NEW. Large range of models, customizable performance output Flexible equipment options Easy and clear operation. LAUDA Variocool. Circulation chillers

Similar documents
LAUDA Variocool. Numerous options, compact design, easy operation

LAUDA Variocool. Numerous options, compact design, easy operation

The right temperature worldwide. Chapter Variocool. LAUDA the big one. Thermostats, Circulation chillers, Water baths

The right temperature worldwide. Chapter Variocool. LAUDA the big one. Thermostats, Circulation chillers, Water baths. Overall Brochure 2016/2017 1

LAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C

The right temperature worldwide. Chapter Integral. LAUDA the big one. Thermostats, Circulation chillers, Water baths

The right temperature worldwide. Chapter Integral. LAUDA the big one. Thermostats, Circulation chillers, Water baths. Overall Brochure 2016/2017 1

Circulating Chillers / Immersion Coolers

Providing a constant temperature control and high cooling efficiency.

LAUDA the big one NEW. LAUDA Microcool LAUDA Variocool LAUDA Viscothermostats LAUDA Integral XT 4 H (W) and XT 8 H (W)

Recirculating Coolers

Climate chambers with illumination

Operating Instructions

Operating Instructions

Climate chamber with illumination

C 200 Modern Construction. Flexible Modular Design. Highest Safety.

Safety drying ovens. Advantages: Areas of application: FDL series 115

Product Overview & What s New for high precision thermoregulation

Refrigerated incubator with Peltier technology

Heating oven with mechanical convection

Rotary Vane Compressors DRT4.04 DRT4.08

Highly Dynamic Temperature Control Systems & FORTE HT ENGLISH

Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced

Nexa 1200 Fuel Cell System

geass.com Environmental simulation chambers for cyclic temperature testing MK MKT series Alternating temperature and climate testing

VTZ variable speed Reciprocating compressors

Safety drying oven with expended temperature range

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

BASIC LINE. LAB Freezers & Refrigerators

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

VAPORIX The Automatic Monitoring System for Active Vapour Recovery

CWP-CO / CWP-RC / CWP-HP 02 to 35

mass flowmeter for compressed air

MVP DC SERIES. Diaphragm pumps as backing pumps for HiPace turbopumps

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

MVP 015 DC SERIES. Diaphragm pumps as backing pumps for HiPace turbopumps

Heating oven with natural convection

Load Banks. Load Banks Test Benches Battery Discharge Testers. Hardware Reference

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

Ucontrol. 1 Data sheet. Multipurpose controllers for variable voltage 3 ~ fans PXDM Examples of application. 1.2 Equipment / Function

Blue e+ chillers with the principle

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

Heating chamber with mechanical convection

Safety drying ovens with expanded temperature range

Application. Battery. Public Grid GS HYBRID INVERTER

HEATING & COOLING COIL PRODUCTS AIR COOLED CONDENSERS

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

technical catalogue tetris KW Chiller and heat pumps air/water

Heating oven with mechanical control

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

Heating chamber with mechanical convection

Interface I-300 / I-300 Pro Technical data sheet

Variable speed drives

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

EAS822 (Contrac) Power Electronic Unit

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Flash Point Process Analyzer

±0.18 F (±0.1 C) 88 lb (40 kg) 104 lb (47 kg) 152 lb (69 kg) 161 lb (73 kg) With heating function. Convenient functions

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Field IT Actuators & Positioners. Intelligent Electric Modulating Actuator. Contrac RHD Intelligent Electric Modulating Actuator

Technical specification

LED CONVERTERS FOR LED MODULES 24 V

HDE 4000-DM. Electrohydraulic high-pressure unit without pressure intensifier in modular design

Foaming of Lubricating Oils (manual)

MDL series Safety drying ovens with first class safety features and an expanded temperature range

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Electrical Linear Actuator RSD10 / RSD20 (Contrac)

J TS 7090 Thyristor power switch

Model ED 400 Drying and heating chambers Classic.Line with natural convection

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

Circulation pumps BFP-ATEX-T3/T4

RSD100 (Contrac) Electrical Linear Actuator

HDE 4000-D. Electrohydraulic high-pressure unit without pressure intensifier in mobile design. HDE 4000-D /DM 4000 bar direct power in smallest space.

Heating chamber with mechanical convection

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

LCU DX Efficient cooling with no loss of space

Centrifugal fan with highly efficient EC drive motor

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

Heating chamber with mechanical convection

Mini Vehicle Controller (MVC)

dynamic, reliable and efficient

Immersion chillers E 01

TopTech HighTech Circulators

Integrated temperature test and calibration bench Model CBS-SC4000

Compact I/O modules (IP20)

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Feed Pumps VP / VPB / VPBM

Water-Cooled DEUTZ BF6M101. Standby: 200KW/250KVA. Prime: 180KW/225KVA

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Accessories guide DHP-R

SUCO Product Overview

Power distribution components

control systems Made in Italy Integrated systems for the web tension regulation

Transcription:

Large range of models, customizable performance output Flexible equipment options Easy and clear operation NEW LAUDA Variocool Circulation chillers

LAUDA Variocool Circulation chillers for variable use in laboratory, mini-plant and production for temperatures from -20 up to 40 C Numerous options, compact design, easy operation Application examples Central cooling water supply in laboratories Cooling of analytical devices Temperature control of bioreactors Supply to cooling traps The LAUDA Variocool circulation chillers offer a broad performance spectrum for demanding temperature control tasks. The color TFT screen makes operation easy. A USB interface and an alarm contact are integrated as standard features. Additional interfaces are available as accessories. They are located in the front of the device, which means they are easy to access. The circulation chillers with their multitude of options are very well suited to a number of different areas of application. Optional pumps, for example, enable higher supply pressure. Optional heating units, which are adapted to the cooling capacity, enable the quick heating of the connected application when needed. 2

Do you have questions about this product? E-mail: variocool@lauda.de Your advantages at a glance The Variocool advantages All models with electronic expansion valve to regulate refrigeration and use only the minimum amount of energy required. These units are marked with the Energy Saving Star label. 13 models in air or water-cooled design with cooling capacities from 600 W up to 10 kw Due to their compact design, units up to 2 kw of cooling capacity can be placed under the laboratory table Display and operation via color TFT screen and membrane keyboard Electronic fill gauge on the display and low level alarm when fluid level too low Your benefits Very energy efficient models with good temperature control and cost savings thanks to reduced energy consumption The appropriate solution to every requirement Saves valuable lab space Easy and clear setup options Early detection of insufficient fluid Options: High power pumps Heaters Fow control Outdoor installation Use with DI water Noice reduction Deionized water (DI water) USB interface and alarm contact standard features in the front of the device Retrofittable interfaces as accessory: analog module RS-232/485 interface contact modules profibus module Pt100/LiBus module Flexible customization to applications Easy accessibility Flexible control options Front grill can be easily removed without tool Tower design for larger models (from VC 7000) Microchannel condensers in all air-cooled models All models (except VC 600) with adjustable bypass and pressure gauge Easy to clean condenser Space-saving setup Reduced footprint and lower refrigerant quantity Connection of pressure sensitive applications 3

LAUDA Variocool Variocool Circulation chillers with cooling capacities up to 2 kw Variocool circulation chillers function in an operating temperature range of -20 to 40 C. Optional heaters can be added to increase the maximum temperature to 80 C. For greater pressure requirements, optional pumps are available with the VC 1200 version or higher. With the exception of the VC 600, all models are also available as water-cooled versions. All devices are equipped with lockable casters. The compact dimensions of the models from VC 600 to VC 2000 (W) allows to place them under the laboratory table. Pump characteristic Heat transfer liquid: Water Pressure bar 1.0 0.8 0.6 0.4 0.2 0 0 5 10 15 20 25 30 L/min Flow Temperature range -20...40 C (-20...80 C with optional heater) Included as standard USB interface alarm contact Included accessories nipples screw caps Options High-power pumps* heater flow control outdoor installation DI water compatibility Circulation chiller VC 600 All technical data on page 9 595 mm 650 mm 650 mm 650 mm 650 mm Technical features VC 600 VC 1200 VC 1200 W VC 2000 VC 2000 W Working temperature range C -20 40-20 40-20 40-20 40-20 40 Working temperature range with optional heater C -20 80-20 80-20 80-20 80-20 80 Temperature stability ±K 0.2 0.2 0.2 0.2 0.2 Cooling output at 20 C kw 0.6 1.2 1.2 2.0 2.0 Pump pressure max. bar 0.9 0.9 0.9 0.9 0.9 Pump flow L/min 28 28 28 28 28 230 V; 50 Hz LWG 175 LWG 176 LWG 182 LWG 177 LWG 183 220 V; 50/60 Hz LWG 675** LWG 576 LWG 582 LWG 577 LWG 583 208-220 V; 60 Hz LWG 275*** LWG 876 LWG 882 LWG 877 LWG 883 115 V; 60 Hz LWG 475 4 * Using such a pump can change the available cooling capacity, and causes a change of the height of the housing from 650 mm to 790 mm for VC 1200 (W) and VC 2000 (W) ** 100 V; 50/60 Hz *** 220 V; 60 Hz

Do you have questions about this product? E-mail: variocool@lauda.de Variocool Circulation chillers with cooling capacities up to 5 kw The models VC 3000 and VC 5000 offer cooling capacities of 3 and 5 kw. They are also available in water-cooled design (W). For flexible adaption to different applications the chillers can also be delivered with optional high-power pumps or heaters. Further options are a flow control, outdoorinstallation or a noise reduction for the types VC 5000 and VC 5000 W. Pump characteristic Heat transfer liquid: Water Pressure bar 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 0 5 10 15 20 25 30 35 L/min Flow Temperature range -20...40 C (-20...80 C with optional heater) Included as standard USB interface alarm contact Included accessories nipples screw caps Options High-power pumps* heater flow control outdoor installation noice reduction (VC 5000, VC 5000 W) Circulation chiller VC 3000 W All technical data on page 9 970 mm 970 mm 970 mm 970 mm Technical features VC 3000 VC 3000 W VC 5000 VC 5000 W Working temperature range C -20 40-20 40-20 40-20 40 Working temperature range with optional heater C -20 80-20 80-20 80-20 80 Temperature stability ±K 0.2 0.2 0.2 0.2 Cooling output at 20 C kw 3.0 3.0 5.0 5.0 Pump pressure max. bar 3.2 3.2 3.2 3.2 Pump flow L/min 37 37 37 37 230 V; 50 Hz LWG 178 LWG 184 LWG 279** LWG 285** 220 V; 50/60 Hz LWG 578 LWG 584 LWG 379*** LWG 385*** 208-220 V; 60 Hz LWG 878 LWG 884 LWG 479**** LWG 485**** * Using such a pump can change the available cooling capacity ** 400 V; 3/N/PE; 50 Hz *** 208-220 V; 3/PE; 60 Hz **** 200 V; 3/PE; 50/60 Hz 5

LAUDA Variocool Variocool Circulation chillers with cooling capacities up to 10 kw The highly efficient tower design circulation chillers provide cooling capacities between 7 and 10 kw. Options like heating or high-power pumps add to the devices areas of application. The models are available in air or water-cooled design. All models are equipped with casters which can be controlled and locked. Pump characteristic Heat transfer liquid: Water Pressure bar 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 0 5 10 15 20 25 30 35 L/min Flow Temperature range -20...40 C (-20...80 C with optional heater) Included as standard USB interface alarm contact Included accessories nipples screw caps Options High-power pumps* heater flow control outdoor installation noice reduction Circulation chiller VC 7000 All technical data on page 9 1250 mm 1250 mm 1250 mm 1250 mm Technical features VC 7000 VC 7000 W VC 10000 VC 10000 W Working temperature range C -20 40-20 40-20 40-20 40 Working temperature range with optional heater C -20 80-20 80-20 80-20 80 Temperature stability ±K 0.5 0.5 0.5 0.5 Cooling output at 20 C kw 7.0 7.0 10.0 10.0 Pump pressure max. bar 3.2 3.2 3.2 3.2 Pump flow L/min 37 37 37 37 400 V; 3/N/PE; 50 Hz LWG 280 LWG 286 LWG 281 LWG 287 208-220 V; 3/PE; 60 Hz LWG 380 LWG 386 LWG 381 LWG 387 200 V; 3/PE; 50/60 Hz LWG 480 LWG 486 LWG 481 LWG 487 6 * Using such a pump can change the available cooling capacity

Do you have questions about this product? E-mail: variocool@lauda.de Options Variocool For all Variocool models, different options can be ordered. The options can only be affixed at point of production. Please check the table below for compatibility of options with the corresponding circulation chiller type. Pump characteristics optional pumps Heat transfer liquid: water Pressure bar 5.0 4.0 3.0 2.0 1.0 0 1 2 3 0 10 20 30 40 50 60 L/min Flow 1 3.2 bar, 37 L/min 2 4.8 bar, 37 L/min 3 5.0 bar, 60 L/min Options Heaters For all types. Extension of the temperature up to 80 C. High-power pumps For all types, except VC 600. Flow control For all types. Outdoor installation For all types. An additional protection with a roof is necessary. DI water For VC 600 to VC 2000 W. Corrosion resistant construction for use with deionized water. Noise reduction For models VC 5000 up to 10000 W. Options not power supply dependent Option VC 600 VC 1200 VC 1200 W Flow control 1/2 LWZ 118 Flow control 3/4 LWZ 119 Outdoor installation LWZ 120 Outdoor installation LWZ 121 Outdoor installation LWZ 122 Outdoor installation LWZ 123 DI water LWZ 124 DI water LWZ 125 Noise reduction LWZ 126 Noise reduction LWZ 127 Noise reduction LWZ 128 VC 2000 VC 2000 W VC 3000 VC 3000 W VC 5000 VC 5000 W VC 7000 VC 7000 W VC 10000 VC 10000 W 7

LAUDA Variocool Options power supply dependent Option Heater 1.5 kw LWZ 1095 Heater 4.5 kw LWZ 2096 Heater 9.0 kw LWZ 2097 Pump, 3.2 bar 37 L/min** LWZ 1100 Pump, 3.2 bar 37 L/min** LWZ 1101 Pump, 4.8 bar 37 L/min** LWZ 1103 Pump, 4.8 bar 37 L/min** LWZ 1104 Pump, 4.8 bar 37 L/min** LWZ 1102 Pump, 4.8 bar 37 L/min** LWZ 2105 Pump, 5.0 bar 60 L/min** LWZ 2106 208-220 V; 60 Hz 208-220 V; 3/PE; 60 Hz Option VC 600 VC 600 115 V; 60 Hz 220 V; 60 Hz VC 600 VC 1200* VC 1200* 230 V; 50 Hz 400 V; 3/N/PE; 50 Hz VC 1200 W* VC 1200 W* VC 2000* VC 2000 W* Heater 1.15 kw LWZ 4095 Heater 1.35 kw LWZ 2095 Heater 1.20-1.35 kw LWZ 8095 Heater 3.65-4.1 kw LWZ 3096 Heater 7.35-8.2 kw LWZ 3097 Pump, 3.2 bar 37 L/min** LWZ 8100 Pump, 3.2 bar 37 L/min** LWZ 8101 Pump, 4.8 bar 37 L/min** LWZ 2103 Pump, 4.8 bar 37 L/min** LWZ 2104 Pump, 4.8 bar 37 L/min** LWZ 2102 Pump, 4.8 bar 37 L/min** LWZ 3105 Pump, 5.0 bar 60 L/min** LWZ 3106 VC 2000* VC 2000 W* VC 3000 VC 3000 VC 3000 W VC 3000 W VC 5000 VC 5000 VC 5000 W VC 5000 W VC 7000 VC 7000 VC 7000 W VC 7000 W VC 10000 VC 10000 VC 10000 W VC 10000 W 100 V; 50/60 Hz 200 V; 50/60 Hz 200 V; 3/PE; 50/60 Hz 8 Option VC 600 VC 1200* VC 1200 W* VC 2000 W* Heater 1.0 kw LWZ 6095 Heater 1.1 kw LWZ 5095 Heater 3.4 kw LWZ 4096 Heater 6.8 kw LWZ 4097 Pump, 3.2 bar 37 L/min** LWZ 5100 Pump, 3.2 bar 37 L/min** LWZ 5101 Pump, 4.8 bar 37 L/min** LWZ 5103 Pump, 4.8 bar 37 L/min** LWZ 5104 Pump, 4.8 bar 37 L/min** LWZ 5102 Pump, 4.8 bar 37 L/min** LWZ 4105 Pump, 5.0 bar 60 L/min** LWZ 4106 * Use with high-power pumps causes a change of the height of the housing from 650 mm to 790 mm. ** Using such a pump can change the available cooling capacity VC 2000* VC 3000 VC 3000 W VC 5000 VC 5000 W VC 7000 VC 7000 W VC 10000 VC 10000 W

Do you have questions about this product? E-mail: variocool@lauda.de Type LAUDA Variocool Temperature stability Working temperature range (with optional heater) Cooling output (measured with ethanol and with standard pump, 20 C ambient temperature) -10 C Ambient temperature range 20 C 10 C 0 C -20 C Heater power optional heater Pump pressure max. Pump flow max. (pressure) Pump connection thread (inner diameter in mm) For tubings Filling volume Dimensions (WxDxH) C ±K C kw kw kw kw kw kw bar L/min L mm db(a) kg V;Hz VC 600-20 40 (80) 0.2 5...40 0.60 0.50 0.36 0.21 0.08 1.5 0.9 28 M16 x 1 (10) 1 /2 8 350x480x595 47 39 230; 50 LWG 175 VC 1200-20 40 (80) 0.2 5...40 1.20 1.00 0.70 0.40 0.18 1.5 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 51 54 230; 50 LWG 176 VC 1200 W -20 40 (80) 0.2 5...40 1.20 1.00 0.70 0.40 0.18 1.5 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 49 51 230; 50 LWG 182 VC 2000-20 40 (80) 0.2 5...40 2.00 1.50 1.06 0.68 0.38 1.5 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 52 57 230; 50 LWG 177 VC 2000 W -20 40 (80) 0.2 5...40 2.00 1.50 1.06 0.68 0.38 1.5 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 50 54 230; 50 LWG 183 VC 3000-20 40 (80) 0.2 5...40 3.00 2.40 1.68 1.03 0.60 1.5 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 57 93 230; 50 LWG 178 VC 3000 W -20 40 (80) 0.2 5...40 3.00 2.40 1.68 1.03 0.60 1.5 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 55 89 230; 50 LWG 184 VC 5000-20 40 (80) 0.2 5...40 5.00 3.90 2.75 1.70 1.00 4.5 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 59 98 400; 3/N/PE; 50 LWG 279 VC 5000 W -20 40 (80) 0.2 5...40 5.00 3.90 2.75 1.70 1.00 4.5 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 57 94 400; 3/N/PE; 50 LWG 285 VC 7000-20 40 (80) 0.5 5...40 7.00 5.30 3.70 2.40 1.30 4.5 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 60 138 400; 3/N/PE; 50 LWG 280 VC 7000 W -20 40 (80) 0.5 5...40 7.00 5.30 3.70 2.40 1.30 4.5 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 58 131 400; 3/N/PE; 50 LWG 286 VC 10000-20 40 (80) 0.5 5...40 10.00 7.60 5.30 3.50 2.00 9.0 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 67 147 400; 3/N/PE; 50 LWG 281 VC 10000 W -20 40 (80) 0.5 5...40 10.00 7.60 5.30 3.50 2.00 9.0 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 65 140 400; 3/N/PE; 50 LWG 287 Noise level Weight Power supply Technical data LAUDA Variocool VC 600-20 40 (80) 0.2 5...40 0.60 0.50 0.36 0.21 0.08 1.15 0.9 28 M16 x 1 (10) 1 /2 8 350x480x595 47 39 115; 60 LWG 475 VC 600-20 40 (80) 0.2 5...40 0.60 0.50 0.36 0.21 0.08 1.35 0.9 28 M16 x 1 (10) 3 /4 8 350x480x595 47 39 208-220; 60 LWG 275 VC 1200-20 40 (80) 0.2 5...40 1.20 1.00 0.70 0.40 0.18 1.35 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 51 54 208-220; 60 LWG 876 VC 1200 W -20 40 (80) 0.2 5...40 1.20 1.00 0.70 0.40 0.18 1.35 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 49 51 208-220; 60 LWG 882 VC 2000-20 40 (80) 0.2 5...40 2.00 1.50 1.06 0.68 0.38 1.35 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 52 57 208-220; 60 LWG 877 VC 2000 W -20 40 (80) 0.2 5...40 2.00 1.50 1.06 0.68 0.38 1.35 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 50 54 208-220; 60 LWG 883 VC 3000-20 40 (80) 0.2 5...40 3.00 2.40 1.68 1.03 0.60 1.35 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 57 93 208-220; 60 LWG 878 VC 3000 W -20 40 (80) 0.2 5...40 3.00 2.40 1.68 1.03 0.60 1.35 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 55 89 208-220; 60 LWG 884 VC 5000-20 40 (80) 0.2 5...40 5.00 3.90 2.75 1.70 1.00 4.1 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 59 98 208-220; 3/PE; 60 LWG 379 VC 5000 W -20 40 (80) 0.2 5...40 5.00 3.90 2.75 1.70 1.00 4.1 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 57 94 208-220; 3/PE; 60 LWG 385 VC 7000-20 40 (80) 0.5 5...40 7.00 5.30 3.70 2.40 1.30 4.1 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 60 138 208-220; 3/PE; 60 LWG 380 VC 7000 W -20 40 (80) 0.5 5...40 7.00 5.30 3.70 2.40 1.30 4.1 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 58 131 208-220; 3/PE; 60 LWG 386 VC 10000-20 40 (80) 0.5 5...40 10.00 7.60 5.30 3.50 2.00 8.2 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 67 147 208-220; 3/PE; 60 LWG 381 VC 10000 W -20 40 (80) 0.5 5...40 10.00 7.60 5.30 3.50 2.00 8.2 3.0 37 G 1 1 /4 (20) 1 64 650x670x1250 65 140 208-220; 3/PE; 60 LWG 387 LAUDA Variocool VC 600-20 40 (80) 0.2 5...40 0.60 0.50 0.36 0.21 0.08 1.0 0.9 28 M16 x 1 (10) 1 /2 8 350x480x595 47 39 100; 50/60 LWG 675 VC 1200-20 40 (80) 0.2 5...40 1.20 1.00 0.70 0.40 0.18 1.1 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 51 54 200; 50/60 LWG 576 VC 1200 W -20 40 (80) 0.2 5...40 1.20 1.00 0.70 0.40 0.18 1.1 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 49 51 200; 50/60 LWG 582 VC 2000-20 40 (80) 0.2 5...40 2.00 1.50 1.06 0.68 0.38 1.1 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 52 57 200; 50/60 LWG 577 VC 2000 W -20 40 (80) 0.2 5...40 2.00 1.50 1.06 0.68 0.38 1.1 0.9 28 G 3 /4 (15) 3 /4 15 450x550x650 50 54 200; 50/60 LWG 583 VC 3000-20 40 (80) 0.2 5...40 3.00 2.40 1.68 1.03 0.60 1.1 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 57 93 200; 50/60 LWG 578 VC 3000 W -20 40 (80) 0.2 5...40 3.00 2.40 1.68 1.03 0.60 1.1 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 55 89 200; 50/60 LWG 584 VC 5000-20 40 (80) 0.2 5...40 5.00 3.90 2.75 1.70 1.00 3.4 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 59 98 200; 3/PE; 50/60 LWG 479 VC 5000 W -20 40 (80) 0.2 5...40 5.00 3.90 2.75 1.70 1.00 3.4 3.2 37 G 3 /4 (15) 3 /4 33 550x650x970 57 94 200; 3/PE; 50/60 LWG 485 VC 7000-20 40 (80) 0.5 5...40 7.00 5.30 3.70 2.40 1.30 3.4 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 60 138 200; 3/PE; 50/60 LWG 480 VC 7000 W -20 40 (80) 0.5 5...40 7.00 5.30 3.70 2.40 1.30 3.4 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 58 131 200; 3/PE; 50/60 LWG 486 VC 10000-20 40 (80) 0.5 5...40 10.00 7.60 5.30 3.50 2.00 6.8 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 67 147 200; 3/PE; 50/60 LWG 481 VC 10000 W -20 40 (80) 0.5 5...40 10.00 7.60 5.30 3.50 2.00 6.8 3.2 37 G 1 1 /4 (20) 1 64 650x670x1250 65 140 200; 3/PE; 50/60 LWG 487 All units are carried out in protection class IP 32 9

LAUDA Variocool Variocool accessories (excerpt) Tubings EPDM (also to use for cooling water) di (mm) de (mm) Temp. range C RKJ 031 13 ( 1 /2 ) 19-40...100 20 RKJ 032 19 ( 3 /4 ) 27-40...100 20 RKJ 033 25 (1 ) 34-40...100 20 RKJ 111 9 11 10...120 1 RKJ 112 12 14 10...120 1 di = internal diameter ; de = external diameter Tube clips, stainless steel To secure tubings EZS 032 Description Tube clip 16-27 mm,1/2 external Ø EZS 015 Tube clip 20-32 mm, 3/4 EZS 016 Tube clip 25-40 mm, 1 Pressure max. bar RKJ 031 EZS 032 Heat transfer liquids Designation Temperature range 5 L 10 L 20 L Aqua 90 5 90 C LZB 120 LZB 220 LZB 320 Kryo 30-30 90 C LZB 109 LZB 209 LZB 309 Interface modules LRZ 912 LRZ 913 LRZ 914 LRZ 915 LRZ 917 LRZ 918 Description Analog module, 2 x In, 2 x Out, 0(4) 20 ma or 0 10 V RS 232/485 interface, electrically isolated, 9-pin SUB-D Contact module NAMUR, 1 x In, 1 x Out, NE 28, 2 DIN sockets Contact module SUB-D, 3 x In, 3 x Out, 15-pin SUB-D Profibus interface, electrically isolated, 9-pin SUB-D Pt100/LiBus module LRZ 912 LRZ 913 LRZ 914 LRZ 915 LRZ 917 LRZ 918 10 Thermostats Circulation chillers Water baths Process cooling systems Heat transfer systems Secondary circuit systems Viscometers Tensiometers LAUDA DR. R. WOBSER GMBH & CO. KG P.O. Box 12 51 97912 Lauda-Königshofen Germany Phone: +49 (0)9343 503-0 Fax: +49 (0)9343 503-222 E-mail: info@lauda.de Internet: www.lauda.de 3-346-e-1/1.13 Subject to technical changes.