E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Similar documents
A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

E2EZ-X2D1-N E2EZ-X2D2-N

Inductive Proximity Sensor E2Q2. Ordering Information. Limit Switch Style Proximity Sensor with 5-Position Sensing Head

Inductive Proximity Sensor

Inductive Proximity Sensor

Inductive Proximity Sensor

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

E2E/E2EQ NEXT Series. Proximity Sensor. Long-distance Detection Prevents Unexpected Facility Stoppages. E2E/E2EQ NEXT Series Model Number Legend

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Inductive Proximity Sensor

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Inductive Proximity Sensor

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Cylindrical Proximity Sensor

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Model Pressure range ON/OFF output Linear output

Transistor Remote Modules

Inductive Proximity Sensor

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Inductive Proximity Sensor

Sensing & Safety GENERAL CATALOGUE 2004/2005

Cylindrical Inductive Proximity Sensor GX-M SERIES

Digital display Pressure range ON/OFF output Linear output Model

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

Proximity Sensors E-1. Standard E2E/E2EG E-2 Antispatter E2EQ E-32 Chemical Resistance E2FQ E-40. Cylindrical

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Model Pressure range ON/OFF output Linear output

Model Number Structure

Cylindrical type proximity sensor

F3S-TGR-KM15/-KM16/-KH16

F3S-TGR-KHL1/-KHL3/-KHL3R

Differential Pressure Sensor

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

E2EM-X4X1 2M * E2EM-X4X2 2M Shielded E2EM-X8X1 2M * E2EM-X8X2 2M. M30 15 mm E2EM-X15C1 2M E2EM-X15C2 2M. M18 16 mm E2EM-X16MX1 2M E2EM-X16MX2 2M

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

Digital display Pressure range ON/OFF output Linear output Model

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Analog Output Terminal

Analog Input Terminal

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

E3ZM-C. Photoelectric Sensor for the Automotive and Machine Tool Industries. Features

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Cylindrical photoelectric sensors in M18 plastic or brass housings. Performance and portfolio variety. Metal *1 90 Optics AC power supply *2

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

Small Limit Switch D4V

DC2-Wire Unshielded Cylindrical Proximity Switches

Small-diameter Proximity Sensor

Inductive Proximity Sensor

SG-B1 SERIES / SG-A1 SERIES

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

Model Number Structure

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Rectangular-shaped Inductive Proximity Sensor.

Model Number Structure

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C.

Switching Power Supply

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

AC/DC2-wire Type Cylindrical Proximity Switches

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Clicks for Three Easily Discernable Positions

Not affected by drops, bubbles or froth

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

SYSMAC Transistor Remote Module

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Safety Interlock Switches

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

FL7MSeries. DC2-Wire Regular Cylindrical Proximity Sensors

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Environment-resistant Series. Oil-resistant Components. Let Us Help You. Eliminate Production Line Stoppages. No Cutting Oil Ingress by Any Path

HL (AZH) LIMIT SWITCHES

Transcription:

Rectangular Freely Change the Sensing Direction Change between any of five sensing directions: front or 9 up, down, left, or right. Four indicators show the operating status of the from many directions. Refer to Safety Precautions on page 4. For the most recent information on models that have been certified for safety standards, refer to your OMR website. Ordering Information s [Refer to Dimensions on page 6] DC Models Shielded/ Unshielded Sensing distance Connection method Operation mode NPN output Model PNP output Shielded mm -NE3-H -NF3-H Unshielded mm Terminal block -NME3-H -NMF3-H Accessories (Sold Separately) Recommended Cable Gland (ST Type) (Manufactured by LAPP) Purchase a cable gland to maintain a water-resistant structure. Product number Color Screw size Applicable cable outer diameter ST-M 1. Black M P1. 7 to 13 dia. Dimensions (Unit: mm) 2 37 9 17 For details or to make purchases, contact your OMR sales representative. 27.6 13.4 Note: A seal packing is not included. Applicable seal packing GPM Note: Purchase a seal packing to maintain water resistance. 1

Ratings and Specifications Shielding Shielded Unshielded Item Model -N 3-H -NM 3-H Sensing distance mm % mm % Set distance to 16 mm to 24 mm Differential travel Detectable object 1% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data (Reference Value) on page 3.) Standard sensing object Iron, 6 6 1 mm Iron, 9 9 1 mm Response frequency *1 Hz Hz Power supply voltage (operating voltage range) Current consumption Control current output Residual voltage Indicators Operation mode Protection circuits Ambient temperature range Ambient humidity range Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance (destruction) Shock resistance (destruction) to VDC, including % ripple (p-p) ma max. ma max. 2 V max. (at ma load current) Power indicator (green), detection indicator (yellow) Degree of protection IEC IP67 *2 Connection method Weight (packed state/ only) Materials Accessories Case Sensing surface Terminal base Power supply reverse polarity protection, output reverse polarity protection, and load short-circuit protection Operating and storage: 2 to 7 C (with no icing or condensation) Operating and storage: 3% to 9% (with no condensation) 1% max. of sensing distance at 23 C in the temperature range of 2 to 7 C 2% max. of sensing distance at 24 VDC in the range of 24 VDC 1% 2% max. of sensing distance at 12 VDC in the range of 12 VDC 1% M min. (at VDC) between current-carrying parts and case 1, VAC, at /6 Hz for 1 min. between current-carrying parts and case to Hz with a 1.-mm double amplitude in X, Y, and Z directions m/s 2 3 times each in six directions Terminal block Approx. g/approx. 2 g Polyamide (PA) Polyamide (PA) Polyamide (PA) Instruction manual *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. When the recommended cable gland is used. 2

X X Engineering Data (Reference Value) Sensing Area Shielded Models -N 3-H 3 2 Y Unshielded Models -NM 3-H 3 2 Y 1 1 4 4 Sensing Head Distance Y (mm) Influence of Sensing Object Size and Materials Shielded Models Unshielded Models -N 3-H -NM 3-H 4 4 Sensing Head Distance Y (mm) 2 1 d t = 1 mm X Iron Stainless steel SUS4 3 2 d t = 1 mm X Iron Stainless steel SUS4 Brass 1 Brass Aluminum Aluminum Copper Copper 4 6 7 Side length of sensing object: d (mm) 4 6 7 Side length of sensing object: d (mm) I/O Circuit Diagrams NPN Model Operation mode Timing charts Output circuit -NE3-H -NME3-H Outside of sensing area Sensing object Sensing area (%) Rated sensing distance Lit Detection indicator Not lit (yellow) Control output, NO Control output, NC main circuit 1 +V 4 NO output 2 NC output 3 V Terminal arrangement Cable connecting side PNP Model Operation mode Timing charts Output circuit Outside of sensing area Sensing object Sensing area 1 +V -NF3-H -NMF3-H (%) Rated sensing distance Lit Detection indicator Not lit (yellow) Control output, NO Control output, NC main circuit NO output 4 NC output 2 3 V Terminal arrangement Cable connecting side 3

Safety Precautions Be sure to read the precautions for all models in the website at: http//www.ia.omron.com/. Indication and Meaning for Safe Use WARNING Precautions for Safe Use Precautions for Correct Use Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. Supplementary comments on what to do or avoid doing, to use the product safely. Supplementary comments on what to do or avoid doing, to prevent failure to operate, or undesirable effect on product performance. WARNING This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose. Never use this product with an AC power supply. Otherwise, explosion may result. Precautions for Safe Use The following precautions must be observed to ensure safe operation. 1. Do not use the product in an environment where flammable or explosive gas is present. 2. Do not attempt to disassemble, repair, or modify the product. 3. Power Supply Voltage Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in damage or burnout. 4. Incorrect Wiring Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or burnout.. Connection without a If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply. 6. Dispose of this product as industrial waste. UL Certification This product is certified for UL standards, but the certification is not applicable to metal piping to the conduit section. For UL applications, use a certified cable grip. Precautions for Correct Use Operating Environment 1. Do not install the product in the following locations. Doing so may result in product failure or malfunction. (1) Outdoor locations directly subject to sunlight, rain, snow, water droplets, or oil. (2) Locations subject to atmospheres with chemical vapors, in particular solvents and acids. (3) Locations subject to corrosive gases. (4) Locations subject to shocks or vibration. 2. The may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a highfrequency electric field. Please refer to the Precautions for Correct Use of Photoelectric s on the OMR website (www.ia.omron.com) for typical measures. 3. Laying the wiring in the same conduit or duct as high-voltage wires or power lines may result in incorrect operation and damage due to induction. Wire the using a separate conduit or independent conduit. 4. Cleaning Never use thinner or other solvents. Otherwise, the product surface may be dissolved.. Do not subject the to strong shock. Otherwise, the Head may be damaged. Power The is ready to sense an object within ms after turning the power. If the load and are connected to different power supplies, always turn the power first. Power Output pulses may occur when the power supply is turned. Turn the power supply to the load or load line first. Effects of Surrounding Metals When the is embedded in metal, make sure that the clearances given in the following table are maintained. B A B C F E D E (Unit: mm) Model A B C D E F -N 3-H 6 -NM 3-H 4 2 4 9 4

Mutual Interference If more than one is installed face-to-face or side-byside, make sure that the distances between two units adjacent to each other are the same as or larger than the corresponding values shown in the following table. Switching the Sensing Direction 1. Remove two screws. A B 2. Lifting the sensing surface separates it from the case. A (Unit: mm) (2) Model A B -N 3-H 17 1 -NM 3-H 28 Tightening Torque Tighten bolts and screws with the specified torque. Between case and terminal Terminal screws 1.8 N m 1. N m 3. When positioning the sensing surface to the side, rotate it to the required position, then fit it into the case. (The possible positions are, 9, 18, and 27. Do not forcefully rotate the sensing surface.) (1) 4. Secure it with the screws.

Dimensions (Unit: mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. s -NE3-H -NF3-H -NME3-H -NMF3-H Power indicator (green) Two,.3-dia. holes Two, 7.3 Two,.3 4 Detection indicator (yellow) Front Detection 4 46 118 6 Conduit screw, M P1. 4 16.3 11 Detection indicator (yellow) 4 Power indicator (green) Mounting Hole Dimensions Four,.-dia. (or M) holes ±.2 6±.2 Cat. No. F17E-EN-1 In the interest of product improvement, specifications are subject to change without notice. OMR EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 68 13 Fax: +31 23 68 13 88 industrial.omron.eu