NESC 2007 FLAME RESISTANT CLOTHING

Similar documents
January 30, Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT. Re: NFPA 70E Hazard Assessment. Date of Visit.

Illinois State University. Electrical Safety Procedure

Future Proof Your Arc Flash Assessment

NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces. Table Hazard Risk Category Classification

OSHA Update. Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926)

Appalachian Power Company Policy No. 2 Cover Up Procedures. Policy Summary:

ARC FLASH MANAGEMENT REVIEW. October 2017

The New 2017 National Electric Safety Code Overview and Significant Changes. Presented by. Mickey Gunter October 28, 2016

Electrical Safety CSA Z462 & NB Regulations

INDEX. Long Sleeve T-Shirt One pocket with harness tape configuration. Hooded Sweatshirt Zipper front closurre with 2 pockets

Short Circuit/Coordination & Arc Flash Study Specifications

BP-Husky Refinery Toledo, OH

take to complete our safety compliance

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

What NENS Means for You

TECHNICAL TOPICS UNIVERSITY. General Electrical Safety BEST PRACTICES

Integrating Roles Within Electric Utilities to Achieve Arc Flash Safety. MIPSYCON Presenters Neil Stiller & Bob Cooke

NFPA 70E Electrical Safety in the Work Place. R. Casey 2/1/05

Hazards SAFETY CORNER. of Establishing an. Work Condition

Electrical Safety in Die Casting

AVOIDING ELECTROCUTION HAZARDS

Salisbury by Honeywell 101 E. Crossroads Pkwy., Ste. A Bolingbrook, IL U.S.A. Toll-free: U.S.A. Toll-free Fax:

PRO-WEAR ARC FLASH PROTECTION CLOTHING & KITS

Electrical Safe Work Practices

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise

Frequently Asked Questions

Energized Electrical Work

Second Correlating Revision No. 3 NFPA [ Section No ]

PROPOSED RULEMAKING BOARD OF COAL MINE SAFETY 25 PA CODE CHAPTER 208 PREAMBLE

New 2002 NEC. Arc Flash Hazard Marking Requirement Cooper Bussmann, Inc.

ELECTRICAL PERSONAL PROTECTIVE EQUIPMENT STANDARD

Backfeed, Safety, and Work Practices

Safety Training Topic ELECTRICAL SAFETY

Medium Voltage Controllable Fuse

Fire pumper brake work was put off

Unrestricted. S.Mukhopadhyay

Arc flash hazard mitigation

Live Line Technology Arc Flash suits

Add face and hearing protection to any hard hat with ELVEX QuickSnap System in just four easy steps!

SAMPLE. Arc Flash Study ABC CONTENTS. City, State. John D. Aeiker, PE, CSP Consultant

Fugitive and Combustible Dust

AECI Health, Safety & Environmental Procedures. Electrical Safety

BP OIL -- TOLEDO REFINERY

A REPORT TO THE BOARD OF COMMISSIONERS OF PUBLIC UTILITIES. Electrical. Mechanical. Civil. Protection & Control. Transmission & Distribution

In the November 2006 issue of FireRescue, ( Easy

Evaluating Stakeholder Engagement

ENERGIZER BATTERY MANUFACTURING ST. ALBANS, VERMONT

600 V Class Switchgear ( with power circuit breakers or fused Opening hinged covers (to expose bare, energized electrical - Note 1. switches) --Note 4

"ELECTRICAL SAFETY IN THE WORKPLACE"

Safety Resources p r o d u c t i n d e x

ESSENTIAL SAFETY RESOURCES

Excavation worker killed by flying rigging when hook fails

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

London s residential EV Charging Future

Stay Safe Around Electricity Teacher s Guide

Appendix C. Parking Strategies

Operator Manual. The most important component is you. This operator manual. has information for. all models of series. B plus some options and

Live-line transmission lines upgrade projects. First-in-Africa project

DEPARTMENT OF TRANSPORTATION. National Highway Traffic Safety Administration. [Docket No. NHTSA ; Notice 2]

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks

BLACK ICE FRIEND OR FOE

-and- Peter W. Gurnham, Q.C., Chair. ("Utility"), made application on January 14, 2015, to the Nova Scotia Utility and Review

Electrical Safety Program

When Grids Get Smart - ABB s Vision for the Power System of the Future

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Ladder Safety Policy

Substation Lightning Protection. Document Number: 1-11-FR-11

VEHICLE TOWING SAFETY

120-ELECTRICAL SAFETY PROGRAM

Presenter s Notes SLIDE 1

Portable Ladder Safety

Founded in 1898 by engineers. Proud partner of industry and government for over 100 years Blending tradition with forward-thinking vision

By Renee Changnon, A Brighter Future. TreeHouse Shines Light on Solar Solutions

Electrical Safety - Protecting Yourself Against Electrical Injuries. from NIOSH Electrical Safety Student Manual

Between the Road and the Load Calculate True Capacity Before Buying Your Next Trailer 50 Tons in the Making

THE STATE OF SAFETY IN THE REFUSE INDUSTRY

Two Recent Case Studies in the Mining Industry

Arc-Flash Mitigation Technologies. Dennis Balickie

Before the. Hearing on. Takata Airbag Ruptures and Recalls

Operator Manual. This operator manual has. information for all models. of series M plus some. options and accessories. Some of the illustrations

Supply Chain Implications of Market Disruption and Emerging Technologies

Ontario Operations MAINTENANCE STANDARD PROCEDURE. Table of Contents. Electrical Electrical Department Energized Electrical Work Procedure

Final Administrative Decision

INTRODUCTION: INITIAL TRUCK OBSERVATIONS AND RECOMMENDATIONS:

The Electrical Arc Flash Hazard

Medium Voltage Cables for PermaLife Nuclear Utility Applications

Hearing before the U.S. Senate Committee on Commerce, Science, and Transportation

Draft Agenda. Item Subject Responsible Time. 4. GAS INFORMATION SERVICES PROJECT IMO 10 min. 5. OPTIONS FOR GAS BULLETIN BOARD SYSTEM IMO 15 min

Arc Flash Resistant Equipment

A TECHNICAL INSPECTOR S GUIDE TO THE 2012 FSAE RULES PART 2 DRIVER S EQUIPMENT & EXTERIOR GENERAL

California State University Bakersfield Electrical Safety Program. Revised November 2017

Reducing. with Current. arc flash note 2. points of interest. Why Use Current Limiting Fuses. By mike lang, Principal field engineer

Radiological Preparedness & Emergency Response. Session IV. Scenario. PPE and Decontamination Principles

Mark Lyvers LLC / Cooper Bussmann Arc Flash Script Script to accompany PowerPoint on New 2002 NEC Arc Flash Hazard Marking Requirement

The Shocking Truth About Electrical Safety Teacher s Guide

Toyota Motor North America, Inc. Grant of Petition for Temporary Exemption from an Electrical Safety Requirement of FMVSS No. 305

Utility and project update 2-3 Project description 4

GE Arc Vault TM Protection System. By Mark Clapper GE Specification Engineer. Introduction. What Variables Contribute To An Arcing fault?

Please use the Q & A utility to ask us any questions concerning the material being presented.

NON-FATAL ELECTRICAL INJURIES AT WORK

Electrical Safety. Recognizing & Controlling Hazards

Transcription:

NESC 2007 FLAME RESISTANT CLOTHING Written by: Hugh Hoagland Published: Friday, February 1, 2008 by Incident Prevention, Inc. The NESC 2007 standard sets forth quite a challenge to electric and communication utilities in the area of clothing. The new standard, which becomes law in several states, says, "The employer shall require employees to wear clothing or a clothing system that has an effective arc rating not less than the anticipated level of arc energy." This compliance is required by January 1, 2009. The following challenges will require strategies and decisions by utilities to comply with the NESC standard. Challenge 1: What about face protection? The standard doesn't address this at all, leaving many utilities confused. Even though NESC doesn't address it, OSHA general requirements for PPE require addressing protection of any body part exposed to a recognized hazard. There are four approaches. One is to ignore the face protection issue. Until something happens or OSHA makes a clear statement on this issue, some companies refuse to move at all. However, inaction can be detrimental to employee safety and morale. The NFPA 70E approach is to require face protection at 4 cal/cm2 exposure (HRC 2 exposure bottom limit), but the 2009 version is set to make a change of this to require face protection at 1-2 cal/cm2 exposure. NESC doesn't address face protection but requires clothing protection at 2 cal/cm2. Some utilities are citing a study by Alan Privette showing that arc flashes generally require almost 3 cal/cm2 to cause a seconddegree burn when the exposure time is less than 0.5 seconds. Some utilities are choosing not to implement face protection at low-level exposure to allow line workers to have less constraint on their vision in doing hot line work in lower energy exposures (of course safety glasses will still be required at all levels). The second approach is to require a face shield. This is an approach that is easier for meter service, substation workers and power plant workers but more difficult for line workers when climbing. Using a face shield when working from a bucket is easier than when climbing, but there is strong resistance from linemen and management for using a face shield in T&D because of fogging and other issues. From a protection perspective the face shield alone leaves part of the face and neck unprotected in some scenarios. Energy can come up under a face shield, especially when the worker is looking up (think about an older worker using his or her bifocals). Currently, this is the most frequently considered option.

The third approach is a newer one. Just two years ago Paulson Manufacturing and Salisbury came out with an Arc Goggle. The goggle is designed to be used with a balaclava to protect the face. Currently, NSA (National Safety Apparel) has a rating on a goggle/balaclava combination and Guard-line has a balaclava designed to totally interface with the arc goggle. The best design is to have a balaclava that leaves no skin exposed to the arc. This approach allows for full face protection and is less costly than most hoods designed for use over a hard hat and easier for the average line worker to wear. It also eliminates the additional hazard of shock when wearing cloth over a hard hat. Most utility rules would make this unacceptable in hot gloving line work. The other huge advantage is the price of the goggles, which is in the $100 range. Goggle and balaclava should be tested in accordance with ASTM F2178 as a hood assembly to ensure compliance and should be used in the configuration tested. The fourth approach is to use arc flash over-the-hard-hat hoods. This is common in industrial plants where live-line medium voltage work is very uncommon. In substations, many vault situations and power plants, these types of hoods are very simple to implement. However, it is impossible for many line worker situations. Arc flash hoods are actually a hazard for line workers for several reasons. First, arc flash hoods are NOT dielectric and would be on the outside of the hard hat/hard cap. When it's raining or wet (storm restoration work), the arc flash hood would be an additional shock hazard for the line worker. Additionally, the limited vision, fogging and reduced hearing are issues that the goggle helps limit while still providing 360 protection to the head, neck and face. The current hood/goggle combo is rated 38 cal/cm2, but with a design that can be worn underneath the dielectric hard hat and not increase shock hazard. These are also less susceptible to fogging than many of the hood systems. Challenge 2: Arc Flash Hazard Calculations Utilities have a great challenge in this regard. Utilities were the first industry to do large scale arc flash studies and calculations. Duke Energy developed the first arc flash calculator and Ontario Hydro further perfected this type of tool in the ArcPro software introduced in the mid-1990s. But most of the utility research stopped there. Now there is a reasonable consensus standard for industrial settings in IEEE 1584, but this standard has many weaknesses for utilities. In the 480V range it can be helpful, but the NESC 2007 does not require calculations for the secondary system opting for a comprehensive flame-resistant clothing requirement for all secondary hot work. IEEE 1584 is due for a major overhaul (funding is about 50% complete), but the current plan still focuses on industrial electrical systems and has no current plans to include

transmission voltages at all. EPRI has considered a utility-focused study but funding is not yet in place. Some arc flash correlation work has been done on transmission lines. This work has been incorporated into ArcPro calculations, so they are still the most accurate for T&D. ArcPro's limitations are speed and ease of use. No software company has yet to incorporate ArcPro modeling into a CAD/CAM system for utility use like the IEEE 1584 equations. Several companies have the IEEE 1584 formulas built right into their software so an industrial plant (or even a power plant) can model their system with software like SKM, EasyPower, or EDSA. ETAP and Milsoft are both more focused on utility design and have recently added IEEE 1584 to their packages, but this is not the best option for utilities on the primary side particularly. With these types of packages, the engineer can do a fault current and coordination study and an arc flash study including printing of labels in the software. This will be the method in the future and the leading software companies are rushing to fill this need for utilities as they have been doing for the industrial world. Since IEEE 1584 has no data in utility ranges, it reverts to extrapolations from mostly lower voltage data or antiquated equations that, though adequate for limited use in an industrial plant, will not work for utilities. Testimony to OSHA points out that these equations predict second degree burns from 500 kv transmission lines at 46 feet away (they are only required by law to be 40 feet off the ground). To my knowledge, no one has ever been burned this far away by an arc in these lines. The NESC 2007 has Tables 410-1 and 410-2 giving arc flash guidance and requires performing an arc hazard analysis. Most companies are opting to do their analysis using ArcPro 2.0 from Kinectrics, since the NESC tables only cover some of the T&D situations. The numbers from these tables came from ArcPro calculations, so using ArcPro is a reasonable approach. Challenge 3: Upper torso protection in summer balanced with heat stress issues A note in NESC acknowledges that this could be an issue and allows for exemption if the company determines something like heat stress is a greater hazard, but it is not defined. Three options are being seriously considered by most utilities. Flame-resistant t-shirts for non-energized work and adding a FR long-sleeved shirt for

additional protection. NSA, Workrite, Bulwark, Tyndale and others offer flame resistant t-shirts. Three options are on the market today: GehringGuard is a new lightweight material developed to help protect Marines from IED attacks, Pro-CFR Knit from SSM has captured a large market share since its inception, and Indura UltraSoft Knit has entered the market in the past two years and is gaining market share. Additional clothing such as arc flash raingear or coveralls. NASCO or Neese are two common brands (See Using Rainwear as a Switching Jacket by Hugh Hoagland, IEEE 1997). Specialized shirts. Riverside Manufacturing has a patent pending approach in the Frontline double-layer shirt. This shirt has an arc rating of 23-25 cal/cm2 on the front panels of the shirt depending on the style. With other PPE such as gloves and sleeves, the worker can be better protected in the areas that are most likely to get hit with electric arcs when greater protection is required. The Frontline shirt even offers a cape back vent with Nomex netting that has been arc tested. Challenge 4: Barehand Work for Transmission and Arc Rating This challenge is most apparent in the summer. Most barehand work is done on transmission lines and the energy levels are not normally high; but with barehand work, IF something goes wrong, the worker would be IN the arc. I have recommended to NESC that they require barehand workers to wear flame-resistant, conductive suits much like the approach taken for secondary systems (the only suits used are from Euclid and have an arc rating of about 8 cal/cm2 determined several years ago). This challenge is ongoing, but most utilities that do barehand work must depend on work practices to prevent electric arc. Challenge 5: Providing or Requiring FR clothing OSHA, NESC and even NFPA 70E to a great extent have sidestepped the issue of employer provision of FR clothing. The issue will become more intense as OSHA moves forward on a new 1910.269 standard (proposed June 2005), but this may not be addressed. Companies are looking for more sources of FR clothing, and much of the FR clothing production is no longer in the U.S. This excludes most of the specialty companies, but the largest FR clothing companies are manufacturing in South America, Africa, China and other countries. This challenge requires more due diligence on the part of the utilities. Workrite, Bulwark, Walls Outdoors, Carhartt, Riverside Manufacturing and Tyndale are all brand names associated with quality clothing produced outside the U.S. I have full confidence these companies will address the safety issues that confront them, but the customer must ask

the questions about quality controls and make informed decisions about safety. Challenges have always been part of the utility culture. Our companies are wellequipped to ask the hard questions and to make the hard decisions to change cultures and methods that are not serving worker protection and productivity. About Hugh Hoagland Hugh Hoagland is among the world's foremost experts on electrical arc testing and safety. His career change began with safety testing at LG&E Energy, later, he worked as R & D Director for NASCO, a manufacturer of protective outerwear solutions. He has helped develop most of the arc-resistant rainwear used in the world today as well as creating the first face shield to protect against electric arcs. Before moving to full-time training and consulting. Hugh worked for Cintas developing their strategy for meeting the needs of OSHA 1910.269 and NFPA 70E standards before moving to full time training and consulting. He has helped development of legislation and standards in both the US and Europe. He sits on several industry committees and is a featured speaker at safety conferences and events. Learn more about Hugh Hoagland at www.e-hazard.com