Automatic Star Delta Starters IEC : 2012 Compliant Direct-on-Line Starters ISI Marked-BIS Approved

Similar documents
Starters. Overview. Siemens caters with following types of starters to agricultural and industrial sector.

Ph.no / Kanchan Eneterprises. id- DOL Starter Type 3TW42 00 (open execution)

Starting of Induction Motors

Motor Protection Circuit Breaker

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

ADS7 AC Contactor Starters

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Contactor Relays 3TH30

8BK80 Genuine metal-clad single busbar switchgear with Vacuum Circuit Breaker on withdrawable truck upto 36kV

CI-TI Contactors and motor starters Types CI 61 - CI 98

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A

Record SL. Moulded Case Circuit Breaker

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

CI-TI Contactors and Motor Starters Type CI 6-50

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Contactors and Overload Relays

Ktec Contactors and thermal overloads

CNC ROTARY TABLE. Specification

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

Industrial Circuit Protection

RVS-AX Instruction Manual

Mini Contactors CI 4-

Complete protection made easy. Datasheet. hrc fuses BS TYPE

PAC TRAINING PUMP MOTORS

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Contactors and Overloads MC

Catalog. Low voltage General performance IE3 efficiency cast iron motors

Series Motor Protection

Range : 7.5kW to 630/800kW

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Technical Information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

REVISED ATM72 Auto Transfer Module

SOLSTART Instruction Manual

Gear Drive Rotary Screw Air Compressors HP

Crompton Greaves Limited

Ambilin Incorporate.

Question Number: 1. (a)

Single Phase Submersible Pump Starters

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Electronic timers CT-S range Function diagrams

LST SWITCHGEA. Motor Starters. Type MN. . Direct-On-Line Starters. Star-Delta Starters LARSEN & TOUBRO LIMITED. Its all about Imagineering TM

Series CA5 Contactors

Contactor Types CI 61-98

Technical Information

Open Chassis Star-Delta Starter User Guide

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Technical Information

Installation Manual for DC Injection Brake Units

Technical Section: Miniature Circuit Breakers

Full Voltage Starting (Number of Starts):

UPDATED APRIL Motor Protection Concepts and Type 2 Co-ordination Charts

ACS motor protection circuit breakers KT 7 Introduction

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Range of Starters... for Every Need CITATION STARTERS

Leadership driven by innovation

Partnership that you can trust. LV Switchgear Motor Control Products.

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

All round protection guaranteed

S M A R T P U M P I N G HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Protection Circuit Breakers 3VU13 and 3VU16

Spectra SP. Range of SD & SDF 32A to 800A

Auxiliary Relay. Type P8n, PQ8n, PN8n

Motor Starting Solutions Open Type Version, in Kit Form

10. Starting Method for Induction Motors

22AF 40AF AF 150AF 225AF 400AF 800AF

Softstarters Type PSS. Softstarters. General information

Phone: Fax: Web: -

Application Description

Changeover & Bypass Sw it ches

About us. Switchgear Factory, Mumbai

CANTILEVER TABLE. Specification. Features: Dual lead worm gear drive Hydraulic clamping Option with direct measuring encoder

Micro Contactor MA Series

Auxiliary Relay. Type RXP8n, RXPQ8n

Electromagnetic Industries LLP

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

GE Power Controls. Low Voltage HBC Fuselinks. For more information, please contact: MAJESTIC GLOBAL LTD.

SDS Enclosed Star-Delta Starter User Guide

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

A9K. MCB, RCCB, Isolator

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

Flame Proof Motors For Hazardous Environment JHX

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

AC MOTORS. Bangalore, India

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

Bimetal Overload Relays 3UA and 3UC

Spectronic-SP Air Circuit Breaker

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Transcription:

Agriculture Starter complying to latest standards Automatic Star Delta Starters IEC 60947-4-1: 2012 Compliant Direct-on-Line Starters ISI Marked-BIS Approved www.siemens.co.in

Tried, Tested and Trusted Start with Siemens Agriculture Starters For more than 125 years, Siemens has been developing and manufacturing world-class, control products. Siemens offers a wide range of starters to cater to diversified demands from Agriculture Sector.These products are specially designed to provide smart, easy and reliable motor starting solution. They employ tried and tested Siemens contactors and relay and this ensures the right start for motors requiring direct online starting or star delta starting. 2

Direct on line Starter (DOL) RAJA + 3TW7291-1A... Range: 0.25kW to 7.5kW 0.33HP to 10HP Method of starting A. DOL starting method: The most economical and popular method of starting squirrel cage induction motors, is direct-online, where the starter is connected directly across the supply. However, the starting current at the moment of switching Direct-on-line can be as high as 6-8 times the rated current. Advantages: High starting torque, shorter starting time, simple construction and wiring, space saving etc. Disadvantages: High starting current Applications: DOL: As we know, A direct on line starter can be used if the high inrush current of the motor does not cause excessive voltage drop in the supply circuit. It can be used to start small agriculture water pumps, compressors, fans and conveyor belts.etc. 3

Construction IS/IEC 60947-4-1 CM/L-7800027718 Contactor: The DOL starter up to 10 HP is fitted with 3TS3 Contactor. This contactor is specially designed by Siemens considering the requirements of industry as well as agriculture. Considering the specific need of the agricultural pump set applications, Siemens has designed a special wide band coil (200-400V). This coil operates reliably even when there is wide voltage fluctuation. The Starters will now come with 3TS Contactors which will in turn make the starter more reliable with enhanced electrical and mechanical life. 4

Bimetal Overload Relay: The RAJA direct-on-line starter is fitted with 3UW5 relay. These relays are computer calibrated and therefore, offer accurate protection. The main benefit of this bimetal relay is the built-in single phasing protection in addition to the overload protection. Relay has Automatic reset function after cooling time of 4 sec approx, completely reduce Manual dependency. Push buttons Push buttons are used for switching ON and OFF the starter. Twin push button comes with Locked Off feature which helps in avoiding nuisance switching ON of pump. Operation: In DOL starting, the ON push button is pressed, which energizes the contactor coil, thus switching on the circuit. When the OFF push button is pressed, the contactor is de-energized, switching off the circuit. The bimetal relay under normal functioning of motor plays no active part in the starter. But under overload, single phasing or locked rotor conditions of Motor, the bimetal relay cuts-off the supply to the contactor coil, tripping the circuit. The contactor itself provides the necessary novoltage protection in so far as it will drop out in the case of a supply failure, and for restarting on resumption of supply, the ON push button will have to be pressed again. Reliability: 3TW72 range of DOL starters are having option of 200-400 V Coil voltage which takes care of wide fluctuations in supply. Accurate protection under single phasing & overload. With ISI marking, it ensures more safety for the end user. With 3TS contactors fitted into it, ensures more electrical and mechanical life of the Starter. With Locked off feature, ensures that undesirable switching on of the Starter is prohibited. No Auto start only Auto reset of Bimetal relay and it needs Manual Acknowledgement to again ON the Starter. 5

Key Highlights Latched OFF feature available Fitted with 3TS Contactors and 3US over load relays RAJA Starter with ISI mark 6

Technical Details of the Starter Table A: Motor Rating At 415V 3ph 50Hz Starter Type HP kw Range Relay 3UW51 Code ## Back-up Fuse Rating HRC type 3NA 7 Rewirable Cu Cable (mm 2 ) size Max. Full Load Current (Amp) 3Ph, 415V, 4P Squirrel Cage IS 8789:1996 Table 4 3Ph, 415V, 2P Submersible motor IS 9283:1995 Table 2 1Ph, 240V, CSIR or Split-Phase IS 996-1979 Table 9 0.33 0.25 3TW7291-1A* 64 0.63-1 0J 2A 36 SWG 1 3.8 0.75 0.55 3TW7291-1A* 66 1-1.6 1A 6A 34 SWG 1 1.7 7 1 0.75 3TW7291-1A* 68 1.6-2.5 1C 6A 27 SWG 1 2.2 7 1.5 1.1 3TW7291-1A* 69 2-3.2 1D 10A 26 SWG 1 2.9 3.25 13 2 1.5 3TW7291-1A* 71 3.2-5 1F 16A 25 SWG 1 3.8 4.5 18 3 2.2 3TW7291-1A* 72 4-6.3 1G 16A 24 SWG 1.5 5.1 6.5 5 3.7 3TW7291-1A* 74 6.3-10 1J 16A 21 SWG 1.5 8.1 10 7.5 5.5 3TW7291-1A* 75 8-12.5 1K 25A 19 SWG 1.5 11.4 14.5 7.5 5.5 3TW7291-1A* 77 10-16 2A 25A 18 SWG 2.5 10 7.5 3TW7291-1A* 78 12.5-20 2B 32A 18 SWG 4 15.4 19.5 * Code for operating coil voltage, 50 Hz (B for 200-400V without tolerance W for 415V) Spare list Sr. No. Description Order No. 1 Contactor for 200-400V 3TS30-10-0AZ608K 2 Contactor for 200-400V 3TS32-10-0AZ608K 3 Contactor for 415V 3TS30-10-0AR008K 4 Contactor for 415V 3TS32-10-0AR008K 5 Relay 3UW51 02-## 6 Coil for 200-400V 3TY7 403-0AZ6 7 Coil for 415V 3TY7 403-0AR0 8 1NO Contact Block 3SB54200B 9 ON & OFF Push Button # # contact sales Raja + Direct-on-line Starter (For Single Phase connection) Wiring Diagram for Single-Phase Motors Note: Connect 3/L2 to 2/T1 by cable of suitable size. (Max. 4mm 2 ) 7

Automatic Star Delta Starter 3TE7291-0A ASD-11 Starter (Self reset) Range: 7.5kW to 18.5kW 10HP to 25HP Current/rated op. current I y = Current in Y-connection I D = Current in connection Synchronous speed Speed/rated speed In star delta starting, initially the motor windings are connected in star. This reduces the starting current by 1/3 rd of the full load current also the voltage by (1/ 3) of the rated value. As the torque is proportional to the square of the voltage, the starting torque also get reduced to 1/3rd of it s full load value. Once the motor attains approximately 80% of the rated speed, the windings get connected in the delta formation. Thus by star delta starting, the starting current is reduced to 2 to 2.5 times the rated current unlike DOL starting, where it is 7 to 8. Advantages: low starting current Disadvantages: Low / medium starting torque, longer starting time, less simpler construction and wiring, requires more space etc. 8

construction Automatic Star Delta Starters fitted with 3TS contactors Construction: It consists of a star-delta timer (3RP), contactor (3TS3), and overload relay (3UW51), Operation: In this starter, the changeover from star to delta is done automatically after a preset time by using a timer. 9

Key Highlights of Star Delta Starter Latched OFF feature available Fitted with 3TS Contactors Compact Size 10

Technical Details of Automatic Star Delta Starter Table A: Automatic Star - Delta Starter Type Ref: 3TE7291-0A Motor Output at 415V (kw/hp) I(fl) 4 Pole Squirrel cage motor Line current (A) Phase current (A) Contactor Line Contactor Delta Contactor Star Type Reference Recommended Overload relay at 50ºC Type - Code Relay Range (A) Recommended Fuse Switch Type Back up HRC fuse rating(a) Recommended Cu Cable size (mm 2 ) Incoming (from supply) 7.5/10 16 9.2 3TS32 10-0A*08K 3TS32 01-0A*08K 3TS32 10-0A*08K 3UW51 02-1J 6.3-10 3KL812 20 2.5 1.5 9.3/12.5 19.5 11.2 3TS32 10-0A*08K 3TS32 01-0A*08K 3TS32 10-0A*08K 3UW51 02-1K 8-12.5 3KL812 25 4 2.5 11/15 23 13.2 3TS32 10-0A*08K 3TS32 01-0A*08K 3TS32 10-0A*08K 3UW51 02-2A 10-16 3KL812 25 4 2.5 15/20 32 18.4 3TS33 00-0A*08K 3TS33 00-0A*08K 3TS32 10-0A*08K 3UW52 02-2B 12.5-20 3KL812 50 10 4 18.5/25 38.5 22.2 3TS33 00-0A*08K 3TS33 00-0A*08K 3TS32 10-0A*08K 3UW52 02-2C 16-25 3KL812 50 10 4 * Code for operating coil voltage 50 Hz (Z6 for 200-400V, R0 for 415V) Outgoing (tomotor) Other Tables: AC Input Voltage 230V-400V 380V-440V Star-Delta Timer: MLFB 3RP15 76-1NP20 8K 3RP15 76-1NM20 8K Sr. No. Description Spares: Order No. 1 Contactor for 200-400V 3TS30-10-0AZ608K 2 Contactor for 200-400V 3TS32-10-0AZ608K 3 Contactor for 415V 3TS30-10-0AR008K 4 Contactor for 415V 3TS32-10-0AR008K 5 Relay 3UW51 02 Refer Table A 6 Relay 3UW52 02 Refer Table A 7 Coil for 200-400V 3TY7 403-0AZ6 8 Coil for 415V 3TY7 403-0AR0 9 1NO Contact Block 3SB54200B 10 ON & OFF Push Button # # contact sales 11

Single line diagrams: DOL (Direct online starters) RAJA Direct-On-Line Starter (for Remote Operation) 3TW72 91-1A S0 - OFF O (Red) Button S1 - ON I (Green) Button Q1 - Contactor K1 - Bimetal Relay with SPP feature S01 - Remore OFF Push Button S11 - Remote ON Push Button Diagram shows connections made for contactor coils rated 200-400V (wide-band), 415V (320-455V), 50Hz. For remote operation disconnect the wire between terminal 5/L3 on contactor and terminal 96 on the relay. Connect the remote OFF S01 push button as shown. Connect remote ON S11 push button parallel to S1 as shown. 12

ASD (Fully automatic start delta starters) Q1 - Line Contactor (+2NO) Q2 - Star Contactor (+1NO+1NC) Q3 - Delta Contactor (+1NC) S1 - ON Push Button S4 - OFF Push Button Q4 - Star Delta Timer with 1NO Instantaneous and 1NO Delayed Aux. Contact K1 - Bimetal Relay From Supply L1 L2 L3 S1 3 4 Q4 Q2 Q3 A1/A3 17 A1 1/L1 3/L2 5/L3 21 13 A1 1/L1 3/L2 5/L3 21 A1 1/L1 3/L2 5/L3 13/(23) 23/(13) A2 18 28 A2 2/T1 4/T2 6/T3 22 14 A2 2/T1 4/T2 6/T3 22 A2 Q1 2/T1 4/T2 6/T3 14(24) 24/(14) 1/L1 3/L2 5/L3 K1 2/T1 4/T2 6/T3 S4 95 96 W2 U2 V2 To Motor U1 V1 W1 To Motor Diagram shows connections made for contactor coils operating range 200-400V 50Hz (wide band) & coil rated 415V 50Hz. (13), (14), (23), (24) applicable incase of 20 HP & 25 HP. 3TE72 91-0A / Automatic Star-Delta Starter Coil Voltage / Coil Operating Range = V 50Hz Motor Output at 415V (kw/hp) Relay Range 3UW51/52 (A) Recommended Backup Fuse type 3NA3(A) Recommended Cu Cable (mm sq.) Incoming Outgoing 7.5 / 10 6.3-10 20 2.5 1.5 9.3 / 12.5 8-12.5 25 4 2.5 11 / 15 10-16 25 4 2.5 15 / 20 12.5-20 50 10 4 18.5 / 25 16-25 50 10 4 13

DOL Dimensional Drawing Raja Direct On-Line Starter Mounting dimensions 154 x 70 mm and hole dia 6.5 mm 14

ASD Dimensional Drawing Automatic Star Delta Starter Mounting Dimensions 259 x 219 and hole Dia 7.0mm Fig. 8: Dimensional Details for 3TE72 91-0A** 15

Your partners Sales offices: Mumbai Business Centre-1 Thane Belapur Road Thane - 400 601 ( : +91 22 39663000 Fax: +91 22 39663721 Mr. Satish Herlekar ( : 022-39677403 Mobile: +91 9820002421 Email: satish.herlekar@siemens.com Ahmedabad 3rd Floor, Prerna Arbour Girish Coldrinks Cross Roads Navrangpura Ahmedabad - 380 009 ( : +91 79 30927600 Fax: +91 79 30927699 Mr. Pradeep Ajadia Mobile: +91 9099052797 Email: pradeep.ajadia@siemens.com Pune Tower B/701-705, ICC Trade Tower 403A, Senapati Bapat Road Pune - 411016 ( : +91 20 30466000 Fax: +91 20 30466060 Mr. Kailas Kulkarni ( : 020-30466078 Mobile:+91 9921216399 Email: kailas.kulkarni@siemens.com Gurgaon Plot No -78, Tower B Jagatjit Industries Building (JIL) Opposite SBI Academy, Sector-18 Gurgaon - 122015 ( : +91 124 2842000, 3810200 Mr. Brijendra Yadav ( : 0124-3846022 Mobile: +91 9910598050 Email: brijendra.yadav@siemens.com Jaipur 6, Park Street Opp. Pink City Petrol Pump M.I. Road Jaipur - 302 006, Rajasthan ( : +91 141 5152108 Fax: +91 141 2370482 Kolkata 3rd Floor, 43, Shanti Pally Rash Behari Connector E.M. ByPass Kolkata 700042, India Mr. Avijit Paik ( : 033-30172022 Mobile: +91 9830258141 Email: avijit.paik@siemens.com Jamshedpur Roshan Tower Main Road, Bistupur (2nd Floor) Jamshedpur - 831001 ( : +91 657 6682201 Mr. Sanjoy Kumar Dey ( : 0657-6682213 Mobile: +91 9051044110 Email: sanjoy.dey@siemens.com Bengaluru 1st Floor, Jyoti Mahal No. 49, St. Marks Road Bengaluru - 560 001 ( : +91 80 33422000 Fax: +91 80 33424131 Mr. Manish Pillai ( : 080-33422097 Mobile: +91 9880575897 Email: manish.pillai@siemens.com Hyderabad 5-9-19, 4th & 5th Floor Laxmi Narasinh Estate Opp. Secretariat Road Saifabad Hyderabad - 500 004 ( : +91 40 30922500 Fax: +91 40 30923145 Mr. Durga Prasad ( : 040-30922638 Mobile: +91 8008552075 Email: goriparthi.durgaprasad@siemens.com Chennai 4th Floor, ETA Mount Central Seethakathi Business Centre, Mount Road Chennai - 600006 ( : +91 44 30474000 Fax: +91 44 30474080 Mr. Pradeep Indulkar ( : 080-33422116 Mobile: +91 9900134714 Email: pradeep.indulkar@siemens.com Coimbatore 1st Floor, Senthil Towers 1078, Avinashi Road Coimbatore - 641018 ( : +91 422 3076300 Fax: +91 422 3076310 Mr. Sivakumar A. ( : 0422-3076300 Mobile: +91 9361281643 Email: a.sivakumar@siemens.com User Support Pune Tower B/701-705 ICC Trade Tower 403, A, Senapati Bapat Road Pune - 411016 Mr. Sandip Pachapurkar ( : 020-30466122 Mobile: +91 9594947303 Email: sandip.pachapurkar@siemens.com Bengaluru Shed No. 1 & 2 SY No. 26 & 27, Plot No 1 A Systems Campus Peenya Industrial area, Phase 2 Chokkasandara Village Yeshwantpur Hobli Bangalore - 560058 Mr. Shankar Narayanan ( : 080-33422529 Mobile: +91 9945188837 Email: narayanan.shankar@siemens.com Siemens Ltd. Digital Factory Motion Control R&D Technology Centre Thane Belapur Road, Airoli Node Navi Mumbai - 400 708 www.siemens.co.in XX-XX-XXX-XXX-XXXX For more information call us on 1800 209 1800 For Life Cycle Support of Products, Systems and Solutions call us on 1800 209 0987 Product upgradation is a continuous process. Hence, data in this catalog is subject to change without prior notice. For the latest information, please get in touch with our Sales Offices.