CON EDISON EQUIPMENT

Similar documents
SECTION VII METERING INSTALLATIONS

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

AMENDMENT ELECTRIC SERVICE MANUAL 2014

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

New York City Apartment Metering Meter Sockets / Load Centers

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

Customer Requirements Downtown Secondary Network Service

COMMERCIAL QUICK REFERENCE

Approved Contractor Construction e-guide Residential Commercial

CT Metering. CT Metering. Meter Mounting Equipment

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

Design Guide for Integration of Fixed-Mount Circuit Breakers

MP Meter-Pak Meter Centers

General Specifications for Lighthouse Power Pedestal

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

10 Commercial, Industrial, Agricultural Services


Recreational Vehicle Park Electrical Products & Accessories

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

fastfax Rock Solid TM Load Centers General Information


BUSWAY Low Voltage (Pow-R-Flex)

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Metering and Service Installation:

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

A. Submit manufacturer's literature and technical data before starting work.

Design Standard. Purpose: Design Standard:

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages

Indianapolis Power & Light Company

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

MEG Approval Meter Equipment Group

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

SECTION PANELBOARDS

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Panelboards Circuit Breaker / Lighting and Distribution

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

RELOC Modular Wiring Specialty Lighting and Power Systems

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Application guide. Tmax Link OEM UL 891 Switchboard Program

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

American Electric Supply, Inc.

Open-Style Power Distribution Blocks

Air Conditioning Disconnects Molded Case Switch

Quick Connection Panel (QCP) Installation Guide

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

Meter Centers Meter Mounting Devices

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

GE 8000-Line Motor Control Centers

Heavy Duty Safety Switches

Product Specification Sheet #3LD2.1

Selection and Application Guide For use in New England EQUIPMENT

7 Single Family Service

Panelboard Renewal Parts Supplement

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Transfer switch OTEC open or delayed transition

Introduction. Features. Intelligent Technologies Motor Control Center Structures

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

PEU reserves the right to determine all meter locations. Only authorized PEU personnel will determine this location.

Power Mod. Standard Tapboxes.

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs

Quik-Spec Coordination Panelboard Specifications

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

SPECIFICATION BULLETIN

PANELBOARDS SECTION 1

PANELBOARDS C1/C2 SECTION 6

UNDERGROUND SERVICES - SECONDARY

TYPE BLT DISCONNECT SWITCHES

Duke/MEG Approval Meter Equipment Group

Section 6 Electric Metering: Residential

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

6.2. Power Pedestals. Contents

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

Selection and application guide

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Three-Phase Ventilated

Company Switch Installation Instructions and User Manual

Kinetix 5700 Capacitor Modules

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Transcription:

CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200 330.00 484 N-484 30x18x12 400 280.00 484 RTN-484 30x18x12 400 520.00 220 N-220 12x12x8 240.00 104A N-104A DEMAND 120 1000.00 METER 1

CON EDISON TRANS-S ENCLOSURES Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 745 TS-400-208 41x20x10 208 200-400 $1,710.00 745 TS-400-480 41x20x10 480 200-400 1,740.00 750 TS-800-208 48x24x10 208 400-800 2,110.00 750 TS-800-480 48x24x10 480 400-800 2,200.00 745 MS-10P-208 21x14x5 208 30 AMP 295.00 (CONT) 745 MS-10P-480 21x14x5 480 30 AMP 310.00 (CONT) 3 HUB 3 HUB 24.00 3 1/2 HUB 3 1/2 HUB 28.00 4 HUB 4 HUB 30.00 TS-TCP TOP 16.00 CLOSING PLATE 2

CON EDISON 400 AMP TRANS S CURRENT TRANSFORMER CABINET (NEMA 3R) 200 AMP. & 400 AMP., 240 V & 480V AC RATED CATALOG NUMBER TS-400-208 TS-400-480 NOTES: CODE GAUGE GALVANIZED OR GALVANIZED STEEL 2. BUS BAR SHALL BE SILVER OR TIN PLATED AND SHALL BE SIZED PER THE NEC. 3. BUS BAR SHALL BE MOUNTED IN THE CABINET BY MEANS OF STANDOFF INSULATORS OR INSULATED MOUNTING BRACKETS. INSULATING MATERIALS SHALL CONFORM TO THE APPLICABLE SECTIONS OF UL 746 AND UL 94. CABINET SHALL BE UL APPROVED AND N.Y.C. ADVISORY BOARD. 4. THE RIGHT HAND SIDE OF THE CABINET SHALL ALLOW FOR LINE AND LOAD CABLES TO ENTER AND EXIT THROUGH THE BOTTOM OF THE CABINET. THIS SPACE SHALL ALLOW FOR THE CABLES TO MEET THE MINIMUM BENDING RADIUS TO NEAREST PHASE OR NEUTRAL BUS AS PER THE NEC. 5. THE SHORT CIRCUIT WITHSTAND CAPABILITY OF THE CABINET ASSEMBLY SHALL BE A MINIMUM OF 18,000 SYMMETRICAL AMPERES. 6. CABINET DESIGN SHALL HAVE PROVISIONS FOR A SOLID DOOR TO ALLOW FOR THE METER ENCLOSURE TO BE MOUNTED REMOTELY FROM THE CABINET. 7. METERING COMPARTMENT TO BE TOTALLY ISOLATED FROM C. T. COMPARTMENT. FOR REMOTE USE CAT. NO. (IOP - 208MS OR IOP -480MS) AND CONFORM TO MES #751. 8. CABINET MAY BE DESIGNED WITH A SINGLE OR DOUBLE DOOR AS NECESSARY TO CONFORM WITH THE APPLICABLE STANDARDS. OVERALL DIMENSIONS SHALL BE KEPT TO A MINIMUM. 9. HEX HEAD OR THUMB SCREWS MAY BE FURNISHED INSTEAD OF A THREE POINT LATCH. 10. MANUFACTURER SHALL FURNISH AND INSTALL 1/2-13 STUDS WITH SPLIT LOCK WASHERS, RING WASHERS AND HEX NUTS FOR C. T. MOUNTING. 11. USE ONLY MANUFACTURER S APPROVED LUG PROVIDED. LUGS ARE RATED FOR (1) 600 MCM - #4 OR (2) 250 MCM - #4 CABLES. 12. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL BE USED. 13. PROVIDE #12 AWG STRANDED (19/25) THHN COPPER COLOR CODED WIRE FROM TEST SWITCH/METER SOCKET METERING COMPARTMENT INTO C. T. COMPARTMENT. LEAVE 5 FT. OF WIRE FOR FUTURE CONNECTION TO CURRENT TRANSFORMERS. ALL WIRING IN ACCORDANCE WITH CON EDISON MES #195, REV. 9. 14. SECURITY HARDWARE TO BE PROVIDED FOR CT CABINET DOOR AND METER ENCLOSURE - TO BE INSTALLED BY CONTRACTOR. 15. THIS STANDARD SHALL NOT BE USED AS A DESIGN CRITERIA. DIMENSIONS SHOWN ARE RECOMMENDED MINIMUMS ONLY. LARGER DIMENSIONS SHALL BE USED WHERE REQUIRED BY CODE. INSTALLATION DETAILS: 1. MAXIMUM CABLE SIZES: I SET OF 500 KCMILS OR 2 SETS OF 4/0 AWG CU. LUG SIZE RANGES FROM 600 MCM - #4 OR (2) 250 KCMILS - 1/0 IF AL. CABLES ARE USED. 2. USE ONLY MANUFACTURER S APPROVED LUG PROVIDED. 3. 1 FT. CLEARANCE REQUIRED ON THE LEFT (HINGED) SIDE OF THE CABINET TO A WALL OR OBSTRUCTION FOR METER CLEARANCE. MINIMUM OF 6 CLEARANCE ON THE RIGHT. (NON HINGED) SIDE OF THE CABINET, NEEDED FOR INSTALLATION OF LOCKING DEVICES. SPACE BETWEEN ADJACENT CABINETS NO LESS THAN 6 INCHES. (SEE INSTALLATION DETAIL). 4. 265/460 VOLT SERVICE REQUIRES A DISCONNECT SWITCH BEFORE THE CT CABINET. 5. METER ENCLOSURES MOUNTED REMOTELY MUST CONFORM WITH MES 195 IN WIRE SIZING CONNECTIONS, COLOR CODING, ETC. 6. FINAL CONNECTIONS PER MES 195 - FOR 4 WIRE INSTALLATIONS. 3

CON EDISON 800 AMP TRANS S CURRENT TRANSFORMER CABINET (NEMA 3R) 400 600 AMP. 600 & 800 AMP. AMP., & 800240V AMP., & 240 480V V & AC 480V RATED AC RATED CATALOG NUMBER TS-800-208, TTSS--880000--448800 TS-800-480 CON EDISON SPEC.#MES 757 CATALOG NUMBERS TS-800-208 TS-800-480 RTS-800-208 RTS-800-480 MS 10P-208 MS 10P-480 CODE GAUGE GALVANIZED OR GALVANNEALED STEEL. 2. BUS BAR SHALL BE SILVER OR TIN PLATED AND SHALL BE SIZED PER THE NEC. 3. BUS BAR SHALL BE MOUNTED IN THE CABINET BY MEANS OF STANDOFF INSULATORS OR INSULATED MOUNTING BRACKETS. INSULATING MATERIAL SHALL CONFORM TO THE APPLICABLE SECTIONS OF UL 746 AND UL 94. THE CABINET SHALL BE UL, CON EDISON AND N.Y.C. ADVISORY BOARD APPROVED. 4. THE RIGHT HAND SIDE OF THE CABINET SHALL ALLOW FOR LINE AND LOAD CABLES, TO ENTER AND EXIT THROUGH THE TOP OR THE BOTTOM OF THE CABINET. THIS SPACE SHALL ALLOW FOR THE CABLES TO MEET THE MINIMUM BENDING RADIUS TO NEAREST PHASE OR NEUTRAL BUS. AS PER THE NEC. 5. THE SHORT CIRCUIT WITHSTAND CAPABILITY OF THE CABINET ASSEMBLY SHALL BE RATED AT 50,000 RMS SYMMETRICAL AMPERES. 6. CABINET DESIGN SHALL HAVE PROVISIONS FOR A SOLID DOOR TO ALLOW FOR THE METER ENCLOSURE TO BE MOUNTED REMOTELY FROM THE CABINET. 7. METERING COMPARTMENT TO BE TOTALLY ISOLATED FROM CT COMPARTMENT FOR REMOTE USE. USE CAT. NO. RTS800-208 WITH MS10P-208 OR RTS800-480 WITH MS10P-480. ALL TO CONFORM TO MES # 195. 8. MANUFACTURER SHALL FURNISH AND INSTALL 1/2-13 STUDS WITH SPLIT LOCK WASHERS AND HEX NUTS FOR CT MOUNTING. 9. USE ONLY MANUFACTURER S APPROVED LUG PROVIDED. (2) LUGS PER TERMINAL, EACH RATED FOR (1) 600 MCM-#4 OR (2) 250 MCM -#4 CABLES. 10. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL BE USED 11. PROVIDE PREWIRED TRANS "S" UNIT WITH #12 AWG STRANDED (19/25) THHN COPPER COLOR CODED WIRE FROM THE TEST SWITCH TO THE SOCKET ASSEMBLY AND FROM THE TEST SWITCH METERING COMPARTMENT INTO THE CT COMPARTMENT. LEAVE 7 FT. OF WIRE FOR FUTURE CONNECTION TO THE CURRENT TRANSFORMERS. USE EITHER HOOK OR RING TYPE TINNED COPPER LUGS FOR TERMINATIONS. ALL WIRING IN ACCORDANCE WITH CON EDISON MES #195, EXCEPT AS NOTED IN MES #751 FOR FORM 9S METER SOCKET. 12. SECURITY HARDWARE TO BE PROVIDED FOR CT CABINET DOOR AND METER ENCLOSURE COVER (TO BE INSTALLED BY CONTRACTOR). 13. 265/460 VOLT SERVICE REQUIRES A DISCONNECT SWITCH BEFORE THE CT CABINET. 4

CON EDISON S PLUG-IN METER SOCKET AND TEST SWITCH 30 AMP. CONT., 240V & 480V AC RATED (NEMA 3R) CATALOG NUMBERS MS10P-208 MS10P-480 CODE GAUGE GALVANIZED OR GALVANNEALED STEEL. 2. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL BE USED. 3. PROVIDED PREWIRED FROM TEST SWITCH TO METER BASE IN ACCORD WITH MES #195, EXCEPT AS NOTED IN MES #751, FOR FORM 9S METER SOCKET. 4. WIRE PROVIDED AND INSTALLED BY CONTRACTOR. 5

CON EDISON TRANS - A ENCLOSURES Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 745 TA-400-240 41x20x10 600 200-400 $1,710.00 745 TA-400-480 41x20x10 600 200-400 1,740.00 750 TA-800-240 48x24x10 600 400-800 2,110.00 750 TA-800-480 48x24x10 600 400-800 2,200.00 RT10P-240 21x14x5 240 295.00 RT10PA-480 21x14x5 480 310.00 3 HUB 3 HUB 24.00 3 1/2 HUB 3 1/2 HUB 28.00 4 HUB 4 HUB 30.00 TS-TCP TOP 16.00 CLOSING PLATE *Three Phase Units shall be modified in the field to Single Phase as per Con Edison s Inspectors specifications. 6

CON EDISON 400 AMPERE TRANS A CURRENT TRANSFORMER CABINET (NEMA 3R) 200 AMP. & 400 AMP., 240 V & 480V AC RATED CATALOG NUMBER TA-400-240 TA-400-480 CON EDISON SPEC. #MES 745 CATALOG NUMBERS CODE GAUGE GALVANIZED OR GALVANNEALED STEEL. 2. BUS BAR SHALL BE SILVER OR TIN PLATED AND SHALL BE SIZED PER THE NEC. 3. BUS BAR SHALL BE MOUNTED IN THE CABINET BY MEANS OF STANDOFF INSULATORS OR INSULATED MOUNTING BRACKETS. INSULATING MATERIAL SHALL CONFORM TO THE APPLICABLE SECTIONS OF UL 746 AND UL 94. CABINET SHALL BE UL APPROVED. 4. THE RIGHT HAND SIDE OF THE CABINET SHALL ALLOW FOR LINE AND LOAD CABLES TO ENTER AND EXIT THROUGH THE TOP OR THE BOTTOM OF THE CABINET. THIS SPACE SHALL ALLOW FOR THE CABLES TO MEET THE MINIMUM BENDING RADIUS TO NEAREST PHASE OR NEUTRAL BUS AS PER THE NEC. 5. THE SHORT CIRCUIT WITHSTAND CAPABILITY OF THE CABINET ASSEMBLY SHALL BE A MAXIMUM OF 50,000 RMS SYMMETRICAL AMPERES. 6. CABINET DESIGN SHALL HAVE PROVISIONS FOR A SOLID DOOR TO ALLOW FOR THE METER ENCLOSURE TO BE MOUNTED REMOTELY FROM THE CABINET. 7. HEX HEAD OR THUMB SCREWS MAY BE FURNISHED INSTEAD OF A THREE POINT LATCH. 8. MANUFACTURER SHALL FURNISH AND INSTALL _-13 STUDS WITH SPLIT LOCK WASHERS AND HEX NUTS FOR CT MOUNTING. 9. USE ONLY MANUFACTURER S APPROVED LUG PROVIDED. EACH LUG IS RATED FOR (1) 600 MCM-#4 OR (2) 250MCM-#4 CABLES. 10. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL BE USED. 11. PROVIDE #12 AWG SOLID WHITE INSULATED COPPER WIRE, 12" LONG LEFT ABOVE THE METERING TEST SWITCH, WIRE TO BE FORMED AND MOUNTED ON TEST SWITCH. 12. PROVIDE #12 AWG STRANDED (19/25) THHN COPPER COLOR CODED WIRE FROM TEST SWITCH METERING COMPARTMENT INTO CT COMPARTMENT. LEAVE 5 FT. OF WIRE FOR FUTURE CONNECTION TO CURRENT TRANSFORMERS. ALL WIRING IN ACCORDANCE WITH CON EDISON MES #195. 13. SECURITY HARDWARE TO BE PROVIDED FOR CT CABINET DOOR AND METER ENCLOSURE COVER (TO BE INSTALLED BY CONTRACTOR). 14. 265/460 VOLT SERVICE REQUIRES A DISCONNECT SWITCH BEFORE THE CT CABINET. 7

CON EDISON 800 AMPERE TRANS A CURRENT TRANSFORMER CABINET (NEMA 3R) 600 400 AMP. 600 & 800 AMP. AMP., & 800 AMP., 240V 240 AC V && 480V AC RATED CATALOG NUMBER TA-800-240 TA-800-480 CON EDISON SPEC. #MES 750 CATALOG NUMBERS CATALOG TA-800-240 NUMBERS RT10P-A CODE GAUGE GALVANIZED OR GALVANNEALED STEEL. 2. BUS BAR SHALL BE SILVER OR TIN PLATED AND SHALL BE SIZED PER THE NEC. 3. BUS BAR SHALL BE MOUNTED IN THE CABINET BY MEANS OF STANDOFF INSULATORS OR INSULATED MOUNTING BRACKETS. INSULATING MATERIAL SHALL CONFORM TO THE APPLICABLE SECTIONS OF UL 746 AND UL 94. CABINET SHALL BE UL APPROVED. 4. THE RIGHT HAND SIDE OF THE CABINET SHALL ALLOW FOR LINE AND LOAD CABLES TO ENTER AND EXIT THROUGH THE TOP OR THE BOTTOM OF THE CABINET. THIS SPACE SHALL ALLOW FOR THE CABLES TO MEET THE MINIMUM BENDING RADIUS TO NEAREST PHASE OR NEUTRAL BUS AS PER THE NEC. 5. THE SHORT CIRCUIT WITHSTAND CAPABILITY OF THE CABINET ASSEMBLY SHALL BE A MAXIMUM OF 50,000 RMS SYMMETRICAL AMPERES. 6. CABINET DESIGN SHALL HAVE PROVISIONS FOR A SOLID DOOR TO ALLOW FOR THE METER ENCLOSURE TO BE MOUNTED REMOTELY FROM THE CABINET. 7. HEX HEAD OR THUMB SCREWS MAY BE FURNISHED INSTEAD OF A THREE POINT LATCH. 8. MANUFACTURER SHALL FURNISH AND INSTALL _-13 STUDS WITH SPLIT LOCK WASHERS AND HEX NUTS FOR CT MOUNTING. 9. USE ONLY MANUFACTURER S APPROVED LUG PROVIDED. EACH LUG IS RATED FOR (1) 600 MCM-#4 OR (2) 250MCM-#4 CABLES. 10. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL BE USED. 11. PROVIDE #12 AWG SOLID WHITE INSULATED COPPER WIRE, 12" LONG LEFT ABOVE THE METERING TEST SWITCH, WIRE TO BE FORMED AND MOUNTED ON TEST SWITCH. 12. PROVIDE #12 AWG STRANDED (19/25) THHN COPPER COLOR CODED WIRE FROM TEST SWITCH METERING COMPARTMENT INTO CT COMPARTMENT. LEAVE 5 FT. OF WIRE FOR FUTURE CONNECTION TO CURRENT TRANSFORMERS. ALL WIRING IN ACCORDANCE WITH CON EDISON MES #195. 13. SECURITY HARDWARE TO BE PROVIDED FOR CT CABINET DOOR AND METER ENCLOSURE COVER (TO BE INSTALLED BY CONTRACTOR). 14. 265/460 VOLT SERVICE REQUIRES A DISCONNECT SWITCH BEFORE THE CT CABINET. 8

CON EDISON A BASE METER SOCKET AND TEST SWITCH 30 AMP. CONT., 240V & 480V AC RATED (NEMA 3R) CATALOG NUMBERS RT10PA-240 RT10PA-480 CODE GAUGE GALVANIZED OR GALVANNEALED STEEL. 2. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL BE USED. 3. PROVIDED WITH #12 AWG SOLID WHITE INSULATED COPPER WIRE, 12" LONG ABOVE THE METERING TEST SWITCH. WIRE TO BE FORMED AND MOUNTED ON "A" BASE METER AT TIME OF INSTALLATION. 4. WIRE PROVIDED AND INSTALLED BY CONTRACTOR. 9

CON EDISON COPPER DETAIL BOXES/ CURRENT TRANSFORMER CABINETS Con Ed Navtech AMPS Size List Spec Cat# Price EO-9525-B 9525 400 48x24x18 $2400.00 EO-9525-B 9525 400 54x24x18 2400.00 EO-9072-B 9072 800 68x26x18 2720.00 EO-9072-B 9072 1200 68x26x18 3170.00 EO-9073-B 9073 2000 78x34x18 3170.00 142 CT-36 400 27x36x10 790.00 142 CT-44 400 27x44x10 980.00 298 298CT 800 72x32x12 2970.00 298 298CT 1200 72x32x12 3530.00 377 377CT As Required As Required CALL 9073-B 9073 84" 9073-B 9073 92" 10

CON EDISON TRANS-S/SWITCH COMBINATION UNITS Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 745 TS/SW 70x20x11 240 200-400 $4,640.00 400-240-B 745 TS/SW 65x20x11 240 200-400 4,410.00 400-240-T 745 TS/SW 70x21x11 480 200-400 4,980.00 400-480-B 745 TS/SW 76x20x12 480 200-400 4,760.00 400-480-T 750 TS/SW 82x24x12 240 400-800 7,000.00 800-240-B 750 TS/SW 76x20x12 240 400-800 6,650.00 800-240-T 750 TS/SW 82x24x12 480 400-800 7,430.00 800-480-B 750 TS/SW 76x20x12 480 400-800 7,090.00 800-480-T 11