UNSHIELDED MULTI CONDUCTOR

Similar documents
Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Detailed Specifications & Technical Data

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-RHH/RHW-2 USE-2 Copper

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Omni Cable is a master distributor of specialty wire and cable selling

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

MC, THHN/THWN-2 Copper


DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

75 OHM COAXIAL CABLE (RG6)

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Signal & Instrumentation

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

TUNNELING POWER CABLES

Variable Frequency Drive (VFD) Cable Solutions

IEEE 1580 TYPE T/N CABLE

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

Detailed Specifications & Technical Data

MC or MV-105 Copper, TR-XLPE Insulated

Interconnect Cable Simplex and Duplex

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

MEDIUM VOLTAGE

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

Mining and Petrochemical Tray-Rated Fiber Optic Cables

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Easier! Faster! Safer!

CABLED TWISTED PAIRS CONDUCTORS

CABLED SINGLE CONDUCTORS

Detailed Specifications & Technical Data

C-L-X Aluminum Sheath Type IEC

Section 8. Portable Cordage & Power Cable

Electronic Instrumentation

Power & Control Cable IEC

fiber optic cable Outdoor Cables

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Power & Control Cable IEC

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Product Descriptions

Data sheet chainflex CF210.UL

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

Power & Control Cables

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

E R C. R E R C ; ; W T E C

Okoguard -Okoseal Type IEC

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

Power & Control Cable IEC

Caledonian Fire Resistant Optic Fiber Cables

PVC motor cables unshielded

MIC Unitized Plenum Cables, Fibers

Telephone Cables Fire Warning Cables

Medium Voltage Power Cables

Introduction. Selection Guide: Shielded Multi-Conductor Computer Cables for RS-232 Applications. Multi Applications Demand Multiple Choice

INFORMATION. Hybrid cables. Description

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

Airfield Ground Lighting

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

Automotive Cables. The Global Cable Solutions Company

POLYCAB WIRES PVT. LTD.

Caledonian Flame Retardant RS485 Databus Cables

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

POLYCAB WIRES PVT. LTD.

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

Type MMV-WP Medium Voltage Wind Power Cable

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

Electronic Cable C O N N E C T I N G T E C H N O LO G Y W I T H P E R F O R M A N C E & P R E C I S I O N

Technical Data Sheet Shielded (CY) PVC Control Cable

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

Data sheet chainflex CF240

MIC Plenum Cables, 2-24 Fibers

Wired for Power Generation

Article number: Sheath marking ACE - TKF LTC-S RP 12x SM G.657.A1 (2x6) A-DQ(ZN)B2Y {Batch} {Year} {Length}

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable

THERMOCOUPLE CABLES THERMOELECTRICITY

High Voltage Copper, Smooth Aluminum Shield/Sheath

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

POLYCAB WIRES PVT. LTD.

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

POLYCAB WIRES PVT. LTD.

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

POLYCAB WIRES PVT. LTD.

Transcription:

PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. 1. CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 4. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT 4 and UL 1581 vertical tray flame tests. 5. TEMPERATURE: 105 C 6. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Conductors IN 1000 Ft. 323-011-2201-B 22 2 0.20 19 323-011-2001-B 20 2 0.21 23 323-011-1801-B 18 2 0.23 28 323-011-1601-B 16 2 0.26 37 323-011-1401-B 14 2 0.32 60 323-011-1201-B 12 2 0.42 95 323-012-2203-B 22 3 0.21 24 323-012-2003-B 20 3 0.23 28 323-012-1803-B 18 3 0.25 37 323-012-1603-B 16 3 0.27 50 323-012-1403-B 14 3 0.34 80 Color Code for two conductor: Black and Red. Color Code for three conductor: Black, Red and White. Anixter Inc. 1999 13-1

PLTC 300 VOLT PVC Insulation 105 C, 300 Volts SHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. 1. CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. ASSEMBLY: Cabled with an overall aluminum mylar shield and stranded tinned copper drain wire. 4. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 5. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests. 6. TEMPERATURE: 105 C 7. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Conductors IN 1000 Ft. 323-023-2201-B 22 2 0.20 25 323-023-2001-B 20 2 0.22 25 323-023-1801-B 18 2 0.24 33 323-023-1601-B 16 2 0.26 38 323-023-1401-B 14 2 0.33 70 323-023-1201-B 12 2 0.43 112 323-024-2203-B 22 3 0.21 27 323-024-2003-B 20 3 0.23 32 323-024-1803-B 18 3 0.25 41 323-024-1603-B 16 3 0.28 56 323-024-1403-B 14 3 0.35 90 Color Code for two conductor: Black and Red. Color Code for three conductor: Black, Red and White. 13-2 Anixter Inc. 1999

PLTC 300 VOLT PVC Insulation 105 C, 300 Volts OVERALL SHIELDED SINGLE AND MULTI PAIR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. 1. CONDUCTORS: Stranded, bare copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. PAIRS: Pairs are twisted with a suitable lay to reduce magnetic interference and color coded black and white. Each pair is printed numerically to ensure easy identification. 4. ASSEMBLY: The individual pairs are cabled together to form round completed assembly. Overall aluminum/polyester foil shield with stranded tinned copper drain wire. All cable assemblies include a communication wire for calibration. 5. OVERALL JACKET: Flame retardant, sunlight resistant, black PVC. A rip cord is included for jacket removal. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft. 323-221-2001 20 1.23 24 323-221-2002 20 2.38 58 323-221-2003 20 3.35 66 323-221-2004 20 4.42 87 323-221-2006 20 6.46 114 323-221-2008 20 8.50 139 323-221-2010 20 10.57 165 323-221-2012 20 12.59 190 323-221-2016 20 16.67 250 323-221-2020 20 20.71 308 323-221-2024 20 24.80 351 323-221-2036 20 36.83 480 323-221-2050 20 50 1.10 660 323-221-1801 18 1.26 45 323-221-1802 18 2.44 83 323-221-1803 18 3.45 100 323-221-1804 18 4.48 125 323-221-1806 18 6.53 149 NOTE: Other pair counts available upon request. Diameters and weights may vary between manufacturers. Anixter Inc. 1999 13-3

PLTC 300 VOLT Continued OVERALL SHIELDED SINGLE AND MULTI PAIR PVC Insulation 105 C, 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft. 323-221-1808 18 8.57 200 323-221-1810 18 10.62 239 323-221-1812 18 12.66 295 323-221-1816 18 16.76 370 323-221-1820 18 20.82 450 323-221-1824 18 24.89 530 323-221-1836 18 36 1.02 780 323-221-1850 18 50 1.29 1230 323-221-1601 16 1.26 42 323-221-1602 16 2.46 103 323-221-1603 16 3.48 130 323-221-1604 16 4.51 160 323-221-1606 16 6.59 203 323-221-1608 16 8.67 280 323-221-1610 16 10.72 322 323-221-1612 16 12.77 400 323-221-1616 16 16.86 510 323-221-1620 16 20.95 640 323-221-1624 16 24 1.05 750 323-221-1636 16 36 1.23 1110 323-221-1650 16 50 1.60 1352 NOTE: Other pair counts available upon request. Diameters and weights may vary between manufacturers. 13-4 Anixter Inc. 1999

PLTC 300 VOLT PVC Insulation 105 C, 300 Volts INDIVIDUALLY SHIELDED MULTI PAIR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduits, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. 1. CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. COLOR CODE: Pairs color coded black, red and numbered. 4. ASSEMBLY: Twisted pairs each with an overall aluminum mylar shield and stranded tinned copper drain wire. 5. OVERALL JACKET: Sunlight resistant chrome polyvinyl chloride (PVC) jacket. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft. 323-035-2202-B 22 2 0.32 48 323-035-2203-B 22 3 0.33 60 323-035-2204-B 22 4 0.36 73 323-035-2206-B 22 6 0.44 114 323-035-2209-B 22 9 0.50 150 323-035-2211-B 22 11 0.55 174 323-035-2219-B 22 19 0.69 288 323-035-2251-B 22 51 1.05 745 323-036-1802-B 18 2 0.38 70 323-036-1803-B 18 3 0.42 100 323-036-1804-B 18 4 0.49 124 323-036-1806-B 18 6 0.55 177 323-036-1809-B 18 9 0.67 262 323-036-1811-B 18 11 0.69 307 323-036-1815-B 18 15 0.77 393 NOTE: Other pair counts available upon request. Anixter Inc. 1999 13-5

PLTC 300 VOLT PVC Insulation 105 C, 300 Volts BELDEN OVERALL SHIELDED MULTI PAIR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. 1. CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. COLOR CODE: Pairs color coded black, red and numbered. 4. ASSEMBLY: Pairs are cabled with an overall aluminum/polyester shield and stranded tinned copper drain wire. 5. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable passes CSA FT4 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft. 323-023-2202-B 22 2 0.31 43 323-023-2203-B 22 3 0.33 56 323-023-2204-B 22 4 0.35 64 323-023-2206-B 22 6 0.43 93 323-023-2209-B 22 9 0.49 123 323-023-2211-B 22 11 0.54 145 323-023-2215-B 22 15 0.59 179 323-023-2219-B 22 19 0.63 223 323-023-2227-B 22 27 0.74 344 323-023-2251-B 22 51 0.95 595 323-035-1802-B 18 2 0.36 66 323-035-1803-B 18 3 0.40 90 323-035-1804-B 18 4 0.45 110 323-035-1806-B 18 6 0.48 145 323-035-1809-B 18 9 0.56 202 323-035-1811-B 18 11 0.68 254 323-035-1815-B 18 15 0.75 322 NOTE: Other pair counts available upon request. 13-6 Anixter Inc. 1999

PVC Insulation 105 C, 300 Volts PLTC 300 VOLT INDIVIDUAL AND OVERALL SHIELDED MULTI PAIR For use as instrumentation cable inside or outside in control applications. Individually and overall shielded for greater isolation and noise reduction. Suitable for installation in trays, troughs, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. 1. CONDUCTORS: Bare copper, Class B, concentric stranded. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. PAIRS: Each pair is twisted with a suitable lay to reduce magnetic interference and color coded black and white. Each pair is also printed numerically to ensure easy identification. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied. 4. ASSEMBLY: The individual pairs are cabled together to form a substantially circular cross-section of the completed assembly. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied overall. All cable assemblies include a communication wire for calibration and a rip cord for jacket removal. 5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC) jacket. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft. 323-231-2002 20 2.42 61 323-231-2003 20 3.43 72 323-231-2004 20 4.44 105 323-231-2006 20 6.53 145 323-231-2008 20 8.56 170 323-231-2012 20 12.69 248 323-231-2016 20 16.77 315 323-231-2024 20 24.95 475 323-231-2036 20 36 1.06 660 323-231-2050 20 50 1.28 880 323-231-1802 18 2.46 91 323-231-1803 18 3.47 122 NOTE: Other pair counts available upon request. Diameters and weights may vary between manufacturers. Anixter Inc. 1999 13-7

Continued PVC Insulation 105 C, 300 Volts PLTC 300 VOLT INDIVIDUAL AND OVERALL SHIELDED MULTI PAIR Conductor Size Anixter of Weight Lbs. AWG Pairs IN 1000 Ft. 323-231-1804 18 4.51 148 323-231-1806 18 6.60 210 323-231-1808 18 8.69 270 323-231-1812 18 12.84 380 323-231-1816 18 16.94 490 323-231-1824 18 24 1.13 700 323-231-1836 18 36 1.26 1010 323-231-1850 18 50 1.51 1350 323-231-1602 16 2.48 131 323-231-1603 16 3.49 135 323-231-1604 16 4.55 195 323-231-1606 16 6.59 276 323-231-1608 16 8.76 350 323-231-1612 16 12.91 520 323-231-1616 16 16 1.05 660 323-231-1624 16 24 1.22 970 323-231-1636 16 36 1.41 1440 323-231-1650 16 50 1.65 1668 NOTE: Other pair counts available upon request. Diameters and weights may vary between manufacturers. 13-8 Anixter Inc. 1999

PLTC 300 VOLT PVC Insulation 105 C, 300 Volts OVERALL SHIELDED SINGLE AND MULTI TRIAD For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. 1. CONDUCTORS: Bare copper, Class B, concentric stranded. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. TRIADS: Each triad is twisted with a suitable lay to reduce magnetic interference and color coded black, white and red. Each triad is also printed numerically to ensure easy identification. 4. ASSEMBLY: The individual triads are cabled together to form a substantially circular cross-section of the completed assembly. Overall aluminum/polyester foil shield with stranded tinned copper drain wire. All cables include a communication wire for calibration and a rip cord for jacket removal. 5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC). 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests. 6. TEMPERATURE: 105 C 7. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Triads IN 1000 Ft. 323-321-2001 20 1.30 30 323-321-2004 20 4.44 119 323-321-2012 20 12.69 282 323-321-2016 20 16.76 356 323-321-2024 20 24.93 560 323-321-2036 20 36 1.19 745 323-321-1801 18 1.32 45 323-321-1804 18 4.53 170 323-321-1812 18 12.86 430 323-321-1816 18 16.99 580 323-321-1824 18 24 1.20 700 323-321-1836 18 36 1.45 1368 323-321-1601 16 1.35 53 323-321-1604 16 4.57 210 323-321-1612 16 12.97 600 323-321-1616 16 16 1.14 750 323-321-1636 16 36 1.52 1590 NOTE: Other triad counts available upon request. Diameters and weights may vary between manufacturers. Anixter Inc. 1999 13-9

PVC Insulation 105 C, 300 Volts PLTC 300 VOLT INDIVIDUAL AND OVERALL SHIELDED MULTI TRIAD For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725. 1. CONDUCTORS: Bare copper, Class B, concentric stranded. 2. INSULATION: 105 C polyvinyl chloride (PVC). 3. TRIADS: Each triad is twisted with a suitable lay to reduce magnetic interference and color coded black. Each triad is also printed numerically to ensure easy identification. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied. 4. ASSEMBLY: The individual triads are cabled together to form a substantially circular cross-section of the completed assembly. An aluminum/polyester foil shield with stranded tinned copper drain wire is applied overall. All cable assemblies include a communication wire for calibration and a rip cord for jacket removal. 5. OVERALL JACKET: Flame retardant, sunlight resistant, black polyvinyl chloride (PVC) jacket. 6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13. Finished cable meets IEEE 383 and UL 1581 vertical tray flame tests. 7. TEMPERATURE: 105 C 8. VOLTAGE: 300 Volts Conductor Size Anixter of Weight Lbs. AWG Triads IN 1000 Ft. 323-331-2004 20 4.50 128 323-331-2008 20 8.57 220 323-331-2012 20 12.78 323 323-331-2016 20 16.87 411 323-331-2024 20 24.97 675 323-331-2036 20 36 1.27 900 323-331-1804 18 4.54 182 323-331-1808 18 8.67 410 323-331-1812 18 12 1.04 590 323-331-1816 18 16 1.16 780 323-331-1824 18 24 1.26 850 323-331-1836 18 36 1.58 1850 323-331-1604 16 4.61 240 323-331-1612 16 12 1.04 690 323-331-1616 16 16 1.16 890 323-331-1636 16 36 1.58 1850 NOTE: Other triad counts available upon request. Diameters and weights may vary between manufacturers. 13-10 Anixter Inc. 1999

PLTC ISA/IEC SP-50 Twisted Pair Orange Jacket 300 Volts BELDEN DATABUS FIELDBUS Bi-directional, digital signal cable used to replace traditional high pair count 4-20ma industrial PLTC cable for fieldbus devices. 1. CONDUCTORS: Tinned, stranded copper. 2. INSULATION: Type A & B Polyethylene (PE). High speed Cellular polyethylene. 3. SHIELD: 100% aluminum/polyester. 4. OVERALL JACKET: Orange polyvinyl chloride (PVC). 5. STANDARDS: Conforms to ISA/IEC SP-50 fieldbus physical layer specification. Meets NEC Article 725 requirements for Type PLTC. Also meets UL and CSA Type CM requirements. Cond. Nominal Belden Size Imped. Capacitance O.D. Anixter Part of Type AWG Stranding Pairs ohms Speed pf/ft. IN B3076F 3076F A 18 7 x 26 1 100 31.25 kb/s 25.245 B3077F 3077F B 22 7 x 30 1 100 31.25 kb/s 25.201 B3078F 3078F High Speed 22 7 x 30 1 150 1 or 2.5 Mb/s 9.373 NOTE: European Profibus cable (Belden Part No. 3079F) available upon request. Anixter Inc. 1999 13-11

PLTC Polyolefin Insulation Shielded 600 Volts BELDEN DATATRAY TWINAX For use in most programmable logic control systems (PLCs) and distributed control systems (DCS) in industrial environments. May be installed in cable tray or conduit for a variety of data applications (RS-232, 422 & 485). 1. CONDUCTOR: Annealed, tinned copper. 2. INSULATION: Low attenuation, flame-retardant polyolefin. 3. SHIELD: 100% coverage aluminum/polyester and 55% coverage tinned copper braid. 4. OVERALL JACKET: Dark blue, sunlight resistant, polyvinyl chloride (PVC). 5. STANDARDS: Meets the UL requirements for Type PLTC cable. Meets the UL 1581 vertical tray 70,000 BTU flame test. Meets NEC Article 725 for Class 2 (CL2) circuits and Article 800 for Communications general purpose (CM). Also meets CSA Type CM requirements. Conductor Nominal Belden Size Impedance Capacitance O.D. Anixter Part of Weight Lbs. AWG Stranding Pairs ohms pf/ft. IN 1000 Ft. B3072F 3072F 18 7 x 26 1 78 19.7.315 50 B3073F 3073F 18 7 x 26 1 100 15.5.370 64 B3074F 3074F 18 7 x 26 1 124 12.5.450 81 B3075F 3075F 18 7 x 26 1 150 10.3.615 143 NOTE: Multi pairs/multi conductors available. Wet location rating and Oil Res II jacket available. Any Datatray cable may be armored upon request. 13-12 Anixter Inc. 1999

PLTC Aluminum Armor 300 Volts BELDEN INDUSTRIAL AUTOMATION Used in industrial locations requiring extra mechanical protection and system reliability for high speed electronic signalling. 1. CABLE CORE: Cable design configurations for the following PLC manufacturers: Allen Bradley, Square D: Belden Pt. # 129463 Allen Bradley: Belden Pt. # 129842, 128723 IBM, Foxboro: Belden Pt. # 129207 Modicon: Belden Pt. # 129114, 129841 GE Fanuc, DEC: Belden Pt. # 129182 DEC, Foxboro, Hewlett Packard: Belden Pt. # 129880 IBM: Belden Pt. # 129269 Honeywell: Belden Pt. # 129729 2. ARMOR: Aluminum interlocked. 3. OVERALL JACKET: Polyvinyl chloride (PVC). 4. STANDARDS: Meets UL 1581 70,000 BTU flame test. Meets CSA FT4 flame test requirements. Low acid gas outer jacket per CSA. Conductor Belden Size Inner Jacket Armor Outer Jacket Anixter Part Weight Lbs. UL and CSA AWG IN IN IN 1000 Ft. Designation 317-010-2402-BA 129729 24.317.550.650 154 CM 318-011-2203-BA 128777 22.273.490.590 143 CM 318-198-2202-BA 128723 22.240.455.560 117 CM 317-011-2401A-BA 129841 24.232.470.560 135 CM 317-011-2402A-BA 129842 24.340.560.660 175 CM 308-011-0622A-BA 129268 22.260.475.580 136 CL2 308-011-0621-BA 129269 22.240.460.560 131 CL2 318-298-2201DS-BA 129182 22.345.565.670 153 CL2 310-035-9838-BA 129207 20.330.540.640 173 CL2 309-011-7897A-BA 129463* 20.243.460.560 133 CM 308-011-0066-BA 129114 18.270.490.590 137 CM 308-011-0063-BA 129290 18.290.505.610 161 CL2 307-011-011A-BA 128261 18.405.620.730 224 CMG 308-011-0114-BA 129292 14.405.620.730 211 CMG 308-075-0501-BA 129880 12.405.620.730 248 CL2 309-047-1244-BA 129860 16.440.655.765 241 CL2 * This product is frequently referred to as Allen Bradley armored Blue Hose. Remove 12 from Belden part number to get core part number (e.g., 129463 is armored Belden 9463). NOTE: Galvanized steel interlocked armor available upon request. Anixter Inc. 1999 13-13

PVC-Nylon Insulation 90 C, 600 Volts PVC-NYLON/PVC UNSHIELDED AND SHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications and suitable for direct burial. UL Listed for installation in trays, troughs, channels, conduit and wireways in accordance with Articles 318, 340 and 501 of the NEC. TC 600 VOLT 1. CONDUCTORS: Stranded, tinned copper. 2. INSULATION: 90 C polyvinyl chloride (PVC), nylon overcoat. 3. COLOR CODE: Conductors are color coded black, red. 4. ASSEMBLY: Shielded cables are cabled with an overall aluminum/polyester shield and stranded, tinned copper drain wire. 5. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC) jacket, suitable for outdoor use and direct burial. 6. STANDARDS: Meets requirements of UL 1277 and passes the UL 1581 vertical tray flame test. 7. TEMPERATURE: 90 C 8. VOLTAGE: 600 Volts Unshielded Conductor Size Anixter of Weight Lbs. AWG Conductors IN 1000 Ft. B9486 18 2 0.28 44 B9487 16 2 0.31 54 B9488 14 2 0.36 76 B9489 12 2 0.38 96 Shielded B9341 18 2 0.28 47 B9342 16 2 0.30 60 B9343 14 2 0.36 88 B9344 12 2 0.38 115 13-14 Anixter Inc. 1999

TC 600 VOLT PVC-Nylon Insulation 90 C, 600 Volts PVC-NYLON/PVC SHIELDED MULTI PAIR For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication. 1. CONDUCTORS: Bare copper, Class B stranded per ASTM B-8. 2. INSULATION: Polyvinyl chloride (PVC) and nylon. Pairs are color coded black and white and numbered. Triads are black, white, red and numbered. 3. SHIELDING: Shields are Aluminum/polyester. Overall drain wire is seven-strand tinned copper. Where applicable, individual drain wires are used, also of seven-strand, tinned copper construction. 4. OVERALL JACKET: Sunlight resistant polyvinyl chloride (PVC). 5. STANDARDS: Meets the requirements of UL 1277 and passes the UL 1581 vertical tray flame test. 6. TEMPERATURE: 90 C 7. VOLTAGE: 600 Volts Conductor Overall Jacket Nominal Anixter* Size of Thickness O.D. Weight Lbs. AWG Pairs Triads IN IN 1000 Ft. 2AS-1801POS 18 1.045.280 41 2AS-1801TOS 18 1.045.445 80 2AS-1802POS 18 2.045.440 72 2AS-1803POS 18 3.045.465 90 2AS-1804POS 18 4.045.505 110 2AS-1806POS 18 6.060.598 167 2AS-1808POS 18 8.060.652 204 2AS-1812POS 18 12.060.770 277 2AS-1816POS 18 16.080.905 387 2AS-1824POS 18 24.080 1.055 532 2AS-1836POS 18 36.080 1.190 739 2AS-1802SPOS 18 2.045.445 84 2AS-1803SPOS 18 3.045.480 106 2AS-1804SPOS 18 4.045.555 145 2AS-1806SPOS 18 6.060.639 203 2AS-1808SPOS 18 8.060.700 250 2AS-1812SPOS 18 12.060.845 350 2AS-1816SPOS 18 16.080.960 475 2AS-1824SPOS 18 24.080 1.130 670 2AS-1836SPOS 18 36.080 1.345 957 *POS Pair(s) Overall Shield. TOS Triad(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. NOTE: Diameters and weights may vary between manufacturers. Anixter Inc. 1999 13-15

TC 600 VOLT Continued PVC-NYLON/PVC SHIELDED MULTI PAIR PVC-Nylon Insulation 90 C, 600 Volts Conductor Overall Jacket Nominal Anixter* Size of Thickness O.D. Weight Lbs. AWG Pairs Triads IN IN 1000 Ft. 2AS-1601POS 16 1.045.300 52 2AS-1601TOS 16 1.045.315 63 2AS-1602POS 16 2.045.470 93 2AS-1603POS 16 3.045.505 117 2AS-1604POS 16 4.060.575 160 2AS-1606POS 16 6.060.660 282 2AS-1608POS 16 8.060.745 330 2AS-1612POS 16 12.080.825 370 2AS-1616POS 16 16.020.970 513 2AS-1624POS 16 24.080 1.320 740 2AS-1636POS 16 36.080 1.285 1040 2AS-1602SPOS 16 2.045.495 105 2AS-1603SPOS 16 3.045.520 137 2AS-1604SPOS 16 4.060.600 188 2AS-1606SPOS 16 6.060.685 270 2AS-1608SPOS 16 8.060.745 337 2AS-1612SPOS 16 12.080.940 498 2AS-1616SPOS 16 16.080 1.055 635 2AS-1624SPOS 16 24.080 1.260 903 2AS-1636SPOS 16 36.080 1.480 1290 2AS-1401POS 14 1.045.360 65 2AS-1401TOS 14 1.045.360 94 *POS Pair(s) Overall Shield. TOS Triad(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. NOTE: Diameters and weights may vary between manufacturers. 13-16 Anixter Inc. 1999

TC 600 VOLT XLP Insulation Hypalon Jacket 90 C, 600 Volt XLP/HYPALON SHIELDED MULTI PAIR For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication. 1. CONDUCTORS: Annealed, tinned copper in accordance with ASTM B-3 and B-33. Concentric stranded, Class B per ASTM B-8. 2. INSULATION: Cross-linked polyethylene (XLP), per ICEA S-66-524 (NEMA WC7). UL rated VW-1 conductors. 3. PAIRS/TRIADS: Each pair/triad is twisted to a 2 in. lay. Color coded: pairs black/white, triads black/white/red with alphanumeric designation (1-ONE). 4. ASSEMBLY: The individually shielded pairs are cabled together with non-hygroscopic and flame retardant fillers as necessary to form a circular cross section of the assembly. A binding tape, when required, shall be applied over cable core. 5. SHIELDING: The entire cable assembly is shielded with polyester backed/aluminum tape and tinned copper drain wire. 6. OVERALL JACKET: Flame retardant Hypalon (CSPE). 7. STANDARDS: Meets the requirements of UL 1277. Finished cable passes UL 1581 70,000 BTU and ICEA T-29-520 210,000 BTU flame tests. UL listed as sunlight resistant and rated for direct burial. 8. TEMPERATURE: 90 C 9. VOLTAGE: 600 Volts Conductor Insulation Overall Jacket Nominal Size of Thickness Thickness O.D. Anixter* Weight Lbs. AWG Pairs Triads IN IN IN 1000 Ft. 2RH-1601POS 16 1.030.045.340 66 2RH-1601TOS 16 1.030.045.365 82 2RH-1602POS 16 2.030.045.595 116 2RH-1603POS 16 3.030.060.640 185 2RH-1604POS 16 4.030.060.690 229 2RH-1606POS 16 6.030.060.735 320 2RH-1608POS 16 8.030.080.920 443 2RH-1612POS 16 12.030.080 1.085 611 2RH-1624POS 16 24.030.080 1.475 1130 2RH-1636POS 16 36.030.080 1.600 1728 2RH-1602SPOS 16 2.030.060.595 116 2RH-1603SPOS 16 3.030.060.640 185 *POS Pair(s) Overall Shield. TOS Triad(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. NOTE: Diameters and weights may vary between manufacturers. Anixter Inc. 1999 13-17

TC 600 VOLT XLP/HYPALON SHIELDED MULTI PAIR Continued XLP Insulation Hypalon Jacket 90 C, 600 Volt Conductor Insulation Overall Jacket Nominal Size of Thickness Thickness O.D. Anixter* Weight Lbs. AWG Pairs Triads IN IN IN 1000 Ft. 2RH-1604SPOS 16 4.030.060.690 229 2RH-1606SPOS 16 6.030.060.735 320 2RH-1608SPOS 19 8.030.080.920 443 2RH-1612SPOS 16 12.030.080 1.085 611 2RH-1624SPOS 16 24.030.080 1.475 1130 2RH-1636SPOS 16 36.030.110 1.600 1728 2RH-1401POS 14 1.030.045.375 75 2RH-1401TOS 14 1.030.045.375 105 *POS Pair(s) Overall Shield. TOS Triad(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. NOTE: Diameters and weights may vary between manufacturers. 13-18 Anixter Inc. 1999

TC 600 VOLT EPR Insulation CPE Jacket 90 C, 600 Volt EPR/CPE SHIELDED MULTI PAIR For use indoors or outdoors and for installation in trays, troughs, channels, ducts and direct burial. Designed for telemetering, signals, relays and communication. 1. CONDUCTORS: Annealed, tinned copper in accordance with ASTM B-3 and B-33. Concentric stranded, Class B per ASTM B-8. 2. INSULATION: Ethylene propylene rubber (EPR), per ICEA S-68-516. UL rated VW-1 conductors. 3. PAIRS/TRIADS: Each pair/triad is twisted to a 2 in. lay. Color coded: pairs black/white, triads black/white/red with alphanumeric designation (1-ONE). 4. ASSEMBLY: The individually shielded pairs are cabled together with non-hygroscopic and flame retardant fillers as necessary to form a circular cross section of the assembly. A binding tape, when required, shall be applied over cable core. 5. SHIELDING: The entire cable assembly is shielded with polyester backed/aluminum tape and tinned copper drain wire. 6. OVERALL JACKET: Flame retardant chlorinated polyethylene (CPE). 7. STANDARDS: Meets the requirements of UL 1277. Finished cable passes UL 1581 70,000 BTU and ICEA T-29-520, 210,000 BTU flame tests. UL listed as sunlight resistant and rated for direct burial. 8. TEMPERATURE: 90 C 9. VOLTAGE: 600 Volts Conductor Insulation Overall Jacket Nominal Size of Thickness Thickness O.D. Anixter* Weight Lbs. AWG Pairs Triads IN IN IN 1000 Ft. 2MR-1601POS 16 1.025.045.318 59 2MR-1601TOS 16 1.025.045.336 75 2MR-1602POS 16 2.025.045.365 92 2MR-1603POS 16 3.025.060.587 181 2MR-1604POS 16 4.025.060.627 220 2MR-1606POS 16 6.025.060.680 250 2MR-1608POS 16 8.025.080.850 400 2MR-1612POS 16 12.025.080 1.022 562 2MR-1624POS 16 24.025.080 1.351 1042 2MR-1636POS 16 36.025.080 1.395 1128 2MR-1602SPOS 16 2.025.060.583 166 2MR-1603SPOS 16 3.025.060.591 189 2MR-1604SPOS 16 4.025.060.638 231 2MR-1606SPOS 16 6.025.080.775 295 2MR-1608SPOS 16 8.025.080.865 416 2MR-1612SPOS 16 12.025.080 1.047 581 2MR-1624SPOS 16 24.025.080 1.393 1067 2MR-1636SPOS 16 36.025.110 1.735 1419 *POS Pair(s) Overall Shield. SPOS Shielded Pairs with Overall Shield. TOS Triad(s) Overall Shield. NOTE: Diameters and weights may vary between manufacturers. Anixter Inc. 1999 13-19

FIBER OPTIC CABLE 62.5µm/125µm Loose Tube Buffer PVC/PVC TRAY CABLE Suitable for outdoor duct, indoor general purpose and aerial use. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray. 1. FIBER SIZE: 62.5µm/125µm 2. CONSTRUCTION: Loose buffer with gel filling and sunlight resistant polyvinyl chloride (PVC) jacket overall. 3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as OFN per NEC Article 770. Max. Min. Attenuation Bandwidth Max. Tensile Load Min. Bend Radius @850/ @850/ Nom. No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Approx. Anixter of Wt. Lbs. Fibers db/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft. 370-062-IEEE-02 2 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95 370-062-IEEE-04 4 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95 370-062-IEEE-06 6 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95 370-062-IEEE-08 8 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95 370-062-IEEE-12 12 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95 370-062-IEEE-18 18 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95 370-062-IEEE-24 24 3.75/1.5 160/500 600 135 8.9 5.9 0.5 95 13-20 Anixter Inc. 1999

FIBER OPTIC CABLE 62.5µm/125µm Loose Tube Buffer BELDEN TRAYOPTICS PVC Suitable for indoor or outdoor industrial installations. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray. 1. FIBER SIZE: 62.5µm/125µm 2. CONSTRUCTION: Loose buffer with gel filling, central strength member, inner polyvinyl chloride (PVC) jacket, aramid yarn and orange polyvinyl chloride (PVC) jacket overall. 3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as OFNR (2 12 fiber) or OFN (18 24 fiber) per NEC Article 770. Crush resistance: 500 lbs./inch minimum. Max. Min. Attenuation Bandwidth Max. Tensile Load Min. Bend Radius @850/ @850/ Nom. Approx. Belden No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Wt. Anixter Part of Lbs. No. Fibers db/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft. BI100255 I100255 2 3.5/1.0 160/500 600 180 8.68 4.34.434 70 BI100455 I100455 4 3.5/1.0 160/500 600 180 8.68 4.34.434 70 BI100655 I100655 6 3.5/1.0 160/500 600 180 8.68 4.34.434 70 BI400855 I400855 8 3.5/1.0 160/500 600 180 11.18 5.59.559 95 BI601255 I601255 12 3.5/1.0 160/500 600 180 11.18 5.59.559 95 BI601855 I601855 18 3.5/1.0 160/500 600 180 11.18 5.59.559 95 BI602455 I602455 24 3.5/1.0 160/500 600 180 11.18 5.59.559 95 NOTE: Cable with up to 72 fibers available upon request. Anixter Inc. 1999 13-21

FIBER OPTIC CABLE 62.5µm/125µm Loose Tube Buffer BELDEN TRAYOPTICS CPE Suitable for indoor or outdoor industrial installations. This cable meets the flame test required for 300 Volt Power Limited (PLTC) and 600 Volt (TC) tray cables and may be installed in cable tray. 1. FIBER SIZE: 62.5µm/125µm 2. CONSTRUCTION: Loose buffer with gel filling, central strength member, inner CPE jacket, aramid yarn and orange CPE jacket overall. 3. STANDARDS: Meets the IEEE 383 and UL 1277 flame test requirements. UL Listed as OFNR (2 12 fiber) or OFN (18 24 fiber) per NEC Article 770. Crush resistance: 500 lbs./inch minimum Max. Min. Attenuation Bandwidth Max. Tensile Load Min. Bend Radius @850/ @850/ Nom. Approx. Belden No. 1300nm 1300nm Installation Long Term Installation Long Term O.D. Wt. Anixter Part of Lbs. No. Fibers db/km MHz/km Lbs. Lbs. IN IN IN 1000 Ft. BI100266 I100266 2 3.5/1.0 160/500 600 180 8.68 4.34.434 70 BI100466 I100466 4 3.5/1.0 160/500 600 180 8.68 4.34.434 70 BI100666 I100666 6 3.5/1.0 160/500 600 180 8.68 4.34.434 70 BI400866 I400866 8 3.5/1.0 160/500 600 180 11.18 5.59.559 95 BI601266 I601266 12 3.5/1.0 160/500 600 180 11.18 5.59.559 95 BI601866 I601866 18 3.5/1.0 160/500 600 180 11.18 5.59.559 95 BI602466 I602466 24 3.5/1.0 160/500 600 180 11.18 5.59.559 95 NOTE: Cable with up to 72 fibers available upon request. 13-22 Anixter Inc. 1999