSTEM PENNBARRY MODEL vplume A. Basis of Design: PennBarry Model vplume B. General Description: Belt drive, roof-mounted commercial laboratory exhaust fan 1. Flow capacity up to 7,100 CFM. 2. Standard atmospheric conditions shall be used to evaluate fan performance (air density 0.075 lb/ft^3) (except as otherwise specified). 3. All fans shall be belt drive, AMCA arrangement 9 according to drawings. 4. Each exhaust fan and plenum shall be equipped with integral lifting lugs for ease of rigging. Lifting lugs shall be placed to minimize the potential for damage during rigging. 5. All fasteners exposed to corrosive exhaust shall be type 316 stainless, excluding motor and bearing fasteners. C. Wheel: 1. Fan impeller shall be non-overloading high-efficiency centrifugal wheels, with airfoil style blades designed and tested to maximize performance. 2. Fan impeller shall be constructed of aluminum in accordance with AMCA B spark resistant construction. 3. Fan impeller and housing shall be statically and dynamically tested and balanced in accordance with AMCA 204-05, Balance Quality and Vibration Levels for Fans. Fan application category shall be BV-3/6.3 and adhere to all constraints appropriate for this category. D. Motors and Drive: 1. Fan motors shall be rated as premium efficiency, NEMA frame, 900, 1200, 1800 or 3600 rpm with a TEFC rating and a 1.15 service factor unless used with a VFD, which will result in a 1.0 service factor. 2. A factory-mounted NEMA 3R disconnect switch shall be mounted to a bolted clip on the fan housing and wired to fan motor by the exhaust assembly manufacturer. 3. All fans shall be belt drive, AMCA arrangement 9 and shall be sized according to the specified drawings. 4. Drive belts and sheaves shall be sized for 150% of the motor horsepower. Drives shall be either adjustable or constant type. 5. Fan motor shall be isolated from outside the exhaust airstream with all motor ventilation originating from ambient, outside air. 6. Motor cover shall be of welded construction.

E. Fan Housing and Construction 1. Fan housing shall be constructed of heavy gauge steel with continuously welded seams. Fan housings with skip-welded seams or other joining methods are unacceptable. 2. Fan inlet shall utilize an aerodynamically designed high-efficiency inlet. 3. Fan housings fabricated of polypropylene or fiberglass, or are bolted together shall not be acceptable. 4. Fan assembly shall be AMCA B spark resistant construction to minimize the sparking potential within the effluent airstream. Other construction types are not acceptable. 5. Fan motor shall be housed outside the exhaust airstream with all motor ventilation originating from ambient, outside air. 6. Fan housing shall have a splash guard mounted behind the wheel to aid in preventing leakage into the lab. 7. Provide fan housing drain for condensate and rain water removal. 8. Provide extended lubrication lines with grease Zerks for easy motor bearing lubrication from fan assembly exterior. Zerks shall be placed on the outside of the fan housing and mounted on welded clips affixed to the fan housing. 9. A bolted oversized access door shall be supplied in the fan housing allowing for impeller inspection and removal of impeller, shaft and bearings without removal of the fan housing. 10. Fan bearings shall be L10-100k concentric lock type. 11. Fan shaft shall be 304 stainless steel with an optional 316 stainless steel. 12. Finish color is gray. F. V-Plume High Velocity Nozzle 1. Nozzle shall be constructed of heavy gauge, continuously welded steel. Nozzles with partially welded seams or other joining methods are unacceptable. Nozzles constructed of FRP or PVC are not acceptable. 2. Exhaust nozzle shall provide a consistent minimum exit velocity of 2500 feet per minute (fpm) or greater at operating conditions. G. Mixing/Bypass Plenum for variable exhaust systems 1. A mixing/bypass plenum shall be provided as shown on drawings. The plenum shall be equipped with a bypass air damper and rain hood with bird screen. 2. The plenum box shall have a minimum of (2) access doors to aid in installation and servicing of the system. 3. For exhaust assembly systems, a mixing/bypass plenum equipped with a bypass damper shall be provided. Mixing/bypass plenum shall be constructed of (heavy gauge steel/single wall panels that are welded together). Bypass/Mixing plenum shall be capable of supporting the fan/nozzle assembly. Bypass dampers shall be protected by a removable rain hood with bird screen constructed of heavy gauge expanded sheet metal. 4. Plenum inlet connections shall be slip fit. Located in the bottom of the plenum assembly per the Pennbarry drawings. 5. Fan isolation damper/s, either gravity backdraft or two position actuated, fabricated of aluminum (if required) shall be located below the fan in the plenum box. 6. All damper actuation and access shall be outside of the contaminated airstream. 3. EXECUTION 3.1. MANUFACTURER S INSTRUCTION A. Follow all manufacturers product usage guidelines and installation instructions 3.2. EXAMINATION

A. Examine fans upon delivery for visual check of components. Verify no visible external damage. Examine area of fan installation for non-satisfactory conditions that may cause increased maintenance or increased difficulty of installation. Notify Engineer of these conditions and correct as is necessary. 3.3. PREPARATION A. Verify Roof openings are square and fan dimensions match. Verify fan motor electrical matches building supply power. 3.4. INSTALLATION A. Follow manufacturer s recommendations as dictated in the Installation, Operations, & Maintenance Manual 3.5. SYSTEM STARTUP A. Follow manufacturer s recommendations as dictated in the Installation, Operations, & Maintenance Manual 3.6. MAINTENANCE A. Follow manufacturer s recommended schedule as specified in the Installation, Operations, & Maintenance Manual B. Failure to comply with proper maintenance will void Manufacturer s Warranty END OF SECTION 23 34 23