Carter Hydrant Pit Valve 4th Edition EI 1584 Model 60554

Similar documents
Hydrant Valve In Accordance With Bulletin API Model SM Maintenance & Repair Manual. January 2011

PRESSURE REDUCING VALVE

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

Carter Ground Fueling Underwing Refueling Nozzle Model 64250

Carter Ground Fueling Pressure Refueling Nozzle Model 64348

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

1. All aircraft fueling equipment shall have a Filter/Separator or a Full-Flow Fuel Monitor.

Series 758 FireLock Actuated System Valve

800 Series Control Valves

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

Series 756 FireLock Dry System Check Valve

Model INTERNAL/BOTTOM LOADING VALVES SM Maintenance & Repair Manual. July Applicable addition manuals: None

Carter Ground Fueling Pressure Refueling Nozzle Model 64348

Carter Underwing Refueling Nozzle. Model 64349

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

Maintenance Manual HYDRANT SHUTOFF VALVE F352 / F353 SERIES

Maintenance & Repair Manual

Aviation Ground Fueling Solutions

Maintenance Manual. Dry Break Quick Disconnect (Old Style) Model SM November 1, 2011 Applicable additional manuals: SM60427 Nozzle

Carter Ground Fueling Underwing Refueling Nozzle Model 64349

AVIATION FUELING CONTROL VALVES

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

Digital Manifold with Digital Hydrant Control

V A L V E S & M E A S U R E M E N T. TOM WHEATLEY Piston Check Valves TOM WHEATLEY

TBH Series True Union Ball Valve Product Guide

Model Maintenance & Repair Manual. 3 x 4 Inch Hydrant Coupler with Pressure Control To Mate Hydrants in Accordance with API Bulletin 1584

The TD Series Tilting Disc Check Valve Sizes from 2 to 72 #125 and #250 ratings available 55 seating angle 40% size increase through seat.

Maintenance Manual 6-INCH INTERNAL VALVE F620 SERIES

Mark 695 Series. Pressure Regulators Mark 695 Piloted Tank Blanketing Regulators. Piloted Tank Blanketing Regulator 3/4"- 1" Optional Features

ORIFICE PLATE flow meters

Deep Well Pump Control Valve

Bottom Loading & Recirculation Adapters

This small footprint makes a BIG impact

C.A.S.E. AIR CARRIER SECTION POLICIES AND PROCEDURES

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Index. Butterfly Valves

Digital III Fueling Vehicle Control System

Solenoid Valve Manifold for use with Digital Pressure Control Coupler

Carter Underwing Refueling Nozzle Model 60427

AWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

SECTION VALVES AND OPERATORS

3 Inch & 4 Inch Fuel Operated Bypass Pressure Control Valves. Models & 64513

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Aeroquip Low Profile Self Sealing Couplings. Series 2000 Series 2001

TABLE OF CONTENT

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

Electronic Control Valves

APCO SURGE RELIEF ANGLE VALVES (SRA)

High Pressure 2-way 2 1/2-6 Globe Valves

Series 769 FireLock NXT Deluge Valve

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

Model Maintenance Manual. SM44646 October Applicable additional manuals:

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves

Pressure reducing valves

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Iron Check Valves Illustrated Index

Electric vehicle auxiliary fuses 500 Vdc, A

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

Specification made simple for selective coordination in a compact size

Backflow Irrigation Control Station BIC-1000

SECTION MISCELLANEOUS VALVES

AMERICAN FLOW CONTROL 3-16 SERIES 2100 RESILIENT SEATED CHECK VALVE

Model Hydrant Coupler with Pressure Control To Mate Hydrants In Accordance With API Bulletin 1584 SM Maintenance & Repair Manual

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Butterfly Valves. watts.com

Non-Valved Unisex Coupling

APCO SLANTING DISC CHECK VALVES

SM64155 Maintenance & Repair Manual

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

Carter Ground Fueling Underwing Refueling Nozzle Model 60427

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

Table of Contents. Choke Principle...4

Maintenance Manual. 4-Inch Internal Valve. F614 Series

HIGH PRESSURE CONTROL VALVES

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

740G Double Disc Check Valve

BERMAD BERMAD BERMAD WW M

AWWA Swing Check Valves

Hart lock industrial grade 50A locking devices

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital)

Series 751 FireLock European Alarm Check Valve Stations

Expanding & Slab Gate Valves

6400 Series Horizontal Loading Valves

SURGEBUSTER! BUILT WITH ADVANCED TECHNOLOGY TO WITHSTAND YOUR TOUGHEST APPLICATIONS. Air Release Air Valves. Air/Vacuum Air Valves

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Swivel Quick Disconnect To Mate Various Carter Brand Nozzles. Model SM Maintenance & Repair Manual

CAST IRON VALVES PRESSURE REDUCING VALVES SERIES

CCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901

Transcription:

Carter Hydrant Pit Valve 4th Edition EI 1584 Model 60554

Eaton s Carter Model 60554 Hydrant Pit Valve is a family of valves that includes lanyard, air or dual air/lanyard operated pilot valves, with available defueling option. 60554 Hydrant Pit valves meet all the requirements of 4th Edition EI 1584, including the breakaway and strength requirements. The basic hydrant pit valve consists of three basic parts, lower valve assembly, upper valve assembly (or API outlet adapter) and a pilot valve. The lower valve assembly contains an isolation valve which will allow the removal and servicing of the upper valve assembly and the pilot valve assembly while the pit valve is still installed. (See service manual SM60554 for proper instructions). The upper valve portion of the 60554 is furnished with a replaceable 4 API outlet adapter on standard configurations and most upper valve options. This minimizes replacement parts and allows for easy replacement of outlet wearing surfaces. Model 60554 Hydrant Pit Valve is designed with soft closing features to minimize the propagation of surge into the upstream piping system during closure of the valve. Features Standard aluminum two-piece upper half standard, replaceable stainless steel 4 API outlet adapter. Stainless uppers with replaceable 4 API outlet adapter optional. Standard inlet flange mates with 4-inch 150 lb. ANSI flange. Non-adjustable closing time is 2-5 seconds. Optional Pilotless Valve reduces maintenance costs. Lanyard, air, or dual air/lanyard operated pilot valves available (for small or large pit applications). Servicing valve provides means to remove the upper valve assembly and pilot valve assembly with the unit still installed. Dual pilot adds true deadman backup to coupler, same as air operated pilot. Hydrant valve is automatically closed at the end of the refueling operation. All seals are field replaceable. Large pressure equalizing valve in the outlet poppet. Model Descriptions There are six basic hydrant pit valve and pilot option combinations to which various modifications may be added by inclusion of option letters as shown in the table below. The six basic combinations are as follows: 60554D - Lanyard operated pilot valve for manual on/off control. Valve allows flow in the fueling direction only. 60554V Air or fuel operated pilot valve for deadman control. Capable of bi-directional flow. 60554X Simple valve connector to be used with air or fuel operated 64230 and/or 64280 Remote Pilot Valve Actuators. Capable of bi-directional flow. 60554Y (Dual Operation) Right Hand Quick Release Lanyard with simple valve connector to be used with air or fuel operated 64230 and/or 64280 Remote Pilot Actuators. Capable of bi-directional flow. 60554Y1 (Dual Operation) Left hand quick release lanyard with simple valve connector to be used with air or fuel operated 64230 and/or 64280 Remote Pilot Actuators. Capable of bi-directional flow. 60554Z (Dual Operation) Air operated pilot valve with Lanyard override for manual on/off control. Capable of Bi-directional flow. Model 64230 pilot valve actuator Model 64280 pilot valve actuator Defueling capability optional with any air or dual air/lanyard operated pilot. Ductile iron main valve body epoxy coated for corrosion protection. Main piston well guided to minimize piston seal wear. 10 or 20-mesh screen options available. 2 HYDRANT PIT VALVE PRODUCT LITERATURE January 2018 www.eaton.com

Installation information It is critical that the mating coupler (shown at right) be connected correctly and the pit lid is able to close completely. The hydrant valve s installation depth depends upon the brand of pit used. The thickness of the pit lid should be checked to be sure that it will clear the hydrant valve before setting the pit. Eaton cannot be responsible for changes in the pits. The dimensions shown are for reference only. Dimensions are shown in inches. Dimensional specifications The drawings below provide envelope dimensions for installation purposes only. They are not intended for inspection purposes. Technical information In compliance with EI 1584 4th Edition. Design Pressure: 275 psi (1900 kpa). Operating Pressure: -1.5 200 psi (-10 1400 kpa). Pressures are in accordance with EI 1584 4th Edition. Closing Time - 2 to 5 seconds. Overshoot - 60.0 gals (225 liters) maximum at 1200 USgpm (4500 l/min.). Pilot valve air or fuel pressure required for models V, X, or Y is 35 psi min. (2.41 bars). Pilot valve air pressure required for model Z is 35 psi min. (2.41 bars). Mates with all 4 EI 1584 style hydrant couplers. Standard Materials - Inlet housing ductile iron; Outlet housing A356-T6 aluminum with stainless steel mating API adapter; trim - stainless steel and aluminum alloy. Weight Basic Hydrant Pit Valve with options (D, V, X, & Y) 57.5 lbs., with option (Z) 58.0 lbs., with option (S) 70 lbs. HYDRANT PIT VALVE PRODUCT LITERATURE January 2018 www.eaton.com 3

Illustrated options 4 HYDRANT PIT VALVE PRODUCT LITERATURE January 2018 www.eaton.com

Ordering data Option letters may be combined with the basic units, except as noted, to customize the valve to fit specific installation requirements. Note basic models referenced on page 2 Model Description section. Option Description A Adds 10-mesh screen between upper and lower halves of the unit. (81557-10) B Adds 20-mesh screen between upper and lower halves of the unit. (81557-20) C Adds six-position product selection (44290) M M1 S Adds Vented Male Disconnect to Option Z connection port. Adds Vented Male Disconnect with 15 fitting to Option V connection port. Changes upper half housing (adapter) to 316 stainless steel. (43214-4) (Special order) T Adds Fusible Plug to connector port Z option. (47326). Example: 60554BYM - Standard unit with dual operated pilot valve, vented male disconnect, and 20-mesh screen. Superseding data Since the late 1960 s, Eaton s Carter product line of hydrant valves have been manufactured in a number of different designs and models. Several of these models are no longer manufactured and spare part support has been discontinued. The list of hydrant valve model numbers (right) provides the superseding data to allow one to specify and procure the latest units of the series. Use this list to obtain the appropriate current model number (60554 or 61654) and then refer to the appropriate table of options for either model 60554 or 61654 hydrant valve to complete the part number. (For Model 61654 options, see brochure TF100-86). Model Number Description 60550 4 x 4 API Adapter with manual butterfly isolation valve at inlet. 60551 4 x 4 API outlet adapter with dual flapper, lanyard operated inlet valve. 60552 Same as 60551 except added interlock to close hydrant should coupler be inadvertently removed. 60553 4 x 4 API outlet adapter with air operated inlet valve utilizing dual externally mounted cylinders. 60554-1 Air operated 60554 type hydrant valve except 6 x 4 with outer housings and poppet material per ASTM A536-72, grade 80-55-06. 60554 SPECIAL/ 60554-2D/ 60554-3D Same as 60554 Series except material for outer housings per ASTM A395. 60555 Aluminum inlet to mate 6" 300 lb. flange x 4" API outlet. In accordance with IP Standard. 61153 6 x 4-300 lb. flange inlet with API outlet adapter. Air operated pilot with defueling capability and 10-mesh screen. Superseded by - Comments No longer supported with spare parts. Replace with appropriate 60554 Hydrant Valve. No longer supported with spare parts. Replace with appropriate 60554 Hydrant Valve. No longer supported with spare parts. Replace with appropriate 60554 Hydrant Valve. No longer supported with spare parts. Replace with appropriate 60554 Hydrant Valve. Spare parts common to standard 60554. For new orders use part number 61654V (Option K no longer offered.). Limited spare parts support continues. Contact Eaton Carter distributor for new order inquiry. Spare parts support continues for all parts except inlet housing. Inlet housing can be replaced with a kit of current ductile iron parts. Spare parts support continues. For new orders use part number 61654AV. (Part number change only). 60554E 4 x 4 hydrant valve with air operated pilot. Spare parts support continues. For new orders use part number 60554V. 60554F 4 x 4 hydrant valve with dual air/lanyard pilot valve. Spare parts support continues. For new orders use part number 60554Z. 60554J 60554Q and 60554R 60554U 4 x 4 hydrant valve with air pilot and defuel capability. 4 x 4 hydrant valve with ductile upper housing and ductile API 4 adapter (option Q) or stainless steel API 4 adapter (option R). 4 x 4 hydrant valve with dual air/lanyard pilot valve. Spare parts support continues. For new orders use option X, Y, Y1, V, or Z combined with 60554 hydrant pit valve. Spare parts support continues. For new orders use option S for full stainless steel upper housing assembly. Spare parts support continues. For new orders use option Y, Y1, or Z combined with 60554 hydrant valve. HYDRANT PIT VALVE PRODUCT LITERATURE January 2018 www.eaton.com 5

Valve operation Figure A valve open Figure B valve closed Figure A reflects a lanyard operated pilot valve shown in the open position. Figure B reflects a lanyard operated pilot in a closed position. The operation of the Hydrant Valve, whether the pilot is lanyard, air, or fuel operated, is identical. The only differences are in the operating mechanism that supplies the pressure to open and close the pilot valve. In the air or fuel operated pilot, the closing lanyard and opening latching mechanisms are replaced with an air or fuel operated piston. The dual air/lanyard operated pilot valve has the same normal air operated pilot valve function with a manual (lanyard) over-ride of the air supply. Servicing valve closed/pilot valve open or closed Closing of the Servicing Valve has the same effect as closing the Pilot Valve. That is, the flow passage from the piston chamber to the downstream side of the piston is blocked. The piston chamber pressure begins to equalize to the inlet pressure (P1) through the check valve. The piston area is greater than the effective seal area, hence the unbalance of forces caused by the equal pressure, plus the spring, will cause the valve to stay closed. Pilot valve open/servicing valve open The open pilot valve allows the continuous passageway from the main piston chamber and from the closing control orifice. The piston chamber is vented through an opening control orifice and the open Servicing valve to a point in the Lower Valve Half. The pressure (P2) at this point is less than the inlet pressure (P1). The piston chamber pressure is also maintained at P2 causing an unbalance of forces on the piston. The inlet pressure force is greater than the combined piston pressure force plus the spring force hence the valve will open to allow flow. This is assuming that the outlet adapter poppet in the Upper Valve Half has been opened by a Coupler. The pilot poppet is maintained in the open position by one of two methods: Lanyard operated pilot - The pilot is opened by the pull of the T handle located on the top of the pilot valve. When it is pulled upward, the spring loaded latch attached to the lanyard pivots to lock the pilot into the open position. Air operated pilot/dual air-lanyard pilot - Air pressure applied to the pilot piston will maintain the pilot in the open position until the pressure has been depleted (by release of deadman or pulling lanyard). Air or fuel operated pilot Pressure applied to the pilot piston will maintain the pilot in the open position until pressure has been depleted (by release of deadman). Pilot valve closed/servicing valve open Pulling the lanyard, or depleting the air or fuel pressure supplied to their respective pilots, will allow the spring loaded pilot poppet to close. This action blocks off the venting of the piston chamber to the lower pressure area downstream. The piston chamber begins to equalize to the inlet pressure (P1) through the check valve. The piston area is greater than the effective seal area; hence the unbalance of forces caused by the equal pressure plus the spring will cause the piston to begin to close. As the piston moves toward the closed position, the piston chamber volume increases and must be filled through the two series orifices. The primary orifice is considerably larger than the secondary (slot). During the initial and majority of the travel of the piston, the primary orifice is fully exposed to the inlet pressure; hence the rate of closure is controlled by this orifice. When the piston moves far enough closed to cover the primary orifice, the secondary (smaller) orifice begins to control the closure rate. Hence the valve begins to close relatively rapidly and then slows down as it nears its closed position. The relative size and locations of these two orifices allows the valve to close to provide a minimum of overshoot and yet limit the surge pressure shock, on closing, and still maintain a closure rate in accordance with applicable international specifications. On defueling options the pilot valve remains closed so long as the pilot is not actuated manually or by deadman supplied pressure. The lanyard operation is only for emergency situations where the air supply is not released by the deadman valve. 6 HYDRANT PIT VALVE PRODUCT LITERATURE January 2018 www.eaton.com

Technical data Flow characteristics The charts presented below depicts typical pressure drop versus flow characteristics of the 60554 Series Hydrant Pit Valves. (Pilot option D, X, Y, Y1, V, or Z will not alter the pressure drop characteristics of the 60554). 55 50 45 40 35 Curve 5 Pressure Drop, PSI 30 25 20 Curve 2 Curve 3 15 10 5 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Flow, GPM Curve 1 Curve 4 1300 1400 1500 2000 Curve 1 Model 60554BD - 20-mesh screen & 61525. Curve 2 Model 60554X, 20-mesh screen & 61525 - fueling direction. Curve 3 Model 60554X, 20-mesh Screen & 61525 - defueling direction. Curve 4 Model 60554D no screen and Model 61525 Coupler Curve 5 60554D - no screen & 60600K. Technical data 60554ST1 Hydrant outlet wear gauge Wear gauge is available to check for wear on the 4 API adapter interface of Carter hydrant valves made in accordance with EI 1584 4th Edition. Refer to the appropriate service manual for instructions. HYDRANT PIT VALVE PRODUCT LITERATURE January 2018 www.eaton.com 7

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Electrical Sector Canadian Operations 5050 Mainway Burlington, ON L7L 5Z1 Canada EatonCanada.ca 2018 Eaton All Rights Reserved Printed in USA January 2018 Eaton is a registered trademark. All other trademarks are property of their respective owners. Follow us on social media to get the latest product and support information.