INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR

Similar documents
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE REGULATOR

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER DEHYDRATION ASSEMBLY

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE CONDITIONING HEATED SYSTEM

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INLOOP CRUDE OIL SAMPLER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER FIXED INSERTION

Welker Gas Sampler Model MPS-2

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER TELESCOPING INSERTION

Welker Heated Instrument Regulator

Installation, Operation, and Maintenance Manual

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER WITH AI CONTROL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RECYCLE TIMER

Installation, Operation, and Maintenance Manual

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Installation, Operation, and Maintenance Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW CRUDE OIL SAMPLER WITH AI CONTROL

Operation, Model MPS-2DA. Installation, responsibility

Welker Automatic Insertion Diffusing Probe Model AIP-3DP

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC

Welker Jet Insert Model Control Valve

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TIMER/CONTROLLER

Welker Jet Top Entry Control Valve

INSTRUCTION AND MAINTENANCE MANUAL GFH45 PRESSURE REGULATOR

Calibration and Switching Module. User s Manual. A Swagelok Pre-Engineered. Subsystem. Pre-engineered subsystems available in weeks, not months.

TITAN FLOW CONTROL, INC.

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA

For additional information, please visit our website at SENSOR SPECIFICATIONS

ROOTS Meters Series B3 Meter Models 8C175-56M175

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

105 Commerce Way Westminster, SC Tel: (864) Fax: (864)

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

Inverted High Pressure Fluid Filters

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

Type EZR Relief Valve or Backpressure Regulator

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Y690A Series Pressure Reducing Regulators

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

Cylinder and Valve: AirHawk II Air Mask

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

Series 820 AWWA Butterfly Valves

INSTALLATION/OPERATION/MAINTENANCE MANUAL for the FlowMax REGULATOR

To ensure proper installation, digital pictures with contact information to before startup.

Type EZR Relief Valve or Backpressure Regulator

Installation, Operation and Maintenance Manual for Flame Check

Anderson Greenwood Series 800 POSRV Installation and Maintenance Instructions

TITAN FLOW CONTROL, INC.

Baumann Sanitary Diaphragm Angle and Inline Control Valve

DR Series Radial Diaphragm Valves

Installation, Operation, & Maintenance Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FIXED ODORANT MONITOR

Y690A Series Pressure Reducing Regulators

Fisher D2T FloPro Control Valve

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions

Swing-Flex Check Valve

INSTALLATION INSTRUCTIONS 3-POSITION GATE VALVES SIZES Read All Instructions Prior To Installation

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

Type MR108 Direct-Operated Backpressure Regulator

Automatic (Air Release) Air Valve

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

Typical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application

Rosemount 402 and 402VP

Pilot-Operated Regulators

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Baumann Series Flexsleev Control Valve Instructions

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Check List for Optimal Filter Performance

DO NOT INSTALL, OPERATE, OR MAINTAIN AN ATI PRODUCT UNLESS TRAINED AND QUALIFIED IN PRODUCT AND ACCESSORY INSTALLATION, OPERATION AND MAINTENANCE.

161 Series Pilots for Pilot-Operated Pressure Reducing Regulators

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

VWR Zero Air Generator

Bypass / Filter Feeders Operations & Maintenance Manual

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Model DFR 026 Rotary Actuator

Operation & Service Manual

Fisher RSS Lined Globe Valve

Operating & Maintenance Manual For Steam Conditioning Valve

Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator

Fisher RSS Lined Globe Valve

Model INTERNAL/BOTTOM LOADING VALVES SM Maintenance & Repair Manual. July Applicable addition manuals: None

EP-2 Si Three-Piston Pump

Maintenance. Part A, Section 5. This section covers the following unit configurations.

A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

MODEL 1100 TURBINE FLOW METER

Temperature Sensor Series

Transcription:

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR MODEL LE-2SSKO DRAWING NUMBERS AD691BG AD691BGSYS.3 AD691BGSYS.4 AD691CC AD691CD AD691CG AD691CI MANUAL NUMBER IOM-069 REVISION Rev. E, 05/26/2015

TABLE OF CONTENTS SAFETY 3 1. PRODUCT INFORMATION 4 1.1 Introduction 4 1.2 Product Description 4 1.3 Specifications 5 1.4 System Diagram 6 2. INSTALLATION & OPERATION 7 2.1 Before You Begin 7 2.2 Installation & Operation 7 3. MAINTENANCE 9 3.1 Before You Begin 9 3.2 Maintenance 9 APPENDIX 12 Referenced or Attached Welker IOMs 12 Referenced or Attached Buy-Out IOMs 12 Referenced or Attached Drawings 12 ADDENDA 13 A: LE-2SSKO With Double Block and Bleed Valves 13 B: LE-2SSKO With ALS-1 17 C: LE-2SSKO With Regulator(s) and Filter 21 D: x-wave Probe Tip 26 Welker, Welker Jet, and WelkerScope are Registered Trademarks owned by Welker, Inc. 2 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

SAFETY IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS Notes emphasize information and/or provide additional information to assist the user. Caution messages appear before procedures that, if not observed, could result in damage to equipment. Warning messages appear before procedures that, if not observed, could result in personal injury. This manual is intended to be used as a basic installation and operation guide for the Welker Probe Mounted Liquid Eliminator, LE-2SSKO. For comprehensive instructions, please refer to the IOM Manuals for each individual component. A list of relevant component IOM Manuals is provided in the Appendix section of this manual. The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and maintenance of the Welker equipment described in this manual. Correct installation and operation, however, are the responsibility of the end user. Welker reserves the right to make changes to this and all products in order to improve performance and reliability. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Save these instructions for local inspector s use. IMPORTANT Observe all governing codes and ordinances. Note to Installer Leave these instructions with the end user. Note to End User Keep these instructions for future reference. Installation of this Probe Mounted Liquid Eliminator is of a mechanical nature. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the warranty. If you received a damaged Probe Mounted Liquid Eliminator, please contact a Welker representative immediately. Phone: 281.491.2331 Address: 13839 West Bellfort Street Sugar Land, TX 77498 3 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

SECTION 1: PRODUCT INFORMATION 1.1 Introduction We appreciate your business and your choice of Welker products. The installation, operation, and maintenance liability for this product becomes that of the purchaser at the time of receipt. Reading the applicable Installation, Operation, and Maintenance (IOM) Manual prior to installation and operation of this equipment is required for a full understanding of its application and performance prior to use.* If you have any questions, please call Welker at 1-281-491-2331. *The following procedures have been written for use with standard Welker parts and equipment. Assemblies that have been modified may have additional requirements and specifications that are not listed in this manual. 1.2 Product Description The Welker LE-2SSKO Probe Mounted Liquid Eliminator is designed to remove entrained liquids, condensed hydrocarbons, glycol, and amines from gas samples, ensuring the collection of representative samples and protecting analyzers from damage and contamination. Pipeline product enters the LE-2SSKO through the probe. The gas stream passes through the LE-2SSKO to the sample outlet, but any liquids present are separated from the sample stream by centrifugal flow, a membrane, and a screen and then returned to the pipeline through the stinger. Optional features provide additional protection from entrained liquids. The Welker x-wave Probe Tip and Welker ALS-1 Analyzer Liquid Shutoff are designed with a floating ball that will seal if liquid tries to pass through. The x-wave Probe Tip acts as a first defense against liquids, allowing only gas to enter through the probe of the LE-2SSKO. The ALS-1 acts as a final defense against liquids, shutting off product flow to the analyzer in the presence of liquids. Welker may custom design the LE-2SSKO to suit the particular application and specifications of each customer. 4 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

1.3 Specifications The specifications listed in this section are generalized for this equipment. Welker can modify the equipment according to your company's needs. However, please note that the specifications may vary depending on the customization of your product. Products Sampled Materials of Construction Maximum Allowable Operating Pressure Outlet Connection Pipeline Connection Filter Media Options Table 1: LE-2SSKO Specifications Gases Compatible With the Materials of Construction 304 Stainless Steel, 316/316L Stainless Steel, PTFE, Viton Others Available 1440 psig @ -20 F to 100 F (99 barg @ -28 C to 37 C) Others Available 1/4" NPT 1/2" NPT (Standard) 3/4" NPT 1/2" NPT 3/4" NPT 1" NPT 2" 600 ANSI RF Others Available 25 Micron Copolymer Membrane 304 Stainless Steel Mesh Screen Double Block and Bleed Valves Insulation Blanket Integrated Regulators, Relief Valves, and Filter Integrated Welker ALS-1 Analyzer Liquid Shutoff x-wave Probe Tip 5 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

1.4 System Diagram Figure 1: LE-2SSKO Diagram 6 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

SECTION 2: INSTALLATION & OPERATION 2.1 Before You Begin After unpacking the unit, check the equipment for compliance and any damage that may have occurred during shipment. Immediately contact a Welker representative if you received damaged equipment. When sealing fittings with PTFE tape, refer to the proper sealing instructions for the brand used. 1. Welker recommends that the unit be installed in the top of the pipe and inserted into the center one-third (1/3) of the pipeline in a location where the product is well-mixed and will yield an accurate and representative sample. 2. The sample probe should be located in the least turbulent area of the flowing stream available (i.e., not in a header or non-flowing area and away from obstructions, elbows, and partially closed valves). 2.2 Installation & Operation The pipeline must be depressurized prior to installing and removing the unit. If the LE-2SSKO is equipped with double block and bleed valves, refer to Addendum A, LE-2SSKO With Double Block and Bleed Valves, for instructions on correctly installing the unit. If the LE-2SSKO is equipped with optional regulator(s) and filter, refer to Addendum C, LE-2SSKO With Regulator(s) and Filter, for instructions on correctly installing the unit. If the LE-2SSKO is equipped with the optional x-wave Probe Tip, the x-wave Probe Tip may seal dry and prevent product from reaching the outlet if the pipeline flow is greater than 400 cc/minute. 1. Ensure that inlet (P 1) valve A and return (P 2) valve B are closed (Figure 1). 2. Ensure that all cap screws on the top cap are tightened (Figure 1). 3. Ensure that the pipeline is depressurized. 4. As necessary, wrap the threads of the threaded pipeline connection with PTFE tape. 7 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

5. Install the LE-2SSKO to the pipeline so that the stinger is downstream of the direction of product flow (Figure 2). As necessary, refer to the flow direction stamped on the top cap to determine correct orientation before installing the LE-2SSKO to the pipeline. Figure 2: Correct LE-2SSKO Installation 6. Using customer-supplied tubing, connect from the product outlet to the customer s downstream instrument(s) (e.g., a regulator assembly connected to an analyzer) (Figure 1). 7. Pressurize the pipeline. 8. Open inlet (P 1) valve A and return (P 2) valve B (Figure 1). Check for leaks at the pipeline connection and repair as necessary. 9. The LE-2SSKO is now operational. 10. If liquids are present at the product outlet, maintenance is required. See Section 3.2, Maintenance, for instructions on performing maintenance on the LE-2SSKO. 11. If the LE-2SSKO is equipped with the optional ALS-1 Analyzer Liquid Shutoff, observe the ball in the ALS-1. If the ball rises and shuts off the ALS-1, liquid has entered the system and maintenance is required. Refer to Addendum B, LE-2SSKO With ALS-1, for instructions on maintaining the LE-2SSKO with ALS-1. 12. If the LE-2SSKO is equipped with the optional x-wave Probe Tip, visually verify that the gas stream can reach the product outlet. If product is not observed at the outlet, the force of the pipeline flow may have caused the ball to lock, requiring maintenance on the x-wave Probe Tip. Refer to Addendum D, x-wave Probe Tip, for instructions on maintaining the x-wave Probe Tip. 8 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

SECTION 3: MAINTENANCE 3.1 Before You Begin 1. Welker recommends that the unit have standard maintenance every six (6) months under normal operating conditions and any time liquid is present in the copolymer flat membrane or at the product outlet. In cases of severe service, dirty conditions, excessive usage, or other unique applications that may lead to excess wear on the unit, a more frequent maintenance schedule may be appropriate. 2. Prior to maintenance or disassembly of the unit, it is advisable to have a repair kit available for repairs of the system in case of unexpected wear or faulty seals. New seals supplied in spare parts kits should be lightly lubricated before being installed. This eases the installation of the seals and reduces the risk of damage when positioning them on parts. Welker recommends non-hydrocarbon-based lubricants, such as Krytox, for use with all sample cylinder seals and silicone-based lubricants, such as Molykote 111, for use with seals not exposed to the sample product. Wipe excess lubricant from the seals, as it may adversely affect analytical instrument results. After the seals are installed, the outer diameter of shafts and inner diameter of cylinders may be lubricated to allow smooth transition of parts. 3. All maintenance and cleaning of the unit should be performed on a smooth, clean surface. 3.2 Maintenance If maintenance on the valves, probe, stinger, or optional x-wave Probe Tip is required, the LE-2SSKO must be isolated from pipeline pressure and removed from the pipeline before maintenance can be safely performed. Prior to performing maintenance, the LE-2SSKO must be isolated from pipeline pressure. However, the LE-2SSKO does NOT need to be removed from the pipeline to perform standard maintenance. If the LE-2SSKO is equipped with double block and bleed valves, refer to Addendum A, LE-2SSKO With Double Block and Bleed Valves, for instructions on removing and performing maintenance on the unit. If the LE-2SSKO is equipped with the ALS-1 Analyzer Liquid Shutoff, refer to Addendum B, LE-2SSKO With ALS-1, for instructions on removing and performing maintenance on the unit. If the LE-2SSKO is equipped with optional regulator(s) and filter, refer to Addendum C, LE-2SSKO With Regulator(s) and Filter, for instructions on performing maintenance on the unit. 9 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

If the LE-2SSKO is equipped with the optional x-wave Probe Tip, refer to Addendum D, x-wave Probe Tip, for instructions on performing maintenance on the x-wave. 1. Close inlet (P 1) valve A and return (P 2) valve B. 2. Disconnect all tubing from the LE-2SSKO. Figure 3: Maintenance Diagram 3. Loosen the cap screws, and then remove the top cap. 4. Remove the screen. 5. Remove the O-ring from the body. 6. Remove the copolymer flat membrane. 7. Using a solvent, clean the screen and inside of the LE-2SSKO body. Welker recommends using a solvent that does not leave a film when dry and will not adversely affect analytical instrument results, such as rubbing alcohol. 10 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

8. Replace the copolymer flat membrane. 9. Replace the O-ring. 10. Return the cleaned screen to the top of the copolymer flat membrane. 11. Align the top cap with the body, and then reinstall the cap screws following a cross-bolting sequence (Figure 4). Figure 4: Cross-Bolting Sequence 12. As necessary, tighten all cap screws to the correct torque (Table 2). Table 2: Torque Specifications for Cap Screws Cap Screw Diameter & Thirds per Inch Inch-Pounds (in lb) Newton Meter (N m) 1/4-20 78 8 3/8-16 247 27 13. If maintenance on the valves is necessary, remove the LE-2SSKO from the pipeline, and then refer to the Installation, Operation, and Maintenance (IOM) Manual for the Welker NV-1 and NV-2 Instrument Valves for instructions on maintaining the valves. 14. The LE-2SSKO is now ready to be reinstalled to the pipeline and/or returned to operation. See Section 2.2, Installation & Operation, for instructions on installing the unit to the pipeline and/or returning the unit to operation. During reinstallation check valves for leaks and repair as necessary. 11 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

APPENDIX Referenced or Attached Documents Welker Installation, Operation, and Maintenance (IOM) Manuals suggested for use with this unit: IOM-025: Welker IR-1, IR-2, IR-4, and IR-6 Instrument Regulators IOM-033: Welker RV-1, RV-2, RV-2CP, and RV-3 Relief Valves IOM-077: Welker ALS-1, ALS-1HP, ALS-2, ALS-3, and ALS-4HP Analyzer Liquid Shutoff IOM-105: Welker NV-1 and NV-2 Instrument Valves Other Installation, Operation, and Maintenance (IOM) Manuals suggested for use with this unit: a1-cbiss Avenger 91 Particulate & Coalescing Filter (Welker IOM-V169) Cashco, Inc. Model P1 Single Stage Pressure Reducing Regulator (Welker IOM-V168) Swagelok R Series Proportional Relief Valves (Welker IOM-V015) Addenda available for this Installation, Operation, and Maintenance (IOM) Manual: Addendum A: LE-2SSKO With Double Block and Bleed Valves Addendum B: LE-2SSKO With ALS-1 Addendum C: LE-2SSKO With Regulator(s) and Filter Addendum D: x-wave Probe Tip Welker drawings and schematics suggested for use with this unit: Assembly Drawing: AD691BG (Standard) Assembly Drawing: AD691BGSYS.3 (With Single Regulator and Filter) Assembly Drawing: AD691BGSYS.4 (With Dual Regulators and Filter) Assembly Drawing: AD691CC (With ALS-1) Assembly Drawing: AD691CD (With Double Block and Bleed Valves) Assembly Drawing: AD691CG (With x-wave Probe Tip) Assembly Drawing: AD691CI (x-wave Kit) 12 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

ADDENDUM A: LE-2SSKO WITH DOUBLE BLOCK AND BLEED VALVES A1.1 System Diagram Figure A1: LE-2SSKO With Double Block and Bleed Valves 13 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

1.2 Installation & Operation The pipeline must be depressurized prior to installing and removing the unit. 1. Ensure that all valves are closed (Figure A1). 2. Ensure that all cap screws on the top cap are tightened (Figure A1). 3. Ensure that the pipeline is depressurized. 4. As necessary, wrap the threads of the threaded pipeline connection with PTFE tape. 5. Install the LE-2SSKO to the pipeline so that the stinger is downstream of the direction of product flow. As necessary, refer to the flow direction stamped on the top cap to determine correct orientation before installing the LE-2SSKO to the pipeline (Figure A1). 6. Using customer-supplied tubing, connect from the product outlet to the customer s downstream instrument(s) (e.g., a regulator assembly connected to an analyzer) (Figure A1). 7. Pressurize the pipeline. 8. Open inlet (P 1) valves A1 and A2 and return (P 2) valves B1 and B2 (Figure A1). Check for leaks at the pipeline connection and repair as necessary. 9. The LE-2SSKO is now operational. 10. If liquids are present at the product outlet, maintenance is required. See Section A1.3, Maintenance, for instructions on performing maintenance on the LE-2SSKO with Double Block and Bleed Valves. A1.3 Maintenance If maintenance on the valves, probe, or stinger is required, the LE-2SSKO must be isolated from pipeline pressure and removed from the pipeline before maintenance can be safely performed. Prior to performing maintenance, the LE-2SSKO must be isolated from pipeline pressure. However, the LE-2SSKO does NOT need to be removed from the pipeline to perform standard maintenance. 1. Close inlet (P 1) valve A1 and return (P 2) valve B1 (Figure A1). 2. Open both bleed valves to relieve pressure in the LE-2SSKO body (Figure A1). 3. Close both bleed valves, and then close inlet (P 1) valve A2 and return (P 2) valve B2 (Figure A1). 4. Disconnect all tubing from the LE-2SSKO. 14 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

Figure A2: Maintenance Diagram 5. 6. 7. 8. 9. Loosen the cap screws, and then remove the top cap. Remove the screen. Remove the O-ring from the body. Remove the copolymer flat membrane. Using a solvent, clean the screen and inside of the LE-2SSKO body. Welker recommends using a solvent that does not leave a film when dry and will not adversely affect analytical instrument results, such as rubbing alcohol. 10. 11. 12. 15 Replace the copolymer flat membrane. Replace the O-ring. Return the cleaned screen to the top of the copolymer flat membrane. IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

13. Align the top cap with the body, and then reinstall the cap screws following a cross-bolting sequence (Figure A3). Figure A3: Cross-Bolting Sequence 14. As necessary, tighten all cap screws to the correct torque (Table A1). Table A1: Torque Specifications for Cap Screws Cap Screw Diameter & Thirds per Inch Inch-Pounds (in lb) Newton Meter (N m) 1/4-20 78 8 3/8-16 247 27 15. If maintenance on the valves is necessary, remove the LE-2SSKO from the pipeline, and then refer to the Installation, Operation, and Maintenance (IOM) Manual for the Welker NV-1 and NV-2 Instrument Valves for instructions on maintaining the valves. 16. The LE-2SSKO is now ready to be reinstalled to the pipeline and/or returned to operation. See Section A1.2, Installation & Operation, for instructions on installing the unit to the pipeline and/or returning the unit to operation. During reinstallation check valves for leaks and repair as necessary. 16 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

ADDENDUM B: LE-2SSKO WITH ALS-1 B1.1 Specifications The specifications listed in this section are generalized for this equipment. Welker can modify the equipment according to your company's needs. However, please note that the specifications may vary depending on the customization of your product. Table B1: LE-2SSKO With ALS-1 Specifications Materials of Construction 316/316L Stainless Steel, Aluminum, Glass, LEXAN, PTFE, Teflon, Viton Maximum Allowable Operating Pressure 1000 psig @ -20 F to 120 F (68 barg @ -28 C to 48 C) B1.2 System Diagram Figure B1: LE-2SSKO With ALS-1 17 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

B1.3 Maintenance If maintenance on the valves, probe, or stinger is required, the LE-2SSKO must be isolated from pipeline pressure and removed from the pipeline before maintenance can be safely performed. Prior to performing maintenance, the LE-2SSKO must be isolated from pipeline pressure. However, the LE-2SSKO does NOT need to be removed from the pipeline to perform standard maintenance. 1. 2. Close inlet (P1) valve A and return (P2) valve B (Figure B1). Disconnect all tubing from the LE-2SSKO. ALS-1 Figure B2: ALS-1 Maintenance 3. 4. 5. Loosen the cap screws, and then remove the ALS-1 from the LE-2SSKO. Unscrew the cap from the ALS-1. Carefully remove the seat, taking care not to scratch the glass, and then replace the O-rings on the seat. DO NOT lubricate the O-ring the ball seals on (Figure B2, #10). 18 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

6. 7. 8. 9. 10. 11. 12. 13. Remove the glass. Remove the guide from the body, and then replace the O-rings on the body. Inspect the ball for scratches or wear. Replace as necessary. Return the ball to the guide. Install the guide to the body. Carefully install the glass over the guide. Carefully insert the seat into the glass, taking care not to scratch the glass. Return the cap to the ALS-1 and hand-tighten. When reassembling the ALS-1, HAND-TIGHTEN ONLY. Liquid Eliminator Figure B3: LE-2SSKO Maintenance 14. 15. 16. 17. Remove the screen. Remove the O-ring from the LE-2SSKO body. Remove the copolymer flat membrane. Using a solvent, clean the screen and inside of the LE-2SSKO body. Welker recommends using a solvent that does not leave a film when dry and will not adversely affect analytical instrument results, such as rubbing alcohol. 18. 19. 20. 19 Replace the copolymer flat membrane. Replace the O-ring. Return the cleaned screen to the top of the copolymer flat membrane. IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

Reassembly 21. Align the ALS-1 with the LE-2SSKO body, and then reinstall the cap screws following a cross-bolting sequence (Figure B4). Figure B4: Cross-Bolting Sequence 22. As necessary, tighten all cap screws to the correct torque (Table B2). Table B2: Torque Specifications for Cap Screws Cap Screw Diameter & Thirds per Inch Inch-Pounds (in lb) Newton Meter (N m) 1/4-20 78 8 3/8-16 247 27 23. If maintenance on the valves is necessary, remove the LE-2SSKO from the pipeline, and then refer to the Installation, Operation, and Maintenance (IOM) Manual for the Welker NV-1 and NV-2 Instrument Valves for instructions on maintaining the valves. 24. The LE-2SSKO is now ready to be reinstalled to the pipeline and/or returned to operation. Refer to Section 2.2, Installation & Operation, in the Installation, Operation, and Maintenance (IOM) Manual for the LE-2SSKO for instructions on installing the unit to the pipeline and/or returning the unit to operation. During reinstallation check valves for leaks and repair as necessary. 20 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

ADDENDUM C: LE-2SSKO WITH REGULATOR(S) AND FILTER C1.1 System Diagram Figure C1: LE-2SSKO With Dual Regulators and Filter 21 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

C1.2 Installation & Operation The pipeline must be depressurized prior to installing and removing the unit. 1. Ensure that all valves are closed (Figure C1). 2. Ensure that all cap screws on the top cap are tightened (Figure C1). 3. Ensure that the pipeline is depressurized. 4. As necessary, wrap the threads of the threaded pipeline connection with PTFE tape. 5. Install the LE-2SSKO to the pipeline so that the stinger is downstream of the direction of product flow (Figure C2). As necessary, refer to the flow direction stamped on the top cap to determine correct orientation before installing the LE-2SSKO to the pipeline. Figure C2: Correct LE-2SSKO Installation 6. Using customer-supplied tubing, connect from the product outlet to the customer s downstream instrument(s) (e.g., a regulator assembly connected to an analyzer) (Figure C1). 7. To prevent over-pressurizing the downstream instrument(s), back the instrument regulator(s) off completely before pressurizing the pipeline. 8. Pressurize the pipeline. 9. Open inlet (P 1) valve A, return (P 2) valve B, and outlet valve C (Figure C1). Check for leaks at the pipeline connection and repair as necessary. 10. If the LE-2SSKO is equipped with one (1) instrument regulator, set the regulator. Refer to the Installation, Operation, and Maintenance (IOM) Manual for the appropriate instrument regulator for instructions on setting the regulator. Proceed to step 13. 22 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

11. If the LE-2SSKO is equipped with two (2) instrument regulators, set the first stage regulator. Refer to the Installation, Operation, and Maintenance (IOM) Manual for the appropriate instrument regulator for instructions on setting the regulator. The first stage regulator should be set to half the desired outlet pressure. This pressure will vary by application. 12. If the LE-2SSKO is equipped with two (2) instrument regulators, set the second stage regulator. Refer to the Installation, Operation, and Maintenance (IOM) Manual for the appropriate instrument regulator for instructions on setting the regulator. The second stage regulator should be set to the desired outlet pressure. This pressure will vary by application. 13. Set the relief valve above the set outlet pressure. Refer to the Installation, Operation, and Maintenance (IOM) Manual for the relief valve for instructions on setting the relief valve. 14. The LE-2SSKO is now operational. 15. If liquids are present at the product outlet, maintenance is required. See Section C1.3, Maintenance, for instructions on performing maintenance on the LE-2SSKO. C1.3 Maintenance If maintenance on the valves, probe, stinger, or optional x-wave Probe Tip is required, the LE-2SSKO must be isolated from pipeline pressure and removed from the pipeline before maintenance can be safely performed. Prior to performing maintenance, the LE-2SSKO must be isolated from pipeline pressure. However, the LE-2SSKO does NOT need to be removed from the pipeline to perform standard maintenance. 1. Determine how quickly free liquids accumulate in the filter by frequently opening drain valve D (Figure C1). Routinely open drain valve D to allow moisture to drain from the filter. 2. Close all valves. 3. Disconnect all tubing from the LE-2SSKO. 4. Disconnect the instrument regulator(s) and filter assembly from the LE-2SSKO. 23 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

Figure C3: Maintenance Diagram 5. Loosen the cap screws, and then remove the top cap. 6. Remove the screen. 7. Remove the O-ring from the body. 8. Remove the copolymer flat membrane. 9. Using a solvent, clean the screen and inside of the LE-2SSKO body. Welker recommends using a solvent that does not leave a film when dry and will not adversely affect analytical instrument results, such as rubbing alcohol. 10. Replace the copolymer flat membrane. 11. Replace the O-ring. 12. Return the cleaned screen to the top of the copolymer flat membrane. 24 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

13. Align the top cap with the body, and then reinstall the cap screws following a cross-bolting sequence (Figure C4). Figure C4: Cross-Bolting Sequence 14. As necessary, tighten all cap screws to the correct torque (Table C1). Table C1: Torque Specifications for Cap Screws Cap Screw Diameter & Thirds per Inch Inch-Pounds (in lb) Newton Meter (N m) 1/4-20 78 8 3/8-16 247 27 15. To perform maintenance on the instrument regulator(s), refer to the appropriate Installation, Operation, and Maintenance (IOM) Manual for instructions on maintaining the regulator(s). 16. To perform maintenance on the filter, refer to the appropriate Installation, Operation, and Maintenance (IOM) Manual for instructions on maintaining the filter. 17. If maintenance on the valves is necessary, remove the LE-2SSKO from the pipeline, and then refer to the Installation, Operation, and Maintenance (IOM) Manual for the Welker NV-1 and NV-2 Instrument Valves for instructions on maintaining the valves. 18. Reconnect the instrument regulator(s) and filter assembly to the LE-2SSKO. 19. The LE-2SSKO is now ready to be reinstalled to the pipeline and/or returned to operation. See Section C2.2, Installation & Operation, for instructions on installing the unit to the pipeline and/or returning the unit to operation. During reinstallation check valves for leaks and repair as necessary. 25 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

ADDENDUM D: x-wave PROBE TIP D1.1 Product Description The Welker x-wave Probe Tip is designed to prevent failure of the LE-2SSKO caused by slugs of liquid in the pipeline and shortterm flooding by reducing the volume of liquid that enters the probe. When the liquid level in the pipeline rises, the liquid pushes the ball inside the x-wave Probe Tip up, creating a seal and preventing the LE-2SSKO from being flooded by the liquid. When the liquid level falls, the stinger relieves pressure in the LE- 2SSKO, breaking the seal of the ball and allowing product flow through the probe. The x-wave Probe Tip will not prevent failure of the LE-2SSKO caused by long-term flooding. 1.2 Specifications The specifications listed in this section are generalized for this equipment. Welker can modify the equipment according to your company's needs. However, please note that the specifications may vary depending on the customization of your product. Materials of Construction Table D1: x-wave Probe Tip Specifications 316 Stainless Steel, 316/316L Stainless Steel, Polypropylene, PTFE, Viton Others Available D1.3 System Diagrams Figure D1: LE-2SSKO With x-wave Probe Tip 26 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

Figure D2: x-wave Probe Tip Models D1.4 Maintenance If maintenance on the valves, probe, stinger, or optional x-wave Probe Tip is required, the LE-2SSKO must be isolated from pipeline pressure and removed from the pipeline before maintenance can be safely performed. 1. Close inlet (P 1) valve A and return (P 2) valve B. 2. Disconnect all tubing from the LE-2SSKO. 3. Remove the LE-2SSKO from the pipeline. 27 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

Figure D2: x-wave Probe Tip Maintenance Diagram 4. Cut the lock wire on the x-wave Probe Tip. 5. Unscrew the body from the nut, taking care not to misplace the ball, which will be removed with the body. 6. Replace the O-ring on the body. 7. Screw the body into the nut. 8. Holding the body steady, tighten the nut using a wrench. 9. Connect a lock wire from the nut to the body. If a replacement lock wire is not available, ensure that the x-wave Probe Tip is securely tightened so that it can withstand the pressure of the flowing stream. 10. To continue maintenance on the LE-2SSKO, refer to Section 3.2, Maintenance, in the Installation, Operation, and Maintenance (IOM) Manual for the LE-2SSKO for instructions on maintaining the LE-2SSKO. 11. To install the LE-2SSKO with optional x-wave Probe Tip after maintenance is complete, refer to Section 2.2, Installation & Operation, in the Installation, Operation, and Maintenance (IOM) Manual for the LE-2SSKO for instructions on installing the unit to the pipeline. 28 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331

NOTES 13839 West Bellfort Street Sugar Land, TX 77498 Phone: 281.491.2331 welker.com 29 IOM-069 MODEL: LE-2SSKO REV: E 13839 West Bellfort Street Sugar Land, TX 77498 welker.com Service Department: 281.491.2331